Search NASA⌕ Search

SEARCH · Search NASA

Results for “accurate quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Developing Mass Spectrometry for Water Quantitation and Volatiles Analysis from In-Situ Regolith

With a revived focus to create a sustainable hu-man presence on the moon, and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential [1]. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable in-dependent operation of missions while reducing the dependence on the complex supply chain created between the Earth, the moon and Mars. One of the most critical resources that has been identified for ISRU on the lunar surface is water [2]. Water is a versatile resource that can be used in various space operations, such as ra-diation shielding and conversion to oxygen (O2) for propellant [3,4]. One of the most water rich resources is thought to be within the regolith lo-cated in the permanently shadowed regions (PSR) of the Moon; several upcoming missions, such as PRIME-1 and VIPER, are already sched-uled to confirm this hypothesis [5,6]. However, there are currently no missions planned to quanti-fy the abudance of water at these regions. The quantity of water contained in the ice will inform and help the development of future ISRU plants and operation. Water and other volatile gases can be detect-ed upon controlled heating of icy lunar regolith for an accurate quantification of water. This method is similar to thermogravimetric analysis, which was used to analyze Apollo lunar regolith sam-ples. However, losses via sublimation/evaporation or contamination may have occurred with the samples due to the transit and exposure to the terrestrial environment. Furthermore, water would not be expected for these samples since they were not collected from a PSR. Thus, for more accurate results, icy lunar regolith should be ana-lyzed in situ to provide the most representative composition of both water and other volatile gas-es. The Light Water Analysis and Volatile Extract (LightWAVE) project aims to address this knowledge gap. A system has been developed to collect, heat and analyze evolved gases from lu-nar regolith on the lunar surface. The gases will be analyzed by a modified commercial off the shelf (COTS) residual gas analyzer (RGA) quad-rupole mass spectrometer. Evolved gases from heated regolith samples can be identified by the observed mass-to-charge (m/z) ratios, and the peak intensities correlate to the abundances of the observed gases for quantitation. Therefore, our group is developing a calibration methodology utilizing a COTS RGA to quantitate water from in-situ regolith samples on the lunar surface. The partial pressure of water and ideal gas law will be used to quantify the total water evolved from a regolith sample. Here we present our methodol-ogy for the design and calibration for water quan-titation using a COTS RGA.

Nilab Azim↗

A combined experimental and modelling study of granite hydrothermal alteration

Geochemical reactions can induce significant changes of rock reservoir porosity and permeability via mineral dissolution and precipitation processes, affecting the long-term fluid behaviour within various geological systems. Here, the understanding and quantification of these reactions rely on field and experimental studies and on the predictions of reactive transport models. The present study was aimed at assessing the extent to which current geochemical models integrating available mineral dissolution/precipitation rate equations can reproduce the experimental data obtained from 4 to 17-day long hydrothermal alteration experiments of a muscovite-biotite granite and, thus, help provide an accurate description of the evolution of geothermal systems within granitic reservoirs. The experiments were conducted at a constant temperature of 180 °C and over an aqueous fluid pH range of 2 to 8.5, using both mixed-flow and static batch reactors. Modelled major element (K, Al, Si, Ca, and Mg) concentrations were generally in satisfactory agreement with the corresponding measured elemental fluxes – the differences between modelled and experimental values were generally within a factor of 5 – and the predicted identity and mass of formed secondary phases were consistent with the microscopic observations of the reacted solids. However, larger differences between measured and modelled element concentrations were observed when significant amounts of secondary phases formed, notably at pH 2 to 3, and for longer-term batch experiments. Much of this concentration difference stems from the underestimation of the amounts of Al-phases formed at acid to near-neutral pH. Although an idealized rock composition was considered, the observed mismatch between model calculations and experimental data can be attributed to inadequate mineral precipitation reaction rates and a poor description of reactive surface areas in existing geochemical modelling codes. More accurate quantification of precipitation kinetics, including nucleation and growth, and improved descriptions of the temporal change of mineral surface area would enhance the predictive capabilities of reactive transport models and benefit, particularly, the efforts aimed at increasing the sustainability of EGS reservoirs.

58 GEOSCIENCES↗

Importance of hydrogen oxidation reaction current in quantifying hydrogen crossover in PEM water electrolyzers at high differential pressure

Understanding hydrogen permeation in proton exchange membrane water electrolyzers (PEMWEs) operating at high differential pressures (>25 bar) is critical towards developing effective gas recombination strategies that enable safe operation and high efficiency. Developing this understanding relies on accurate quantification of hydrogen crossover rates in water electrolyzers operating under such conditions. In this work, we show that PEMWEs operating at high differential pressures exhibit noticeable hydrogen oxidation reaction (HOR) currents. As the HOR consumes part of the permeated hydrogen at the anode, neglecting HOR currents leads to severe underestimation of the hydrogen crossover rate. We implemented a new method combining hydrogen oxidation current with online gas chromatography measurements to accurately quantify hydrogen crossover rates as a function of operating current density in PEMWEs operating at high differential pressures (10–30 bar g ).

25 ENERGY STORAGE↗

Expediting SRM assay development for large-scale targeted proteomics experiments

Due to their high sensitivity and specificity, targeted proteomics measurements, e.g. selected reaction monitoring (SRM), are becoming increasingly popular for biological and translational applications. Selection of optimal transitions and optimization of collision energy (CE) are important assay development steps for achieving sensitive detection and accurate quantification; however, these steps can be labor-intensive, especially for large-scale applications. Herein, we explored several options for accelerating SRM assay development evaluated in the context of a relatively large set of 215 synthetic peptide targets. We first showed that HCD fragmentation is very similar to CID in triple quadrupole (QQQ) instrumentation, and by selection of top six y fragment ions from HCD spectra, >86% of top transitions optimized from direct infusion on QQQ instrument are covered. We also demonstrated that the CE calculated by existing prediction tools was less accurate for +3 precursors, and a significant increase in intensity for transitions could be obtained using a new CE prediction equation constructed from the present experimental data. Overall, our study illustrates the feasibility of expediting the development of larger numbers of high-sensitivity SRM assays through automation of transitions selection and accurate prediction of optimal CE to improve both SRM throughput and measurement quality.

59 BASIC BIOLOGICAL SCIENCES↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

Automated noninvasive classification of renal cancer on multiphase CT

Purpose: To explore the added value of the shape of renal lesions for classifying renal neoplasms. To investigate the potential of computer-aided analysis of contrast-enhanced computed-tomography (CT) to quantify and classify renal lesions. Methods: A computer-aided clinical tool based on adaptive level sets was employed to analyze 125 renal lesions from contrast-enhanced abdominal CT studies of 43 patients. There were 47 cysts and 78 neoplasms: 22 Von Hippel-Lindau (VHL), 16 Birt-Hogg-Dube (BHD), 19 hereditary papillary renal carcinomas (HPRC), and 21 hereditary leiomyomatosis and renal cell cancers (HLRCC). The technique quantified the three-dimensional size and enhancement of lesions. Intrapatient and interphase registration facilitated the study of lesion serial enhancement. The histograms of curvature-related features were used to classify the lesion types. The areas under the curve (AUC) were calculated for receiver operating characteristic curves. Results: Tumors were robustly segmented with 0.80 overlap (0.98 correlation) between manual and semi-automated quantifications. The method further identified morphological discrepancies between the types of lesions. The classification based on lesion appearance, enhancement and morphology between cysts and cancers showed AUC = 0.98; for BHD + VHL (solid cancers) vs. HPRC + HLRCC AUC = 0.99; for VHL vs. BHD AUC = 0.82; and for HPRC vs. HLRCC AUC = 0.84. All semi-automated classifications were statistically significant (p < 0.05) and superior to the analyses based solely on serial enhancement. Conclusions: The computer-aided clinical tool allowed the accurate quantification of cystic, solid, and mixed renal tumors. Cancer types were classified into four categories using their shape and enhancement. Comprehensive imaging biomarkers of renal neoplasms on abdominal CT may facilitate their noninvasive classification, guide clinical management, and monitor responses to drugs or interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-207B-04: Quantitative Contrast-Enhanced Spectral Mammography Based On Photon-Counting Detectors: A Feasibility Study

Purpose: To investigate the feasibility of accurate quantification of iodine mass thickness in contrast-enhanced spectral mammography. Methods: Experimental phantom studies were performed on a spectral mammography system based on Si strip photon-counting detectors. Dual-energy images were acquired using 40 kVp and a splitting energy of 34 keV with 3 mm Al pre-filtration. The initial calibration was done with glandular and adipose tissue equivalent phantoms of uniform thicknesses and iodine disk phantoms of various concentrations. A secondary calibration was carried out using the iodine signal obtained from the dual-energy decomposed images and the known background phantom thicknesses and densities. The iodine signal quantification method was validated using phantoms composed of a mixture of glandular and adipose materials, for various breast thicknesses and densities. Finally, the traditional dual-energy weighted subtraction method was also studied as a comparison. The measured iodine signal from both methods was compared to the known iodine concentrations of the disk phantoms to characterize the quantification accuracy. Results: There was good agreement between the iodine mass thicknesses measured using the proposed method and the known values. The root-mean-square (RMS) error was estimated to be 0.2 mg/cm2. The traditional weighted subtraction method also predicted a linear correlation between the measured signal and the known iodine mass thickness. However, the correlation slope and offset values were strongly dependent on the total breast thickness and density. Conclusion: The results of the current study suggest that iodine mass thickness can be accurately quantified with contrast-enhanced spectral mammography. The quantitative information can potentially improve the differentiation between benign and malignant legions. Grant funding from Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

Carrier-assisted One-pot Sample Preparation for Targeted Proteomics Analysis of Small Numbers of Human Cells

Protein analysis of small numbers of human cells is primarily achieved by targeted proteomics with antibody-based immunoassays, which have inherent limitations (e.g., low multiplex and unavailability of antibodies for new proteins). Mass spectrometry (MS)-based targeted proteomics has emerged as an alternative because it is antibody-free, high multiplex, and has high specificity and quantitation accuracy. Recent advances in MS instrumentation make MS-based targeted proteomics possible for multiplexed quantification of highly abundant proteins in single cells. However, there is a technical challenge for effective processing of single cells with minimal sample loss for MS analysis. To address this issue, we have recently developed a convenient protein carrier-assisted one-pot sample preparation coupled with liquid chromatography (LC) - selected reaction monitoring (SRM) termed cLC-SRM for targeted proteomics analysis of small numbers of human cells. This method capitalizes on using the combined excessive exogenous protein as a carrier and low-volume one-pot processing to greatly reduce surface adsorption losses as well as high-specificity LC-SRM to effectively address the increased dynamic concentration range due to the addition of exogeneous carrier protein. Its utility has been demonstrated by accurate quantification of most moderately abundant proteins in small numbers of cells (e.g., 10-100 cells) and highly abundant proteins in single cells. The easy-to-implement features and no need for specific devices make this method readily accessible to most proteomics laboratories. In this study, we have provided a detailed protocol for cLC-SRM analysis of small numbers of human cells including cell sorting, cell lysis and digestion, LC-SRM analysis, and data analysis. Further improvements in detection sensitivity and sample throughput are needed towards targeted single-cell proteomics analysis. We anticipate that cLC-SRM will be broadly applied to biomedical research and systems biology with the potential of facilitating precision medicine.

60 APPLIED LIFE SCIENCES↗

Intrinsic Kinetics of Polyethylene Terephthalate Pyrolysis via Micropyrolysis and Multivariate Chromatographic Analysis

This study provides an in-depth investigation of the primary decomposition of polyethylene terephthalate (PET) via pyrolysis, employing an experimental-analytic workflow that integrates design of experiments (DoE), micropyrolysis coupled with comprehensive two-dimensional gas chromatography (GC×GC), and multivariate data analysis to verify intrinsic kinetic conditions and elucidate evolving product distributions for mapping key reaction pathways. Peaks that could not be identified using commercial spectral libraries were assigned using Mass Frontier simulations, enabling the identification of divinyl terephthalate, ethyl vinyl terephthalate, and 2-(benzoyloxy)ethyl vinyl terephthalate. A polar×polar (non-orthogonal) column set tailored for the detection of carboxylic acids enhanced the quantification of benzoic acid, 4-vinylbenzoic acid, 4-ethylbenzoic acid, and methylbenzoic acid by up to 6-fold relative to an orthogonal column combination (non-polar×mid-polar). Moreover, pyrolysis variables were systematically evaluated using a Box- Behnken design (BBD), encompassing pyrolysis temperature (500−600 °C), sample weight (50−150 μg), and carrier gas flow rate (100−300 mL min −1 ). Among these, pyrolysis temperature was the only statistically significant factor influencing product yields, ranging from 58.78 to 84.26 wt %. In contrast, neither the sample weight nor the carrier gas flow rate had a significant effect on product yields within the evaluated experimental space. At 600 °C, the major pyrolysis products were benzoic acid (up to 20.20 ± 1.46 wt %) and CO 2 (up to 21.28 ± 1.46 wt %), which can be produced through decarboxylation reactions. These findings underscore the critical importance of selecting appropriate analytical columns for the accurate quantification of heteroatomcontaining products such as carboxylic acids, which may otherwise be underestimated or undetected due to their reactivity with the stationary phase of non-polar and mid-polar columns, as well as other GC components. They also highlight the importance of selecting pyrolysis conditions for investigating the primary decomposition of PET under an isothermal kinetically limited regime.

aromatic compounds↗

Impact of duration and missing data on the long-term photovoltaic degradation rate estimation

Accurate quantification of photovoltaic (PV) system degradation rate (R D ) is essential for lifetime yield predictions. Although R D is a critical parameter, its estimation lacks a standardized methodology that can be applied on outdoor field data. The purpose of this paper is to investigate the impact of time period duration and missing data on R D by analyzing the performance of different techniques applied to synthetic PV system data at different linear R D patterns and known noise conditions. The analysis includes the application of different techniques to a 10-year synthetic dataset of a crystalline Silicon PV system, with emulated degradation levels and imputed missing data. Here, the analysis demonstrated that the accuracy of ordinary least squares (OLS), year-on-year (YOY), autoregressive integrated moving average (ARIMA) and robust principal component analysis (RPCA) techniques is affected by the evaluation duration with all techniques converging to lower R D deviations over the 10-year evaluation, apart from RPCA at high degradation levels. Moreover, the estimated R D is strongly affected by the amount of missing data. Filtering out the corrupted data yielded more accurate R D results for all techniques. It is proven that the application of a change-point detection stage is necessary and guidelines for accurate R D estimation are provided.

14 SOLAR ENERGY↗

Quantifying Caloric Expenditure During Zero-G Exercise

BACKGROUND: Exercise is a fundamental component of maintaining astronaut health on long-duration space missions, where the microgravity environment poses unique challenges to physiological homeostasis. Accurate quantification of energy expenditure during such exercises is crucial for optimizing nutritional and physical health strategies for spacefarers. OBJECTIVE: This study aims to develop a comprehensive model to estimate caloric expenditure during exercise in a microgravity environment, employing a combination of spirometry, heart rate data, and other relevant parameters. By assessing energy utilization under these conditions, we seek to facilitate enhanced health management protocols for astronauts in space. METHODS & OUTCOMES: A multivariate predictive model will be constructed, utilizing spirometry and heart rate data, coupled with additional physiological and environmental parameters. A systematic approach will be applied to analyze the relationship between these variables and energy expenditure during various exercises. The proposed model will subsequently undergo rigorous validation to ensure accuracy and reliability. This research is expected to yield a precise and reliable predictive model, contributing to improved strategies for exercise prescription and nutritional intake, addressing the unique challenges presented by microgravity environments. We anticipate that our findings will support the development of more effective health maintenance protocols for astronauts during extended space missions, mitigating the adverse effects of space travel on the human body. SIGNIFICANCE: The development of an accurate and adaptable model to quantify caloric expenditure during exercise in space represents a pivotal advancement in space medicine. The insights gained from this study have the potential to inform the design of enhanced health and wellness strategies, ensuring the well-being and operational effectiveness of astronauts in long-duration space missions.

Calorie↗

Estimating the Performance Loss Rate of Photovoltaic Systems Using Time Series Change Point Analysis

The accurate quantification of the performance loss rate of photovoltaic systems is critical for project economics. Following the current research activities in the photovoltaic performance and reliability field, this work presents a comparative assessment between common change point methods for performance loss rate estimation of fielded photovoltaic installations. An extensive testing campaign was thus performed to evaluate time series analysis approaches for performance loss rate evaluation of photovoltaic systems. Historical electrical data from eleven photovoltaic systems installed in Nicosia, Cyprus, and the locations’ meteorological measurements over a period of 8 years were used for this investigation. The application of change point detection algorithms on the constructed monthly photovoltaic performance ratio series revealed that the obtained trend might not always be linear. Specifically, thin film photovoltaic systems showed nonlinear behavior, while nonlinearities were also detected for some crystalline silicon photovoltaic systems. When applying several change point techniques, different numbers and locations of changes were detected, resulting in different performance loss rate values (varying by up to 0.85%/year even for the same number of change points). The results highlighted the importance of the application of nonlinear techniques and the need to extract a robust nonlinear model for detecting significant changes in time series data and estimating accurately the performance loss rate of photovoltaic installations.

photovoltaics↗

Limitations of Rb-82 weight-adjusted dosing accuracy at low doses

Introduction: Weight-adjusted dosing is important to maintain accurate quantification for dynamic cardiac three-dimensional positron emission tomography (PET). However, the manufacturer of the only Food and Drug Administration approved rubidium-82 (Rb-82) generator (CardioGen-82, Bracco Diagnostics, Inc.) recommends recalibration after each change in dose which is inefficient in a busy clinical PET lab. The objective of this study was to evaluate the accuracy of Rb-82 dosing without this recalibration. Methods: After daily calibration to either 30 mCi (1110 MBq) or 12 mCi (444 MBq), Rb-82 doses between 6 and 45 mCi (222-1665 MBq) were eluted and measured on an external dose calibrator. This was repeated for four generators at weeks 1, 2, or 4 of the generator cycle. The measurements were compared with values reported by the infusion system. Results: For requested doses less than 30 mCi, the measured dose was consistently lower than the requested dose, ranging from −3.2 mCi at 25 mCi to −5.5 mCi at 10 mCi. The error exceeded 10% for doses less than or equal to 26 mCi for the 30 mCi calibration. Residual activity in the infusion system dead volume accounted for the discrepancy between requested and delivered doses for calibration to 30 mCi but not 12 mCi. Conclusions: The CardioGen-82 infusion system is capable of accurate weight-adjusted doses without recalibration for Rb-82 doses as low as 26 mCi when calibrated to 30 mCi. For doses less than 26 mCi, the generator-reported residual activity within the infusion system can be used to correct the delivered dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-scale geospatial agroecosystem modeling: a case study on the influence of soil data resolution on carbon budget estimates

The development of effective measures to stabilize atmospheric CO2 concentration and mitigate negative impacts of climate change requires accurate quantification of the spatial variation and magnitude of the terrestrial carbon (C) flux. However, the spatial pattern and strength of terrestrial C sinks and sources remain uncertain. In this study, we designed a spatially-explicit agroecosystem modeling system by integrating the Environmental Policy Integrated Climate (EPIC) model with multiple sources of geospatial and surveyed datasets (including crop type map, elevation, climate forcing, fertilizer application, tillage type and distribution, and crop planting and harvesting date), and applied it to examine the sensitivity of cropland C flux simulations to two widely used soil databases (i.e. State Soil Geographic-STATSGO of a scale of 1:250,000 and Soil Survey Geographic-SSURGO of a scale of 1:24,000) in Iowa, USA. To efficiently execute numerous EPIC runs resulting from the use of high resolution spatial data (56m), we developed a parallelized version of EPIC. Both STATSGO and SSURGO led to similar simulations of crop yields and Net Ecosystem Production (NEP) estimates at the State level. However, substantial differences were observed at the county and sub-county (grid) levels. In general, the fine resolution SSURGO data outperformed the coarse resolution STATSGO data for county-scale crop-yield simulation, and within STATSGO, the area-weighted approach provided more accurate results. Further analysis showed that spatial distribution and magnitude of simulated NEP were more sensitive to the resolution difference between SSURGO and STATSGO at the county or grid scale. For over 60% of the cropland areas in Iowa, the deviations between STATSGO- and SSURGO-derived NEP were larger than 1MgCha(-1)yr(-1), or about half of the average cropland NEP, highlighting the significant uncertainty in spatial distribution and magnitude of simulated C fluxes resulting from differences in soil data resolution.

Climate change, EPIC, Net Ecosystem Production, Pa↗

Rapid and sensitive gas chromatography ion-trap mass spectrometry method for the determination of tobacco specific N-nitrosamines in secondhand smoke

Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs in both the gas- and particle-phase of secondhand smoke (SHS) using gas chromatography and ion-trap tandem mass spectrometry,. A smoking machine in an 18-m3 room-sized chamber generated relevant concentrations of SHS that were actively sampled on Teflon coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid-liquid extraction protocol using methanol as solvent was successfully applied to both filters with high recoveries ranging from 85 to 115percent. Tandem MS parameters were optimized to obtain the best sensitivity in terms of signal to-noise ratio (S/N) for the target compounds. For each TSNA, the major fragmentation pathways as well as ion structures were elucidated and compared with previously published data. The method showed excellent performances with a linear dynamic range between 2 and 1000 ng mL-1, low detection limits (S/N> 3) of 30-300 pg.ml-1 and precision with experimental errors below 10percent for all compounds. Moreover, no interfering peaks were observed indicating a high selectivity of MS/MS without the need for a sample clean up step. The sampling and analysis method provides a sensitive and accurate tool to detect and quantify traces of TSNA in SHS polluted indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing subsurface analysis: Integrating computer vision and deep learning for the near real-time interpretation of borehole image logs in the Illinois Basin-Decatur Project

The accurate quantification and mapping of subsurface natural fracture systems using borehole imaging logs are critical for the success of CO 2 sequestration in geologic formations, optimization of engineered geothermal systems, and hydrocarbon production enhancement. However, traditional interpretation processes suffer from time-consuming procedures and human bias. To address these challenges and expedite fracture analysis, we investigated the application of integrated computer vision and DL workflows to automate image log analysis. Specifically, the design of our workflow was crafted to swiftly detect fractures and baffles by using actual electrical resistivity of borehole wall from microresistivity imaging device alongside their binary representation. This novel approach significantly reduces computational time while providing invaluable insights. By incorporating conventional logging and microseismic data, we present a regional subsurface natural fracture mapping technique. Through the minimization of human bias in image log analysis, our automated workflow achieves reduced fracture interpretation time and costs while ensuring robust and reproducible results. We demonstrated the efficacy of our approach by applying the workflow to the Illinois Basin-Decatur Project site. The automated workflow successfully identified major fractured zones, multiple baffles, and an interbedded layer with a high resolution of 0.01 ft or 0.12 in. (0.3 cm) and can be upscaled to any desired resolution. Validation through microseismic and image log interpretations allows for accurate and near-real-time mapping of fractures and baffles, significantly enhancing CO 2 pressure forecasting and postinjection site care. Our approach stands out due to its robustness, consistency, and reduced computational cost compared with alternative feature extraction technologies. It presents exciting possibilities for advancing CO 2 sequestration and engineered geothermal efforts by offering comprehensive and efficient fracture mapping solutions. This technology can contribute significantly to the optimization of CO 2 sequestration projects, facilitating sustainable environmental practices, and combating climate change.

Geochemistry & Geophysics↗

Analyzing Solutions High in Total Dissolved Solids for Rare Earth Elements (REEs) Using Cation Exchange and Online Pre-Concentration with the seaFAST2 Unit; NETL-TRS-7-2017; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Albany, OR, 2017; p 32

The accurate quantification of the rare earth element (REE) dissolved concentrations in natural waters are often inhibited by their low abundances in relation to other dissolved constituents such as alkali, alkaline earth elements, and dissolved solids. The high abundance of these constituents can suppress the overall analytical signal as well as create isobaric interferences on the REEs during analysis. Waters associated with natural gas operations on black shale plays are characterized by high salinities and high total dissolved solids (TDS) contents >150,000 mg/L. Methods used to isolate and quantify dissolved REEs in seawater were adapted in order to develop the capability of analyzing REEs in waters that are high in TDS. First, a synthetic fluid based on geochemical modelling of natural brine formation fluids was created within the Marcellus black shale with a TDS loading of 153,000 mg/L. To this solution, 1,000 ng/mL of REE standards was added based on preliminary analyses of experimental fluids reacted at high pressure and temperature with Marcellus black shale. These synthetic fluids were then run at three different dilution levels of 10, 100, and 1,000–fold dilutions through cation exchange columns using AG50-X8 exchange resin from Eichrom Industries. The eluent from the cation columns were then sent through a seaFAST2 unit directly connected to an inductively coupled plasma mass spectrometer (ICP-MS) to analyze the REEs. Percent recoveries of the REEs ranged from 80–110% and fell within error for the external reference standard used and no signal suppression or isobaric interferences on the REEs were observed. These results demonstrate that a combined use of cation exchange columns and seaFAST2 instrumentation are effective in accurately quantifying the dissolved REEs in fluids that are >150,000 mg/L in TDS and have Ba:Eu ratios in excess of 380,000.

03 NATURAL GAS↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗