Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic mass evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nuclide inventory characterization of EBR-II MOX fuel test pins

Characterization of 3 mixed oxide (MOX) fuel pins from the Experimental Breeder Reactor II (EBR-II) SPA-2/-2B experiment program was performed in support of the Advanced Reactor Experiments for Sodium Fast Reactor Fuels (ARES) joint project between Idaho National Laboratory (INL) and the Japan Atomic Energy Agency (JAEA). The characterization efforts were performed to enable transient testing in the Transient Reactor Test (TREAT) facility at INL and will include post irradiation examination (PIE) and other analyses. MOX fuel pins UW02009, 02011, and 06024 were historically irradiated from 1989 to 1994 for a total of 822.42 effective full power days (EFPDs) and peak burnup of approximately 14.3 at.% (atomic percent of heavy metal atoms, ∼134.4 GWd/t). They had since been placed in storage until a future use was identified. Characterization of the fission products and activation of each fuel pin was necessary to enable removal from storage and subsequent irradiation testing or PIE activities. The initial fuel pin geometry and composition were established using historical documentation. Irradiation history details were utilized to compute irradiated and decayed fuel pin masses, atomic densities, and activities. A pellet-wise axial neutron flux was also computed to assist in evaluation of the axial distribution of {sup 235}U and {sup 239}Pu, per pellet, within each of the test fuel pins. The results computed herein supported experiment design for advanced high-burnup MOX fuel designs under slow transient overpower (MOXTOP) conditions, which was Phase I of the ARES project. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Atomic-oxygen induced structural changes in polyphosphazene films and coatings

Various polymers were exposed to atomic oxygen O(3P) and comparisons made of their stability. The rates of reaction and mass removal for polyphosphazenes exposed to atomic oxygen were found to be significantly lower than for other polymers evaluated in this study. Surface analysis of polyphosphazene films indicated that O(3P) induces rearrangements in the phosphorus-nitrogen backbone of the polymer, resulting in cross-linking and cleavage of some pendant groups that are then replaced by oxygen.

Fewell, Larry L.↗

Atomic oxygen testing with thermal atom systems - A critical evaluation

The use of thermal atom (kinetic energy near 0.04 eV) test methods as a materials selection and screening technique for LEO spacecraft is critically evaluated in this paper. The physics and chemistry of the thermal atom environments are shown to produce specific mass loss rates (mg/sq cm per min) and reaction efficiencies (Re) radically different from those produced in the LEO environment. A response surface study shows that specific mass loss rates change rapidly with plasma-asher parameters and seldom agree with flight data. FEP Teflon is shown to react by a different mechanism than Kapton, polyethylene, or graphite. The Re (Re = volume of material removed/oxygen atom) of Kapton, polyethylene, Mylar, Tedlar, FEP Teflon, and graphite measured in a flowing afterglow apparatus are 0.001 to 0.0001 those measured with high-energy atoms (kinetic energy 1.5 eV or greater) in beam systems or in LEO. The effect of sample temperature and atom impact energy on Re is discussed. A simple kinetic model describing the reaction of atomic oxygen with polymer surfaces is developed. Guidelines and recommendations for thermal atom testing and interpretation of test results are presented.

Koontz, Steven L.↗

Low earth orbit durability evaluation of Haynes 188 solar receiver material

The effects of elevated-temperature vacuum and elevated-temperature atomic oxygen exposure on the mass, surface chemistry, surface morphology, and optical properties of Haynes 188, a possible heat receiver material for space-based solar dynamic power systems, have been studied. Pristine and surface modified Haynes 188 were exposed to vacuum less than or equal to 10 exp -6 torr at 820 C for 5215.5 h, and to atomic oxygen in an air plasma asher at 34 and 827 C for fluences up to 5.6 x 10 exp 21 atoms/sq cm. Results obtained indicate that vacuum heat treatment caused surface morphology and chemistry changes with corresponding optical property changes. Atomic oxygen exposure caused optical property changes which diminished with time. Mass changes are considered to be negligible for both exposures.

De Groh, Kim K.↗

Vacuum ultraviolet radiation and thermal cycling effects on atomic oxygen protective photovoltaic array blanket materials

The importance of synergistic environmental exposure is demonstrated through the evaluation of DuPont 93-1 in simulated LEO environment. Changes in optical properties, surface condition, and mass loss data are described. The qualitative results indicate the necessity for exposure of materials to a series of simulated LEO environments in order to properly determine synergistic effects and demonstrate the overall LEO durability of candidate materials. It is shown that synergistic effects may occur with vacuum thermal cycling combined with VUV radiation followed by atomic oxygen exposure. Testing the durability of candidate solar array blanket materials in a test sequence with necessary synergistic effects makes it possible to determine the appropriate material for providing structural support and maintaining the proper operating temperature for solar cells in the SSF Photovaltaic Power System.

Brady, J.↗

Increasing the Fissile Mass Loading of High-Level Waste Glass Canisters to Greater Than 2,500 g/m 3 at the Savannah River Site

To eliminate future fissile mass loading constraints for the Savannah River Site H-Canyon Facility and Liquid Waste system, the Savannah River National Laboratory recommends a repository evaluation of a uranium fissile mass loading in glass at 7,144 g/m 3 in addition to the existing International Atomic Energy Agency safeguards and security limit of 2,500 g/m 3 total plutonium. This recommended increase above the authorized 2,500 g/m 3 fissile mass loading limit is based on concentrations of uranium and plutonium shown to produce an acceptable glass waste form rather than projections of the maximum fissile mass loading in future sludge batches. An authorized fissile mass loading limit greater than 2,500 g/m 3 will increase facility flexibility, reduce the number of high-level waste canisters produced, and potentially avoid an increase in the Department of Energy Environmental Management mission life without compromising safety or glass product quality.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An X-Ray Spectroscopic Search For Dark Matter And Unidentified Line Signatures In The Perseus Cluster With Hitomi

The reported detection of a 3.5 keV emission signal in the Perseus cluster core by Bulbulet al. (2014, ApJ, 789, 13) was ruled out at high confidence in analysis conducted by Aharonian et al. (2017, ApJ, 837, L15) of X-ray spectra at 5 eV energy resolution obtained with the Hitomi observatory Soft X-ray Spectrometer (SXS). Using the same data, we search the full 2–12 keV SXS energy band for previously unidentified emission and absorption features. No significant unidentified line emission or absorption is found. Line flux upper limits (1σper resolution element) vary with photon energy and assumed intrinsic width, decreasing from∼100 at 2 keV to<10 photons cm−2s−1sr−1over most of the 5–10 keV energy range for a Gaussian line with Doppler broadening of 640 kms−1. Limits for narrower and broader lines have a similar energy dependence and are systematically smaller and larger, respectively. These line flux limits are used to constrain the decay rate of hypothetical dark matter candidates. For the sterile neutrino decay rate, we place new constraints over the mass range of 4–24 keV with mass resolution better than any previous X-ray analysis. Additionally, the accuracy of relevant thermal spectral models and atomic data are evaluated. The Perseus cluster spectra may be described by a composite of multi-temperature thermal and active galactic nuclei (AGN) power-law continua. Superposed on these, a few line emission signals possibly originating from unmodeled atomic processes (including SiXIV and FeXXV)are marginally detected and tabulated. Comparisons with previous X-ray upper limits and future prospects for dark matter searches using high-energy resolution spectroscopy are discussed.

Takayuki Tamura↗

Material interactions with the Low Earth Orbital (LEO) environment: Accurate reaction rate measurements

To resolve uncertainties in estimated LEO atomic oxygen fluence and provide reaction product composition data for comparison to data obtained in ground-based simulation laboratories, a flight experiment has been proposed for the space shuttle which utilizes an ion-neutral mass spectrometer to obtain in-situ ambient density measurements and identify reaction products from modeled polymers exposed to the atomic oxygen environment. An overview of this experiment is presented and the methodology of calibrating the flight mass spectrometer in a neutral beam facility prior to its use on the space shuttle is established. The experiment, designated EOIM-3 (Evaluation of Oxygen Interactions with Materials, third series), will provide a reliable materials interaction data base for future spacecraft design and will furnish insight into the basic chemical mechanisms leading to atomic oxygen interactions with surfaces.

Visentine, James T.↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

High-response on-line gas analysis system for hydrogen-reaction combustion products

The results of testing an on-line quadrupole gas analyzer system are reported. Gas samples were drawn from the exhaust of a hydrogen-oxygen-nitrogen rocket which simulated the flow composition and dynamics at the combustor exit of a supersonic combustion ramjet engine. System response time of less than 50 milliseconds was demonstrated, with analytical accuracy estimated to be + or - 5 percent. For more complex chemical systems with interfering atom patterns, analysis would be more difficult. A cooled-gas pyrometer probe was evaluated as a total temperature indicator and as the primary mass flow measuring element for the total sample flow rate.

Metzler, A. J.↗

Volatile aldehyde emissions from “sub-ohm” vaping devices

"Sub-ohm" atomizers with reduced resistance can deliver more power than conventional electronic cigarettes. Typical battery outputs are 100 watts or more. These devices are particularly popular among young users, and can be a significant source of volatile carbonyls in the indoor environment. Emissions from next-generation sub-ohm vaping products were characterized by determining e-liquid consumption and volatile aldehydes emissions for several combinations of popular high-power configurations. Tests explored the effect of dilution air flow (air vent opening), puffing volume, and coil assembly configuration. The mass of liquid consumed per puff increased as the puff volume increased from 50 to 100 mL, then remained relatively constant for larger puff volumes up to 500 mL. This is likely due to mass transfer limitations at the wick and coil assembly, which reduced the vaporization rate at higher puff volumes. Carbonyl emission rates were systematically evaluated using a 0.15 Ω dual coil atomizer as a function of the puffing volume and dilution air flow, adjusted by setting the air vents to either 100% (fully open), 50%, 25%, or 0% (closed). The highest formaldehyde emissions were observed for the lowest puff volume (50 mL) when the vents 31 were closed (48 ng mg-1), opened at 25% (39 ng mg -1 ) and at 50% (32 ng mg -1 ).. By contrast, 50-mL puffs with 100% open vents, and puff volumes >100 mL for any vent aperture, generated formaldehyde yields of 20 ng mg -1 or lower, suggesting that a significant cooling effect resulted in limited carbonyl formation. Considering the effect of the coil resistance when operated at a voltage of 3.8 V, the amount of liquid evaporated per puff decreased as the resistance increased, in the order of 0.15 Ω > 0.25 Ω > 0.6 Ω consistent with decreasing aerosol temperatures measured at the mouthpiece. Three different configurations of 0.15 Ω coils (dual, quadruple and octuple) were evaluated, observing significant variability. No clear trend was found between carbonyl emission rates and coil resistance or configuration, with highest emissions corresponding to a 0.25 Ω dual coil atomizer. Carbonyl emission rates were compared with those determined using the same methodology for conventional e-cigarettes (lower power tank systems), observing overall lower yields for the sub-ohm devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of atomic oxygen on polymeric materials flown on EOIM-3

Diverse polymeric materials, including several variations of Kapton, were flown on STS-46 as part of the Evaluation of Oxygen Interaction with Materials Experiment (EOIM-3). These materials were flown in the cargo bay and exposed to the space environment July 31 - August 8, 1992, including 40 hours of direct atomic oxygen impingement. The atomic oxygen exposure was approximately 2.2 x 10(exp 20) atoms/sq cm. Polymeric materials flown on EOIM-3 include coated and uncoated Kapton, Tefzel ETFE, Lexan, FEP and TFE Teflon, bulk Halar and PEEK, S383 silicone and Viton elastomeric seal material. Analyses performed included thickness measurements using Dektak and eddy current methods, mass loss, resistance, permeability, hardness, and FTIR. The effects of stress and the space environment on Kapton were also evaluated. Previous EOIM missions on STS-5 and STS-8 and the Long Duration Exposure Facility also contained polymeric material samples. Data from these previous flights are shown for comparison, as well as ground simulation of space environment effects using both thermal energy flow tubes and 5 eV neutral atomic oxygen beam facilities. Reaction efficiencies for the various atomic oxygen exposure conditions are discussed.

Kamenetzky, Rachel R.↗

Co-Investigator for the Planet B NMS

This is the final report. The effort under this contract consisted mainly with meetings and discussions with our NASA/GSFC and ISAS partners of the neutral mass spectrometer team of the Nozomi mission. The activities were to serve the purpose to prepare and co-ordinate our activities in preparation for the anticipated data analysis and science interpretation of the data after Mars orbit insertion. Given the unfortunate initial delays this effort included a number of visits to ISAS in Tokyo and participation in co-ordination and science workshops. We participated in a paper describing the instrument, which was published. We also worked on certain theoretical calculations in order to evaluate measurement opportunities for the mass spectrometer at Mars. The major aspect of this effort was a series of calculations on the feasibility of measuring hot atoms in the upper atmosphere. We calculated the densities of hot oxygen and carbon. Although this work established that their abundance is probably below the sensitivity of the mass spectrometer, it was of scientific importance and the results were presented at scientific meetings and published in the open literature.

Nagy, Andrew↗

Precision Local Burnup Assessment Through Dynamic Peak Fitting in Atom Probe Tomography for Depleted, Enriched, and Irradiated Metallic and Ceramic Fuels

Abstract Burnup estimation in nuclear fuels is vital for evaluating fuel performance, transportation, and safe fuel storage. Accurate assessments of burnup from service period and spent fuels involve tracking the consumption of fissile isotopes of uranium (U) offering a direct insight into energy changes within the fuels especially for thermal spectrum reactors. In current approach, mass spectroscopic technique in atom probe tomography (APT) is utilized for accurate quantification of U isotopes. Quantification of U peaks in mass spectrum is performed on asymmetric shapes due to delayed signals, known as thermal tails, particularly for poorly conducting samples analyzed in laser mode. In this study, we introduce a novel quantification tool for isotopic analysis from APT datasets by developing a fitting algorithm based on shapes of the peaks. A MATLAB-based dynamic peak fitting toolbox is developed and designed to adapt to various peak shapes, ensuring accurate quantification of U isotopes. The effectiveness of this approach is demonstrated in standard Ni-Cr sample, depleted and enriched U samples, and U-based fuels with different burnup levels. The viability of this approach for isotopic quantification is demonstrated on both metallic and ceramic fuels.

Burnup↗

Modeling the Oxygen K Absorption in the Interstellar Medium: An XMM-Newton View of Sco X-1

We investigate the absorption structure of the oxygen in the interstellar medium by analyzing XMM-Newton observations of the low mass X-ray binary Sco X-1. We use simple models based on the O I atomic cross section from different sources to fit the data and evaluate the impact of the atomic data in the interpretation of astrophysical observations. We show that relatively small differences in the atomic calculations can yield spurious results. We also show that the most complete and accurate set of atomic cross sections successfully reproduce the observed data in the 21 - 24.5 Angstrom wavelength region of the spectrum. Our fits indicate that the absorption is mainly due to neutral gas with an ionization parameter of Epsilon = 10(exp -4) erg/sq cm, and an oxygen column density of N(sub O) approx. = 8-10 x 10(exp 17)/sq cm. Our models are able to reproduce both the K edge and the K(alpha) absorption line from O I, which are the two main features in this region. We find no conclusive evidence for absorption by other than atomic oxygen.

Garcia, J.↗

Preliminary evaluation of glass resin materials for solar cell cover use

Silicon solar cells and silicon wafers coated with a heat-curable resin consisting of alternating Si-O atoms were subjected to three tests to evaluate the potential utility of this coating in space environments. These included UV irradiation in vacuum at an intensity of 10 air mass zero UV energy-equivalent solar constants for 728 hours followed by a long thermal cycle; 15 thermal shock cycles between 100 C and minus 196 C; and high temperature and humidity (65 C at 90% relative humidity). The UV tests resulted in a 8 to 24% loss in short-circuit current and darkening of the covers. Modification of the resin to provide a better match between the coefficients of expansion of the resin and silicon improved resistance to thermal shock, but also increased the darkening effect under UV irradiation. Silicon wafers coated with the resin were not adversely affected by the temperature/humidity test.

Marsik, S. J.↗

Understanding atom probe’s analytical performance for iron oxides using correlation histograms and ab initio calculations

Abstract Field evaporation from ionic or covalently bonded materials often leads to the emission of molecular ions. The metastability of these molecular ions, particularly under the influence of the intense electrostatic field (10 10 Vm −1 ), makes them prone to dissociation with or without an exchange of energy amongst them. These processes can affect the analytical performance of atom probe tomography (APT). For instance, neutral molecules formed through dissociation may not be detected at all or with a time of flight no longer related to their mass, causing their loss from the analysis. Here, we evaluated the changes in the measured composition of FeO, Fe 2 O 3 and Fe 3 O 4 across a wide range of analysis conditions. Possible dissociation reactions are predicted by density-functional theory calculations considering the spin states of the molecules. The energetically favoured reactions are traced on to the multi-hit ion correlation histograms, to confirm their existence within experiments, using an automated Python-based routine. The detected reactions are carefully analyzed to reflect upon the influence of these neutrals from dissociation reactions on the performance of APT for analysing iron oxides.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomic Oxygen (ATOX) simulation of Teflon FEP and Kapton H surfaces using a high intensity, low energy, mass selected, ion beam facility

A high intensity (greater than 10(exp 15) ions/sq cm) low energy (down to 5 eV) mass selected ion beam (MSIB) facility was used to study the effects of ATOX on two polymers commonly used for space applications (Kapton H and Teflon FEP). The polymers were exposed to O(+) and Ne(+) fluences on 10(exp 15) - 10(exp 19) ions/sq cm, using 30eV ions. A variety of analytical methods were used to analyze the eroded surfaces including: (1) atomic force microscopy (AFM) for morphology measurements; (2) total mass loss measurements using a microbalance; (3) surface chemical composition using x-ray photoelectron spectroscopy (XPS), and (4) residual gas analysis (RGA) of the released gases during bombardment. The relative significance of the collisional and chemical degradation processes was evaluated by comparing the effects of Ne(+) and O(+) bombardment. For 30 eV ions it was found that the Kapton is eroded via chemical mechanisms while Teflon FEP is eroded via collisional mechanisms. AFM analysis was found very powerful in revealing the evolution of the damage from its initial atomic scale (roughness of approx. 1 nm) to its final microscopic scale (roughness greater than 1 micron). Both the surface morphology and the average roughness of the bombarded surfaces (averaged over 1 micron x 1 micron images by the system's computer) were determined for each sample. For 30 eV a non linear increase of the Kapton roughness with the O(+) fluence was discovered (a slow increase rate for fluences phi less than 5 x 10(exp 17) O(+)/sq cm, and a rapid increase rate for phi greater than 5 x 10(exp 17) O(+)/sq cm). Comparative studies on the same materials exposed to RF and DC oxygen plasmas indicate that the specific details of the erosion depend on the simulation facility emphasizing the advantages of the ion beam facility.

Vered, R.↗