High altitude air sampling with a rocketborne cryocondenser
Rocketborne cryogenic sampler using shock diffuser inlet for air collection at supersonic speeds during rocket ascent
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Rocketborne cryogenic sampler using shock diffuser inlet for air collection at supersonic speeds during rocket ascent
The feasibility of using W41 filter media on a routine TSP high-volume monitoring network was determined by comparison with glass fiber (GF) filtering. Results indicate that suspended particulate samples from GF filters averaged slightly, but not significantly, higher than those from Whatman-41 filters. Some extra handling procedures were required to avoid errors due to the hygroscopic nature of W41 filters; these added procedures are not overly burdensome, however, and they allow the performance of analytical work, thus extending the capabilities of high-volume sampling. It was demonstrated that W41 filters are practical for air quality monitoring and elemental analysis in environments similar to Cleveland's.
Environmental sampling methods developed by the Savannah River National Laboratory (SRNL) employ collectors with sorbent media tubes set at various locations to collect airborne emissions. Laboratory analyses of these tubes results in one-dimensional signals regarding what chemicals are being released and transported within the atmosphere. The analysis process is time consuming especially when analyzing a full year’s worth of tubes (hourly sample collection results in nearly 9,000 tubes per year). Using a signal processing method such as compressed sensing allows for recreation of the full signal while greatly reducing the number of analyzed samples required. Due to the sparsity of data retrieved from the air tubes, it is possible to use measurements a fraction of the size of the original data to gain much of the same information. This would improve the overall time and cost of analysis when modeling one-dimensional sampling signals.
Environmental sampling methods developed by the Savannah River National Laboratory (SRNL) employ collectors with sorbent media tubes set at various locations to collect airborne emissions. Laboratory analyses of these tubes results in one-dimensional signals regarding what chemicals are being released and transported within the atmosphere. The analysis process is time consuming especially when analyzing a full year’s worth of tubes (hourly sample collection results in nearly 9,000 tubes per year). Using a signal processing method such as compressed sensing allows for recreation of the full signal while greatly reducing the number of analyzed samples required. Due to the sparsity of data retrieved from the air tubes, it is possible to use measurements a fraction of the size of the original data to gain much of the same information. This would improve the overall time and cost of analysis when modeling one-dimensional sampling signals.
The F-Area wetlands are a known sink for radioiodine generated at the Savannah River Site (SRS). Wastewater containing iodine-129 ( 129 I) was discharged into the F-Area Seepage Basins for disposal, but the acidity of the wastewater mobilized some of the contaminants from the basin soil through the vadose zone and into the groundwater; ultimately creating a groundwater plume that extends towards Fourmile Branch and its associated wetland areas. Dissolved radioiodine specifically has migrated to the nearby F-Area wetlands, where it persists as a contaminant of concern. Accumulation and resurfacing of 129 I in the wetlands and nearby areas creates a potential secondary source zone where changes in biogeochemical conditions could result in the release of this sequestered 129 I to the air. Monitoring data has indicated that 129 I has a seasonal behavior at several surface water stations, with high concentrations during summertime and low concentrations during wintertime. Still, it is not known which factors control the seasonal behavior of 129 I. Further, it has been reported that 129 I contributed approximately 23% to the 2019 SRS offsite air pathway dose to the representative person for that year (SRNS, 2020), but air measurements of 129 I have never been taken in the F-Area wetlands. Because air emissions of 129 I from the wetlands have never been investigated, it is not known if this could be a potential release pathway that needs to be included in the site conceptual model. To address these unknowns, the Savannah River National Laboratory (SRNL) has an applied research task to investigate whether 129 I in the wetlands is emitted to the air and, if so, whether air concentrations exhibit seasonal variation. This report presents information about the system recently installed in the F-Area wetlands for measuring 129 I, as well as analysis results for samples collected June through August 2023. Quantification of this constituent will provide a better understanding of the contribution of airborne 129 I from the F-Area wetlands to the offsite dose and better inform ongoing and future remedial actions.
No abstract prepared.
Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.
The toxicological assessment of 6 GSCs from the ISS is shown. The average recoveries of the 3 surrogate standards from the grab sample containers were as follows: C-13-acetone, 115%; fluorobenzene, 108%; and chlorobenzene, 93%.
Particulate matter less than 10 {mu}m (PM10) has been shown to be associated with aggravation of asthma and respiratory and cardiopulmonary morbidity. There is also great interest in the potential health effects of PM2.5. Particulate matter (PM) varies in composition both spatially and temporally depending on the source, location and seasonal condition. El Paso County which lies in the Paso del Norte airshed is a unique location to study ambient air pollution due to three major points: the geological land formation, the relatively large population and the various sources of PM. In this study, dichotomous filters were collected from various sites in El Paso County every 7 days for a period of 1 year. The sampling sites were both distant and near border crossings, which are near heavily populated areas with high traffic volume. Fine (PM2.5) and Coarse (PM10-2.5) PM filter samples were extracted using dichloromethane and were assessed for biologic activity and polycyclic aromatic (PAH) content. Three sets of marker genes human BEAS2B bronchial epithelial cells were utilized to assess the effects of airborne PAHs on biologic activities associated with specific biological pathways associated with airway diseases. These pathways included in inflammatory cytokine production (IL-6, IL-8), oxidative stress (HMOX-1, NQO-1, ALDH3A1, AKR1C1), and aryl hydrocarbon receptor (AhR)-dependent signaling (CYP1A1). Results demonstrated interesting temporal and spatial patterns of gene induction for all pathways, particularly those associated with oxidative stress, and significant differences in the PAHs detected in the PM10-2.5 and PM2.5 fractions. Temporally, the greatest effects on gene induction were observed in winter months, which appeared to correlate with inversions that are common in the air basin. Spatially, the greatest gene expression increases were seen in extracts collected from the central most areas of El Paso which are also closest to highways and border crossings.
The toxicological assessments of 2 canisters (mini-GSC or GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The percent recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 Shuttle GSCs averaged 86, 100, and 87, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.
Characterization and quantification of livestock odorants is one of the most challenging analytical tasks because odor-causing gases are very reactive, polar and often present at very low concentrations in a complex matrix of less important or irrelevant gases. The objective of this research was to develop a novel analytical method for characterization of the livestock odorants including their odor character, odor intensity, and hedonic tone and to apply this method for quantitative analysis of the key odorants responsible for livestock odor. Sorbent tubes packed with Tenax TA were used for field sampling. The automated one-step thermal desorption module coupled with multidimensional gas chromatography-mass spectrometry/olfactometry system was used for simultaneous chemical and odor analysis. Fifteen odorous VOCs and semi-VOCs identified from different livestock species operations were quantified. Method detection limits ranges from 40 pg for skatole to 3590 pg for acetic acid. In addition, odor character, odor intensity and hedonic tone associated with each of the target odorants are also analyzed simultaneously. We found that the mass of each VOCs in the sample correlates well with the log stimulus intensity. All of the correlation coefficients (R{sup 2}) are greater than 0.74, and the top 10 correlation coefficients were greater than 0.90.
U.S. national and regional emissions of HFC-134a are derived for 2008-2012 based on atmospheric observations from ground and aircraft sites across the U.S. and a newly developed regional inverse model. Synthetic data experiments were first conducted to optimize the model assimilation design and to assess model-data mismatch errors and prior flux error covariances computed using a maximumlikelihood estimation technique. The synthetic data experiments also tested the sensitivity of derived national and regional emissions to a range of assumed prior emissions, with the goal of designing a system that was minimally reliant on the prior. We then explored the influence of additional sources of error in inversions with actual observations, such as those associated with background mole fractions and transport uncertainties. Estimated emissions of HFC-134a range from 52 to 61 Gg yr -1 for the contiguous U.S. during 2008-2012 for inversions using air transport from Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model driven by the 12km resolution meteorogical data from North American Mesoscale Forecast System (NAM12) and all tested combinations of prior emissions and background mole fractions. Estimated emissions for 2008-2010 were 20% lower when specifying alternative transport from Stochastic Time-Inverted Lagrangian Transport (STILT) model driven by the Weather Research and Forecasting (WRF) meteorology. Our estimates (for HYSPLIT-NAM12) are consistent with annual emissions reported by U.S. Environmental Protection Agency for the full study interval. The results suggest a 10-20% drop in U.S. national HFC-134a emission in 2009 coincident with a reduction in transportation-related fossil fuel CO 2 emissions, perhaps related to the economic recession. All inversions show seasonal variation in national HFC-134a emissions in all years, with summer emissions greater than winter emissions by 20-50%.
Not Available
Not provided.
Not provided.
Not Available
Bacillus anthracis is the potentially lethal etiologic agent of anthrax disease, and is a significant concern in the realm of biodefense. One of the cornerstones of an effective biodefense strategy is the ability to detect infectious agents with a high degree of sensitivity and specificity in the context of a complex sample background. The nature of the B. anthracis genome, however, renders specific detection difficult, due to close homology with B. cereus and B. thuringiensis. We therefore elected to determine the efficacy of next-generation sequencing analysis and microarrays for detection of B. anthracis in an environmental background. We applied next-generation sequencing to titrated genome copy numbers of B. anthracis in the presence of background nucleic acid extracted from aerosol and soil samples. We found next-generation sequencing to be capable of detecting as few as 10 genomic equivalents of B. anthracis DNA per nanogram of background nucleic acid. Detection was accomplished by mapping reads to either a defined subset of reference genomes or to the full GenBank database. Moreover, sequence data obtained from B. anthracis could be reliably distinguished from sequence data mapping to either B. cereus or B. thuringiensis. We also demonstrated the efficacy of a microbial census microarray in detecting B. anthracis in the same samples, representing a cost-effective and high-throughput approach, complementary to next-generation sequencing. Our results, in combination with the capacity of sequencing for providing insights into the genomic characteristics of complex and novel organisms, suggest that these platforms should be considered important components of a biosurveillance strategy.