Search NASA⌕ Search

SEARCH · Search NASA

Results for “and lower operating pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Data-driven simultaneous process optimization and adsorbent selection for vacuum pressure swing adsorption

Technologies for post-combustion carbon capture are essential for the reduction of greenhouse gas emissions to the atmosphere. However, they are still associated with high costs and energy consumption. Intensified processes for carbon capture have the potential to overcome these challenges due to their higher efficiency, lower capital cost, and increased operational flexibility. Here, this work investigates simultaneous optimization of process conditions and adsorbent selection for a modular Vacuum Pressure-Swing Adsorption system designed for CO 2 capture. Both surrogate-based Nonlinear Programming and Mixed-Integer Nonlinear Programming approaches are applied and compared in terms of computational efficiency and solution accuracy. Moreover, process performance results are examined by applying several data analytics techniques to gain insights into the material-process correlations. Data-driven classifiers and neural networks can accurately predict whether a material is likely to satisfy purity, recovery, and energy constraints when operated at optimal process conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mesofluidic Inline Separation for Produced Water Treatment

Mesofluidic inline separation developed by PNNL represents an opportunity to remove a key barrier in the treatment of produced water, namely suspended solids that clog downstream operations. The US alone produces over 800 billion gallons of produced water each year, most of which is reinjected underground (but not into the aquifers) as waste. The impact from treating and reusing even a fraction of this wastewater is immense as aquifers in the Midwest and elsewhere dry. The work described herein is essential to leveraging the opportunity to improve produced water quality (to allow for beneficial use) by combining mesofluidic inline separators with reverse osmosis systems. Providing water for agricultural and industrial uses in the American Southwest and Midwest by allowing the reuse of petroleum produced water may be critical to the long-term economics of the region. This is especially true as drought conditions are rapidly lowering aquifer levels in these regions. The incumbent technology for desalination is reverse osmosis (RO) due to its ability to treat a wide range of feedwaters and technological maturity. However, suspended solids cause RO (and other dissolved solids removal technologies) to become clogged and loose performance. A common strategy is to use prefilters upstream of RO systems, but these membrane-based filters easily clog and require regular maintenance. Unlike membrane filters, mesofluidic inline separators provide removal of suspended solids with much lower pressure drops than conventional systems filtration systems, permitting substantially higher flowrates. Although the amount of produced water from petroleum operations is vast, only a small fraction of it is reused or turned into potable water, for example, because of the lack of technologies to remove both dissolved and suspended solids at a significant throughput. This project shows that mesofluidic inline separators coupled with a commercial dissolved solids removal technology (RO) are positioned to do exactly that. Mesofluidic inline separators fit within commercial piping and are tunable for particle sizes of interest as described below. Indeed, mesofluidic inline separators have remarkably smaller footprints than competing filtration technologies and are easily transportable from jobsite to jobsite. This technology has no moving parts so that solids removal can be accomplished at much lower operating cost.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of an All-Refractory Corrosion-Resistant Molten Salt Pumping and Storage Infrastructure Up to 950 degrees C

Concentrating solar power (CSP) with thermal energy storage (TES) has an estimated cost similar to solar photovoltaics (PV) with lithium-ion batteries (LIB), but CSP + TES has the potential for significantly reduced cost by operating above 700 degrees C. However, this requires a TES medium and containment infrastructure which are chemically compatible and do not degrade above 700 degrees C. MgCl2-KCl-NaCl (MKN) salt is a promising medium, but when MKN salt has small amounts of water and oxygen dissolved in it, it excessively corrodes conventional commercial alloys. Here, we consider refractory materials including graphite, carbon-carbon composite (C/C), and molybdenum because they maintain high mechanical strength at elevated temperatures and are expected to resist corrosion by MKN salt. While selection of refractory materials is often constrained by the need to remain chemically stable in air, this work uses an enclosure filled with inert gas to allow the use of materials like graphite and molybdenum. Notably, graphite components can seal against liquids unlike many brittle refractory materials. We demonstrate a centrifugal pump and mechanical seals made of refractory materials in a laboratory-scale circulation loop, which successfully operated continuously for more than 49 h at temperatures ranging from 750 degrees C to 950 degrees C with no mechanical failures or chemical degradation of the refractory materials. To the best of our knowledge, this is the highest temperature molten salt circulation loop that has been successfully developed, and this refractory infrastructure allows for operation at even much higher temperatures (<1600 degrees C) if a storage medium with a lower vapor pressure is used. The principles of this architecture are relevant to other applications with high temperature flowing metals and salts including Generation IV nuclear fission reactors for power production and molten salt electrolysis reactors for metallurgical processing.

14 SOLAR ENERGY↗

Advancing Li-plating detection: Motivating a multi-signal correlation approach

Facilitating fast charging in lithium-ion batteries (LiBs) is often linked to Li-plating, which harms performance, longevity, and safety. Early detection of Li-plating is essential for rapid technological development and for preventing performance deterioration and ensuring safety during operation. Fast and real-time detection, using commonly collected measurements like voltage (V), current (I), temperature (T), and pressure (P), is highly desirable. Existing standalone methods relying on electrochemical and mechanical signatures, using half, smaller, or specially designed cells often operated at lower temperatures, fail to account for real-world fast-charging conditions. These signatures may also have inherent unreliability in aged LiBs, a phenomenon currently not-well understood. All these uncertainties have complicated practical implementation of a robust Li-plating detection technique. This study, through multiple case studies involving real-world fast-charging conditions using automotive-grade 11.6 Ah LiBs, shows that many single signal-based diagnostic techniques may be inadequate to detect Li-plating. Among various signatures, end-of-charge rest pressure, differential pressure-sensing, and end-of-charge rest voltage were identified as particularly useful in detecting Li-plating. Furthermore, A multi-signal-based detection technique is shown to be more robust in detecting Li-plating. Using both fresh and aged cells, the results and analysis highlight how detection capabilities are influenced by various factors, including battery design, size, charging speed, operating temperature, and degradation level. Adopting such a multi-signal Li-plating detection approach may be instrumental in the rapid development of battery technology in laboratories, as well as ensuring the enhanced safety of next-generation LiBs in real-world fast-charging applications.

25 ENERGY STORAGE↗

Extending the Operating Envelope for an Extremely Low NOx Axial Stage Combustion System

The overall goal of this program is to develop a low NOx combustion system which enables a gas turbine combined cycle efficiency of > 65%. The proposed combustion system is a combination of three advanced technologies under development by the Recipient: advanced transition design, the Distributed Combustion System (DCS), and advanced head end. Of note is that the DCS and advanced transition were initially developed with DOE funding under previous Cooperative Agreements. The continued development of these designs has resulted in a proof of concept design which was successfully tested in the Recipient’s state-of-the-art high-pressure rig. The initial rig testing indicated a substantial benefit with respect to high firing temperature operation as well as low NOx operation for the advanced transition and the DCS. Even lower NOx and higher firing temperatures are possible with the addition of the advanced head end to the design. Potential hurdles to the combustion design have been identified, such as high pressure drop and acoustics. The goal of this program is to develop variations of this design which address these hurdles and create an optimized design for implementation into the Recipient’s new high efficiency gas turbine engine.

03 NATURAL GAS↗

Evaluation of the economic implications of varied pressure drawdown strategies generated using a real-time, rapid predictive, multi-fidelity model for unconventional oil and gas wells

Experience has suggested that pressure maintenance in hydraulically fractured reservoirs via lower, more sustained production drawdowns may offer improved cumulative recovery and overall resource extraction efficiency compared to more rapid drawdown approaches aimed at generating high initial production. However, given the inherent variability of oil and natural gas markets, operators pursue production strategies that maximize profitability over resource extraction efficiency. This study focuses on evaluating the implications of contrasting pressure drawdown strategies on the long-term production and resulting economics for a real, producing unconventional gas well in the Marcellus Shale of the Appalachian Basin using a techno-economic analysis approach. Our research combines elements of well-specific horizontal well design, production forecasting, equipment sizing and capital cost estimation, operating cost estimation, and revenue and tax calculations. Gas production forecast outlook scenarios were generated under varying pressure drawdowns using two approaches: 1) a novel physics-informed machine learning workflow and 2) traditional reservoir simulation. A discounted cash flow model was used to evaluate the resulting economic implications for each drawdown scenario—generating output for exploring the coupled effect of factors like the timing and volume of gas production, prevailing economic and market conditions for natural gas, and overall estimated ultimate recovery on profitability metrics such as internal rate of return and net present value. Results show that there is potential to maximize the cumulative gas produced in the specific case study well by employing a lower pressure drawdown. Conversely, the greatest profitability is achieved using rapid drawdown as signified by a small, specific subset of our outlook scenarios. On an averaging basis, we find that the combinations of highest cumulative producing and most profitable scenarios occur under lower drawdowns with long (>40 years) producing timeframes, but require higher relative gas price and lower discounting considerations. Further, the machine learning predictive outlooking capability proved effective for enabling rapid generation of a multitude of scenario forecasts. As a result, a variety of prominent example cases could be generated to strike the balance of greater productivity and economic return given their associated producing features and economic conditions when compared to similar producing scenarios—critical insight that offers improved decision support for unconventional oil and gas operations.

42 ENGINEERING↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Investigating instabilities in magnetized low-pressure capacitively coupled RF plasma using particle-in-cell (PIC) simulations

The effect of a uniform magnetic field on particle transport in low-pressure radio frequency (RF) capacitively coupled plasma (CCP) has been studied using a particle-in-cell model. Three distinct regimes of plasma behavior can be identified as a function of the magnetic field. In the first regime at low magnetic fields, asymmetric plasma profiles are observed within the CCP chamber due to the effect of $\overrightarrow{E}$ × $\overrightarrow{B}$ drift. As the magnetic field increases, instabilities develop and form self-organized spoke-shaped structures that are distinctly seen within the bulk plasma closer to the sheath. In this second regime, the spoke-shaped coherent structures rotate inside the plasma chamber in the -$\overrightarrow{E}$ × $\overrightarrow{B}$ direction, where $\overrightarrow{E}$ × $\overrightarrow{B}$ are the DC electric and magnetic field vectors, respectively, and the DC electric field exists in the sheath and pre-sheath regions. The spoke rotation frequency is in the megahertz range. As the magnetic field strength increases further, the rotating coherent spokes continue to exist near the sheath. The coherent structures are, however, accompanied by new small-scale incoherent structures originating and moving within the bulk plasma region away from the sheath. This is the third regime of plasma behavior. The threshold values of the magnetic field between these regimes were found not to vary with changing plasma reactor geometry (e.g., area ratio between ground and powered electrodes) or the use of an external capacitor between the RF-powered electrode and the RF source. The threshold values of the magnetic field between these regimes shift toward higher values with increasing gas pressure. Analysis of the results indicates that the rotating structures are due to the lower hybrid instability driven by density gradients and electron-neutral collisions. This paper provides guidance on the upper limit of the magnetic field for instability-free operation in low-pressure CCP-based semiconductor deposition and etch systems that use the external magnetic field for plasma uniformity control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical Simulations of Geologic Storage Reservoir Management to Support Risk Mitigation Evaluation

This report provides a detailed description of a set of numerical simulations that represent reservoir behavior over time in response to different operational decision scenarios for detection of potential leakage and reduction or avoidance of leakage impact at a hypothetical geological carbon storage (GCS) site. These simulations serve as the basis for a series of GCS leakage risk forecasts that are to be developed using the National Risk Assessment Partnership’s Open-Source Integrated Assessment Model (NRAP-Open-IAM), and a demonstration of a simple decision support workflow for evaluation of mitigation strategies based on results of those system model forecasts. This risk assessment and decision support study is forthcoming. Four injection scenarios were considered: a constant rate carbon dioxide (CO 2 ) injection case (base case), a case with CO 2 injection rate adjustment, a case with early termination of injection operations, and a case with brine extraction. CO 2 injection operations were controlled to ensure that the pressure transient remains below the defined manageable reservoir fracture pressure, with consideration shown to hypothetical locations within the modeled spatial domain where the overburden was weaker and lower transient pressure increases were allowable. Additionally, a brine extraction alternative was considered as a reservoir management and risk mitigation option to reduce reservoir pressure, steer the plume away from any hypothetical geohazard such as fault as needed, and enhance storage capacity. Such operational actions contribute to risk management overtime. This study explores the potential utility of reservoir management for risk reduction at GCS sites. This study shows that the injection design may modify the time to CO 2 breakthrough at a legacy well; in particular, these results show that brine extraction can add value for mitigating risk both by delaying leakage and reducing pressure build-up. For the scenario considered, both pressure plots and pressure distributions demonstrate that pressure build-up was decreased by 3% with brine extraction. Additionally, extraction of brine afforded enhancement of CO 2 storage capacity by 5% compared to the base case. These findings suggest that brine extraction has substantial potential to steer the risk-related reservoir effects away from known geohazards (e.g., faults and legacy wells) by conducting pressure transient effects and CO 2 plume movement toward the production well. Injection rate adjustment scenarios considered in this study show potential value for managing both reservoir pressure transients and CO 2 plume behavior. Operational actions for reducing injection and/or early termination of injection (as compared to the base case), however, require careful design; tailoring both the extent and timing of injection rate adjustment over the injection and post-injection operational period must be thoroughly planned to balance maximizing storage and minimizing subsurface environmental risk. The study also gives preliminary consideration to the effectiveness that monitoring strategy may play in providing useful information to inform reservoir management decisions for risk reduction. Two types of monitoring were considered: 1) pressure build-up or pressure transient; and 2) potential leakage detection from a CO 2 mass or plume. Four hypothetical legacy wells, two plugged and two abandoned, were placed in the model domain. Monitoring along these wells was measured over time in individual stacked reservoir formations and shale formations to support risk mitigation decisions, especially operational decisions that assisted in risk reduction. These simulations will serve as the basis for a series of GCS leakage risk forecasts that are to be developed using NRAP’s Open-IAM, and demonstration of a simple decision support workflow for comparative assessment of mitigation alternatives based on results of those system model forecasts. This risk assessment and decision support study is forthcoming.

54 ENVIRONMENTAL SCIENCES↗

Direct Air Capture Using Aqueous Amino Acid Solvents in a Crossflow Absorber

Carbon dioxide (CO 2 ) is the most abundant of all greenhouse gases (GHGs). CO 2 levels in the atmosphere are 50% higher than in the preindustrial era, trapping heat. CO 2 removal from the atmosphere by direct air capture (DAC) is needed to achieve the internationally agreed global temperature goals. The most common CO 2 capture technology is absorption by aminebased solvents in packed columns. Amino acid solutions have recently gained attention due to their advantages over traditional amine solvents. To be implemented effectively, DAC industrial processes need to handle large airflow rates in separation absorbers. The large air and solvent flow rates preclude the use of countercurrent columns due to high-pressure drops and the occurrence of flooding. Crossflow air−liquid absorbers are used to handle large air and liquid volumes due to their lower-pressure drop. The objective of this work is to study the influence of crossflow absorber geometric parameters and operating conditions on product formation and process efficiency. An already derived theoretical model for countercurrent absorbers has been modified to simulate the operation of a crossflow DAC absorber. The predictive model was implemented into a computer code that was used to study the efficiency of the processes as geometric equipment dimensions and operating parameters vary. Practical suggestions are made to design more efficient DAC processes.

Absorption↗

Total Cost of Ownership Reduction Using Passive Pre-Chamber Ignition in Natural Gas Engines

Spark plug durability is a factor affecting the total cost of ownership (TCO) of spark-ignited natural gas engines, with some heavy-duty platforms requiring plug replacement after only 750 hours of operation. The high ignition energy demand under lean or diluted conditions accelerates electrode wear, shortening plug life and increasing maintenance frequency. This work evaluates passive pre-chamber (PC) ignition operating at lowered spark energies as a strategy to reduce spark energy requirements and extend plug durability, thereby lowering TCO. Experiments were conducted on a medium-duty Cummins 6.7L ISB engine at 1600 RPM and 50% load under varying exhaust gas recirculation (EGR) dilution levels (0–40%). Two passive pre-chambers with 1.1 mm and 1.6 mm nozzle diameters were compared with conventional spark ignition (SI). SI was operated with a fixed coil dwell of 4 ms (~90 mJ), while the PC configuration was tested across 2–4 ms dwell times (~30–90 mJ). Cylinder pressure analysis revealed that PC ignition sustained stable combustion at significantly lower spark energies than SI, with improved combustion stability at ~30 mJ compared with SI at ~90 mJ. The PC system also extended the dilution tolerance beyond that achievable with SI, while delivering up to ~2% higher indicated thermal efficiency and reducing the COV by nearly 90% at 30% EGR. A TCO analysis was conducted to assess the economic benefit of adopting a passive PC system operating at reduced spark energies compared to SI. It was found that adopting a passive PC system could reduce TCO by approximately $11,000 per engine over a five-year operational period, primarily due to fuel savings, extended spark plug life, and reduced maintenance frequency. These projections were weighed against the additional hardware cost of the pre-chamber, yielding a rapid estimated return on investment of ~300 operating hours. Therefore, this work motivates continued research and development of passive PC technology and its commercial adoption in natural gas engines used in transportation applications.

Dhotre, Akash [University of Minnesota]↗

Leveraging operational information from wastewater injection wells to evaluate CO 2 injection performance for carbon storage applications in the Appalachian Basin

Abstract Geologic parameters, geophysical logging, injection testing, and operational metrics from wastewater injection wells were integrated to develop a preliminary design of a carbon storage facility in the Appalachian Basin. A scattered group of 10–20 commercial wastewater injection wells dispose off produced water from oil and gas wells in the region, utilizing a sequence of stacked deep saline formations for injection zones. These wastewater injection wells provide practical benchmarks for understanding the feasibility of carbon dioxide (CO 2 ) storage. Geologic models were developed based on characterization data from the wastewater injection wells. Reservoir simulations were calibrated according to injection testing and operational data from the wastewater injection wells. Long‐term operational data on injection flow rates and pressures measured in the wastewater injection wells were especially useful to evaluate the performance of carbon storage applications. The simulations were used to estimate injection pressures, radius of CO 2 saturation, and pressure response for industrial scale CO 2 storage applications. Results were also used to provide a design basis in terms of number of injection wells, well spacing, area of review, injection system components, monitoring plan, and CO 2 pipeline distribution system. The analysis demonstrates that there is sufficient injectivity in the deep saline formations in the west‐central Appalachian Basin to store commercial volumes of anthropogenic CO 2 . The geologic system appears suitable for supporting CO 2 injection rates of 0.5–1.0 million metric tons per year at injection pressures below formation fracture pressure in a single well. The long‐term operational data of wastewater injection wells within the study area suggested a lower permeability‐thickness values than indicated by initial reservoir tests. A workflow for developing realistic permeability values for input into reservoir simulations is presented. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd.

Valluri, Manoj↗

Analysys of the performance a PEM-type electrolyzer in variable energy supply conditions

Here in this article, the main variables related to the performance of a proton exchange membrane-type electrolyzer are analyzed along with the risk of explosion for different operating conditions, notably when the electrolyzer works with a variable solar energy power supply and at high pressure. A novel mathematical model was developed that considers all mass transport phenomena through the membrane electrode assembly (MEA) for water, hydrogen, and oxygen, as well as the water evaporation in the anode and cathode channels. The main findings of this work are that for a solar energy supply operating at high pressure, the electrolyzer cannot function safely throughout the day, since in the hours when solar irradiation is lower, low current densities favor high hydrogen concentrations at the anode. Finally, it was found that greater thicknesses of the membrane increased the explosion risk due to the increase in the MEA temperature and therefore the hydrogen solubility.

08 HYDROGEN↗

Tar Formation and Mitigation in Pressurized Biomass and Cofired Gasification

Biomass gasification with CO2 capture has the potential to provide carbon-negative heat, power, and feedstock for sustainable hydrocarbon fuels. In a pressurized gasifier, precombustion solvent systems can capture CO2 with less energy than needed for amine-based postcombustion CO2 capture, and pressurized syngas is generally more suitable for fuel synthesis. Although precombustion capture has been used for many decades in large-scale fossil-based plants, it has not been well-demonstrated in smaller-scale biomass gasification. Precombustion solvents and product streams could be particularly impacted by tar and other organic compounds that tend to form in high concentrations during low-temperature biomass gasification. A pressurized pilot-scale gasifier was used to examine tar formation and fate when using CO2 capture with various blends of biomass and coal. The syngas was fully conditioned to remove particulate matter; capture sulfur; adjust syngas chemistry using water-gas shift; quench out moisture and condensable organics; and capture CO2. Tar concentrations were measured in the raw syngas, the product gas, and in the liquid streams over the course of several weeks. The gasifier was operated both as a high-pressure oxygen-blown system to mimic large-scale centralized gasification and at lower pressures under air-blown conditions to mimic a more likely small-scale system. A second high-temperature stage with oxidant injection was used to crack tars. The overall results showed how gasifier and CO2 capture performance change as fuel is blended between coal to biomass and what the fate of tar is through a precombustion CO2 capture system.

Strege, Josh [University of North Dakota EERC] (OR↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of Common Thermoplastic Polymers in High-Pressure Cycling Hydrogen Under Ambient and Cold Environments as Applicable to the Hydrogen Infrastructure

Thermoplastic polymers are required to perform unfailingly under stringent conditions of changing pressures (35 MPa to 70 MPa) and temperatures (-40°C to +85°C) in storage and fueling operations. Although diffusivity in glassy polymers appear to be an order of magnitude lower than elastomers, polymer microstructural attributes such as degree of crystallinity and presence of polar and non-polar groups on the main chain with and without branching can play a substantial role in influencing their behaviors in hydrogen environments. In the work described here, the effect of high-pressure hydrogen cycling on PEEK, PTFE, PA11, HDPE, POM (and different commercial grades of these polymers) under ambient and cold (-40°C) conditions is addressed. Ex-situ characterization for polymer changes included density measurements for impact of hydrogen retention, hardness changes using nanoindentation, storage modulus and glass transition changes using dynamic mechanical and thermal analysis (DMTA), degree of crystallization with Differential Scanning Calorimetry (DSC) and tensile testing following ASTM D412. In other evaluations, solid-state nuclear magnetic resonance (NMR), attenuated total reflectance Fourier transform infra-red spectroscopy (ATRFTIR), X-ray diffraction (XRD), and X-ray CT results are presented. The overall impact of these evaluations is to establish a technical basis for the behaviors of common thermoplastics in cycling hydrogen environments under ambient and cold temperatures while establishing the relationship between polymer structure-based properties and hydrogen transport effects.

Menon, Nalini C.↗

Validation of prediction capability of operating space for plasma initiation in MAST-U

DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗