Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Scientific Applications and Promise of Cryogenic Detector Arrays

During the past year, the first results from a new generation of instruments based on kilopixel-scale arrays of cryogenic detectors have been released. I will review the history of low temperature detector arrays which has enabled this development, the science which has driven this rapid progress, describe the instruments now in operation and their initial scientific results, and speculate on the developments we may see in the next decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly and Integration Process of the High-Density Detector Array Readout Modules for the Simons Observatory

The Simons Observatory will measure the cosmic microwave background tempera-ture and polarization using a suite of new telescopes in the Atacama Desert in Chile. The Simons Observatory will use dichroic transition edge sensor (TES) bolometer arrays spanning six frequency bands from 27 to 280 GHz. The Simons Observa-tory will pioneer the use of a densely packed multiplexing architecture based on the microwave SQUID multiplexer ( 𝜇mux), housing ∼2000 microwave resonators, each coupled to a TES. The Simons Observatory aims to multiplex each array of ∼2000 detectors with a single pair of coaxial cables and requires a multiplexing factor of ∼1000 . The Simons Observatory cryogenic readout system is called the universal microwave multiplexing module (UMM). The UMM couples to both horn and lenslet-coupled detector arrays and is integrated into the universal focal-plane module (UFM) after being independently characterized. We present processes we have developed for highly repeatable and automated integration methods of UMMs, which will be needed for the production of the 49 UFMs required for the first stage of the Simons Observatory.

CMB↗

A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512

Purpose: Silicon diode arrays are commonly implemented in radiation therapy quality assurance applications as they have a number of advantages including: real time operation (compared to the film) and high spatial resolution, large dynamic range and small size (compared to ionizing chambers). Most diode arrays have detector pitch that is too coarse for routine use in small field applications. The goal of this work is to characterize the two-dimensional monolithic silicon diode array named “MagicPlate-512” (MP512) designed for QA in stereotactic body radiation therapy (SBRT) and stereotactic radio surgery (SRS). Methods: MP512 is a silicon monolithic detector manufactured on ap-type substrate. An array contains of 512 pixels with size 0.5 × 0.5 mm{sup 2} and pitch 2 mm with an overall dimension of 52 × 52 mm{sup 2}. The MP512 monolithic detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of raisin to preserve the silicon detector from moisture and chemical contamination and to protect the bonding wires. Characterization of the silicon monolithic diode array response was performed, and included pixels response uniformity, dose linearity, percent depth dose, output factor, and beam profiling for beam sizes relevant to SBRT and SRS and depth dose response in comparison with ionization chamber. Results: MP512 shows a good dose linearity (R{sup 2} = 0.998) and repeatability within 0.2%. The measured depth dose response for field size of 10 × 10 cm{sup 2} agreed to within 1.3%, when compared to a CC13 ionization chamber for depths in PMMA up to 30 cm. The output factor of a 6 MV Varian 2100EX medical linac beam measured by MP512 at the isocenter agrees to within 2% when compared to PTW diamond, Scanditronix point EDD-2 diode and MOSkin detectors for field sizes down to 1 × 1 cm{sup 2}. An over response of 4% was observed for square beam size smaller than 1 cm when compared to EBT3 films, while the beam profiles (FWHM) of MP512 match to within 2% the data measured by radiochromic film. Conclusions: The response of the 2D detector array, MP512, has been evaluated. The properties of the array demonstrated suitability for use as in phantom dosimeter for QA in SRS and SBRT. Although MP512 matches film measurements down to 1 × 1 cm{sup 2} well, it showed a discrepancy of 4% in the determination of output factors of beams smaller than 0.5 × 0.5 cm{sup 2} due to the field perturbation generated by the large amount of silicon surrounding the central diode. MP512 is highly capable of measuring beam size (FWHM) and has a discrepancy of less than 1.3% when compared to EBT3 film. A reduction in the detector pitch to less than 2 mm would improve the penumbra reconstruction accuracy at the cost readout electronics complexity.

07 ISOTOPE AND RADIATION SOURCES↗

Performance characteristics of multi-anode microchannel array detector systems

The multi-anode microchannel arrays (MAMAs) are state-of-the-art, pulse-counting, photoelectric array detectors designed specifically for use in space astrophysics instruments. The present paper provides a description of recent progress related to the development of ultraviolet and visible-light versions of the MAMA detectors, taking into account a comparison of the operating characteristics of these devices with those of photoconductive array detectors, such as the CCDs. Attention is given to MAMA detector system design parameters, the operating characteristics of MAMAs and CCDs, MAMA performance characteristics, and future developments.

Timothy, J. G.↗

Characterization of a third-generation Faraday-strip array detector coupled to a Mattauch-Herzog geometry mass spectrograph with a dc-glow discharge ionization source

A third-generation Faraday-strip array detector has been coupled to a Mattauch-Herzog mass spectrometer and dc glow-discharge ionization source. This combination offers simultaneous determination of multiple elements directly from solid samples and provides superior resolving power and improved limits of detection over previous generations of array detectors. With the thirdgeneration detector array, resolving power is limited only by the mass spectrometer and not by the array. Because of this enhanced resolution, limits of detection, especially for higher mass-to-charge ratios, were improved. Isotope-ratio precision was found to be 0.07% RSD on average and quantitative response was linear over 5 orders of magnitude.

47 OTHER INSTRUMENTATION↗

Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory

The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above $3\times 10^{18}$ eV, for all zenith angles between 0$^\circ$ and 60$^\circ$, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

Advanced ACTPol (AdvACT)↗

Coherent summation of spatially distorted laser Doppler signals by using a two-dimensional heterodyne detector array

Phase-sensitive coherent summation of individual heterodyne detector array signals was demonstrated for the enhanced detection of spatially distorted laser Doppler returns. With the use of a 2 x 2 heterodyne detector array, the phase and amplitude of a time-varying speckle pattern was detected, and the signal-to-noise ratio of the Doppler shift estimate was shown to be improved by a factor of 2, depending on the extent of spatial coherence loss. These results are shown to agree with a first-order analysis and indicate the advantage of coherent summation for both short-range laser Doppler velocimetry and long-range atmospheric coherent lidar.

Chan, Kin P.↗

Coherent summation of spatially distorted Doppler lidar signals using a two-dimensional heterodyne detector array

We have investigated the improvement in the signal-to-noise ratio for a coherent Doppler lidar through the use of a multi-element heterodyne detector array. Such an array enables the spatial summation of atmospheric refractive turbulence induced speckles, and time varying target speckles. Our recent experiments have shown that the non-coherent summation of the lidar signals from a heterodyne detector array can enhance the heterodyne mixing efficiency and thus the signal-to-noise ratio. In this paper, we expand this work to include the coherent summation of array signals. The digitized heterodyne signals were stored in a personal computer. Fast Fourier transforms were performed on both the non-coherent and coherent summations of the detector array signals. It was found that the coherent summation greatly enhanced the accuracy in the Doppler frequency estimate. A theoretical analysis was performed and indicated good agreement with experimental results. We have also applied these results to the more general lidar applications including atmospheric wind sensing, and have found that in most lidar applications the Doppler frequency estimate is increased through the use of the heterodyne detector array.

Chan, Kin Pui↗

Versatile, reprogrammable area pixel array detector for time-resolved synchrotron x-ray applications

The final technical report for DOE grant DE-SC0004079 is presented. The goal of the grant was to perform research, development and application of novel imaging x-ray detectors so as to effectively utilize the high intensity and brightness of the national synchrotron radiation facilities to enable previously unfeasible time-resolved x-ray research. The report summarizes the development of the resultant imaging x-ray detectors. Two types of detector platforms were developed: The first is a detector platform (called a Mixed-Mode Pixel Array Detector, or MM-PAD) that can image continuously at over a thousand images per second while maintaining high efficiency for wide dynamic range signals ranging from 1 to hundreds of millions of x-rays per pixel per image. Research on an even higher dynamic range variant is also described. The second detector platform (called the Keck Pixel Array Detector) is capable of acquiring a burst of x-ray images at a rate of millions of images per second.

47 OTHER INSTRUMENTATION↗

High definition large area mapping of geological samples using a Maia detector array in the Nuclear Microprobe

A Maia detector array has been utilized and installed on the CSIRO-MARC Nuclear Microprobe. Maia uses an annular array of 384 silicon detectors to provide a solid-angle of 1.3 sr to improve the collection of X-rays induced by Particle Induced X-ray Emission (PIXE) using a micron focussed MeV proton beam. It features event-by-event data acquisition with dead-time correction and pileup rejection and a total count-rate capacity above 10 M/s, versatile stage and beam scanning modes (coupled to the DAQ-36 system described previously) to cater for a variety of sample configuration and experimental needs, precise measurement of transit time and integration of beam fluence per pixel, and spectral deconvolution of event data in real-time using the Dynamic Analysis method to provide element images during data collection. In this work we demonstrate the system on thin sections made from geological samples extracted from active seafloor hydrothermal vents in the PACMANUS hydrothermal field in Papua New Guinea.

36 MATERIALS SCIENCE↗

Soft x-ray intensity profile measurements of electron cyclotron heated plasmas using semiconductor detector arrays in GAMMA 10 tandem mirror

Temporally and spatially resolved soft x-ray analyses of electron cyclotron heated plasmas are carried out by using semiconductor detector arrays in the GAMMA 10 tandem mirror. The detector array has 16-channel for the measurements of plasma x-ray profiles so as to make x-ray tomographic reconstructions. The characteristics of the detector array make it possible to obtain spatially resolved plasma electron temperatures down to a few tens eV and investigate various magnetohydrodynamic activities. High power electron cyclotron heating experiment for the central-cell region in GAMMA 10 has been started in order to reduce the electron drag by increasing the electron temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector arrays for photometric measurements at soft X-ray, ultraviolet and visible wavelengths

The construction and modes of operation of the Multi-Anode Microchannel Array (MAMA) detectors are described, and the designs of spectrometers utilizing them are outlined. MAMA consists of a curved microchannel array plate, an opaque photocathode (peak quantum efficiency of 19% at 1216 A), and a multi-anode (either discrete- or coincidence-anode) readout array. Designed for use in instruments on spaceborne telescopes, MAMA can be operated in a windowless configuration in extreme-ultraviolet and soft X-ray wavelengths, or in a sealed configuration at UV and visible wavelengths. Advantages of MAMA include low applied potential (less than 3.0 kV), high gain (greater than 10 to the 6th electrons/pulse), low sensitivity to high-energy charged particles, and immunity to external magnetic fields of less than 500 Gauss

Timothy, J. G.↗

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.↗

Technique for mounting pyroelectric detector arrays

Technique is developed at Langley Research Center for mounting pyroelectric detector arrays on silicon integrated circuits. Procedure incorporates normal silicon integrated-circuit technology to form quasi-free mounts for detector arrays. Advantages of technique include lower cost, better image registration, and improved reliability.

Breckenridge, R. A.↗

Multianode microchannel array detectors for Space Shuttle imaging applications

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric, photoncounting array detectors that have been developed and qualified specifically for use in space. MAMA detectors with formats as large as 256 x 1024 pixels are now in use or under construction for a variety of imaging and tracking applications. These photo-emissive detectors can be operated in a windowless configuration at extreme ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. The construction and modes-of-operation of the MAMA detectors are briefly described and the scientific objectives of a number of sounding rocket and Space Shuttle instruments utilizing these detectors are outlined. Performance characteristics of the MAMA detectors that are of fundamental importance for operation in the Space Shuttle environment are described and compared with those of the photo-conductive array detectors such as the CCDs and CIDs.

Timothy, J. G.↗

A stochastic constrained optimization technique and its application to detector array processing.

A stochastic projected gradient algorithm is proposed which can be used for finding a constrained optimum point for a concave or convex objective function subject to nonlinear constraints which form a connected region even when only a noisy estimate of the objective function is available. For a constraint described by a single linear equation, convergence to the constrained optimum value is proved, and the rate of convergence of the algorithm to the constrained optimum value is determined. The algorithm is applied to the nonlinear problem of obtaining automatically an array of detectors which forms a beam in a desired direction in space in the presence of interfering noise so as to maximize the SNR subject to a constraint on the super-gain ratio.

Winkler, L. P.↗

SU-E-T-644: Evaluation of Angular Dependence Correction for 2D Array Detector Using for Quality Assurance of Volumetric Modulated Arc Therapy

Purpose: To evaluate the angular dependence correction for Matrix Evolution 2D array detector in quality assurance of volumetric modulated arc therapy(VMAT). Methods: Total ten patients comprising of different sites were planned for VMAT and taken for the study. Each plan was exposed on Matrix Evolution 2D array detector with Omnipro IMRT software based on the following three different methods using 6MV photon beams from Elekta Synergy linear accelerator. First method, VMAT plan was delivered on Matrix Evolution detector as it gantry mounted with dedicated holder with build-up of 2.3cm. Second, the VMAT plan was delivered with the static gantry angle on to the table mounted setup. Third, the VMAT plan was delivered with actual gantry angle on Matrix Evolution detector fixed in Multicube phantom with gantry angle sensor and angular dependence correction were applied to quantify the plan quality. For all these methods, the corresponding QA plans were generated in TPS and the dose verification was done for both point and 2D fluence analysis with pass criteria of 3% dose difference and 3mm distance to agreement. Results: The measured point dose variation for the first method was observed as 1.58±0.6% of mean and SD with TPS calculated. For second and third method, the mean and standard deviation(SD) was observed as 1.67±0.7% and 1.85±0.8% respectively. The 2D fluence analysis of measured and TPS calculated has the mean and SD of 97.9±1.1%, 97.88±1.2% and 97.55±1.3% for first, second and third methods respectively. The calculated two-tailed Pvalue for point dose and 2D fluence analysis shows the insignificance with values of 0.9316 and 0.9015 respectively, among the different methods of QA. Conclusion: The qualitative evaluation of angular dependence correction for Matrix Evolution 2D array detector shows its competency in accuracy of quality assurance measurement of composite dose distribution of volumetric modulated arc therapy.

07 ISOTOPE AND RADIATION SOURCES↗