Search NASA⌕ Search

SEARCH · Search NASA

Results for “analysis of kinetic data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Solar-simulator-pumped atomic iodine laser kinetics

The literature contains broad ranges of disagreement in kinetic data for the atomic iodine laser. A kinetic model of a solar-simulator-pumped iodine laser is used to select those kinetic data consistent with recent laser experiments at the Langley Research Center. Analysis of the solar-simulator-pumped laser experiments resulted in the following estimates of rate coefficients: for alkyl radical (n-C3F7) and atomic iodine (I) recombination, 4.3 x 10 to the 11th power (1.9) + or - cu cm/s; for n-C3F7I stabilized atomic iodine recombination (I + I) 3.7 x 10 to the -32nd power (2.3) + or -1 cm to the 6th power/s; and for molecular iodine (I2) quenching, 3.1 x 10 to the -11th power (1.6) + or - 1 cu cm/s. These rates are consistent with the recent measurements.

Wilson, H. W.↗

The role of oxygen in porous molybdenum electrodes for the alkali metal thermoelectric converter

A model for chemical reactions in porous molybdenum electrodes is presented which is based on thermochemical and kinetic data, known sodium-molybdenum-oxygen chemistry, X-ray diffraction analysis of molybdenum and molybdenum oxide electrodes, and the electrochemical behavior of the cell. Enhanced sodium transport through the electrode in its optimum performance state is found to be due to the high sodium ion conductivity of molten Na2MoO4 in the pores, and the electrical conduction to the molybdenum matrix by Na2Mo3O6. The decline of electrode performance is shown to be due to a combination of loss mechanisms for the Na-Mo-O compounds including reduction at short circuit, disproportionation of Na2Mo3O6 at open circuit, and the evaporation of Na2MoO4 at elevated temperature. It is suggested that operation of the cell at moderate voltage of about 0.5 V corresponding to maximum power may be a more stable condition for the porous electrode than open-circuit stand or short-circuit, where degradation reactions are heightened.

Williams, R. M.↗

Vaporization and Zonal Mixing in Performance Modeling of Advanced LOX-Methane Rockets

Initial modeling of LOX-Methane reaction control (RCE) 100 lbf thrusters and larger, 5500 lbf thrusters with the TDK/VIPER code has shown good agreement with sea-level and altitude test data. However, the vaporization and zonal mixing upstream of the compressible flow stage of the models leveraged empirical trends to match the sea-level data. This was necessary in part because the codes are designed primarily to handle the compressible part of the flow (i.e. contraction through expansion) and in part because there was limited data on the thrusters themselves on which to base a rigorous model. A more rigorous model has been developed which includes detailed vaporization trends based on element type and geometry, radial variations in mixture ratio within each of the "zones" associated with elements and not just between zones of different element types, and, to the extent possible, updated kinetic rates. The Spray Combustion Analysis Program (SCAP) was leveraged to support assumptions in the vaporization trends. Data of both thrusters is revisited and the model maintains a good predictive capability while addressing some of the major limitations of the previous version.

Williams, George J., Jr.↗

Data Analysis for the Scintillating Optical Fiber Calorimeter (SOFCAL)

The scintillating optical fiber calorimeter is a hybrid instrument with both active and passive components for measuring the proton and helium cosmic ray spectra from 0.2 to IO TeV kinetic energy. A thin emulsion/x-ray film chamber is situated between a cerenkov counter and an imaging calorimeter. Scintillating optical fibers sample the electromagnetic showers that develop in the calorimeter and identify the trajectory of cosmic rays that interact in SOFCAL. The emulsion/x-ray film data provide an in flight calibration for SOFCAL. The data reduction techniques used will be discussed and interim results of the analysis from a 20 hour balloon flight will be presented.

Christl, Mark J.↗

Energetics analysis of the global circulation during the special observation periods of FGGE

A global energetics analysis is presented for the FGGE SOP-1 and SOP-2 with ECMWF and GFDL data sets. Both global integral properties and spectral characteristics are examined. There is a large discrepancy between the present FGGE analysis and previously available estimates concerning the level of available potential energy and kinetic energy. This discrepancy is attributable to an earlier restriction of data coverage. There is a significant seasonal difference in the energy reservoir of the Northern Hemisphere, whereas the diference is minor in the Southern Hemisphere. This leads to a seasonal contrast of the globally integrated energy budget which comes mostly from the Northern Hemisphere. Both the global energy level and the intensity of the general circulation are more pronounced during SOP-1 than during SOP-2. One major focus of attention in this study is an energetics comparison of ECMWF and GFDL data sets. There is a twofold difference in the intensity of the general circulation as measured with these two data sets. The energetics diagnosis indicates that the operational modes of the general circulation as described by these two data sets also differ considerably. The contrasts between SOP-1 and SOP-2 and between the ECMWF and GFDL versions of the data sets are apparent in the pattern of energy flow in the wavenumber domain.

Kung, E. C.↗

Kinetic energy budgets in areas of intense convection

A kinetic energy budget analysis of the AVE-SESAME 1 period which coincided with the deadly Red River Valley tornado outbreak is presented. Horizontal flux convergence was found to be the major kinetic energy source to the region, while cross contour destruction was the major sink. Kinetic energy transformations were dominated by processes related to strong jet intrusion into the severe storm area. A kinetic energy budget of the AVE 6 period also is presented. The effects of inherent rawinsonde data errors on widely used basic kinematic parameters, including velocity divergence, vorticity advection, and kinematic vertical motion are described. In addition, an error analysis was performed in terms of the kinetic energy budget equation. Results obtained from downward integration of the continuity equation to obtain kinematic values of vertical motion are described. This alternate procedure shows promising results in severe storm situations.

Fuelberg, H. E.↗

Nitrogen recombination on high-temperature reusable surface insulation and the analysis of its effect on surface catalysis

The energy transfer catalytic recombination coefficients for nitrogen and oxygen on a borosilicate glass are determined in nitrogen and air hypersonic arc jet streams. These data, obtained from a reacting boundary-layer analysis with first-order surface reaction kinetics, compare well with earlier results from a Goulard frozen boundary-layer model up to 1600 K. The apparent surface recombination rates increase up to 1600 K, then begin to decrease. To illustrate the effects of temperature and nitrogen dissociation on energy transfer to the glass, a diffusional heat-flux is calculated using the present results from 1450 K up to 1850 K. This diffusional heat-flux is the contribution to the total heating rate by atom recombination, and is used to compare the present results with coefficients from three previous studies.

Kolodziej, Paul↗

3D Material Response Analysis of PICA Pyrolysis Experiments

The PICA decomposition experiments of Bessire and Minton are investigated using 3D material response analysis. The steady thermoelectric equations have been added to the CHAR code to enable analysis of the Joule-heated experiments and the DAKOTA optimization code is used to define the voltage boundary condition that yields the experimentally observed temperature response. This analysis has identified a potential spatial non-uniformity in the PICA sample temperature driven by the cooled copper electrodes and thermal radiation from the surface of the test article (Figure 1). The non-uniformity leads to a variable heating rate throughout the sample volume that has an effect on the quantitative results of the experiment. Averaging the results of integrating a kinetic reaction mechanism with the heating rates seen across the sample volume yield a shift of peak species production to lower temperatures that is more significant for higher heating rates (Figure 2) when compared to integrating the same mechanism at the reported heating rate. The analysis supporting these conclusions will be presented along with a proposed analysis procedure that permits quantitative use of the existing data. Time permitting, a status on the in-development kinetic decomposition mechanism based on this data will be presented as well.

Oliver, A. Brandon↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/ absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗

A novel implementation of method of optimality criterion in synthesizing spacecraft structures with natural frequency constraints

In the design of spacecraft structures, fine tuning the structure to achieve minimum weight with natural frequency constraints is a time consuming process. Here, a novel implementation of the method of optimality criterion (OC) is developed. In this new implementation of OC, the free vibration analysis results are used to compute the eigenvalue sensitivity data required for the formulation. Specifically, the modal elemental strain and kinetic energies are used. Additionally, normalized design parameters are introduced as a second level linking that allows design variables of different values to be linked together. With the use of this novel formulation, synthesis of structures with natural frequency constraint can be carried out manually using modal analysis results. Design examples are presented to illustrate this novel implementation of the optimality criterion method.

Wang, Bo Ping↗

Overall Traveling-Wave-Tube Efficiency Improved By Optimized Multistage Depressed Collector Design

Depressed Collector Design The microwave traveling wave tube (TWT) is used widely for space communications and high-power airborne transmitting sources. One of the most important features in designing a TWT is overall efficiency. Yet, overall TWT efficiency is strongly dependent on the efficiency of the electron beam collector, particularly for high values of collector efficiency. For these reasons, the NASA Glenn Research Center developed an optimization algorithm based on simulated annealing to quickly design highly efficient multistage depressed collectors (MDC's). Simulated annealing is a strategy for solving highly nonlinear combinatorial optimization problems. Its major advantage over other methods is its ability to avoid becoming trapped in local minima. Simulated annealing is based on an analogy to statistical thermodynamics, specifically the physical process of annealing: heating a material to a temperature that permits many atomic rearrangements and then cooling it carefully and slowly, until it freezes into a strong, minimum-energy crystalline structure. This minimum energy crystal corresponds to the optimal solution of a mathematical optimization problem. The TWT used as a baseline for optimization was the 32-GHz, 10-W, helical TWT developed for the Cassini mission to Saturn. The method of collector analysis and design used was a 2-1/2-dimensional computational procedure that employs two types of codes, a large signal analysis code and an electron trajectory code. The large signal analysis code produces the spatial, energetic, and temporal distributions of the spent beam entering the MDC. An electron trajectory code uses the resultant data to perform the actual collector analysis. The MDC was optimized for maximum MDC efficiency and minimum final kinetic energy of all collected electrons (to reduce heat transfer). The preceding figure shows the geometric and electrical configuration of an optimized collector with an efficiency of 93.8 percent. The results show the improvement in collector efficiency from 89.7 to 93.8 percent, resulting in an increase of three overall efficiency points. In addition, the time to design a highly efficient MDC was reduced from a month to a few days. All work was done in-house at Glenn for the High Rate Data Delivery Program. Future plans include optimizing the MDC and TWT interaction circuit in tandem to further improve overall TWT efficiency.

Vaden, Karl R.↗

Low Gravity Rapid Thermal Analysis of Glass

It has been observed by two research groups that ZrF4-BaF2-LaF3-AlF3-NaF (ZBLAN) glass crystallization is suppressed in microgravity. The mechanism for this phenomenon is unknown at the present time. In order to better understand the mechanism, an experiment was performed on NASA's KC135 reduced gravity aircraft to obtain quantitative crystallization data. An apparatus was designed and constructed for performing rapid thermal analysis of milligram quantities of ZBLAN glass. The apparatus employs an ellipsoidal furnace allowing for rapid heating and cooling. Using this apparatus nucleation and crystallization kinetic data was obtained leading to the construction of time-temperature-transformation curves for ZBLAN in microgravity and unit gravity.

Tucker, Dennis S.↗

Electron trapping in rad-hard RCA IC's irradiated with electrons and gamma rays

Enhanced electron trapping has been observed in n-channels of rad-hard CMOS devices due to electron and gamma-ray irradiation. Room-temperature annealing results in a positive shift in the threshold potential far beyond its initial value. The slope of the annealing curve immediately after irradiation was found to depend strongly on the gate bias applied during irradiation. Some dependence was also observed on the electron dose rate. No clear dependence on energy and shielding over a delidded device was observed. The threshold shift is probably due to electron trapping at the radiation-induced interface states and tunneling of electrons through the oxide-silicon energy barrier to fill the radiation-induced electron traps. A mathematical analysis, based on two parallel annealing kinetics, hole annealing and electron trapping, is applied to the data for various electron dose rates.

Danchenko, V.↗

Rectangular subsonic jet flow field measurements

Flow field measurements are presented of 3 subsonic rectangular cold air jets. The 3 cases presented had aspect ratios of 1 x 2, 1 x 4 at a Mach number of 0.09 and an aspect ratio of 1 x 2 at a Mach number of 0.9. All measurements were made using a 3-D laser Doppler anemoneter system. The presented data includes the mean velocity vector, all Reynolds stress tensor components, turbulent kinetic energy and velocity correlation coefficients. The data is presented in tabular and graphical form. No analysis of the measured data or comparison to other published data is made. All tabular data are available in ASCII format on MS-DOS compatible disks.

Morrison, Gerald L.↗

Rectangular subsonic jet flow field measurements

Flow field measurements of three subsonic rectangular cold air jets are presented. The three cases had aspect ratios of 1x2, 1x4 at a Mach number of 0.09 and an aspect ratio of 1x2 at a Mach number of 0.9. All measurements were made using a 3-D laser Doppler anemometer system. The data includes the mean velocity vector, all Reynolds stress tensor components, turbulent kinetic energy and velocity correlation coefficients. The data are presented in tabular and graphical form. No analysis of the measured data or comparison to other published data is made.

Morrison, Gerald L.↗

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi↗