Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Microstructure investigation of 13Cr-2Mo ODS steel components obtained by high voltage electric discharge compaction technique

Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10–15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining the initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. As a result, the choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.

36 MATERIALS SCIENCE↗

The Gas Exchange Experiment for life detection - The Viking Mars Lander.

The Gas Exchange Experiment of the Viking mission accepts a sample of Martian soil, incubates this soil with nutrient medium, and periodically samples the enclosed atmosphere over this soil for the gases H2, N2, O2, Kr, and CO2. These gases are analyzed by an automated gas chromatograph, and the data are transmitted to earth. The design of the experiment and the qualitative and quantitative changes, if any, of gas composition should allow conclusions to be made on the presence of life on Mars. Data and theory substantiating this approach are presented.

Oyama, V. I.↗

In Situ Strategy of the 2011 Mars Science Laboratory to Investigate the Habitability of Ancient Mars

The ten science investigations of the 2011 Mars Science Laboratory (MSL) Rover named "Curiosity" seek to provide a quantitative assessment of habitability through chemical and geological measurements from a highly capable robotic' platform. This mission seeks to understand if the conditions for life on ancient Mars are preserved in the near-surface geochemical record. These substantial payload resources enabled by MSL's new entry descent and landing (EDL) system have allowed the inclusion of instrument types nevv to the Mars surface including those that can accept delivered sample from rocks and soils and perform a wide range of chemical, isotopic, and mineralogical analyses. The Chemistry and Mineralogy (CheMin) experiment that is located in the interior of the rover is a powder x-ray Diffraction (XRD) and X-ray Fluorescence (XRF) instrument that provides elemental and mineralogical information. The Sample Analysis at Mars (SAM) suite of instruments complements this experiment by analyzing the volatile component of identically processed samples and by analyzing atmospheric composition. Other MSL payload tools such as the Mast Camera (Mastcam) and the Chemistry & Camera (ChemCam) instruments are utilized to identify targets for interrogation first by the arm tools and subsequent ingestion into SAM and CheMin using the Sample Acquisition, Processing, and Handling (SA/SPaH) subsystem. The arm tools include the Mars Hand Lens Imager (MAHLI) and the Chemistry and Alpha Particle X-ray Spectrometer (APXX). The Dynamic Albedo of Neutrons (DAN) instrument provides subsurface identification of hydrogen such as that contained in hydrated minerals

Mahaffy, Paul R.↗

Relative Detectability of Iron-Bearing Phases for the Mars 2020 Sherloc Deep UV Raman Instrument: 1. Focusing on Carbonates

A deep ultraviolet (DUV) Raman and fluorescence instrument is a surface standoff instrument mounted on the robotic arm of the Mars 2020 (M2020) rover Perseverance, and it is a key element of the Scanning Habitable Environments with Luminescence for Organics and Chemicals (SHERLOC) investigation [1]. Measurement and science objectives include mineralogical and organic images (~100 μm/pixel) that map sub-millimeter spatial distributions and characterization of primary and secondary minerals, potential organics, and their interaction/alteration products. The results of data analysis pertain to understanding igneous and alteration processes on Mars through time, assessing habitability, evidencing in situ biosignatures, and, along with results from other Perseverance instruments, selecting samples to cache for Mars sample return. Acceptance of the SHERLOC investigation for the NASA M2020 mission [2] created a need for Mars-relevant DUV Raman spectra, particularly for inorganic materials [e.g., 3, 4]. As reported previously [e.g., 4, 5], phases with Fe cations as essential elements (e.g., siderite (FeCO3) and ankerite (FeCa(CO3)2) for carbonates) significantly hinder detection by DUV Raman because of intense absorption of incident and scattered DUV laser radiation by Fe cations. We report here the relative detectability of carbonates (Mg,Ca,Fe,Mn)CO3 by DUV Raman using a SHERLOC analog laboratory instrument.

R V Morris↗

Status and Planned Experiments of the Hiradmat Pulsed Beam Material Test Facility at CERN SPS

HiRadMat (High Irradiation to Materials) is a facility at CERN designed to provide high-intensity pulsed beams to an irradiation area where material samples as well as accelerator component assemblies (e.g. vacuum windows, shock tests on high power targets, collimators) can be tested. The beam parameters (SPS 440 GeV protons with a pulse energy of up to 3.4 MJ, or alternatively lead/argon ions at the proton equivalent energy) can be tuned to match the needs of each experiment. It is a test area designed to perform single pulse experiments to evaluate the effect of high-intensity pulsed beams on materials in a dedicated environment, excluding long-time irradiation studies. The facility is designed for a maximum number of 1016 protons per year, in order to limit the activation of the irradiated samples to acceptable levels for human intervention. This paper will demonstrate the possibilities for research using this facility and go through examples of upcoming experiments scheduled in the beam period 2015/2016.

43 PARTICLE ACCELERATORS↗

Spectroscopic quantification of extremely rare molecular species in the presence of interfering optical absorption

Optical spectrometer apparatus, systems, and methods for analysis of carbon-14 including a resonant optical cavity configured to accept a sample gas including carbon-14, an optical source configured to deliver optical radiation to the resonant optical cavity, an optical detector configured to detect optical radiation emitted from the resonant cavity and to provide a detector signal; and a processor configured to compute a carbon-14 concentration from the detector signal, wherein computing the carbon-14 concentration from the detector signal includes fitting a spectroscopic model to a measured spectrogram, wherein the spectroscopic model accounts for contributions from one or more interfering species that spectroscopically interfere with carbon-14.

36 MATERIALS SCIENCE↗

Computing Risk of Pyrotechnic Devices Using Lot Acceptance Testing

This paper presents an application of statistical engineering to solve the problem of determining the effects of reducing test sample sizes and environment levels in lot acceptance testing (LAT) of ordnance devices used by NASA and DoD space systems. Unlike environmental testing of dedicated qualification hardware, ordnance devices have a test-like-you-fly exception and use lot acceptance sampling or LAT. LAT is performed by randomly selecting a predefined number of devices from an individual lot and exposing them to a more severe dynamic shock and vibration testing environments than flight (sometimes as high as 6 decibels over flight environments) and then performing a destructive test on the device. Recent trends have been suggested to reduce LAT costs by reducing environment test levels or the number of devices per LAT, or both. A method is given here to compute flight risk, so the proposed methods can be compared by subject matter experts to the baseline LAT methods. In addition, this method can be used to determine the best methods to include in future LAT standards for pyrotechnic devices.

Computing Risk↗

Evaluation of Naturally Occurring Be-7 Activity on LANL Stack Filter Clumps

Los Alamos National Laboratory (LANL) is responsible for providing solutions to challenging issues through multidisciplinary science, engineering, and technology that impact national security. As part of the Radioactive Air Emissions Management (RAEM) Team, it is our responsibility to ensure LANL operates within the requirements of the Code of Federal Regulations 40 CFR 61, Subpart H, National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities (Rad-NESHAP). The standard states, “Emissions of radionuclides to the ambient air from Department of Energy facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent of 10 mrem/yr” (EPA, 2002) During a routine assessment of LANL’s Rad-NESHAP compliance program, an opportunity for improvement was identified that addresses the evaluation of routine stack samples which potentially have naturally occurring radioactive materials (NORM) on the filter media. In the past and based on professional judgment, detections of NORM such as K-40 and Be-7 typically were rejected from the analytical results. The assessment finding suggested developing a technical criterion to ensure that such rejections were justified, comparing actual measured values with anticipated NORM concentrations for various stacks located at LANL. The significance of accepting or rejecting samples as “true” or “NORM” and its impact on the RAEM’s mission and compliance to the regulations is explained later in the document. Additionally, this document will describe the process and calculations for how such results are to be accepted as actual samples “true positive” or rejected as NORM.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

1000 Soils Pilot Dataset, version 8, May 2025

This record hosts data generated by the 1000 Soils Pilot. Data will be updated as more become available. Please see the most recent data upload for current data. A beta visualization tool is available for some data types at https://shinyproxy.emsl.pnnl.gov/app/1000soils. Please submit any suggestions or comments through the 'contact' tab. We are actively working to improve visualizations and value all feedback. Data completed include: Geochemistry, texture, respiration, and enzyme activities FTICR-MS organic matter chemistry Microbial biomass C and N TOC/TDN of water-extractable OM X-ray computed tomography (derived metrics available here, raw data available upon request) Metagenomes; a variety of data formats are available upon request Soil hydraulic properties Data in progress: LC-MS/MS in development, timeline TBD, inquire for status 1000S_processed_BGC_summary.csv contains all available biogeochemical data; microbial biomass C and N; and TOC/TDN of water-extractable OM; and 1000S_Tomography.xslx contains a summary of data generated via X-ray computed tomography. icr_v2_corems2.csv contains FTICR-MS data processed by CoreMS version 2. These data are merged by formula across instrument runs to enable cross-sample comparisons. Technical replicates are merged by retaining peaks present in 2 out of 3 replicates. 1000Soils_Metadata_Site_Mastersheet_v1.csv contains site information. Soil Hydraulics_corrected_02042025.xlsx contains soil hydraulics information. Readme File_v4.xlsx is the readme file. Please contact the MONet project (monet.emsl@pnnl.gov) or Emily Graham (emily.graham@pnnl.gov) with questions. The following file and all raw data are available upon request: icr_by_mass_for_single_sample_analysis_only.csv contains FTICR-MS data processed by CoreMS and is intended for usage in the calculation of biochemical transformations within samples only. These data are not acceptable for cross-sample comparison of masses because they are from multiple instrument runs. For more information, please see: https://www.emsl.pnnl.gov/monet and https://sc-data.emsl.pnnl.gov/monet Acknowledgment: Soil data were provided by the Molecular Observation Network (MONet) at the Environmental Molecular Sciences Laboratory (https://ror.org/04rc0xn13), a DOE Office of Science user facility sponsored by the Biological and Environmental Research program under Contract No. DE-AC05-76RL01830. The work (proposal: 10.46936/10.25585/60008970) conducted by the U.S. Department of Energy, Joint Genome Institute (https://ror.org/04xm1d337), a DOE Office of Science user facility, is supported by the Office of Science of the U.S. Department of Energy operated under Contract No. DE-AC02-05CH11231. The Molecular Observation Network (MONet) database is an open, FAIR, and publicly available compilation of the molecular and microstructural properties of soil. Data in the MONet open science database can be found at https://sc-data.emsl.pnnl.gov/.

biogeochemistry↗

Aircraft digital control design methods

Variations in design methods for aircraft digital flight control are evaluated and compared. The methods fall into two categories; those where the design is done in the continuous domain (or s plane) and those where the design is done in the discrete domain (or z plane). Design method fidelity is evaluated by examining closed loop root movement and the frequency response of the discretely controlled continuous aircraft. It was found that all methods provided acceptable performance for sample rates greater than 10 cps except the uncompensated s plane design method which was acceptable above 20 cps. A design procedure based on optimal control methods was proposed that provided the best fidelity at very slow sample rates and required no design iterations for changing sample rates.

Powell, J. D.↗

A comparison of digital flight control design methods

Many variations in design methods for aircraft digital flight control have been proposed in the literature. In general, the methods fall into two categories: those where the design is done in the continuous domain (or s-plane), and those where the design is done in the discrete domain (or z-plane). This paper evaluates several variations of each category and compares them for various flight control modes of the Langley TCV Boeing 737 aircraft. Design method fidelity is evaluated by examining closed loop root movement and the frequency response of the discretely controlled continuous aircraft. It was found that all methods provided acceptable performance for sample rates greater than 10 cps except the 'uncompensated s-plane design' method which was acceptable above 20 cps. A design procedure based on optimal control methods was proposed that provided the best fidelity at very slow sample rates and required no design iterations for changing sample rates.

Powell, J. D.↗

Saltstone third quarter calendar year 2019 (3QCY19) toxicity characteristic leaching procedure (TCLP) results

The aqueous waste from Tank 50 (salt solution) is sampled quarterly for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TAR-Z-00008, Revision 01, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the third quarter of calendar year 2019 (3QCY19). One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample”. Results from this technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Remediation (SRR). After a 28 day cure, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The 3QCY19 saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for a non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Saltstone First Quarter Calendar Year 2021 (1QCY21) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from Tank 50 (salt solution) is sampled quarterly for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z00023, Revision 0, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the first quarter of calendar year 2021(1QCY21). One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample”. Results from this technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Remediation (SRR). After at least 28 days cured, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The 1QCY21 saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for a non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Saltstone Third Quarter Calendar Year 2021 (3QCY21) Toxicity Characteristic Leading Procedure (TCLP) Results

The aqueous waste from Tank 50 (salt solution) is sampled quarterly for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00023, Revision 0, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the third quarter of calendar year 2021(3QCY21). One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample”. Results from this technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Remediation (SRR). After at least 28 days cured, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The 3QCY21 saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for a non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

January 2022 Semiannual Saltstone Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from Tank 50 (salt solution) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00025, Revision 0, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the January 2022 semiannual Toxicity Characteristic Leaching Procedure (TCLP) samples. One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample.” Results from this technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). After at least 28 days cured, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The January 2022 semiannual saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for a non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

July 2022 Semiannual Saltstone Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from Tank 50 (salt solution) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Salstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00025, Revision 0, two SDF waste form (salstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the July 2022 Semiannual Toxicity Characteristic Leaching Procedure (TCLP) samples. One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the "Cement-Free grout sample." Results from this technical report support Task 2: 'Grout Leaching Analyses' of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). After at least 28 days cured, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using Toxicity Characteristic Leaching Procedure (TCLP). The July 2022 semiannual salstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for the non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

January 2023 Semiannual Saltstone Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from Tank 50 (salt solution) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00027, Revision 0, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-area premix material for January 2023 semiannual Toxicity Characteristic Leaching Procedure (TCLP) samples. One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag, and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample.” Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). After at least 28 days cured, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The January 2023 semiannual saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Combination of Rejection Sampling with Biased Probability Density Sampling (with Special Comments on MCNP "Cookie Cutter" Rejection)

Sampling from biased probability densities and rejection sampling are both very common Monte Carlo techniques. As far as I know, the combination of sampling from a biased density and rejection sampling has not been developed. This note develops the theory for sampling from a biased density and then accepting or rejecting that sampling.

97 MATHEMATICS AND COMPUTING↗