Search NASASearch

SEARCH · Search NASA

Results for “aerothermal flight instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

422 records · Page 3

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Landsat Instrument Suite (LandIS) Sensor Design for the Landsat 10 Mission

Landsat 10 will be the upcoming mission in the 50+ year Landsat series of Earth observation platforms. The centerpiece of the observatory will be a super-spectral imager known as the Landsat Instrument Suite (LandIS). The sensor will feature 26 spectral channels from the visible through near-, short-wave, and thermal infrared wavelengths with spatial resolutions of 10, 20, and 60 meters on the ground, depending on the band. These enhancements over the legacy Landsat instruments will ensure data continuity with the existing archive and will expand upon the core Landsat capabilities to enable new applications in Earth science. After a competitive procurement, NASA selected the design submitted by the Raytheon Company for the LandIS instrument. The innovative Raytheon instrument concept utilizes an advanced whiskbroom architecture to fulfill the strict radiometric, spatial, and geometric image quality requirements demanded by the Landsat 10 mission and fits within restrictive mass, volume, and power constraints. The instrument will continue the Landsat directive to image all daylit land and near-shore water areas, along with select nighttime imaging. On-board calibration source data will ensure high radiometric and geometric accuracy and stability consistent with previous missions to enable continuity in data products available to users. This paper discusses the driving requirements for LandIS and provides a description of the chosen design and operations concept of the instrument.

Requirements

Space Telescope Optical Telescope Assembly/Scientific Instruments: Phase B - Preliminary Design and Program Definition Study: Volume 2A - Planetary Camera

Development of the F/48, F/96 Planetary Camera for the Large Space Telescope is discussed. Instrument characteristics, optical design, and CCD camera submodule thermal design are considered along with structural subsystem and thermal control subsystem. Weight, electrical subsystem, and support equipment requirements are also included.

Itek Optical Systems

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

The Deep Space Network: A Radio Communications Instrument for Deep Space Exploration

The primary purpose of the Deep Space Network (DSN) is to serve as a communications instrument for deep space exploration, providing communications between the spacecraft and the ground facilities. The uplink communications channel provides instructions or commands to the spacecraft. The downlink communications channel provides command verification and spacecraft engineering and science instrument payload data.

N A Renzetti

Design, Build, and Testing of the Roman Space Telescope’s Wide Field Instrument Optical Stimulus System (SORC)

The Stimulus Of Ray Cones (SORC) is an optical stimulus system developed to verify, characterize, and calibrate the Roman Space Telescope’s (RST) Wide Field Instrument (WFI) under simulated operational conditions. SORC provides several critical test modes, the primary being point-source mode, which projects an image anywhere on the Focal Plane Assembly (FPA) detectors. This mode provides precise position knowledge of the FPA within WFI. Additional modes enable capturing WFI pupil alignment, evaluation of WFI’s selectable optical elements, and verification of focal plane fiber operation for higher-level system testing. The light source system incorporates a suite of narrowband and broadband fiber fed sources spanning the visible to near-infrared range, with options for pulsed or continuous wave illumination. SORC was designed and built at NASA’s Goddard Spaceflight Center (GSFC). Initial system-level testing occurred under ambient conditions in GSFC’s Spacecraft Systems Development and Integration Facility (SSDIF), followed by vacuum testing at operational temperatures (SORC at 214-222 K) in the Space Environment Simulator (SES). The system was then shipped to BAE Systems in Boulder, CO for post-shipment ambient and cryogenic testing before integration with WFI for two thermal vacuum test campaigns at cryogenic temperatures. This presentation will focus on design, development, and performance of SORC. Details of WFI verification and calibration using SORC, along with test results, have been published previously and will be referenced only as needed to describe SORC. The SORC ground test capability is critical to ensuring WFI meets stringent optical performance requirements, directly supporting the mission’s science objectives.

Stimulus of Ray Cones

P-band Antenna Array for NASA's Space Exploration Synthetic Aperture Radar (SESAR) Instrument

A dual-polarized, wideband, lightweight P-band (435 MHz) antenna element and array for spaceborne radar applications has been developed for NASA’s SESAR (Space Exploration Synthetic Aperture Radar) instrument for planetary synthetic aperture radar (SAR) applications. The antenna array is based on lightweight, low-profile antenna elements that form the building blocks of configurable “array panels” that can in turn be used to build larger arrays consisting of multiple panels. The element design combines a novel, mostly planar conductor antenna element geometry with a robust lightweight composite material construction.

Synthetic Aperture Radar

Methods for Validation of Random Uncertainty Estimates and Their Applications to Ozone Profiles From Limb-Viewing Satellite Instruments

For satellite measurements of atmospheric composition, the random uncertainty estimates provided by retrieval algorithms might be imperfect due to various approximations used in the retrievals or the presence of unknown error sources. This paper presents an overview of the methods used for the validation of random uncertainty estimates. All methods discussed in this study are categorized, and assumptions and limitations of each method are discussed. This overview evaluates these methods in application to ozone profile measurements from limb and occultation satellite instruments and provides practical illustrations of random uncertainty validation.

Viktoria F Sofieva

A Design Solution to the Spacecraft Look-Angle Problem

As the state of the art of the design of spacecraft has progressed, one of the difficult problems which has arisen is the positioning and articulating of spacecraft elements which must “see” in different directions without interference. Some of these elements are: solar panels or collectors, Sun sensors, communication antennas, star seekers, planet tracking and scanning devices, rocket motors, attitude-control jets, and scientific instruments. This Report presents a method of testing a spacecraft design to determine how well it satisfies these look-angle requirements. This method is applied to both simple and complex cases, and examples of its use are presented. A means of assessing spacecraft constraints on trajectories is discussed. The method was developed for the Mariner interplanetary spacecraft, but should be applicable to other cases.

MARINER PROGRAM

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars

Characterization of Quicksounder ATMS at Instrument Level TVAC

QuickSounder (QS) is the pathfinder space mission for the next generation of NOAA LEO environmental satellites in the NEON program, follow-on to the JPSS program. It is a collaborative initiative between NASA and NOAA to verify rapid and cost-effective delivery of small Earth observation satellites. QuickSounder is focusing on mission elements other than science performance. In this context, an existing sensor, the refurbished ATMS EDU (Advanced Technology Microwave Sounder, Engineering Development Unit) was chosen as the QuickSounder payload. This poster discusses the performances of QuickSounder ATMS during thermal vacuum (TVAC) calibration to ensure that QS ATMS is characterized and calibrated in the same manner as JPSS ATMS units, even though science performance attributes are not the priority of this mission.

Saji Abraham

Developing a Pyrolysis Gas Thermal Blocking Model for Reentry Demise

In NASA’s Object Reentry Survival Analysis Tool (ORSAT), aerodynamic drag and aerothermal heating coefficients are computed for each of the free-molecular, continuum, and transitional flow regimes using analytical and semi-analytical methods. These heating coefficients were derived for typical metallic materials that melt and do not have a strong gas-phase contribution to the flow in the boundary layer. Modern satellites typically feature fiber-reinforced polymer (FRP) components, such as solar array booms, facesheets of sandwich panels, or overwraps for composite-overwrapped pressure vessels (COPV). These FRP materials do not behave the same as metals in the reentry environment, but instead will pyrolyze and develop significant volumes of gas into the boundary layer. Accurately predicting the reentry demise of FRP components is critical to assessing the reentry casualty risk for modern spacecraft. Research in recent years has shown that this demisability can depend heavily on how the expulsion of gaseous pyrolysis products through the outer surface of the material affects the heat flux at the surface. The ODPO has been developing a reduced-order model of the effect of pyrolysis gas blowing on the heat flux based on correlations between a blowing factor and a non-dimensional heat flux to be incorporated in the upcoming version 7.3 of the Object Reentry Survivability Analysis Tool (ORSAT). This presentation discusses the progress of this development project and the challenges remaining for generalizing the model across families of FRP materials.

Benton Greene

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer

Following the αCen Ab Candidate Using the Roman Coronagraph Instrument

The Roman Space Telescope Coronagraph offers a unique opportunity to observe our nearest solar twin, Alpha Centauri A, and characterize the habitable-zone gas giant candidate, Alpha Cen Ab. The candidate uniquely stands out among all imaged exoplanets to date as the one most similar in temperature, age and location to the planets in our own Solar System. Roman CGI offers the tantalizing opportunity to observe the candidate—determining its radius, temperature, and albedo—and to constrain its orbit. Observing Alpha Cen Ab with Roman would make it the first exoplanet to be imaged in both thermal emission and reflected light and would motivate an exciting search for habitable exomoons with the upcoming ELTs and HWO. In addition, this candidate will inform the planet formation history and current dynamics of the Alpha Centauri AB system, including potentially habitable planets around both stars. In this talk, we describe our plan to observe this target using the Roman CGI, including the timing strategy to minimize contrast and avoid background objects. We also describe the key technical insights about coronagraph performance that we aim to gain, such as measuring companion leakage intensity, evaluating the impact of the large stellar diameter, and assessing CGI performance on very bright targets. In subsequent observations, we aim to demonstrate Multi-Star Wavefront Control (MSWC) on-sky, observing Alpha Cen A using the Wide FoV Shaped Pupil MSWC contributed mode in the Roman CGI. The insights from these technology demonstrations are crucial preparation for the planned HWO mission.

Coronagraph

Radio Metric Errors Due to Mismatch and Offset Between a DSN Antenna Beam and the Beam of a Troposphere Calibration Instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10 -14 with a 4-deg beam and 1.3 x 10 -15 for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10 -14 over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield

QS ATMS Calibration Data Book Government Version: Pre-Launch Version

The Advanced Technology Microwave Sounder (ATMS) SN301 is an instrument onboard the QuickSounder Satellite System, QuickSounder mission (renamed QS). Throughout this document the mission may be referred to as QuickSounder or QS. The purpose of this document is to provide information needed to interpret and process QS ATMS science data. The contents of the data book incorporate results from pre-launch subsystem-level and instrument-level testing as well as post-launch testing performed during instrument commissioning. Major milestones include instrument thermal vacuum (TVAC) testing in May 2024 and observatory TVAC testing in 2026. QS launch will be no earlier than Feb. 15, 2027.

Microwave Radiometer

3D Woven Mid-Density Carbon Phenolic (3MDCP) Full-Scale Heatshield Development for Mars Sample Return (MSR) Earth Entry System (EES)

The Mars Sample Return (MSR) mission will be returning samples of Martian soil to Earth. The samples will be returned in the Earth Entry System (EES). The EES capsule is protected by a new thermal protection system; the 3-Dimensionally Woven, Mid-Density, Carbon Phenolic (3MDCP) material which is derived from the Heatshield for Extreme Entry Environment Technology (HEEET). The baseline 3MDCP design is a single piece thermal protection system that avoids the manufacturing and certification challenges associated with a tiled configuration. A 3MDCP heatshield begins as a flat woven preform that is formed to the final heatshield shape and then infused with phenolic resin. A NASA Ames lead team, in collaboration with Spirit Textiles (formerly TEAM Inc.), Fiber Materials Inc. (FMI, a Spirit AeroSystems Company), and Kratos SRE, has been developing and demonstrating the processes to fabricate the 3MDCP heatshield and characterize the resulting properties. The process of forming the flat woven preform into the final heatshield shape, a sphere-cone geometry with a 52.5° cone angle, involves local but substantial movement of the yarns in the weave. This results in continuous fibers across the single piece heatshield, albeit with property variations between different regions of the heatshield. This presentation will provide a high-level status of 3MDCP development for the MSR EES heatshield. This will include an overview of the manufacturing processes with an emphasis on the impact of forming on fiber orientation, material properties, and performance. Results comparing preliminary formed and flat materials will be shown. Additionally, the presentation will layout the broader plan for property testing and tie-in to aerothermal performance.

Peter Edward Marshall