Search NASA⌕ Search

SEARCH · Search NASA

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NASA Tech Briefs, June 2013

Topics include: Cloud Absorption Radiometer Autonomous Navigation System - CANS, Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis, Discrete Data Qualification System and Method Comprising Noise Series Fault Detection, Simple Laser Communications Terminal for Downlink from Earth Orbit at Rates Exceeding 10 Gb/s, Application Program Interface for the Orion Aerodynamics Database, Hyperspectral Imager-Tracker, Web Application Software for Ground Operations Planning Database (GOPDb) Management, Software Defined Radio with Parallelized Software Architecture, Compact Radar Transceiver with Included Calibration, Software Defined Radio with Parallelized Software Architecture, Phase Change Material Thermal Power Generator, The Thermal Hogan - A Means of Surviving the Lunar Night, Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers, Nano-Ceramic Coated Plastics, Preparation of a Bimetal Using Mechanical Alloying for Environmental or Industrial Use, Phase Change Material for Temperature Control of Imager or Sounder on GOES Type Satellites in GEO, Dual-Compartment Inflatable Suitlock, Modular Connector Keying Concept, Genesis Ultrapure Water Megasonic Wafer Spin Cleaner, Piezoelectrically Initiated Pyrotechnic Igniter, Folding Elastic Thermal Surface - FETS, Multi-Pass Quadrupole Mass Analyzer, Lunar Sulfur Capture System, Environmental Qualification of a Single-Crystal Silicon Mirror for Spaceflight Use, Planar Superconducting Millimeter-Wave/Terahertz Channelizing Filter, Qualification of UHF Antenna for Extreme Martian Thermal Environments, Ensemble Eclipse: A Process for Prefab Development Environment for the Ensemble Project, ISS Live!, Space Operations Learning Center (SOLC) iPhone/iPad Application, Software to Compare NPP HDF5 Data Files, Planetary Data Systems (PDS) Imaging Node Atlas II, Automatic Calibration of an Airborne Imaging System to an Inertial Navigation Unit, Translating MAPGEN to ASPEN for MER, Support Routines for In Situ Image Processing, and Semi-Supervised Eigenbasis Novelty Detection.

Source record↗

Remote sensing X-ray spectrometer

Spectrometer measures chemical composition of lunar rocks by remote sensing from orbit and senses lunar X-rays produced by interaction of solar X-rays and elements on the lunar surface. Instrument features high sensitivity, data handling system that accumulates and prepares data for telemetry, and automatic calibration.

Adler, I.↗

Testing methods and techniques: Environmental testing: A compilation

Various devices and techniques are described for testing hardware and components in four special environments: low temperature, high temperature, high pressure, and vibration. Items ranging from an automatic calibrator for pressure transducers to a fixture for testing the susceptibility of materials to ignition by electric spark are included.

Source record↗

NASA Lyndon B. Johnson Space Center's Metrology Program

Since the establishment in 1962 of the NASA-JSC Metrology Program, the Reference Standards Laboratory has successfully accomplished its goal and objectives. An on-going laboratory surveillance program, established for insuring a continuing validation of the measurements required at the center, is shown to remain at the forefront of modern technology through its involvement in activities such as the NBS sponsored Measurement Assurance Programs and the utilization of an Automatic Calibration System.

Suraci, J. M.↗

Redundant Strapdown Laser Gyro Navigation System

For the last several years, NASA has pursued the development of low-cost high-reliability inertial navigation systems that would satisfy a broad spectrum of future space and avionics missions. Two specific programs have culminated in the construction of a Redundant Strapdown Laser Gyro Navigation System. These two programs were for development of a space ultrareliable modular computer (SUMC) and a redundant laser gyro inertial measurement unit (IMU). The SUMC is a digital computer that employs state-of-the-art large-scale integrated circuits configured in a functional modular breakdown. The redundant laser gyro IMU is a six-pack strapdown sensor package in a dodecahedron configuration which uses six laser gyros to provide incremental angular positions and six accelerometers for linear velocity outputs. The sensor arrangement allows automatic accommodation of two failures; a third failure can be tolerated provided it can be determined. The navigation system also includes redundant power supplies, built-in test-equipment (BITE) circuits for failure detection, and software which provides for navigation, redundancy management, and automatic calibration and alignment.

Mcpherson, B. W.↗

Multichannel temperature controller for hot air solar house

This paper describes an electronic controller that is optimized to operate a hot air solar system. Thermal information is obtained from copper constantan thermocouples and a wall-type thermostat. The signals from the thermocouples are processed through a single amplifier using a multiplexing scheme. The multiplexing reduces the component count and automatically calibrates the thermocouple amplifier. The processed signals connect to some simple logic that selects one of the four operating modes. This simple, inexpensive, and reliable scheme is well suited to control hot air solar systems.

Currie, J. R.↗

Miniature Remote Deadweight Calibrator

Miniature, computer-controlled deadweight calibrator developed to calibrate remotely force transducer located in cryogenic chamber. Used with microcomputer, calibration system automatically applies deadweight loads to skin-friction balance, records and reduces data, and prints out results. Actuator controller and interlocking-weight system key elements in precise, automatic transducer calibrator. Designed for full-scale load of 1,000 mg. Concept extended to accommodate other full-scale load ranges.

Supplee, Frank H., Jr.↗

Radar-Data-Processing System

Report describes radar data system at NASA Western Aeronautical Test Range. System provides real-time and recorded data about flightpaths of research aircraft and Space Shuttle. Called RADATS, processes data from three radars simultaneously; interacts with system operator; enhances data by introducing corrections and smoothing; controls range, azimuth, and elevation of radars; and automatically calibrates itself before and after missions. Software classified into three kinds of programs: utility, real-time, and calibration. Equipment exhibited exceptional reliability. Software matured to become virtually trouble-free.

Anderson, Karl F.↗

Fundamental study on gas monitoring in CELSS

A mass spectrometer and computer system was developed for conducting a fundamental study on gas monitoring in a Controlled Ecological Life Support System. Respiration and metabolism of the hamster and photosynthesis of the Spirulina were measured in a combination system consisting of a hamster chamber and a Spirulina cultivator. They are connected through a membrane gas exchanger. Some technical problems were examined. In the mass spectrometric gas monitoring, a simultaneous multisample measurement was developed by employing a rotating exchange valve. Long term precise measurement was obtained by employing an automatic calibration system. The membrane gas sampling probe proved to be useful for long term measurement. The cultivation rate of the Spirulina was effectively changed by controlling CO2 and light supply. The experimental results are helpful for improving the hamster-spirulina system.

Nishi, I.↗

A prototype gas exchange monitor for exercise stress testing aboard NASA Space Station

This paper describes an easy-to-use monitor developed to track the weightlessness deconditioning aboard the NASA Space Station, together with the results of testing of a prototype instrument. The monitor measures the O2 uptake and CO2 production, and calculates the maximum O2 uptake and anaerobic threshold during an exercise stress test. The system uses two flowmeters in series to achieve a completely automatic calibration, and uses breath-by-breath compensation for sample line-transport delay. The monitor was evaluated using two laboratory methods and was shown to be accurate. The system's block diagram and the bench test setup diagram are included.

Orr, Joseph A.↗

Programmable Multiple-Ramped-Voltage Power Supply

Ramp waveforms range up to 2,000 V. Laboratory high-voltage power-supply system puts out variety of stable voltages programmed to remain fixed with respect to ground or float with respect to ramp waveform. Measures voltages it produces with high resolution; automatically calibrates, zeroes, and configures itself; and produces variety of input/output signals for use with other instruments. Developed for use with ultraviolet spectrometer. Also applicable to control of electron guns in general and to operation of such diverse equipment used in measuring scattering cross sections of subatomic particles and in industrial electron-beam welders.

Ajello, Joseph M.↗

Advanced Active-Magnetic-Bearing Thrust-Measurement System

An advanced thrust-measurement system utilizes active magnetic bearings to both (1) levitate a floating frame in all six degrees of freedom and (2) measure the levitation forces between the floating frame and a grounded frame. This system was developed for original use in measuring the thrust exerted by a rocket engine mounted on the floating frame, but can just as well be used in other force-measurement applications. This system offers several advantages over prior thrust-measurement systems based on mechanical support by flexures and/or load cells: The system includes multiple active magnetic bearings for each degree of freedom, so that by selective use of one, some, or all of these bearings, it is possible to test a given article over a wide force range in the same fixture, eliminating the need to transfer the article to different test fixtures to obtain the benefit of full-scale accuracy of different force-measurement devices for different force ranges. Like other active magnetic bearings, the active magnetic bearings of this system include closed-loop control subsystems, through which the stiffness and damping characteristics of the magnetic bearings can be modified electronically. The design of the system minimizes or eliminates cross-axis force-measurement errors. The active magnetic bearings are configured to provide support against movement along all three orthogonal Cartesian axes, and such that the support along a given axis does not produce force along any other axis. Moreover, by eliminating the need for such mechanical connections as flexures used in prior thrust-measurement systems, magnetic levitation of the floating frame eliminates what would otherwise be major sources of cross-axis forces and the associated measurement errors. Overall, relative to prior mechanical-support thrust-measurement systems, this system offers greater versatility for adaptation to a variety of test conditions and requirements. The basic idea of most prior active-magnetic-bearing force-measurement systems is to calculate levitation forces on the basis of simple proportionalities between changes in those forces and changes in feedback-controlled currents applied to levitating electromagnetic coils. In the prior systems, the effects of gap lengths on fringing magnetic fields and the concomitant effects on magnetic forces were neglected. In the present system, the control subsystems of the active magnetic bearings are coupled with a computer-based automatic calibration system running special-purpose software wherein gap-length-dependent fringing factors are applied to current and magnetic-flux-based force equations and combined with a multipoint calibration method to obtain greater accuracy.

Imlach, Joseph↗

An Operationally Based Vision Assessment Simulator for Domes

The Operational Based Vision Assessment (OBVA) simulator was designed and built by NASA and the United States Air Force (USAF) to provide the Air Force School of Aerospace Medicine (USAFSAM) with a scientific testing laboratory to study human vision and testing standards in an operationally relevant environment. This paper describes the general design objectives and implementation characteristics of the simulator visual system being created to meet these requirements. A key design objective for the OBVA research simulator is to develop a real-time computer image generator (IG) and display subsystem that can display and update at 120 frame s per second (design target), or at a minimum, 60 frames per second, with minimal transport delay using commercial off-the-shelf (COTS) technology. There are three key parts of the OBVA simulator that are described in this paper: i) the real-time computer image generator, ii) the various COTS technology used to construct the simulator, and iii) the spherical dome display and real-time distortion correction subsystem. We describe the various issues, possible COTS solutions, and remaining problem areas identified by NASA and the USAF while designing and building the simulator for future vision research. We also describe the critically important relationship of the physical display components including distortion correction for the dome consistent with an objective of minimizing latency in the system. The performance of the automatic calibration system used in the dome is also described. Various recommendations for possible future implementations shall also be discussed.

Archdeacon, John↗

A Description of the Development, Capabilities, and Operational Status of the Test SLATE Data Acquisition System at the National Transonic Facility

The paper will present a brief background of the previous data acquisition system at the National Transonic Facility (NTF) and the reasoning and goals behind the upgrade to the current Test SLATE (Test Software Laboratory and Automated Testing Environments) data acquisition system. The components, performance characteristics, and layout of the Test SLATE system within the NTF control room will be discussed. The development, testing, and integration of Test SLATE within NTF operations will be detailed. The operational capabilities of the system will be outlined including: test setup, instrumentation calibration, automatic test sequencer setup, data recording, communication between data and facility control systems, real time display monitoring, and data reduction. The current operational status of the Test SLATE system and its performance during recent NTF testing will be highlighted including high-speed, frame-by-frame data acquisition with conditional sampling post-processing applied. The paper concludes with current development work on the system including the capability for real-time conditional sampling during data acquisition and further efficiency enhancements to the wind tunnel testing process.

Cramer, Christopher J.↗

Automatic releveling of calibration stands for wind tunnel force and moment measurement instrumentation

Wind tunnel force and moment measuring instrumentation at NASA LaRC are calibrated by applying NIST certified dead loads, to generate forces and moments in three orthogonal axes, in twenty five percent increments, up to full-load and down to no-load in a nine point continuous procedure, using specially built calibration stands. The measuring instruments deflect upon the application of loads. These deflections must be cancelled to minimize loading interactions. The older calibration stands, integrated with AC induction motors, or DC motors, have provisions for manually releveling the loading point after each load. A newer stand, with integrated DC stepper motors, relevels automatically under software control. It was proposed to extend automation to the old stands. An algorithm to control the unwieldy induction motors to relevel a calibration stand, to within two arcseconds of horizontal direction automatically, was developed. The system developed uses coasting prediction and load adaptation in a general type robust stability control configuration with noncoincidental feedback. Automatic releveling cuts the releveling time to approximately half of the time required to do it manually. The principal constraint for shorter times is the time constant of the angular position feedback transducer.

Perazza, Manuel Rodriguez↗

Development report: Automatic System Test and Calibration (ASTAC) equipment

A microcomputer based automatic test system was developed for the daily performance monitoring of wind energy system time domain (WEST) analyzer. The test system consists of a microprocessor based controller and hybrid interface unit which are used for inputing prescribed test signals into all WEST subsystems and for monitoring WEST responses to these signals. Performance is compared to theoretically correct performance levels calculated off line on a large general purpose digital computer. Results are displayed on a cathode ray tube or are available from a line printer. Excessive drift and/or lack of repeatability of the high speed analog sections within WEST is easily detected and the malfunctioning hardware identified using this system.

Thoren, R. J.↗

Structural stereopsis - Potential for automatic stereo camera calibration

The paper describes the use of extended edge features as a source of primitives for structural stereopsis and considers the design of a system for autonomous camera calibration. It is shown that the structural approach permits greater use of spatial relational constraints, eliminating the coarse-to-fine tracking of point-based algorithms. Experimental results concerning matching and calibration on real images using Laplacian-of-Gaussian contour fragments as primitives in structural stereopsis are presented, and results in graph-theoretic representation and inexact matches, analytical photogrammetry, and other computer vision and image analysis problem domains are examined. Such a system might be used in aerial photogrammetry and cartography, and robotic vision systems; however, the system is still very much under development.

Boyer, Kim L.↗