Search NASA⌕ Search

SEARCH · Search NASA

Results for “astronomical detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dual-Resonator Kinetic-Inductance Detector for Distinction between Signal and 1/ƒ Frequency Noise

Astronomical kinetic inductance detectors (KIDs), similar to quantum information devices, experience performance-limiting noise from materials. In particular, 1/ƒ (frequency) noise arises from two-level system defects (TLSs) in the circuit dielectrics and material interfaces and can be a dominant noise mechanism. Here, we present a dual-resonator KID (DuRKID), which is designed for improved noise-equivalent power relative to standard 1/ƒ -noise-limited KIDs. In this study we present the DuRKID schematic, a fabricated example, our first measurement results, a theoretical model including 1/ƒ noise, and a system-noise model containing additional noise sources. The circuit consists of two superconducting resonators sharing an electrical capacitance bridge of four capacitors, each of which hosts TLSs. The device is intended to operate using hybridization of the modes, which causes TLSs to either couple to one mode or the other, depending upon which capacitor they reside in. In contrast, the signal will affect a resonator inductance and, due to mode hybridization, this causes correlated frequency changes in both modes. Therefore, one can better distinguish the photon signal from the TLS frequency noise. To achieve hybridization, a TiN inductor is current biased to allow tuning of one bare-resonator mode into degeneracy with the other. Measurements show that the resonator modes hybridize as expected. The inter-resonator coupling and unintentional coupling of the two resonators to transmission lines are also characterized in measurements. A quantum information-science model allows device-parameter extraction from experimental data and a 1/ƒ noise analysis with uncorrelated noise. A system-noise analysis of the DuRKID, with comparisons to standard KIDs, is performed with generation-recombination noise and amplifier noise. The study reveals that the DuRKID can exhibit a large performance advantage over TLS-limited KID detectors.

N Forouzani↗

H2RG Detector Characterization for RIMAS and Instrument Efficiencies

The Rapid infrared IMAger-Spectrometer (RIMAS) is a near-infrared (NIR) imager and spectrometer that will quickly follow up gamma-ray burst afterglows on the 4.3-meter Discovery Channel Telescope (DCT). RIMAS has two optical arms which allows simultaneous coverage over two bandpasses (YJ and HK) in either imaging or spectroscopy mode. RIMAS utilizes two Teledyne HgCdTe H2RG detectors controlled by Astronomical Research Cameras, Inc. (ARC/Leach) drivers. We report the laboratory characterization of RIMAS's detectors: conversion gain, read noise, linearity, saturation, dynamic range, and dark current. We also present RIMAS's instrument efficiency from atmospheric transmission models and optics data (both telescope and instrument) in all three observing modes.

Toy, Vicki L.↗

Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space

Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.

Astronomical detectors↗

Ccds: Their Cause and Cure

Charge coupled devices (CCDs) have opened new horizons in the optical astronomy. Most of the presently existing astronomical CCD systems are oriented and designed primarily for work on faint objects. The use of CCDs for high precision work on bright objects remains to be explored. Issues and problems specific to (CCDs) are covered in detail. The important structural characteristics of CCDs are that they are integrating, self scanned, photon counting (one selection for each detected photon), solid state devices. The typical physical sizes are of the order of 1 - 3 cm, and typical raster formats of 500x500 pixels (TI), 320x512 (RCA), 385x576 (GEC), 800x800 (TI), and 1500x1500 (GEC) should be available soon. Typical (and optimal) operating temperatures are around -100 C, with liquid N2 as the most common coolant. Some CCDs are physically warped. This causes focus variations across the surface, which amount to a spatially variable PSF. Other relevant properties of CCDs as detectors and a comparison with some other astronomical detectors are given.

Djorgovski, S.↗

Infrared Astronomical Satellite (IRAS) superfluid helium tank temperature control

The infrared detectors on the Infrared Astronomical Satellite (IRAS), which was placed into a polar orbit in January 1983, are cooled to a temperature of less than 3 K by thermal coupling to the main cryogenic tank (MCT) containing superfluid helium. A porous plug built into the vent line entrance acts as a superfluid helium liquid/vapor separator in zero gravity. A description of the IRAS MCT flight porous plug is presented, and tests of the plug in situ are discussed, taking into account submerged plug tests, a restart test, and a cold vapor flow test. Aspects of flow rate determination in the case of an unavailability of flight flow rate data are also considered.

Petrac, D.↗

Integrated detector array technology for infrared astronomy

The status of laboratory and telescope tests of integrated infrared detector array technology for astronomical applications is described. The devices tested represent a number of extrinsic and intrinsic detector materials and various multiplexer designs. Infrared arrays have now been used in successful astronomical applications. These have shown that device sensitivities can be comparable to those of discrete detector systems and excellent astronomical imagery can be produced.

Mccreight, c. R.↗

CALISTO: A Cryogenic Far-Infrared/Submillimeter Observatory

We present a design for a cryogenically cooled large aperture telescope for far-infrared astronomy in the wavelength range 30 micrometers to 300 micrometers. The Cryogenic Aperture Large Infrared Space Telescope Observatory, or CALISTO, is based on an off-axis Gregorian telescope having a 4 m by 6 m primary reflector. This can be launched using an Atlas V 511, with the only optical deployment required being a simple hinged rotation of the secondary reflector. The off-axis design, which includes a cold stop, offers exceptionally good performance in terms of high efficiency and minimum coupling of radiation incident from angles far off the direction of maximum response. This means that strong astronomical sources, such as the Milky Way and zodiacal dust in the plane of the solar system, add very little to the background. The entire optical system is cooled to 4 K to make its emission less than even this low level of astronomical emission. Assuming that detector technology can be improved to the point where detector noise is less than that of the astronomical background, we anticipate unprecedented low values of system noise equivalent power, in the vicinity of 10(exp -19) WHz(exp -0.5), through CALISTO's operating range. This will enable a variety of new astronomical investigations ranging from studies of objects in the outer solar system to tracing the evolution of galaxies in the universe throughout cosmic time.

Cryogenic Aperture Large Infrared Space Telescope ↗

Position-sensitive CdTe detector using improved crystal growth method

The feasibility of developing a position-sensitive CdTe detector array for astronomical observations in the hard X-ray, soft gamma ray region is demonstrated. In principle, it was possible to improve the resolution capability for imaging measurements in this region by orders of magnitude over what is now possible through the use of CdTe detector arrays. The objective was to show that CdTe crystals of the quality, size and uniformity required for this application can be obtained with a new high pressure growth technique. The approach was to fabricate, characterize and analyze a 100 element square array and several single-element detectors using crystals from the new growth process. Results show that detectors fabricated from transversely sliced, 7 cm diameter wafers of CdTe exhibit efficient counting capability and a high degree of uniformity over their entire areas. A 100 element square array of 1 sq mm detectors was fabricated and operated.

Source record↗

The Lick Observatory image-dissector scanner.

A scanner that uses an image dissector to scan the output screen of an image tube has proven to be a sensitive and linear detector for faint astronomical spectra. The image-tube phosphor screen acts as a short-term storage element and allows the system to approach the performance of an ideal multichannel photon counter. Pulses resulting from individual photons, emitted from the output phosphor and detected by the image dissector, trigger an amplifier-discriminator and are counted in a 24-bit, 4096-word circulating memory. Aspects of system performance are discussed, giving attention to linearity, dynamic range, sensitivity, stability, and scattered light properties.

Robinson, L. B.↗

Experience with the UKIRT InSb array camera

The cryogenic infrared camera, IRCAM, has been operating routinely on the 3.8 m UK Infrared Telescope on Mauna Kea, Hawaii for over two years. The camera, which uses a 62x58 element Indium Antimonide array from Santa Barbara Research Center, was designed and built at the Royal Observatory, Edinburgh which operates UKIRT on behalf of the UK Science and Engineering Research Council. Over the past two years at least 60% of the available time on UKIRT has been allocated for IRCAM observations. Described here are some of the properties of this instrument and its detector which influence astronomical performance. Observational techniques and the power of IR arrays with some recent astronomical results are discussed.

Mclean, Ian S.↗

Atmospheric Trace Gas Abundances and Stable Isotope Ratios via IR-LIF

We propose to develop new technologies with support provided by PIDDP that will enable the in situ measurements of abundances and stable isotope ratios in important radiatively and biogenically active gases such as carbon dioxide, carbon monoxide, water, methane, nitrous oxide, and hydrogen sulfide to very high precision (0.1 per mil or better for the isotopic ratios, for example). Such measurements, impossible at present, could provide pivotal new constraints on the global (bio)geochemical budgets of these critical species, and could also be used to examine the dynamics of atmospheric transport on Mars, Titan, and other solar system bodies. We believe the combination of solid state light sources with imaging of the IR laser induced fluorescence (IR-LIF) via newly available detector arrays will make such in situ measurements possible for the first time. Even under ambient terrestrial conditions, the LIF yield from vibrational excitation of species such as water and carbon dioxide should produce emission measures well in excess of ten billion photons/sec from samples volumes of order 1 c.c. These count rates can, in principle, yield detection limits into the sub-ppt range that are required for the in situ isotopic study of atmospheric trace gases. While promising, such technologies are relatively immature, but developing rapidly, and there are a great many uncertainties regarding their applicability to in situ IR-LIF planetary studies. We therefore feel PIDDP support will be critical to developing these new tools, and propose a three-year program to combine microchip near-IR lasers with low background detection axes and state-of-the-art HgCdTe detectors developed for astronomical spectroscopy to investigate the sensitivity of IR-LIF under realistic planetary conditions, to optimize the optical pumping and filtering schemes for important species, and to apply the spectrometer to the non-destructive measurement of stable isotopes in a variety of test samples. These studies form the necessary precursors to the development of compact, lightweight stable isotope/trace gas sensors for future planetary missions.

Blake, Geoffrey A.↗

Large Aperture Systems: 2000-2004

This custom bibliography from the NASA Scientific and Technical Information Program lists a sampling of records found in the NASA Aeronautics and Space Database. The scope of this topic includes technologies for next generation astronomical telescopes and detectors. This area of focus is one of the enabling technologies as defined by NASA s Report of the President s Commission on Implementation of United States Space Exploration Policy, published in June 2004.

Source record↗

Electromagnetic Properties of Filled, Pixellated Arrays

Filled arrays of bolometers are currently being employed for use in astronomy from the far-infrared through millimeter parts of the electromagnetic spectrum. Because of the large range of wavelengths for which this is applicable, the number of modes supported by a bolometric pixel will vary according to specific application. Withington et al. (2003) have built a formalism for treating the electromagnetic properties of such bolometers by propagating the second order statistical properties of the radiation through a canonical optical system. In this work, we use this formalism to construct beam pattern images of square pixels for various ratios of p/lambda where p is the pixel size and lambda is the wavelength. In the low mode limit, the diffraction effects cause the beam pattern to be circular with a quadrupole dependence of Stokes Q and U. High mode cases approach the geometric limit. The polarization in these cases can be seen to trace the pixel edges. The effective size of the beam has a direct impact on the inter-pixel coupling and sets the number of independent detectors in an astronomical focal plane. This technique illustrates and quantifies the relationship between pixel size and angular resolution limits for a given wavelength and telescope. This is especially true in the limit of low p/lambda. In this case, the diffraction due to pixelization is non-negligible for the calculation of the overall angular resolution of the telescope. In addition, for instruments that are polarization sensitive, this method also provides a quantitative method for determining the contribution of the instrument to the measured polarization.

Chuss, David T.↗

Electron Velocity Moments in the Solar Wind. I. Calibration of the Wind 3DP EESA Low Detector

Calibrated measurements of electron velocity distribution functions (VDFs) are necessary to characterize fluid and kinetic processes in weakly collisional and nearly collisionless plasmas such as the solar wind. Therefore, we analyzed 3,996,051 electron VDFs observed by the Wind 3DP thermal electron detector near 1 astronomical unit (au) between January 1, 2005 and November 25, 2017. The data were calibrated for each electron VDF to produce accurate velocity moments in the solar wind. This is the first full solar cycle coverage electron velocity moment dataset in the near-Earth solar wind. Herein (Paper I) we discuss the calibration process/algorithms and the velocity moment constraints, uncertainties, and resulting public dataset. In the second paper (Paper II), we statistically analyze the electron velocity moment dataset.

plasmas↗

A Far Infrared Echelle Spectrometer for the Kuiper Airborne Observatory

A liquid-helium-cooled grating spectrometer (CGS) is being developed as a facility instrument for the Kuiper Airborne Observatory (KAO), primarily to study for infrared lines originating in the interstellar medium. A maximum resolving power of approximately 6000 is achieved by means of a 45 cm long Echelle grating and is optically capable of operating in the spectral range from 25 to 300 microns. An array of detectors is used to simultaneously measure a line and the adjacent continuum from astronomical sources. Currently six detectors allow measurements in the 30 to 120 micron spectral band. The instrument, its operation, and its performance are described.

Erickson, E. F.↗

Ge:Ga and Ge:Be photoconductive detectors for far infrared astronomy from a space platform

The paper describes some of the development work on gallium-doped germanium (Ge:Ga) and beryllium-doped germanium (Ge:Be) photoconductive detectors for use in far-infrared astronomical observations from a space platform such as IRAS. The paper is concerned primarily with detector performance and is divided into two major parts. The first presents the operating principles of this type of detector, while the second presents measured performance data under low-background flux conditions. It is shown that high sensitivity can be obtained from Ge:Ga and Ge:Be detectors under low-background and low-temperature conditions of operation. These detectors are useful for astronomical observations in the far-infrared over the wavelength range 30-120 microns. Major conclusions of the research work done so far are mentioned, including that detectors cut from the same crystal show reasonably good reproducibility of operating characteristics.

Bratt, P. R.↗

A position sensitive phoswich hard X-ray detector system

A prototype position sensitive phoswich hard X-ray detector, designed for eventual astronomical usage, was tested in the laboratory. The scintillation crystal geometry was designed on the basis of a Monte Carlo simulation of the internal optics and includes a 3mm thick NaI(T1) primary X-ray detector which is actively shielded by a 20 mm thick CsI(T1) scintillation crystal. This phoswich arrangement is viewed by a number two inch photomultipliers. Measured values of the positional and spectral resolution of incident X-ray photons are compared with calculation.

Dean, A. J.↗

Low-background detector arrays for infrared astronomy

The status of a program which develops and characterizes integrated infrared (IR) detector array technology for space astronomical applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, coupled to silicon readout electronics. Low-background laboratory test results include measurements of responsivity, noise, dark current, temporal response, and the effects of gamma-radiation. In addition, successful astronomical imagery has been obtained on some arrays from this program. These two aspects of the development combine to demonstrate the strong potential for integrated array technology for IR space astronomy.

Mccreight, C. R.↗