Search NASA⌕ Search

SEARCH · Search NASA

Results for “atom interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A continuous cold atomic beam interferometer

We demonstrate an atom interferometer that uses a laser-cooled continuous beam of {sup 87}Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm{sup 2} at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10{sup −5} rad/s/√(Hz) for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Truncated nonlinear interferometer-based atomic force microscopes

A truncated non-linear interferometer-based atomic force microscope (AFM) includes an input port and a non-linear amplifier that renders a probe beam and a conjugate beam. The AFM includes local oscillators having a relationship with the probe beam and the conjugate beam. The displacement of the AFM's cantilever is transduced by the probe beam, and/or the conjugate beam or their respective local oscillators. The AFM's phase-sensitive detectors detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. The detected phase modulation corresponds to the change in phase. The AFM's circuitry measures phase signals that are indicative of the cantilever displacement. The resulting measurement signals exhibit a quantum noise reduction in either the intensity difference or phase sum quadrature.

Pooser, Raphael C.↗

Ultralight dark matter detection with mechanical quantum sensors

Abstract We consider the use of quantum-limited mechanical force sensors to detect ultralight (sub-meV) dark matter (DM) candidates which are weakly coupled to the standard model. We show that mechanical sensors with masses around or below the milligram scale, operating around the standard quantum limit, would enable novel searches for DM with natural frequencies around the kHz scale. This would complement existing strategies based on torsion balances, atom interferometers, and atomic clock systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin-squeezed vector atomic magnetometry

Atomic magnetometers based on Zeeman shift measurement have the potential for high sensitivity and long-term stability. Like other atomic sensors, including atomic clocks and atom interferometers, the atomic magnetometer could, in principle, be augmented with spin squeezing for further sensitivity enhancement. However, existing atomic magnetometers are not compatible with spin squeezing because the atoms can hardly be in a pure quantum state during operation. Moreover, a natural challenge faced by an atomic magnetometer is the arbitrary direction of the magnetic field. In this paper, we propose a cold-atom-based magnetometer with spin squeezing that can measure both the magnitude and the direction of an arbitrary magnetic field. For experimentally accessible parameters, we show that the technique described above could potentially achieve a sensitivity nearly two orders of magnitude higher than that of the best existing magnetometers.

Li, Jinyang [Northwestern U.] (ORCID:0000000194328↗

Spin-squeezing-enhanced dual-species atom interferometric accelerometer employing large momentum transfer for precision test of the equivalence principle

Here, we theoretically investigate the feasibility of applying spin squeezing to a light pulse atom interferometer in the presence of large momentum transfer using off resonant Raman transitions, in order to enhance the sensitivity of accelerometry close to the Heisenberg limit. We also show how to implement this scheme in a dual-species atom interferometer for a precision test of the equivalence principle by measuring the Eötvös parameter, and to identify the spin squeezing protocol that is best suited for such an experiment. For a space borne platform in low Earth orbit, such a scheme may eventually enable the measurement of the Eötvös parameter with a sensitivity of the order of 10 -20 within 150 days when 10 5 atoms are employed in each cycle of the experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

Atom interferometry in space: Thermal management and magnetic shielding

Atom interferometry is an exciting tool to probe fundamental physics. It is considered especially apt to test the universality of free fall by using two different sorts of atoms. The increasing sensitivity required for this kind of experiment sets severe requirements on its environments, instrument control, and systematic effects. This can partially be mitigated by going to space as was proposed, for example, in the Spacetime Explorer and Quantum Equivalence Principle Space Test (STE-QUEST) mission. However, the requirements on the instrument are still very challenging. For example, the specifications of the STE-QUEST mission imply that the Feshbach coils of the atom interferometer are allowed to change their radius only by about 260 nm or 2.6 × 10{sup −4} % due to thermal expansion although they consume an average power of 22 W. Also Earth's magnetic field has to be suppressed by a factor of 10{sup 5}. We show in this article that with the right design such thermal and magnetic requirements can indeed be met and that these are not an impediment for the exciting physics possible with atom interferometers in space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Terrestrial Search for Dark Contents of the Vacuum, Such as Dark Energy, Using Atom Interferometry

We describe the theory and first experimental work on our concept for searching on earth for the presence of dark contents of the vacuum (DCV) using atom interferometry. Specifically, we have in mind any DCV that has not yet been detected on a laboratory scale, but which might manifest itself as dark energy on the cosmological scale. The experimental method uses two atom interferometers to cancel the effect of earth's gravity and diverse noise sources. It depends upon two assumptions: first, that the DCV possesses some space inhomogeneity in density, and second that it exerts a sufficiently strong nongravitational force on matter. The motion of the apparatus through the DCV should then lead to an irregular variation in the detected matter-wave phase shift. We discuss the nature of this signal and note the problem of distinguishing it from instrumental noise. We also discuss the relation of our experiment to what might be learned by studying the noise in gravitational wave detectors such as LIGO. The paper concludes with a projection that a future search of this nature might be carried out using an atom interferometer in an orbiting satellite. The laboratory apparatus is now being constructed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark Matter Reconstruction in LBAI Experiments with Imperfect Data

Long-baseline atom interferometer (LBAI) experiments offer unprecedented sensitivity to ultralight scalar dark matter (DM) [1], however reconstruction of a putative DM signal with traditional frequency-domain analysis requires ``perfect data (i.e., regularly-sampled with no missing samples). In a real LBAI experiment, there will undoubtedly be imperfections in the data leading to downtime. This downtime can arise from operational considerations (e.g., maintenance), the operational environment (motion of people and animals [2] or elevators), and robustness of the experimental apparatus (e.g., bad atom launches). In this work, we investigate the impact of various downtime models on the overall DM sensitivity of such an experiment. We compare the sensitivity for each downtime model as determined by a ``compound FFT analysis to a baseline no-downtime case. We also show how much sensitivity can be regained by moving to a Lomb-Scargle frequency analysis, as in [2]. Furthermore, we demonstrate reconstruction of the DM wave s phase as well as its frequency. [1] D. Antypas, et al, ``New Horizons: Scalar and Vector Ultralight Dark Matter (2022). arXiv:2203.14915 [2] J. Carlton and C. McCabe, ``From RATs to riches: mitigating anthropogenic and synanthropic noise in atom interferometer searches for ultra-light dark matter (2023). arXiv:2308.101731

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated photonic molecule Brillouin laser with a high-power sub-100-mHz fundamental linewidth

Photonic integrated lasers with an ultra-low fundamental linewidth and a high output power are important for precision atomic and quantum applications, high-capacity communications, and fiber sensing, yet wafer-scale solutions have remained elusive. Here we report an integrated stimulated Brillouin laser (SBL), based on a photonic molecule coupled resonator design, that achieves a sub-100-mHz fundamental linewidth with greater than 10-mW output power in the C band, fabricated on a 200-mm silicon nitride (Si 3 N 4 ) CMOS-foundry compatible wafer-scale platform. The photonic molecule design is used to suppress the second-order Stokes (S2) emission, allowing the primary lasing mode to increase with the pump power without phase noise feedback from higher Stokes orders. The nested waveguide resonators have a 184 million intrinsic and 92 million loaded Q, over an order of magnitude improvement over prior photonic molecules, enabling precision resonance splitting of 198 MHz at the S2 frequency. We demonstrate S2-suppressed single-mode SBL with a minimum fundamental linewidth of 71±18 mHz, corresponding to a 23±6-mHz 2 /Hz white-frequency-noise floor, over an order of magnitude lower than prior integrated SBLs, with an ∼11-mW output power and 2.3-mW threshold power. The frequency noise reaches the resonator-intrinsic thermo-refractive noise from 2-kHz to 1-MHz offset. The laser phase noise reaches −155 dBc/Hz at 10-MHz offset. The performance of this chip-scale SBL shows promise not only to improve the reliability and reduce size and cost but also to enable new precision experiments that require the high-speed manipulation, control, and interrogation of atoms and qubits. Realization in the silicon nitride ultra-low loss platform is adaptable to a wide range of wavelengths from the visible to infrared and enables integration with other components for systems-on-chip solutions for a wide range of precision scientific and engineering applications including quantum sensing, gravitometers, atom interferometers, precision metrology, optical atomic clocks, and ultra-low noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Atom Interferometry for Dark Contents of the Vacuum Searches

A cold atom interferometer is being developed using 85Rb atoms towards a search for the dark contents of the vacuum, and as a test stand for inertial sensing applications. Here we outline the current status of the experiment and report the observation of Ramsey interference fringes in the apparatus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗