Search NASA⌕ Search

SEARCH · Search NASA

Results for “active filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analytic redundancy management for large flexible structures

An analytic redundancy management approach for on-line component failure detection is described and illustrated using a simulation of the NASA Langley Spacecaft Control Laboratory Experiment (SCOLE) research facility. The SCOLE experimental apparatus simulated is a functional model of the Space Shuttle with a large, flexible, offset-feed antenna cantilevered from the payload bay. This approach uses a single, active, Kalman filter selected from a bank of filters, each element of which was previously designed to accommodate a specific failure condition. The residuals of this active filter are processed through a sequential probability ratio test (SPRT) filter to identify the failure state of the system and, hence, closing the failure accommodation loop, to select the active filter. Results are presented that illustrate the ability of the system to detect and recover from failures introduced in the angular rate and linear acceleration sensors on the SCOLE facility.

Shenhar, J.↗

Design of high pressure oxygen filter for extravehicular activity life support system, volume 1

The experience of the National Aeronautics and Space Administration (NASA) with extravehicular activity life support emergency oxygen supply subsystems has shown a large number of problems associated with particulate contamination. These problems have resulted in failures of high pressure oxygen component sealing surfaces. A high pressure oxygen filter was designed which would (a) control the particulate contamination level in the oxygen system to a five-micron glass bead rating, ten-micron absolute condition (b) withstand the dynamic shock condition resulting from the sudden opening of 8000 psi oxygen system shutoff valve. Results of the following program tasks are reported: (1) contaminant source identification tests, (2) dynamic system tests, (3) high pressure oxygen filter concept evaluation, (4) design, (5) fabrication, (6) test, and (7) application demonstration.

Wilson, B. A.↗

Robust Kalman filter design for active flutter suppression systems

Additional insight is provided into the use of the Doyle-Stein (1979, 1981) technique in aeroelastic control problems by examining the application of the method to a flutter control problem. The system to be controlled consists of a full-size wind tunnel model of a wing, plus an aileron, an actuator, and an accelerometer used to sense the motion of the wing. A full-state feedback controller was designed using linear optimal control theory, and a Kalman filter was used in the feedback loop for state estimation. The filter design procedure is explained along with that to improve closed-loop properties of the system. The locus of the poles of the filter is examined as a scalar design parameter is varied. The Doyle-Stein design procedure is shown to substantially improve the stability properties of an active flutter controller designed using the linear quadratic Gaussian control theory.

Garrard, W. L.↗

Active resistance capacitance filter design

Filters, formed by combinations of distributed RC elements with positive-feedback voltage amplifiers, provide transfer functions similar to those the heavier LC filters ordinarily employ. They also provide signal amplification.

Kerwin, W. J.↗

Actively Pumped Optical Filters at 532 nm

The operation of two narrow-band optical filters at 532.33 nm is presented. Both of these filters operate on the 4P(sub 1/2) to 8S(sub 1/2) excited-state transition in potassium vapor. One of the filters is based on excited-state Faraday effect, and requires the application of an external axial magnetic field. The peak transmission of this filter is approximately 3.5% with a linewidth of less than 10 GHz. The second filter does not require a magnetic field for its operation, but readily attains peak transmissions of 25-30%. The 4P(sub 1/2) state is excited by a 769.9 nm light pulse which is linearly polarized for the first scheme and circularly polarized for the second.

Billmers, Richard I.↗

Multichannel, Active Low-Pass Filters

Multichannel integrated circuits cascaded to obtain matched characteristics. Gain and phase characteristics of channels of multichannel, multistage, active, low-pass filter matched by making filter of cascaded multichannel integrated-circuit operational amplifiers. Concept takes advantage of inherent equality of electrical characteristics of nominally-identical circuit elements made on same integrated-circuit chip. Characteristics of channels vary identically with changes in temperature. If additional matched channels needed, chips containing more than two operational amplifiers apiece (e.g., commercial quad operational amplifliers) used. Concept applicable to variety of equipment requiring matched gain and phase in multiple channels - radar, test instruments, communication circuits, and equipment for electronic countermeasures.

Lev, James J.↗

Testing of the ISS’s Charcoal HEPA Integrated Particle Scrubber (CHIPS) Filters to Ascertain an Efficiency Curve and Most Penetrating Particle Size

High air quality is a top priority in hermetically sealed environments, such as the International Space Station (ISS). Aerosol particulate filtration on the ISS is achieved via 21 HEPA filters. Traditional HEPA filters have an efficiency of 99.97%, but HEPA filters aboard the ISS have been found to achieve 99.99% efficiency. This may be due to the flight-grade HEPA filters chosen or, less likely, that they are combined with activated charcoal filters for siloxane removal in a combination referred to as Charcoal HEPA Integrated Particle Scrubbers (CHIPS) filters. All filters have a Most Penetrating Particle Size (MPPS), but, until now, the MPPS and efficiency curve of the CHIPS filters was not known. The efficiency curve of the CHIPS filters was ascertained at NASA Glenn Research Center through standard salt crystal aerosolization. This method was selected over aerosolized oil droplets due to a desire to preserve the filter’s function for further testing. The CHIPS filters were tested as they are oriented on the ISS (activated charcoal filter followed by a flight-grade HEPA filter), with the HEPA portion alone, and with the activated charcoal portion alone. The results of this experiment are generally useful but can be especially useful for the microbiology and Environmental Control and Life Support Systems (ECLSS). This is due to microbial contamination being a potential concern in the air revitalization systems on the ISS. Knowing the MMPS of the CHIPS filters, in conjunction with levels of airborne microbes, is useful for predicting which and how many microbes are likely to get through the HEPA filters that sit in the beginning of the ISS airstream. It may also be useful to other groups at NASA to know how many particulates are able to pass through high-efficiency filtration, and even for healthcare cleanrooms and other air purification pursuits.

A Nicolas Whitlock↗

Evaluation and Certification of Ambersorb 4652 for use in Activated Carbon Ion Exchange Filters for the International Space Station

In order to reduce the infiltration of dimethylsilanediol (DMSD) and other organosilicon containing species through the Multifiltration Beds (MF Beds), an alternate activated carbon was found to replace the obsolete Barnabey Cheney 580-26 activated carbon. The carbon that removed the most organosilicon compounds in testing1 was a synthetic activated carbon named Schunk 4652 which later became Ambersorb 4652. Since activated carbon has a large capacity for iodine (I2), and is used in the Activated Carbon Ion Exchange (ACTEX) filters on the International Space Station (ISS), testing was performed on the Ambersorb 4652 carbon to determine the effectiveness of the material for use in ACTEX filters to remove iodine. This work summarizes the testing and the certification of Ambersorb 4652 for use in the ACTEX filters for the ISS.

Adam, Niklas↗

Interior Landscape Plants for Indoor Air Pollution Abatement

In this study, the leaves, roots, soil, and associated microorganisms of plants have been evaluated as a possible means of reducing indoor air pollutants. Additionally, a novel approach of using plant systems for removing high concentrations of indoor air pollutants such as cigarette smoke, organic solvents, and possibly radon has been designed from this work. This air filter design combines plants with an activated carbon filter. The rationale for this design, which evolved from wastewater treatment studies, is based on moving large volumes of contaminated air through an activated carbon bed where smoke, organic chemicals, pathogenic microorganisms (if present), and possibly radon are absorbed by the carbon filter. Plant roots and their associated microorganisms then destroy the pathogenic viruses, bacteria, and the organic chemicals, eventually converting all of these air pollutants into new plant tissue. It is believed that the decayed radon products would be taken up the plant roots and retained in the plant tissue.

Wolverton, B. C.↗

JPL activities on development of acousto-optic tunable filter imaging spectrometer

Recent activities of JPL in the development of a new type of imaging spectrometers for earth observation and planetary exploration are reported. This instrument uses the acousto-optic tunable filter (AOTF) as high resolution and fast programmable bandpass filter. AOTF operates in the principle of acousto-optic interaction in an anisotropic medium. This filter can be tuned in sequential, random, and multiwavelength access modes, providing observational flexibility. The diffraction process in the filter generates two diffracted monochromatic beams with polarization orthogonal to each other, creating a unique capability to measure both polarimetric and spectral properties of the incoming light simultaneously with a single instrument. The device gives wide wavelength operations with reasonably large throughput. In addition, it is in a compact solid-state structure without moving parts, providing system reliability. These attractive features give promising opportunities to develop a new generation of airborne/spaceborne and ground, real-time, imaging spectrometer systems for remote sensing applications.

Cheng, Li-Jen↗

Active flutter suppression using dipole filters

By using traditional control concepts of gain root locus, the active suppression of a flutter mode of a flexible wing is examined. It is shown that the attraction of the unstable mode towards a critical system zero determines the degree to which the flutter mode can be stabilized. For control situations where the critical zero is adversely placed in the complex plane, a novel compensation scheme called a 'Dipole' filter is proposed. This filter ensures that the flutter mode is stabilized with acceptable control energy. The control strategy is illustrated by designing flutter suppression laws for an active flexible wing (AFW) wind-tunnel model, where minimal control effort solutions are mandated by control rate saturation problems caused by wind-tunnel turbulence.

Srinathkumar, S.↗

Phycomyces in space: A problem in bioengineering

Sustaining life with total automation is a difficult problem for GAS canisters. The length of time between setting the experiment and flight, the conditions of a completely sealed container, no guarantee on launch delay, orientation and the possibility of contamination all tend to exclude experiments with living matter. This experiment examines the growth of a nontoxic, everyday fungus, Phycomyces, in a microgravity environment. Data from this experiment will help define the mechanism by which plants determine the direction of gravity. The bioengineering problems were solved only after numerous tests and design changes. Phycomyces normally have a shelf life of approximately one week. Storing the fungus for two months, activating the fungus for growth and precise timing were the major obstacles. Solutions were found for storage by drying the fungus spores onto pieces of filter paper. Activation occurs when this filter paper is dropped onto the growth medium, via a solenoid system. The problem of timing is partially solved by growing more than one chamber of the fungus at different time intervals. This experiment proves that the simpler a design, the better it works.

Schneringer, Julie A.↗

Surgical suite environmental control system

Theoretical and experimental work for a systems analysis approach to the problem of surgical suit exhaust systems centered on evaluation of halothane absorbing filters. An activated charcoal-alumina-charcoal combination proved to be the best filter for eliminating halothane through multilayer absorption of gas molecules.

Higginbotham, E. J.↗