Search NASA⌕ Search

SEARCH · Search NASA

Results for “auditing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pascua Yaqui Tribe Energy Audit (Final Report)

The Pascua Yaqui Tribe has the goal of reducing energy use and costs in its government facilities and housing. In a proactive effort to meet the Tribe's needs an energy audit was performed to accomplish the following goals: Develop an energy efficiency implementation strategy. Prepare an energy audit to identify cost-effective energy efficiency opportunities. Plan and conduct a level II energy audit in tribal government buildings and tribal housing. The audit encompassed four tribal government buildings and a group of residential structures. The purpose of this project was to assess the various facilities energy use in order to inform a means to lower annual consumption. An evaluation of each facility's historical energy and major energy-consuming equipment was performed, and energy conservation measures (ECM's) were identified. An average of 4 ECM's where recommended for each facility. If each facility's recommended ECM's are implemented, the average calculated yearly benefits to the government and residential buildings would result in a 48.3% reduction in electrical energy/costs savings and a 14.4% reduction in natural gas energy/costs savings. Recommended projects for implementation include: Interior Lighting Upgrade, Exterior Lighting Upgrade, Solar Pool Covers, Retro-Commissioning, Low Volt Fixtures, Plug Load Management System, Occupancy Sensor Control, and Solar PV for government/casino buildings and appliance, window, HVAC, Weather Stripping, and water heaters replacement in residences.

03 NATURAL GAS↗

simuwatt - A Tablet Based Electronic Auditing Tool

'simuwatt Energy Auditor' (TM) is a new tablet-based electronic auditing tool that is designed to dramatically reduce the time and cost to perform investment-grade audits and improve quality and consistency. The tool uses the U.S. Department of Energy's OpenStudio modeling platform and integrated Building Component Library to automate modeling and analysis. simuwatt's software-guided workflow helps users gather required data, and provides the data in a standard electronic format that is automatically converted to a baseline OpenStudio model for energy analysis. The baseline energy model is calibrated against actual monthly energy use to ASHRAE Standard 14 guidelines. Energy conservation measures from the Building Component Library are then evaluated using OpenStudio's parametric analysis capability. Automated reporting creates audit documents that describe recommended packages of energy conservation measures. The development of this tool was partially funded by the U.S. Department of Defense's Environmental Security Technology Certification Program. As part of this program, the tool is being tested at 13 buildings on 5 Department of Defense sites across the United States. Results of the first simuwatt audit tool demonstration are presented in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FEMP Facility Evaluation (Audit) Decision Tree

This document is a resource to be used in concert with FEMP Audit Definitions, FEMP Consolidated Facility Management Guidance, and agency best practices and expert judgment—for agencies to use to determine the best approaches to evaluate their facilities. It features a decision tree that provides a framework for agencies to interpret gathered facility data to understand the existing conditions; benchmark the facility against others in the portfolio to determine whether an on-site or remote audit is appropriate for a facility; determine the best remote or on-site audit level of detail to meet agency facility auditing goals, such as meeting Energy Independence and Security Act of 2007 requirements and developing projects; and improve their energy and water management programs.

auditing↗

SU-E-T-282: Dose Measurements with An End-To-End Audit Phantom for Stereotactic Radiotherapy

Purpose: Report on dose measurements as part of an end-to-end test for stereotactic radiotherapy, using a new audit tool, which allows audits to be performed efficiently either by an onsite team or as a postal audit. Methods: Film measurements have been performed with a new Stereotactic Cube Phantom. The phantom has been designed to perform Winston Lutz type position verification measurements and dose measurements in one setup. It comprises a plastic cube with a high density ball in its centre (used for MV imaging with film or EPID) and low density markers in the periphery (used for Cone Beam Computed Tomography, CBCT imaging). It also features strategically placed gold markers near the posterior and right surfaces, which can be used to calculate phantom rotations on MV images. Slit-like openings allow insertion of film or other detectors.The phantom was scanned and small field treatment plans were created. The fields do not traverse any inhomogeneities of the phantom on their paths to the measurement location. The phantom was setup at the delivery system using CBCT imaging. The calculated treatment fields were delivered, each with a piece of radiochromic film (EBT3) placed in the anterior film holder of the phantom. MU had been selected in planning to achieve similar exposures on all films. Calibration films were exposed in solid water for dose levels around the expected doses. Films were scanned and analysed following established procedures. Results: Setup of the cube showed excellent suitability for CBCT 3D alignment. MV imaging with EPID allowed for clear identification of all markers. Film based dose measurements showed good agreement for MLC created fields down to 0.5 mm × 0.5 mm. Conclusion: An end-to-end audit phantom for stereotactic radiotherapy has been developed and tested.

60 APPLIED LIFE SCIENCES↗

Towards Streamlining Auditing for Compliance With Requirements in Open-Source Software at NASA

Context: NASA requires all software to meet several requirements (NPR 7150.2) depending on software criticality. The instantiation of these requirements may vary per project; however, once decided upon, projects must undergo audits to evaluate compliance with these requirements. Aim: We propose that audit effort can be reduced when requirements are realized by leveraging commonly used open-source infrastructure for version control, issue tracking and continuous integration, and the generated records are analyzed using a repository mining software tool to quantify process compliance. Method: We perform a case study in the NASA-funded Copilot project, utilizing Kaiaulu, a repository mining software tool. We define four software compliance metrics based on the Copilot’s requirements, and analyze their impact on source code quality. Results: Our work demonstrates how it is possible to leverage existing open source tools and platforms to facilitate software certification and qualification, and to streamline the auditing process required even when stringent requirements must be enforced. Conclusion: Together, both project and tool can be utilized to visualize project compliance, and metrics can be defined to more easily identify process irregularities to minimize auditing efforts. Project Repository: github.com/Copilot-Language/copilot Tool Repository: github.com/sailuh/kaiaulu

code-quality↗

Scaling Building Energy Audits through Machine Learning Methods on Novel Drone Image Data

Building energy audits are time-consuming and labor-intensive. This paper describes a new method using machine learning (ML) techniques on novel data sources (drone images) to improve the identification of building characteristics and retrofit opportunities, and thereby reduce the effort for audits. The new ML method includes: (1) Building footprint extraction using line extraction, polygonization, and polygon-merging, (2) Building envelope extraction using PIX4d modeling software to reconstruct a building 3D model, (3) Visualization tool for viewing images from the 3D model, (4) Window-to-wall ratio (WWR) using state-of-art deep neural network semantic segmentation, (5) Envelope thermal anomaly detection using an unsupervised machine learning clustering algorithm, and (6) Rooftop energy equipment detection based on an object detection algorithm. The testing of this method involved a comparison of additional ML-generated information overlaid on current ‘state-of-practice’ audit and remote assessment baselines using evaluation metrics: labor time and associated cost, marginal benefits of using ML-generated information in workflows for audits and remote assessments, integration potential with existing processes and tools, and replicability/scalability of the method. In two test buildings in California that had comprehensive drawings and meter data available, the ML method effectively generated a building footprint, envelope, rooftop equipment, WWR, and locations of envelope thermal anomalies. Projected target segments of the ML method are sites with minimal drawings and energy data, and underserved sectors such as multistoried housing, disadvantaged communities, and schools for which the ML method can enable identification of building asset characteristics and prioritization of envelope retrofits and decentralized energy equipment retrofits.

Singh, Reshma↗

Impact of Using Audit Data to Improve the Evidence-Based Use of Single-Fraction Radiation Therapy for Bone Metastases in British Columbia

Purpose: To assess the impact of a population-based intervention to increase the consistency and use of single-fraction radiation therapy (SFRT) for bone metastases. Methods and Materials: In 2012, an audit of radiation therapy prescriptions for bone metastases in British Columbia identified significant interphysician and -center (26%-73%) variation in the use of SFRT. Anonymous physician-level and identifiable regional cancer center SFRT use data were presented to all radiation oncologists, together with published guidelines, meta-analyses, and recommendations from practice leaders. The use of SFRT for bone metastases from 2007 through 2011 was compared with use of SFRT in 2013, to assess the impact of the audit and educational intervention. Multilevel logistic regression was used to assess the relationship between the usage of SFRT and the timing of the radiation while controlling for potentially confounding variables. Physician and center were included as group effects to account for the clustered structure of the data. Results: A total of 16,898 courses of RT were delivered from 2007 through 2011, and 3200 courses were delivered in 2013. The rates of SFRT use in 2007, 2008, 2009, 2010, 2011, and 2013 were 50.5%, 50.9%, 48.3%, 48.5%, 48.0%, and 59.7%, respectively (P<.001). Use of SFRT increased in each of 5 regional centers: A: 26% to 32%; B: 36% to 56%; C: 39% to 57%; D: 49% to 56%; and E: 73% to 85.0%. Use of SFRT was more consistent; 3 of 5 centers used SFRT for 56% to 57% of bone metastases RT courses. The regression analysis showed strong evidence that the usage of SFRT increased after the 2012 intervention (odds ratio 2.27, 95% confidence interval 2.06-2.50, P<.0001). Conclusion: Assessed on a population basis, an audit-based intervention increased utilization of SFRT for bone metastases. The intervention reversed a trend to decreasing SFRT use, reduced costs, and improved patient convenience. This suggests that dissemination of programmatic quality indicators in oncology can lead to increased utilization of evidence-based practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Chart Audits as a Potential Process Improvement Strategy Within the Radiation Therapy Department of a Community-Based Cancer Center

Within the health care profession, many organizations rely on routine clinical chart audits to detect areas for enhancement and potential triggers for error. Effective clinician documentation within the electronic treatment record is mandatory should high-quality care be maintained. This study aimed to determine what type of information might be obtained from radiation therapy treatment chart audits. This information would help to inform areas for improvement within the department and to determine whether introducing clinical chart audits as routine would be of benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of a radiophotoluminescent glass dosimeter to nonreference condition dosimetry in the postal dose audit system

Purpose: The purpose of this study was to obtain a set of correction factors of the radiophotoluminescent glass dosimeter (RGD) output for field size changes and wedge insertions. Methods: Several linear accelerators were used for irradiation of the RGDs. The field sizes were changed from 5 × 5 cm to 25 × 25 cm for 4, 6, 10, and 15 MV x-ray beams. The wedge angles were 15°, 30°, 45°, and 60°. In addition to physical wedge irradiation, nonphysical (dynamic/virtual) wedge irradiations were performed. Results: The obtained data were fitted with a single line for each energy, and correction factors were determined. Compared with ionization chamber outputs, the RGD outputs gradually increased with increasing field size, because of the higher RGD response to scattered low-energy photons. The output increase was about 1% per 10 cm increase in field size, with a slight difference dependent on the beam energy. For both physical and nonphysical wedged beam irradiation, there were no systematic trends in the RGD outputs, such as monotonic increase or decrease depending on the wedge angle change if the authors consider the uncertainty, which is approximately 0.6% for each set of measured points. Therefore, no correction factor was needed for all inserted wedges. Based on this work, postal dose audits using RGDs for the nonreference condition were initiated in 2010. The postal dose audit results between 2010 and 2012 were analyzed. The mean difference between the measured and stated doses was within 0.5% for all fields with field sizes between 5 × 5 cm and 25 × 25 cm and with wedge angles from 15° to 60°. The standard deviations (SDs) of the difference distribution were within the estimated uncertainty (1SD) except for the 25 × 25 cm field size data, which were not reliable because of poor statistics (n = 16). Conclusions: A set of RGD output correction factors was determined for field size changes and wedge insertions. The results obtained from recent postal dose audits were analyzed, and the mean differences between the measured and stated doses were within 0.5% for every field size and wedge angle. The SDs of the distribution were within the estimated uncertainty, except for one condition that was not reliable because of poor statistics.

07 ISOTOPE AND RADIATION SOURCES↗

Environmental Compliance Audit& Assessment Program Manual

This document describes the elements, schedule, roles, and responsibilities of the Lawrence Berkeley National Laboratory (LBNL) Environmental Compliance Audit & Assessment Program (ECAAP). The ECAAP has been developed to meet the requirements of DOE Order 450.1A,1 and Executive Order 13423.2 These referenced Orders stipulate that government agencies must develop environmental compliance audit programs to monitor and improve compliance with environmental regulations. As stated specifically in the DOE Order, as a part of a DOE facility's Environmental Management System (EMS), 'An environmental compliance audit and review program that identifies compliance deficiencies and root causes of non-compliance' shall be developed and implemented. The ECAAP has also been developed to satisfy LBNL's institutional technical assurance assessment requirements promulgated in the Environment, Safety and Health (ES&H) Self-Assessment Program (LBNL/PUB-5344) and described by the ES&H Technical Assurance Program (TAP) Manual (LBNL/PUB-913E). The ES&H TAP Manual provides the framework for systematic reviews of ES&H programs with the intent to provide assurance that these programs comply with their guiding regulations, are effective, and are properly implemented. As required by the DOE and Executive Orders and by LBNL's TAP, the goal of the ECAAP is to identify environmental regulatory compliance deficiencies and to determine their respective causes. The ECAAP then provides a means of correcting any deficiencies identified, and leads to continually improving environmental compliance performance.

99 GENERAL AND MISCELLANEOUS↗

Audit Report, "Fire Protection Deficiencies at Los Alamos National Laboratory"

The Department of Energy's Los Alamos National Laboratory (Los Alamos) maintains some of the Nation's most important national security assets, including nuclear materials. Many of Los Alamos' facilities are located in close proximity to one another, are occupied by large numbers of contract and Federal employees, and support activities ranging from nuclear weapons design to science-related activities. Safeguarding against fires, regardless of origin, is essential to protecting employees, surrounding communities, and national security assets. On June 1, 2006, Los Alamos National Security, LLC (LANS), became the managing and operating contractor for Los Alamos, under contract with the Department's National Nuclear Security Administration (NNSA). In preparation for assuming its management responsibilities at Los Alamos, LANS conducted walk-downs of the Laboratory's facilities to identify pre-existing deficiencies that could give rise to liability, obligation, loss or damage. The walk-downs, which identified 812 pre-existing fire protection deficiencies, were conducted by subject matter professionals, including fire protection experts. While the Los Alamos Site Office has overall responsibility for the effectiveness of the fire protection program, LANS, as the Laboratory's operating contractor, has a major, day-to-day role in minimizing fire-related risks. The issue of fire protection at Los Alamos is more than theoretical. In May 2000, the 'Cerro Grande' fire burned about 43,000 acres, including 7,700 acres of Laboratory property. Due to the risk posed by fire to the Laboratory's facilities, workforce, and surrounding communities, we initiated this audit to determine whether pre-existing fire protection deficiencies had been addressed. Our review disclosed that LANS had not resolved many of the fire protection deficiencies that had been identified in early 2006: (1) Of the 296 pre-existing deficiencies we selected for audit, 174 (59 percent) had not been corrected; and, (2) A substantial portion of the uncorrected deficiencies, 86 (49 percent) were considered by the walk-down teams to be significant enough to warrant compensatory actions until the deficiency was corrected or was tracked to closure through implementation of corrective actions. Further, we found that 32 of the significant deficiencies had been closed by the previous Los Alamos contractor, prior to LANS assuming responsibility for operation of the Laboratory, even though the deficiencies had not been corrected. A fire protection expert provided technical support during the audit. As an example of uncorrected problems, LANS had not resolved, by performing periodic tests, a deficiency identified in 2006 regarding a kitchen hood fire suppression system in a facility located within the Los Alamos Neutron Science Center. Such systems are required to be tested twice a year by the National Fire Protection Association standard, a standard that had been adopted by Department of Energy under DOE Order 420.1B. Yet, in 2006, the LANS walk-down team recognized that this system had not been inspected since May 2004 and noted that deficient suppression systems could result in significantly high levels of property damage and loss. After we brought this issue to management's attention on February 6, 2009, LANS officials stated that the Laboratory would correct this deficiency. As with the problems involving the fire suppression system, we observed that LANS had not always corrected life safety deficiencies involving building exits at one of its primary facilities. This included providing a secondary emergency exit for a building with occupants on multiple floor levels. LANS had removed personnel from the third floor and improved the sprinkler system of the facility, but it had still not provided a secondary exit for personnel on the second floor by the time we completed our review. NNSA has since stated that this fire protection issue will be completely addressed by relocating personnel from the second floor. Perhaps most serious, our testing revealed that a number of deficiencies were formally closed even though actual corrective action had not been completed. Notably, we observed that action had not been taken to resolve a recommendation to replace a fire alarm panel found to be unreliable. After the walk-down was conducted but prior to contract transition, the former contractor closed the recommendation in its action tracking database even though the panel had not been replaced. The walk-down team had categorized the fire alarm system as requiring replacement since it had been modified many times, was old and obsolete, and had very limited available spare parts. In fact, the walk-down team concluded that the panel 'must be considered to be unreliable and should have a very high priority for replacement'.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Audit Report on "Protection of the Department of Energy's Unclassified Sensitive Electronic Information"

The Department of Energy and its contractors store and process massive quantities of sensitive information to accomplish national security, energy, science, and environmental missions. Sensitive unclassified data, such as personally identifiable information (PII), official use only, and unclassified controlled nuclear information require special handling and protection to prevent misuse of the information for inappropriate purposes. Industry experts have reported that more than 203 million personal privacy records have been lost or stolen over the past three years, including information maintained by corporations, educational institutions, and Federal agencies. The loss of personal and other sensitive information can result in substantial financial harm, embarrassment, and inconvenience to individuals and organizations. Therefore, strong protective measures, including data encryption, help protect against the unauthorized disclosure of sensitive information. Prior reports involving the loss of sensitive information have highlighted weaknesses in the Department's ability to protect sensitive data. Our report on Security Over Personally Identifiable Information (DOE/IG-0771, July 2007) disclosed that the Department had not fully implemented all measures recommended by the Office of Management and Budget (OMB) and required by the National Institute of Standards and Technology (NIST) to protect PII, including failures to identify and encrypt PII maintained on information systems. Similarly, the Government Accountability Office recently reported that the Department had not yet installed encryption technology to protect sensitive data on the vast majority of laptop computers and handheld devices. Because of the potential for harm, we initiated this audit to determine whether the Department and its contractors adequately safeguarded sensitive electronic information. The Department had taken a number of steps to improve protection of PII. Our review, however, identified opportunities to strengthen the protection of all types of sensitive unclassified electronic information and reduce the risk that such data could fall into the hands of individuals with malicious intent. In particular, for the seven sites we reviewed: (1) Four sites had either not ensured that sensitive information maintained on mobile devices was encrypted. Or, they had improperly permitted sensitive unclassified information to be transmitted unencrypted through email or to offsite backup storage facilities; (2) One site had not ensured that laptops taken on foreign travel, including travel to sensitive countries, were protected against security threats; and, (3) Although required by the OMB since 2003, we learned that programs and sites were still working to complete Privacy Impact Assessments - analyses designed to examine the risks and ramifications of using information systems to collect, maintain, and disseminate personal information. Our testing revealed that the weaknesses identified were attributable, at least in part, to Headquarters programs and field sites that had not implemented existing policies and procedures requiring protection of sensitive electronic information. In addition, a lack of performance monitoring contributed to the inability of the Department and the National Nuclear Security Administration (NNSA) to ensure that measures were in place to fully protect sensitive information. As demonstrated by previous computer intrusion-related data losses throughout the Department, without improvements, the risk or vulnerability for future losses remains unacceptably high. In conducting this audit, we recognized that data encryption and related techniques do not provide absolute assurance that sensitive data is fully protected. For example, encryption will not necessarily protect data in circumstances where organizational access controls are weak or are circumvented through phishing or other malicious techniques. However, as noted by NIST, when used appropriately, encryption is an effective tool that can, as part of an overall risk-management strategy, enhance security over critical personal and other sensitive information. The audit disclosed that Sandia National Laboratories had instituted a comprehensive program to protect laptops taken on foreign travel. In addition, the Department issued policy after our field work was completed that should standardize the Privacy Impact Assessment process, and, in so doing, provide increased accountability. While these actions are positive steps, additional effort is needed to help ensure that the privacy of individuals is adequately protected and that sensitive operational data is not compromised. To that end, our report contains several recommendations to implement a risk-based protection scheme for the protection of sensitive electronic information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pedestrian and traffic safety in parking lots at SNL/NM : audit background report.

This report supplements audit 2008-E-0009, conducted by the ES&H, Quality, Safeguards & Security Audits Department, 12870, during fall and winter of FY 2008. The study evaluates slips, trips and falls, the leading cause of reportable injuries at Sandia. In 2007, almost half of over 100 of such incidents occurred in parking lots. During the course of the audit, over 5000 observations were collected in 10 parking lots across SNL/NM. Based on benchmarks and trends of pedestrian behavior, the report proposes pedestrian-friendly features and attributes to improve pedestrian safety in parking lots. Less safe pedestrian behavior is associated with older parking lots lacking pedestrian-friendly features and attributes, like those for buildings 823, 887 and 811. Conversely, safer pedestrian behavior is associated with newer parking lots that have designated walkways, intra-lot walkways and sidewalks. Observations also revealed that motorists are in widespread noncompliance with parking lot speed limits and stop signs and markers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Audit Report on "The Department's Management of the ENERGY STAR Program"

The American Recovery and Reinvestment Act (Recovery Act) authorized about $300 million in consumer rebate incentives for purchases of products rated under the 'ENERGY STAR' Program. ENERGY STAR, a voluntary labeling program established in 1992, provides consumers with energy efficiency data for a range of products so that they can make informed purchase judgments. The overall goal of the program is to encourage consumers to choose energy efficient products, advancing the nationwide goal of reducing energy consumption. The U.S. Environmental Protection Agency (EPA) managed the ENERGY STAR Program on a stand-alone basis until 1996 when it joined forces with the Department of Energy (Department). A Memorandum of Cooperation expanded the ENERGY STAR product categories, giving the Department responsibility for overseeing eight product categories such as windows, dishwashers, clothes washers, and refrigerators, while EPA retained responsibility for electronic product categories and heating, ventilating, and cooling equipment. Each agency is responsible for setting product efficiency specifications for those items under its control and for ensuring the proper use of the ENERGY STAR label in the marketplace. In August 2007, the EPA Office of Inspector General issued an audit report identifying significant control weaknesses in EPA's management of ENERGY STAR. The Department, concerned by the findings at EPA and eager to improve its own program, developed an approach to verify adherence to product specifications, ensure proper use of the ENERGY STAR label in the marketplace, and improve the establishment of product specifications. As evidenced by the commitment of $300 million in Recovery Act funds, the ENERGY STAR Program plays an important role in the U.S. efforts to reduce energy consumption. We initiated this audit to determine whether the Department had implemented the actions it announced in 2007 to strengthen the Program. The Department had not implemented planned improvements in the ENERGY STAR Program. Our audit revealed that officials had not: (1) Developed a formal quality assurance program to help ensure that product specifications were adhered to; (2) Effectively monitored the use of the ENERGY STAR label to ensure that only qualifying products were labeled as compliant; and (3) Formalized procedures for establishing and revising product specifications and for documenting decisions regarding those specifications. In our judgment, the delay in the Department's planned improvements in its management of the ENERGY STAR Program could reduce consumer confidence in the integrity of the ENERGY STAR label. Such loss of credibility could reduce energy savings, increase consumer risk, and diminish the value of the recent infusion of $300 million for ENERGY STAR rebates under the Recovery Act.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Auditing Tool for Retrofit Building Projects [SWR-11-07]

Building energy auditors regularly use notepads, physical forms, or simple spreadsheets to inventory energy consuming devices in buildings and audit overall performance. Mobile computing devices such as smart phones or tablet computers with camera inputs may be used to automatically capture relevant information and format audit input in a way that streamlines work flows and reduces the likelihood of error. As an example. an auditor could walk through a space holding a mobile device, which automatically identifies and appliances, windows, etc. This information would automatically be added to a mobile database associated with the building for later integration with a larger building audit database. The user experience would require little or no manual input, and could integrate with tools to automate used to automate data collection for building energy modeling.

Parker, Andrew↗

Multifamily Tool for Energy Audits (MulTEA) Engineering Manual (Version 1)

The Multifamily Tool for Energy Audits (MulTEA) is an energy audit tool designed to provide auditors with an improved energy simulation tool for multifamily buildings and an improved tool for identifying cost-effective energy-efficiency retrofit measures for multifamily buildings. MulTEA is designed specifically to help states and local weatherization agencies implement the Department of Energy (DOE) Weatherization Assistance Program. MulTEA was developed jointly by the Oak Ridge National Laboratory (ORNL) and the Lawrence Berkeley National Laboratory (LBNL). MulTEA is part of ORNL’s web-based Weatherization Assistant suite of audit tools (https://weatherization.ornl.gov/softwaredescription/). The energy calculation engine including the DOE- 2 simulation model and supplementary calculation modules is shared by MulTEA and LBNL’s Home Energy Saver pro (HESpro) (http://hespro.lbl.gov/pro/). On the ORNL side, the energy calculation engine is coupled with a user interface and output reporting capabilities based on Weatherization Assistance Program regulations and guidelines pertinent to MulTEA. On the LBNL side, the same engine will be used in HESpro to expand it to handle multifamily buildings. MulTEA is designed to address small and large multifamily buildings with decentralized and centralized heating, ventilation, and air-conditioning (HVAC) and domestic hot water (DHW) systems. Version 1 of MulTEA addresses small multifamily buildings with decentralized HVAC systems, and decentralized or centralized DHW systems. The capability to model large buildings and centralized HVAC systems will be incorporated in Version 2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CY20 AIHA Internal Audit of ALAB and NIF-HPL and CY20 Management Review of ALAB

An internal audit was performed in ALAB to ISO 17025:2017; EPA LQST and AIHA requirements using the current AIHA Checklist. The scope of the internal audit was the annual review of AIHA-accredited industrial hygiene methods performer in both ALAB and NIF HPL. The Internal audit resulted in 3 deficiencies and 3 comments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Document Traceability Internal Audit of the Analytical Laboratory Report on 08-26-2021

An internal audit was performed in ALAB 8/25/21 to the NELAC 2016 Standard requirements using the NELAC 2016 checklist (TNI 2016 CSDP-Volume1Checklist-Master-2-15-18-v9). The scope of the internal audit was a document traceability of the environmental testing in LRF-00118, LRF00095, and LRF 00133 performed in ALAB. The internal audit resulted in five deficiencies and two comments. The deficiencies were addressed using the ALAB non-conformance reporting system, see ALAB NCRs 10002742-10002746. FRM-5100 Management Observation and NCRs are attached.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗