Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

50 records · Page 3

A new method for operating a continuous-flow diffusion chamber to investigate immersion freezing: assessment and performance study

Abstract. Glaciation in mixed-phase clouds predominantly occurs through the immersion-freezing mode where ice-nucleating particles (INPs) immersed within supercooled droplets induce the nucleation of ice. Model representations of this process currently are a large source of uncertainty in simulating cloud radiative properties, so to constrain these estimates, continuous-flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion-freezing efficiencies of INPs. This study explored a new approach to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that previously had not been demonstrated to be possible. The conditioning section of the chamber was maintained at −20 ∘C and water relative humidity (RHw) conditions of 113 % to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 ∘C min−1) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified compact ice chamber (MCIC) was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne soil dusts from an arable region that had shown ice nucleation over a wide span of supercooled temperatures. Dry-dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne soil dust particles were sampled from an ambient aerosol inlet. The measured ice nucleation efficiencies of model aerosols that had a surface active site density (ns) metric were higher but mostly agreed within 1 order of magnitude compared to results reported in the literature.

54 ENVIRONMENTAL SCIENCES↗

Chemical Reaction and Flow Modeling in Fullerene and Nanotube Production

The development of processes to produce fullerenes and carbon nanotubes has largely been empirical. Fullerenes were first discovered in the soot produced by laser ablation of graphite [1]and then in the soot of electric arc evaporated carbon. Techniques and conditions for producing larger and larger quantities of fullerenes depended mainly on trial and error empirical variations of these processes, with attempts to scale them up by using larger electrodes and targets and higher power. Various concepts of how fullerenes and carbon nanotubes were formed were put forth, but very little was done based on chemical kinetics of the reactions. This was mainly due to the complex mixture of species and complex nature of conditions in the reactors. Temperatures in the reactors varied from several thousand degrees Kelvin down to near room temperature. There are hundreds of species possible, ranging from atomic carbon to large clusters of carbonaceous soot, and metallic catalyst atoms to metal clusters, to complexes of metals and carbon. Most of the chemical kinetics of the reactions and the thermodynamic properties of clusters and complexes have only been approximated. In addition, flow conditions in the reactors are transient or unsteady, and three dimensional, with steep spatial gradients of temperature and species concentrations. All these factors make computational simulations of reactors very complex and challenging. This article addresses the development of the chemical reaction involved in fullerene production and extends this to production of carbon nanotubes by the laser ablation/oven process and by the electric arc evaporation process. In addition, the high-pressure carbon monoxide (HiPco) process is discussed. The article is in several parts. The first one addresses the thermochemical aspects of modeling; and considers the development of chemical rate equations, estimates of reaction rates, and thermodynamic properties where they are available. The second part addresses modeling of the arc process for fullerene and carbon nanotube production using O-D, 1-D and 2-D fluid flow models. The third part addresses simulations of the pulsed laser ablation process using time-dependent techniques in 2-D, and a steady state 2-D simulation of a continuous laser ablation process. The fourth part addresses steady state modeling in O-D and 2-D of the HiPco process. In each of the simulations, there is a variety of simplifications that are made that enable one to concentrate on one aspect or another of the process. There are simplifications that can be made to the chemical reaction models , e.g. reduction in number of species by lumping some of them together in a representative species. Other simulations are carried out by eliminating the chemistry altogether in order to concentrate on the fluid dynamics. When solving problems with a large number of species in more than one spatial dimension, it is almost imperative that the problem be decoupled by solving for the fluid dynamics to find the fluid motion and temperature history of "particles" of fluid moving through a reactor. Then one can solve the chemical rate equations with complex chemistry following the temperature and pressure history. One difficulty is that often mixing with an ambient gas is involved. Therefore, one needs to take dilution and mixing into account. This changes the ratio of carbon species to background gas. Commercially available codes may have no provision for including dilution as part of the input. One must the write special solvers for including dilution in decoupled problems. The article addresses both ful1erene production and single-walled carbon nanotube (SWNT) production. There are at least two schemes or concepts of SWNT growth. This article will only address growth in the gas phase by carbon and catalyst cluster growth and SW T formation by the addition of carbon. There are other models that conceive of SWNT growth as a phase separation process from clusters me up carbon and metal catalyst, with the carbon precipitating from the cluster as it cools. We will not deal with that concept in this article. Further research is needed to determine the rates at which these composite clusters form, evaporate, and segregate.

Scott, Carl D.↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗

Thermoelectric Converter for Loop Heat Pipe Temperature Control: Experience and Lessons Learned

This paper describes the theoretical background and implementation methodology of using a thermoelectric converter (TEC) for operating temperature control of a loop heat pipe (LHP). In particular, experimental results from ambient and thermal vacuum tests of an LHP are presented for illustrations. The most commonly used state-of-the-art method to control the LHP operating temperature is to cold bias its compensation chamber (CC) and use an electrical heater to maintain the CC at the desired set point temperature. Although effective, this approach has its shortcomings in that the electrical heater can only provide heating to the CC, and the required power can be large under certain conditions. An alternative method is to use a TEC, which is capable of providing both heating and cooling to the CC. In this method, one side of the TEC is attached to the CC, and the other side is connected to the evaporator via a thermal strap. Using a bipolar power supply and a control algorithm, a TEC can function as a heater or a cooler, depending on the direction of the current flow. Extensive ground tests of several LHPs have demonstrated that a TEC can provide very tight temperature control for the CC. It also offers several additional advantages: (1) The LHP can operate at temperatures below its natural operating temperature at low heat loads; (2) The required heater power for a TEC is much less than that for an electrical heater; and (3) It enhances the LHP start-up success. Although the concept of using a TEC for LHP temperature control is simple, there are many factors to be considered in its implementation for space applications because the TEC is susceptible to the shear stress and yet has to sustain the dynamic load under the spacecraft launch environment. The added features that help the TEC to withstand the dynamic load will inevitably affect the TEC thermal performance. Some experiences and lessons learned are addressed in this paper.

Ku, Jentung↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life of a Six-Hour Hurricane

Hurricane Claudette developed from a weak vortex in 6 h as deep convection shifted from downshear into the vortex center, despite ambient vertical wind shear exceeding 10 m/s. Six hours later it weakened to a tropical storm, and 12 h after the hurricane stage a circulation center could not be found at 850 hPa by aircraft reconnaissance. At hurricane strength the vortex contained classic structure seen in intensifying hurricanes, with the exception of 7-12 C dewpoint depressions in the lower troposphere upshear of the center. These extended from the 100-km radius to immediately adjacent to the eyewall, where equivalent potential temperature gradients reached 6 K/km. The dry air was not present prior to intensification, suggesting that it was associated with vertical shear-induced subsidence upshear of the developing storm. It is argued that weakening of the vortex was driven by cooling associated with the mixing of dry air into the core, and subsequent evaporation and cold downdrafts. Evidence suggests that this mixing might have been enhanced by eyewall instabilities after the period of rapid deepening. The existence of a fragile, small, but genuinely hurricane-strength vortex at the surface for 6 h presents difficult problems for forecasters. Such a "temporary hurricane" in strongly sheared flow might require a different warning protocol than longer-lasting hurricane vortices in weaker shear.

Shelton, Kay L.↗

Combining Satellite Data and Spatial Analysis to Assess the UHI Amplitude and Structure within Urban Areas: The Case of Moroccan Cities

Landsat-8 surface temperature and the European Space Agency land cover are used to assess the impact of land cover on the Urban Heat Island (UHI) and Urban Heat Sink (UHS). We analyzed five Moroccan cities selected for their different local climate, size, and typology during summer at three different spatial scales. The results show multiple causes defining the different forms and amplitudes of the UHI, namely: the ambient climate, the proximity to the sea, the presence of landscaped areas, and the color of building roofs and walls. Contrary to what was expected, the vegetation was not systematically an island of coolness, either because of its typology or its irrigation status. In the coastal cities of Tangier and Casablanca, UHIs around 20°C are observed on the seaside, whereas a UHS of up to 11°C is observed between the city center and the southern periphery of Casablanca. A moderate amplitude UHI of 7°C is formed in the mountainous city of Ifrane. For cities built in desert-like environments, well-defined UHSs between 9°C and 12°C are observed in Smara and Marrakech, respectively. At a finer scale, towns recorded lower temperatures than their immediate surroundings, which are attributed to evaporation from irrigated plants.

Laila El Ghazouani↗

Thermal stress in degraded forests in the Brazilian Amazon Arc of Deforestation

Understanding thermal stress in tropical forests has taken on new urgency in light of accelerating climate change and expansion of deforestation and forest degradation. Degraded tropical forests in particular may be approaching critical temperature thresholds even more rapidly than intact forests, with implications for tree survival and ecosystem recovery. We investigate thermal stress in degraded tropical forests within the Brazilian Amazon Arc of Deforestation. Using land surface temperature data from the ECOsystem Spaceborne Thermal Radiometer Experiment on the international Space Station (ECOSTRESS), we compared canopy temperatures of intact, selectively logged, and burned forests in Feliz Natal, Mato Grosso, Brazil. Upper canopy temperatures in previously burned forests were 4.1% higher (mean = 36.5 °C) and 50.9% more variable compared to intact and logged forests, which showed remarkably similar temperature distributions (means of 34.9 °C and 35.1 °C, respectively). Modeled leaf temperature distributions based on canopy temperature measurements from one of the warmest days in a 2 year dry season record indicated that 87% of leaves in the warmest burned forest patches exceeded the temperature threshold where respiration surpasses photosynthesis, compared to approximately 72%–74% in intact and logged forests, respectively, in the same time period. After controlling for environmental factors, burned forests were predicted to be 2.6 °C warmer on average [1.39 °C–3.96 °C, 95% credible interval] than intact forests across a 5–40 m canopy height range. Burned forests showed modest thermal recovery over time, with temperatures decreasing by approximately 1.2 °C over a 30 year recovery period. In contrast, logged forests showed minimal thermal differences from intact forests (−0.353 on average, [−1.125–0.274, 95% credible interval]) and negligible change (0.15 °C) over the same timeframe. While the absolute probabilities of exceeding damaging thermal thresholds remain low across all forest types under current climate conditions, the probability of leaves exceeding temperatures that cause permanent leaf damage was ten times higher in burned forests, with implications for the future of burned forest regeneration in water-limited regions of the Amazon basin. In particular, the combination of higher mean temperatures, greater temperature variability, and more frequent exposure to damaging thermal thresholds implies that burned tropical forests will experience substantially higher mortality rates and slower biomass recovery compared to intact and selectively logged forests, especially in water-limited regions where trees cannot rely on evaporative cooling to moderate canopy temperatures.

Brazilian Amazon Arc of Deforestation↗

Reducing Sample Loss in Measurement of Heat of Vaporization of Ethanol/Gasoline Blends by Differential Scanning Calorimetry/Thermogravimetric Analysis

Higher gasoline Heat of Vaporization (HOV) can enable higher compression-ratio direct injection spark ignition engines by providing evaporative cooling that effectively increases fuel knock resistance. Methods to directly measure this fuel property in complex gasoline samples are not well developed. The objective of the present study was to further improve a Differential Scanning Calorimetry/Thermogravimetric Analyzer (DSC/TGA) method to measure the total and partial HOV of gasoline. Ten market gasoline samples were chosen to have a wide range of properties to assess the method's capability across the entire volatility range with an emphasis on understanding how well the method captures the initial 10 percent (%) of sample evaporation and how much sample is left unevaporated at the end of the experiment. Modifications to the sample preparation/introduction method as well as to the instrument itself were made to reduce initial sample losses which included measurements of the HOV at 10 degrees C and 5 degrees C (in a cold chamber) as well as under (uncontrolled) ambient conditions. Experimental results from the DSC/TGA were compared to calculated total HOV results based on Detailed Hydrocarbon Analysis (DHA). Results from the two methods agreed very well with the difference being 5% or less in almost every case. In addition, the repeatability of the method was investigated by analyzing samples in triplicate at the three temperatures investigated. One valuable conclusion from the study was that the lower temperatures of 10 degrees C and 5 degrees C enabled more reproducible measurements for both total and partial HOV. This improved precision may be caused by the fact that temperature control in the cold chamber was more reliable than the ambient laboratory temperature control. Additionally, cold chamber experiments, due to ergonomic limitations, did not allow for the use of a lid on the sample pan. The reproducibility of the evaporation rate was found to be highly dependent on the pan/lid fit which can vary significantly such that elimination of the lid improved measurement precision while operation at sub-ambient temperature slowed the evaporation rate. Results detailing sample preparation and instrument modifications as well as a detailed comparison of total and partial HOV results are presented.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Two-Stage Autoignition Dynamics of N-Dodecane Droplets Under Normal Gravity at High Pressures

Experimental observations of two-stage, autoignition characteristics of fiber-supported, n-dodecane fuel droplets under normal gravity are reported for a wide range of ambient temperatures, and pressures varying from 1 atm to 25 atm, which encompasses the fuel critical pressure (~ 18 atm). A high-speed camera is used to obtain backlit images of the autoignition process. During two-stage ignition, a cool-flame front forms below the droplet in the natural convective plume of the fuel vapor originating from the vaporizing droplet, and propagates upward, followed by the formation of a hot-flame kernel that expands rapidly and surrounds the droplet, eventually leading to the classical diffusion flame. Experimentally measured cool, and hot flame formation locations and propagation speeds are presented for varying initial temperatures and pressures. Measured first, and second stage ignition delay times are also reported. The influences of negative temperature coefficient (NTC) regime chemistry on flame starting location, propagation speeds, and ignition delay times are described. The first-stage cool flame characteristics are found to be controlled by both the chemistry, and physical aspects such as droplet evaporation and fuel-oxidizer mixing, while the second-stage hot flame ignition is primarily controlled by chemical kinetics. Further work is currently underway to develop models to quantitatively predict the observed behavior.

Rose, Evan↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Real-time optimization of multi-cell industrial evaporative cooling towers using machine learning and particle swarm optimization

Existing electrical generating stations must operate with greater flexibility due to increasing renewable energy penetration on the electrical grid, and many coal-fired power stations have transitioned away from baseload operation to load-following operation to aid in grid stability. In cases where multiple independently controlled cooling tower cells are used in parallel for the cooling purposes of such stations, there is an opportunity to increase plant efficiency through data-driven optimization across their full load ranges. This work presents a novel application of real-time optimization using machine learning and particle swarm optimization on a multi-cell induced-draft cooling tower servicing a coal-fired power station under variable load. This is the first work to demonstrate simultaneous optimization of a multi-cell cooling tower, in addition to using machine learning for closed-loop control on a cooling tower. A novel control configuration is presented that ensures original control logic is not adversely affected and that the overall plant process is not disrupted using only existing hardware and operational data. To verify this methodology, the 12 independent cooling tower cells are simulated in parallel using historic operating data to demonstrate the effectiveness of real-time optimization compared to current practice. An artificial neural network is trained to predict overall cooling tower power consumption using only operational data and ambient conditions with an R2 value of greater than 0.96. The real-time optimization using particle swarm yields 6.7% annual energy usage savings compared to current practices, although the extent of the real-time savings varies greatly with both plant load and environmental conditions. This is particularly significant for a variable load situation because frequent ramping typically results in reduced overall efficiency. Furthermore, this proposed AI-based solution presents an opportunity to improve the overall heat rate of a load-following coal-fired power plant without the need to perform extensive first-principles modeling or add additional hardware to the cooling tower, resulting in more resources conserved and less overall emissions per unit of electricity generated.

42 ENGINEERING↗

Water Quality Contamination Sources and Controls for the Exploration Extra-vehicular Mobility Unit (xEMU)

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. The xEMU uses controlled evaporative cooling through a membrane to reject waste heat from the crewmember, avionics, and environmental in-leak during autonomous operation. Given the unique mass and volume constraints imposed by the spacesuit application and the opportunities presented by the selection of a given membrane, the xEMU does not possess a separate feedwater loop to feed the evaporation process, rather the feedwater for the evaporation process is fed directly from the transport loop which collects heat from the sources within the suit. This has many benefits including mass/volume reductions from a lower component count within the system but does pose some additional potential constraints on water quality within the system in order to provide a working fluid that can be pumped, filtered, and used in contact with the remainder of the system while both avoiding fouling of the membrane as well as other deleterious effects such as creating conditions for corrosion of wetted surfaces within the transport loop. The discussion will seek to address the main sources of contamination and the applied controls. Sources considered will include: self-generated via materials selection and processes applied, influent working fluid, contamination of the influent working fluid via Ground Support Equipment (GSE) or processing equipment, microbial activity, and environmental influences such as elevated ambient CO2.

Colin Campbell↗

Development of a Battery-Free Solar Refrigerator

Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.

Ewert, Michael K.↗