At least 55 records · Page 3

Optimization of fluorescence and surface adsorption of citric acid/ethanolamine carbon nanoparticles for subsurface tracers

The tunable fluorescence and biocompatibility of fluorescent carbon nanoparticles (FCNs) makes them appealing tracers in geothermal, environmental, and clinical applications. Here, we address FCNs synthesized from reaction and pyrolysis of citric acid and ethanolamine. We examine the fluorescence and the adsorption of these FCNs as critical parameters that influence their use in applications. FCN fluorescence was observed to develop during pyrolysis and measured at pyrolysis temperatures ranging from 190 to 250 °C. Transmission electron microscopy shows that the FCN average diameter of approximately 13 nm is unaffected by pyrolysis temperature. However, pyrolysis temperature strongly affects fluorescence, which peaks at 210 °C. Here, the surface hydrophobicity of the FCNs increases with pyrolysis temperature as measured by retention on reverse phase chromatography. Together, these results suggest that particle surface functionalities provide both fluorescence and hydrophilicity, and that these surface functionalities are destroyed with excessive pyrolysis. To examine their surface adsorption, quartz crystal microbalance measurements demonstrate that pyrolysis temperature increases FCN adsorption on mineral surfaces. Surfaces with greater hydrophobicity show greater FCN adsorption. Adsorption is unaffected by the presence of mono- or divalent ions in solution. This suggests adsorption by hydrophobic interaction for the Fe 2 O 3 , SiO 2 , and AlSiO surfaces studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorptive denitrogenation of model aviation fuel using mesoporous silica in a packed bed adsorption system

This study aims to understand the effects of system process parameters such as flow rate, adsorbent particle size, and use of recycled adsorbent on denitrogenation performance of a model fuel using mesoporous silica gel. The goal is to reduce the nitrogen content of the model fuel from 1500 parts per million to single-digit ppm to meet ASTM specifications for drop-in fuels. This work was done with the intent of applying adsorptive denitrogenation to sustainable aviation fuel (SAF) product fractions produced via hydrothermal liquefaction (HTL). The adsorption performance of the silica is evaluated via packed column breakthrough data, with data generated from collecting from the column outlet and quantifying nitrogen content via gas chromatography. Select experiments use a significantly larger (2.5x column diameter and length) column to demonstrate linear scalability of the process. Thermogravimetric analysis data is collected to evaluate the effects of thermal calcination as a sorbent regeneration method. Effects of a more complex feed are also investigated using a known reference fuel with additional added nitrogen containing compounds. The results presented in this work successfully demonstrate up to 99.8 % removal of NCCs from a model fuel fraction at an original NCC concentration of approximately 1500 ppm to single-digit parts per million after treatment. We also examine calcination of sorbent materials to remove the adsorbed species to enable sorbent reuse and minimize waste generation and show that the calcined material can be reused up to 5 cycles with reduced adsorption capacity. Overall, this work indicates that adsorptive denitrogenation using silica gel is a viable solution to enable the integration of HTL-derived aviation fuels into existing fuel infrastructure.

Adsorption techniques↗

Contrasting Effects of Catecholate and Hydroxamate Siderophores on Molybdenite Dissolution

Molybdenum (Mo) is essential for many enzymes but is often sequestered within minerals, rendering it not readily bioavailable. Metallophores, metabolites secreted by microorganisms and plants, promote mineral dissolution to increase metal bioavailability. However, interactions between metallophores and Mo-bearing minerals remain unclear. Here, in this study, catecholate protochelin and hydroxamate desferrioxamine B (DFOB) were utilized to examine their effects on dissolution of the common Mo-bearing mineral, molybdenite (MoS 2 ), under both oxic and anoxic conditions. Protochelin promoted molybdenite dissolution under oxic conditions with the formation of MoO 3 on the surface and Mo-siderophore complexes in solution. This was attributed to air-oxidation of both molybdenite and protochelin, as evidenced by lack of dissolution under anoxic conditions but enhanced dissolution by either pre-oxidized protochelin or pre-oxidized molybdenite. Liquid chromatography-mass spectroscopy (LC-MS), X-ray photoelectron spectroscopy (XPS), and Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analyses revealed degradation of protochelin and adsorptions of its byproducts on molybdenite surface to promote dissolution. Conversely, DFOB inhibited molybdenite dissolution under both oxic and anoxic conditions, likely attributed to surface adsorption of DFOB and its weak complexation with Mo(VI) at the circumneutral pH. This work highlights the need to consider the balance between promoting and inhibitory effects of different metallophores on Mo-mineral dissolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Zwitterionic Chromatography Approach to Separate Lithium from Unconventional Resources

Lithium (Li) is a key element for clean energy technologies, and, accordingly, the global lithium demand has been increasing rapidly. Therefore, to meet the Li demand and maintain supply chain stability, it is critical to develop efficient lithium extraction technologies that allow exploitation of unconventional lithium resources, such as geothermal brines and inland brine streams. However, the recovery of Li from these resources is challenging due to low Li concentration, low ratios of Li/Na, Li/Mg, or Li/Ca, and complex feed compositions. To address this, we introduced a new Direct Lithium Extraction (DLE) process using Zwitterionic Chromatography (ZIC) to separate Li from other salts. Since salts are partitioned on ZIC under water elution, no reagent chemicals are needed, and the Li separation is not limited by the adsorption capacity. We prepared 13 different zwitterionic (ZI) resins to investigate the salt retention on various ZI groups and then screened out promising sorbents for efficient Li separation. It was found that salt retention was synergistically affected by the pore size and ZI configurations. Using carboxybetaine (QAC3CA) sorbents, multicomponent separations showed that Li can be partitioned from divalent salts or Na with selectivities of 1.8 or 1.9, respectively. Although the selectivity is relatively low, in real brine tests, Li was separated from Ca and Mg with 79.2 % yield, showing the potential for a continuous process to achieve high productivity and high yield. Simulation studies suggest the salt elution mechanism is related to the hydration reaction energy and the effective hydrated radius of cations.

critical minerals↗

Simultaneous concentration and purification through gradient deformation chromatography

Mobile-phase additives, commonly used to modulate absorbate retention in gradient elution chromatography, are usually assumed to be either linearly retained or unretained. Previous theoretical work from our laboratory has shown that these modulators, such as salts in ion-exchange and hydrophobic interaction chromatography and organic modifiers in reversed-phase chromatography, can absorb nonlinearly, giving rise to gradient deformation. Consequently, adsorbate peaks that elute in the vicinity of the head of the deformed gradient may exhibit unusual shapes, form shoulders, and/or be concentrated. These effects for a reversed-phase sorbent with aqueous acetonitrile (ACN) as the modulator are verified experimentally. Gradient deformation is demonstrated experimentally and agrees with simulations based on ACN isotherm parameters that are independently determined from batch equilibrium studies using the layer model. Unusual absorbate peak shapes were found experimentally for single-component injections of phenylalanine, similar to those calculated by the simulations. A binary mixture of tryptophan and phenylalanine is used to demonstrate simultaneous concentration and separation, again in agreement with simulations. The possibility of gradient deformation in ion-exchange and hydrophobic interaction chromatography is discussed.

NASA Discipline Number 93-10↗

Concentrating Gaseous Contaminants For Monitoring

Apparatus concentrates contaminants outgassing from specimens in vacuum and passes concentrated contaminants to gas-chromatography/mass-spectrometry system for analysis. Cold wall of collection chamber adsorbs gases from specimen in isothermal cell. When wall heated, plate desorbs gases so they can be analyzed. Collection chamber maintained at low pressure throughout adsorption and desorption process. Determines whether candidate materials for use in vacuum environments generate harmful substances.

Mahone, William C.↗

Polymerization on the rocks: negatively-charged alpha-amino acids

Oligomers of the negatively-charged amino acids, glutamic acid, aspartic acid, and O-phospho-L-serine are adsorbed by hydroxylapatite and illite with affinities that increase with oligomer length. In the case of oligo-glutamic acids adsorbed on hydroxylapatite, addition of an extra residue results in an approximately four-fold increase in the strength of adsorption. Oligomers much longer than the 7-mer are retained tenaciously by the mineral. Repeated incubation of short oligo-glutamic acids adsorbed on hydroxylapatite or illite with activated monomer leads to the accumulation of oligomers at least 45 units long. The corresponding reactions of aspartic acid and O-phospho-L-serine on hydroxylapatite are less effective in generating long oligomers, while illite fails to accumulate substantial amounts of long oligomers of aspartic acid or of O-phospho-L-serine.

NASA Discipline Exobiology↗

Carrier-assisted One-pot Sample Preparation for Targeted Proteomics Analysis of Small Numbers of Human Cells

Protein analysis of small numbers of human cells is primarily achieved by targeted proteomics with antibody-based immunoassays, which have inherent limitations (e.g., low multiplex and unavailability of antibodies for new proteins). Mass spectrometry (MS)-based targeted proteomics has emerged as an alternative because it is antibody-free, high multiplex, and has high specificity and quantitation accuracy. Recent advances in MS instrumentation make MS-based targeted proteomics possible for multiplexed quantification of highly abundant proteins in single cells. However, there is a technical challenge for effective processing of single cells with minimal sample loss for MS analysis. To address this issue, we have recently developed a convenient protein carrier-assisted one-pot sample preparation coupled with liquid chromatography (LC) - selected reaction monitoring (SRM) termed cLC-SRM for targeted proteomics analysis of small numbers of human cells. This method capitalizes on using the combined excessive exogenous protein as a carrier and low-volume one-pot processing to greatly reduce surface adsorption losses as well as high-specificity LC-SRM to effectively address the increased dynamic concentration range due to the addition of exogeneous carrier protein. Its utility has been demonstrated by accurate quantification of most moderately abundant proteins in small numbers of cells (e.g., 10-100 cells) and highly abundant proteins in single cells. The easy-to-implement features and no need for specific devices make this method readily accessible to most proteomics laboratories. In this study, we have provided a detailed protocol for cLC-SRM analysis of small numbers of human cells including cell sorting, cell lysis and digestion, LC-SRM analysis, and data analysis. Further improvements in detection sensitivity and sample throughput are needed towards targeted single-cell proteomics analysis. We anticipate that cLC-SRM will be broadly applied to biomedical research and systems biology with the potential of facilitating precision medicine.

60 APPLIED LIFE SCIENCES↗

Tailoring the Selective Oxidation of Hydroxyl-Containing Compounds via Precisely Tuning the Hydrogen-Bond Strength of Catalyst H-Bond Acceptors

The unique performance of the enzyme is mainly achieved via weak interactions between the “outer coordination sphere” and the substrate. Inspired by this process, we developed 3D encapsulated-structure catalysts with hydrogen-bond engineering on the shell, which mimics the “outer coordination sphere” of an enzyme. Various hydrogen bond acceptors (C=O, S=O, and N–O groups) are imparted in the shell. Concentration-dependent 1H NMR, inverse-phase gas Chromatography (IGC) measurements, and DFT calculations underscore that the hydrogen bond strength between the acceptor groups and alcohol follows the order of C=O < S=O < N–O. The hydroxyl compound oxidation rate vs the hydrogen bond strength follows a volcano behavior, reminiscent of Sabatier’s principle. The performance variation among catalysts is attributed to the adsorption strength of the substrate. The proposed bioinspired design principle expands the scope of encapsulated catalysts, enabling fine regulation of catalytic activity through precise microenvironment control via weak interactions with substrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crosslinked polymeric ionic liquid stationary phases incorporating a combination of silver(I) and copper(II) ions for olefin separations by gas chromatography

The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acetylated Lysozyme as Impurity in Lysozyme Crystals: Constant Distribution Coefficient

Hen egg white lysozyme (HEWL) was acetylated to modify molecular charge keeping the molecular size and weight nearly constant. Two derivatives, A and B, more and less acetylated, respectively, were obtained, separated, purified and added to the solution from which crystals of tetragonal HEWL crystals were grown. Amounts of the A or B impurities added were 0.76, 0.38 and 0.1 milligram per millimeter while HEWL concentration were 20, 30 and 40 milligram per milliliter. The crystals grown in 18 experiments for each impurity were dissolved and quantities of A or B additives in these crystals were analyzed by cation exchange high performance liquid chromatography. All the data for each set of 18 samples with the different impurity and regular HEWL concentrations is well described by one distribution coefficient K = 2.15 plus or minus 0.13 for A and K = 3.42 plus or minus 0.25 for B. The observed independence of the distribution coefficient on both the impurity concentration and supersaturation is explained by the dilution model described in this paper. It shows that impurity adsorption and incorporation rate is proportional to the impurity concentration and that the growth rate is proportional to the crystallizing protein in solution. With the kinetic coefficient for crystallization, beta = 5.10(exp -7) centimeters per second, the frequency at which an impurity molecule near the growing interface irreversibly joins a molecular site on the crystal was found to be 3 1 per second, much higher than the average frequency for crystal molecules. For best quality protein crystals it is better to have low microheterogeneous protein impurity concentration and high supers aturation.

Thomas, B. R.↗

Improved Thermal Modulator for Gas Chromatography

An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

Hasselbrink, Ernest Frederick, Jr.↗

Fluoroarene Separations in Metal-Organic Frameworks with Two Proximal Mg 2+ Coordination Sites

Fluoroarenes which are widely used in medicinal, agricultural, and materials chemistry, and yet their production remains a critical challenge in organic synthesis. Indeed, the nearly identical physical properties of these vital building blocks hinders their purification by traditional methods, such as flash chromatography or distillation. As a result, the Balz-Schiemann reaction is currently employed to prepare fluoroarenes instead of more atom-economical C-H fluorination reactions, which produce inseparable mixtures of regioisomers. Herein, we propose an alternative solution to this problem: the purification of mixtures of fluoroarenes using metal-organic frameworks (MOFs). Specifically, we demonstrate that controlling the interaction of fluoroarenes with adjacent coordinatively unsaturated Mg 2+ centers within a MOF enables the separation of fluoroarene mixtures with unparalleled selectivities. Liquid-phase multicomponent equilibrium adsorption data and breakthrough measurements coupled with van der Waals-corrected density functional theory calculations reveal that the materials Mg 2 (dobdc) (dobdc 4- = 2,5-dioxidobenzene-1,4-dicarboxylate) and Mg 2 ( m -dobdc) ( m -dobdc 4- = 2,4-dioxidobenzene-1,5-dicarboxylate) are capable of separating the difluorobenzene isomers from one another. Additionally, these frameworks facilitate the separations of fluoroanisoles, fluorotoluenes, and fluorochlorobenzenes. In addition to enabling currently unfeasible separations for the production of fluoroarenes, our results suggest that carefully controlling the interaction of isomers with not one but two strong binding sites within a MOF provides a general strategy for achieving challenging liquid-phase separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction chromatography of 225 Ac and lanthanides on N,N-dioctyldiglycolamic acid /1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide solvent impregnated resin

The alpha-emitter 225 Ac (t 1/2 = 9.92 d) is currently under development for targeted alpha-particle therapy of cancer, and accelerator production of 225 Ac via proton irradiation of thorium targets requires robust separations of 225 Ac from chemically similar fission product lanthanides. Additionally, the lanthanide elements represent critical components in modern technologies, and radiolanthanides such as 140 Nd (t 1/2 = 3.37 d) also have potential application in the field of nuclear medicine. The ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([Bmim][NTf 2 ]), combined with the diglycolamide extractant, N,N-dioctyldiglycolamic acid (DODGAA), was adsorbed on macroporous resin support to produce a solvent impregnated resin (SIR) that was investigated for separations of 225 Ac and lanthanides. The equilibrium distribution coefficients (Kd) of the rare earth elements (Sc(III), Y(III), Ln(III)), 225 Ac(III), Th(IV), and U(VI) on the prepared DODGAA/[Bmim][NTf 2 ]-SIR were determined from batch adsorption experiments in HCl and HNO 3 media. The DODGAA/[Bmim][NTf2]-SIR exhibited preferential uptake of the heavier lanthanide elements while allowing for the separation of the lighter lanthanides. Column separations utilizing the DODGAA/[Bmim][NTf 2 ]-SIR were effective at separating the lighter lanthanides from each other, and separating 225 Ac from a mixture of lanthanides, 213 Bi, and 225 Ra without the need for additional complexing agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Xplo-SA9T: Optimization of Sorbent Technology With Existing and New Amine Variants for Carbon Dioxide Removal and Humidity Control

Scrubbing of the spacesuit air stream to control humidity and regulate carbon dioxide (CO 2 ) relies on amine-loaded resins, colloquially known as sorbents. The efficacy of Rapid Cycle Amine technology relies on the propensity of nitrogens toward adsorption of CO 2 while simultaneously offering regenerative properties under vacuum or positive pressure. The commonly utilized sorbent, SA9T, was recreated and evaluated further to increase stability and serve as a benchmark comparison for newly synthesized amine sorbent technologies. Ongoing storage studies with eight different environments will allow the development of applicable storage protocols and provide insight into possible ammonia generation pathways. Attempts to alleviate the known issues with SA9T included the alteration of the primary amine (tetraethylenepentamine), the choice of resin, and the particle size distribution. In-house CO 2 breakthrough experiments were conducted using a specialized apparatus that can simulate spacesuit conditions, offering high-quality triplicate capacity analysis affording direct comparison to known adsorbents in the literature. Thermo-Desorption Gas Chromatography Mass Spectrometry studies on the synthesized materials revealed any reagent or solvent offgassing while Nuclear Magnetic Resonance spectroscopy tracked the stability of the bound amine. Scanning Electron Microscope images of sieved materials provided a more accurate size interpretation facilitating synthetic design and pressure drop elimination. All efficient sorbents were synthesized to a commercial batch scale subsequent to evaluation including Xplo-SA9T.

John R Tidwell↗

A Tip-based Workflow for Sensitive IMAC-based Low Nanogram Level Phosphoproteomics

Analyzing the phosphoproteome at nanoscale poses a significant challenge, mainly due to the substantial sample loss from non-specific surface adsorption during the enrichment of low stoichiometric phosphopeptides. Here, we describe a tandem tip-based phosphoproteomics sample preparation method capable of sequential sample cleanup and enrichment without the need for additional sample transfer, thereby minimizing sample loss. Integration of this method to our recently developed SOP (Surfactant-assisted One-Pot sample preparation) and iBASIL (improved Boosting to Amplify Signal with Isobaric Labeling) approaches creates a streamlined workflow, enabling sensitive, high-throughput nanoscale phosphoproteomics measurements.

Phosphoproteome, Immobilized metal ion affinity ch↗

Collaborative Research: Natural Organic Matter and Microbial Controls on Mobilization/Immobilization of I and Pu in Soils and Waters Affected by Radionuclide Releases in USA and Japan

In this project, the relationship between natural organic matter (NOM) and two radioactive elements that are relevant to nuclear waste disposal were studied: Plutonium (Pu) and Iodine. The human and environmental risks associated with Pu stem mainly from the very long half-lives of several of its isotopes ( 238 Pu, 88 yr; 239 Pu, 24,100 yr; 240 Pu, 6560 yr) and its radiotoxicity. Understanding Pu biogeochemical behavior in both near-field (>10-11M) and far-field scales (<10-11M) is imperative to the development of approaches for reprocessing Pu, remediation of Pu contamination and accurate assessment of risks posed by disposal practices for Pu-bearing wastes. The environmental mobility of Pu can be affected by redox potential, pH, adsorption, precipitation, complexation, colloid formation, and microbial activity, of which the first characteristic has the most profound influence. Numerous studies have shown high affinity of Pu towards NOM, as well as to mineral phases. NOM is ubiquitous in the environment, e.g., both fulvic and humic acids are able to reduce Pu(V,VI) to Pu(IV) and the redox potential of NOM is positively related to the abundance of phenolic/acidic OH groups. NOM can either facilitate or limit actinide migration, depending on specific biogeochemical conditions including pH, mineral and organic matter characteristics, etc. The other radionuclide of interest is radioiodine ( 129 I). 129I is a major by-product of nuclear fission and of serious concern to the Department of Energy (DOE) as it is among the top risk drivers at existing and potential radiowaste-contaminated sites. The risk of 129 I stems largely from its high bioconcentration factor (90% of the body’s iodine is accumulated in the thyroid), a high inventory at source terms, a very long-half life (16M years), and rapid mobility in the subsurface environment. As a consequence, 129 I has the lowest drinking water standard (1 pCi/L) among all radionuclides in the Federal Register. With a novel and sensitive gas chromatography-mass spectrometry (GC-MS) method developed in our lab, it is possible to quickly and simultaneously determine the distribution of 129 I and stable 127 I forms in environments, as low as 2 pCi/L for 129 I. This method was subsequently validated using accelerator mass spectroscopy, AMS. IO 3 - and organo-I were determined as major species in the groundwater of SRS and the Hanford Site, contrary to thermodynamic predictions that I- should be the dominant species at these sites. Mobility of 129 I was also demonstrated to depend greatly on the I species and its concentration, sediment pH, and redox state, with times to achieve equilibrium taking up to 12 weeks. Along the groundwater pathway in the F-Area of SRS, 129 I- supplied from the seepage basins was transformed to 129 IO 3 - and organo- 129 I with increasing iodine sediment sorption, causing the lower total 127 I and 129 I concentrations along the gradient transect of the waste plume. By contrast, groundwater 129 I concentrations in the wetlands (as high as 1617.3 pCi/L) were greatly elevated with respect to the source term (159.3 pCi/L). While the NOM promoted the uptake of 129 I to the wetland sediment, it also promoted the formation of soluble organic fraction. A small fraction of NOM that is bound to iodine can behave as a mobile organo-I source. Iodide was enzymatically incorporated into NOM, whereas both iodide and iodate were abiotically bound to NOM, under certain conditions. Iodate removal from the mobile aqueous phase can also occur through incorporation into carbonate (e.g., at the Hanford Site, USA). Thus immobilization and re-mobilization of iodine species were influenced by pH, Eh and the presence of NOM and metal oxides, which adds to the complexity of site remediation action. A ground-breaking result was to elucidate the products (i.e. organo-iodine moieties formed via enzymatic and non-enzymatic processes) at the molecular level by nuclear magnetic resonance (NMR) and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). We found that iodine-NOM interactions may be influenced by NOM hydrophobic aliphatic moieties. From the perspective of ESI-FTICRMS, organo-iodine formulas were ascribed to the groups of unsaturated hydrocarbons, lignins and proteins. Iodate is likely abiotically reduced to reactive iodine species by lignin- and tannin-like compounds or carboxylic-rich alicyclic molecules (CRAM). We also investigated microbial mechanisms in iodine incorporation into NOM. We established that soil bacteria isolated from F-Area of SRS did not accumulate significant amounts of I- (0.2-2%). Intracellular uptake of I- decreases with increasing pH when pH ranged from 4 to 6. In contrast, 44 out of 84 strains isolated from the F-Area of SRS can transform I- to IO 3 - and organo-iodine. In some cases, oxidation was facilitated in the presence of H 2 O 2 . Microbes can also excrete organic acids that enhance I- oxidation by lowering the ambient pH and reacting with H 2 O 2 to form peroxy carboxylic acids. At lower pH values (≤5), H 2 O 2 hydrolysis was the driving force for iodide-oxidation; whereas, at pH ≥ 6, spontaneous decomposition of peroxy carboxylic acids, originating from H 2 O 2 and organic acids were the primary cause of iodide oxidation. Lastly, it was determined that microbial processes involved in Mn (II) are capable of directly oxidizing I- via enzymatic catalysis (i.e., multicopper oxidases), or indirectly through the formation of reactive oxygen species (ROS) and/or biogenic manganese oxides. ROS-mediated oxidation of I- was found to predominate at pH >5, whereas the enzymatic and Mn oxide pathways were more active at pH < 5. Together, this project has resulted in 9 publications in high-impact journals, and the training of 1 Ph.D and 4 undergraduate students.

54 ENVIRONMENTAL SCIENCES↗

Multisorbent tubes for collecting volatile organic compounds in spacecraft air

The sampling capability of Tenax-TA tubes, used in the National Aeronautics and Space Administration's solid sorbent air sampler to trap and concentrate contaminants from air aboard spacecraft, was improved by incorporating two sorbents within the tubes. Existing tubes containing only Tenax-TA allowed highly volatile compounds to "break through" during collection of a 1.5 L air sample. First the carbon molecular sieve-type sorbents Carboxen 569 and Carbosieve S-III were tested for their ability to quantitatively trap the highly volatile compounds. Breakthrough volumes were determined with the direct method, whereby low ppm levels of methanol or Freon 12 in nitrogen were flowed through the sorbent tubes at 30 mL/min, and breakthrough was detected by gas chromatography. Breakthrough volumes for methanol were about 9 L/g on Carboxen 569 and 11 L/g on Carbosieve S-III; breakthrough volumes for Freon 12 were about 7 L/g on Carboxen 569 and > 26 L/g on Carbosieve S-III. Next, dual-bed tubes containing either Tenax-TA/Carbosieve S-III, Tenax-TA/Carboxen 569, or Carbotrap/Carboxen 569 to a 10-component gas mixture were exposed, in dry and in humidified air (50% relative humidity), and percentage recoveries of each compound were determined. The Tenax-TA/Carboxen 569 combination gave the best overall recoveries (75-114% for the 10 compounds). Acetaldehyde had the lowest recovery (75%) of the 10 compounds, but this value was still an improvement over either the other two sorbent combinations or the original single-sorbent tubes.