Search NASA⌕ Search

SEARCH · Search NASA

Results for “air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Evaluation of short-term initial performance of a “Molekule Air” portable air cleaner

The aim of this project was to evaluate and characterize the performance of a MOLEKULE AIR air cleaner unit. The testing protocol comprised the evaluation of an unused Molekule Air unit operating at maximum (“boost” setting) fan speed setting. The device was tested over initial short-term periods of 70-80 h of continuous operation. The tested air cleaner was challenged in separate experiments with a well-characterized mixture of volatile organic compounds (VOCs), and with ozone. All tests were performed at realistic pollutant levels in a 20-m 3 environmental stainless-steel chamber. Variables controlled and measured in this study included the chamber temperature, relative humidity, the composition and concentration of the challenge VOCs, and the concentrations of ozone. Potential formation of byproducts was also investigated to assess the overall performance.

47 OTHER INSTRUMENTATION↗

Bayesian modeling of traffic-related air pollutants: A case study of urban transportation and air quality dynamics in Columbia, South Carolina

Traffic emissions significantly impact near-road air quality and public health. This research applies a Bayesian modeling framework to investigate these impacts using high-resolution traffic and air pollutant data from an urban corridor in Columbia, South Carolina. Despite a data collection period truncated by the COVID-19 lockdown, the Bayesian approach successfully identified significant predictors and quantified model uncertainty. Employing Bayesian Model Selection and Averaging enhanced prediction accuracy and evaluated model uncertainty. Findings indicate that higher temperatures and increased moisture levels elevate particulate matter (PM 1.0 , PM 2.5 , PM 10 ) concentrations, while traffic speed significantly affects nitrogen dioxide (NO 2 ) levels. Specifically, higher average traffic speeds (indicative of smoother flow) correspond to lower NO 2 concentrations, suggesting that less congested conditions reduce NO 2 emissions. This study highlights the robustness of Bayesian methods for generating reliable air quality insights even under data-constrained conditions. The findings underscore the importance of traffic flow management (e.g., reducing congestion) for mitigating near-road NO 2 exposure and provide a basis for developing targeted public health strategies.

54 ENVIRONMENTAL SCIENCES↗

Machine learning based simultaneous control of air handling unit discharge air and condenser water temperatures set-point for minimized cooling energy in an office building

In this study, an artificial intelligence based real-time prediction and control model to optimize condenser water temperature and discharge air temperature (DAT) set-points in water-cooled air handling unit (AHU) system has been developed. EnergyPlus-MATLAB co-simulation has been conducted to analyze the developed model's effectiveness. Here, to develop artificial neural networks (ANN) model, embedded neural network objects in MATLAB was utilized. The developed model could decide an optimal temperature set-points based on outdoor air wet-bulb temperature to reflect the Korean climate context. As a result, the developed ANN prediction model showed the predictive performance of Cv(RMSE) of approximately 21%. Compared to the conventional fixed temperature algorithm, which fixes AHU DAT at 14°C and condenser water temperature at 32°C, the ANN based optimized control showed a 22% total cooling energy reduction. These results show that significant energy savings can be achieved by simultaneously controlling condenser water temperature and AHU DAT set-points considering Korean climatic characteristics using AI technologies such as ANN models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficiency of Room Air Cleaners for Removal of Bioaerosols From Ambient Air

The COVID-19 pandemic necessitated the evaluation of commercial air purification units to protect worker safety in indoor spaces. This project evaluated the efficacy of commercial off-the-shelf air purification systems that utilize electrostatic precipitation for the collection and removal of particulates (including bioaerosols) from ambient air. An aerosol mist containing Escherichia coli (E. coli) and bacteriophage surrogate virus, MS2, was produced using a nebulizer and delivered to the front intake of the commercial system with the ionizer ON and OFF. Removal efficiency was evaluated by colony/plaque formation assays using a small agar plate (60 X 15 mm) to passively collect E. coli and MS2 exhausting from the electrostatic precipitation cell. The system was determined to remove 98-99% of the microorganism introduced to the system. Testing was performed with all pre- and post-electrostatic cell filters removed so further removal is anticipated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing of Portable Air Cleaner Products for Energy Efficiency and Clean Air Performance at Various Fan Settings [Slides]

This document contains the results of a product review and laboratory testing experiment of portable air cleaning devices (PACs). Thirty-four commercially available PACs were reviewed, and from those, 7 products were purchased and underwent AHAM AC-7 clean air delivery rate (CADR) testing. The following research questions were explored: 1) What is the relationship between clean air delivery rate (CADR) and energy across a range of products and what is the general decrement in CADR as a result of operating at lower fan speeds? 2) How might the multiple units at lower power compare to fewer, larger units at full power in terms of energy efficiency and total cost? 3) How do the measured CADR, power, and efficiency compare to the manufacturer specs? 4) Are there product attributes that can be identified that might contribute to better CADR/W performance?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disparities in the air quality monitoring stations and PM₂.₅ in Chicago’s air quality landscape

Fine particulate matter (PM₂.₅) poses significant public and environmental health risks in urban areas. Chicago’s dense industry and traffic create variable air quality, yet monitoring is unevenly distributed, resulting in undersampling of air quality data in some city areas. This study applied a hybrid approach using GIS-based kernel density mapping, interpolation modeling (IDW, Spline, Kriging) of USEPA monitoring data, multi-scale temporal trend analyses (hourly to annual), and ESDA. Accordingly, the density surface showed that monitors are concentrated in the affluent north, northwest, and southwest sides of Chicago (up to ~ 0.07 stations per sq mile), while the south and southeast regions, with predominantly minority communities, have virtually no coverage. Overall, citywide coverage is minimal (~ 4–5 monitors total; ~0.02 per sq mile; ≈1 per 600,000 residents). Temporal analyses showed that the city’s mean annual PM₂.₅ (~ 10.8 µg/m³) exceeds USEPA/WHO standards (9 µg/m³), with summer means (~ 17.1 µg/m³) significantly higher than other seasons. Diurnally, a clear pattern was observed, with PM₂.₅ concentrations peaking overnight (00:00–03:00) and during the morning rush hours, and dipping during midday to late afternoon. Spatial distribution of PM₂.₅ identified hotspots near O’Hare Airport, the downtown Loop area, and south-side neighborhoods, contrasting with lower concentrations on the north side, revealing Chicago’s socioeconomic divides and resulting environmental inequities. The findings underscore the need for expanded monitoring and targeted interventions in under-monitored, high-pollution communities to advance equitable community health.

54 ENVIRONMENTAL SCIENCES↗

Enriched hydrogen production over air and air-steam fluidized bed gasification in a bubbling fluidized bed reactor with CaO: Effects of biomass and bed material catalyst

Gasification is one of the methods of generating biopower or biofuels from biomass waste. In this study, a benchscale fluidized bed reactor was used for biomass air and air-steam gasification. Gasification was performed under constant operating conditions (~780 °C, equivalence ratio = ~0.32) to investigate the effect of biomass (switchgrass, pine residues) and bed materials (sand, CaO+ sand, Al 2 O 3 , and CaO + Al 2 O 3 ). All gasification products, such as synthesis gas (syngas), contaminant gases, tar, and biochar (solid) were comprehensively analyzed. The composition of biomass significantly impacted CO and H 2 yield from volatile combustible matter and fixed carbon. Further, the presence of CaO made the condition favorable for the water-gas shift (WGS) reaction combined with the CO 2 carbonation reaction, which increased H 2 concentration. Additional steam with CaO increased H 2 concentration closer to 50% (N 2 free condition) through the combination reactions of steam hydrocarbon reforming and WGS by producing 44 g H 2 /kg dry biomass and 143 g CO /kg dry biomass . The usage of steam reduced the overall yield of contaminant gases, whereas the usage of CaO or Al 2 O 3 decreased the amount of gasification tar by approximately 5.8–6.5 g tar /kg dry biomass . In conclusion, this study can provide valuable experimental data for biomass waste to produce better quality syngas.

08 HYDROGEN↗

Adsorption, Orientation, and Speciation of Amino Acids at Air–Aqueous Interfaces for the Direct Air Capture of CO 2

Amino acids make up a promising family of molecules capable of direct air capture (DAC) of CO 2 from the atmosphere. Under alkaline conditions, CO 2 reacts with the anionic form of an amino acid to produce carbamates and deactivated zwitterionic amino acids. The presence of the various species of amino acids and reactive intermediates can have a significant effect on DAC chemistry, the role of which is poorly understood. In this study, all-atom molecular dynamics (MD) based computational simulations and vibrational sum frequency generation (vSFG) spectroscopy studies were conducted to understand the role of competitive interactions at the air–aqueous interface in the context of DAC. We find that the presence of potassium bicarbonate ions, in combination with the anionic and zwitterionic forms of amino acids, induces concentration and charge gradients at the interface, generating a layered molecular arrangement that changes under pre- and post-DAC conditions. In parallel, an enhancement in the surface activity of both anionic and zwitterionic forms of amino acids is observed, which is attributed to enhanced interfacial stability and favorable intermolecular interactions between the adsorbed amino acids in their anionic and zwitterionic forms. The collective influence of these competitive interactions, along with the resulting interfacial heterogeneity, may in turn affect subsequent capture reactions and associated rates. Finally, these effects underscore the need to consider dynamic changes in interfacial chemical makeup to enhance DAC efficiency and to develop successful negative emission and storage technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and experimental evaluation of new building air leakage measurement methods: measurement of interior air leaks and comparison to conventional methods

Building air leaks (both through exterior and interior surfaces) can have a significant impact on energy consumption, indoor air quality, fire safety, and moisture accumulation affecting structural durability. Blower door testing has been used to measure leaks in buildings, but commonly used testing methods do not directly measure interior leaks. In this paper, new testing methods (guarded interior test and zonal multipoint pressure testing method) are presented that directly measure these interior leaks, utilizing common blower door equipment for both single and multi-point testing. Furthermore, these new methods are compared to conventional methods in terms of the information provided, limitations and time/effort needed. In addition, building leak measurement results are analyzed to reveal a) coupling between power law model values (exponent and coefficient) for an ensemble of buildings, b) the error in using single point testing when estimating low pressure leakage, and c) how building power law models vary from low to high pressure ranges.

99 GENERAL AND MISCELLANEOUS↗

Identifying Energy Inefficiencies in Compressed Air Systems: A Systematic Approach with the Compressed Air Scoping Tool

This paper highlights the importance of improving compressed air systems, outlines the tool’s development and features, and underscores its value as a nonbiased resource for system evaluation and optimization. Additionally, the paper presents a case study based on a food manufacturing facility to demonstrate the practical application of the tool. Furthermore, the paper discusses potential future opportunities for enhancing the CA Scoping Tool.

compressed air benchmarking↗

Analysis of the Ion Conversion Mechanisms in the Effluent of Atmospheric Pressure Plasma Jets in Ar with Admixtures of O 2 , H 2 O and Air

Ionic species in atmospheric pressure plasma jets (APPJs) play an important role in plasmasurface and plasma-liquid interactions, nonetheless, they have not received the same attention as their neutral reactive species counterparts. In this work, a molecular beam mass spectrometer (MBMS) was used to characterize the ion compositions in the effluent of an APPJ operating in ambient air for different feed gases including Ar + O 2 , Ar + air and Ar + H 2 O mixtures inspired by gas compositions used for biomedical applications. Changes in compositions of positive and negative ions as a function of nozzle-to-substrate distance along the plasma plume were analyzed and compared with a pseudo-1D plug flow model. Positive and negative ions were detected up to distances of 12 mm from the visible plasma plume tip. The measurements enable to follow the ion conversion pathways in the effluent of the APPJs as a function of distance from the nozzle. The trends in ion yield obtained from a pseudo-1D plug flow model showed generally a good agreement with the experimentally observed trends after addition of ionic reactions to the previously reported reaction set but also some distinctive differences were observed. The dominant positive ions in the far effluent are water ion clusters, the most stable ion for all gas mixtures investigated, while a large variety of negative ions was found for different gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗