Search NASA⌕ Search

SEARCH · Search NASA

Results for “balance of system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Comparative Life Cycle Analysis of Scalable Single-Junction and Tandem Perovskite Solar Cell (PSC) Systems

Efficient, low-cost solar cells based upon perovskites have the potential to transform the US and global energy portfolio and improve energy security if they can be manufactured in an environmentally sustainable manner. However, previous life cycle analyses (LCA) of perovskite solar cells (PSC) used lab recipes to project the environmental impact of industrial PSC production – using materials and processes that may not be representative of industrial productions due to high material waste and complex synthesis – and such studies were limited to a few single-junction technologies. Thus, the goal of this project was threefold: a) to review the most promising for industrial production single-junction and tandem PSC technologies, b) to build life-cycle materials inventories that reflect scalable production of these technologies, and c) to conduct comprehensive life-cycle analysis of these technologies and compare their environmental impact with those of established commercial technologies. In response, this project identified challenges for fabrication transitioning from laboratory to sustainable industrial production, developed life-cycle inventory (LCI) data for scaling to industrial production four promising single-junction and three tandem PSC systems and produced life-cycle-investigations using, as metrics, a complete spectrum of energy, environmental and ecological impact indicators. Special focus was given to the use of lead, silver and indium in PSC. The project used the Life Cycle Assessment (LCA) methodology as standardized by the Society of Environmental Toxicology and Chemistry (SETAC), ISO standards 14040 and 14044, and the International Energy Agency PVPS Task 12 LCA guidelines. LCA allows the calculation of a number of energy and environmental and impact categories, including energy cumulative energy demand (CED), global warming potential (GWP), human toxicity potential (HTP), eco-toxicity potential (ETP), abiotic resource depletion potential (ADP), acidification potential (AP), ozone depletion potential (ODP), photochemical oxidation potential (POP), eutrophication potential (EP). In addition to those, we calculated the Energy Pay-Back Time (EPBT) and the Energy Return On Investment (EROI). We provide LCA impacts for complete perovskite PV systems – including balance of system components – installed at three irradiation levels and considering reference and future potential module efficiencies. Finally, a sensitivity analysis on perovskite lifetime has been performed, considering 10, 20 and 30 years. Contribution analysis of the impacts of each material and layer of PSC shows, that the use of Pb in metalorganic PSC does not result in significant environmental impacts as the major contributions to environmental indicators arise from the use of Ag and encapsulation materials. Solution-based PSC manufacturing was found to be less impactful to the environment than vapor-based fabrication, and roll-to-roll (RtR) printing uses less energy and generates the lowest emissions. PSC produced with RtR manufacturing could reach the same Energy Return on Energy Investment (EROI) as that of crystalline-Si PV within 12 years of life, whereas the most energy demanding spray coating on rigid substrates, would require a 20-yr life to match the EROI of 30-yr lasting silicon PV. This work lays the foundation for sustainability investigations in a comparative context of large-scale production and deployment of PSC. The results of this project have the potential to have a significant impact on the future of PV manufacturing, by providing industry, policy-makers, and academia with insights necessary to choose which, if any, lead-based solar cell life cycles are environmentally sustainable.

14 SOLAR ENERGY↗

Fault-Tolerant Deep Learning Cache with Hash Ring for Load Balancing in HPC Systems

Large-scale DL on HPC systems like Frontier and Summit uses distributed node-local caching to address scalability and performance challenges. However, as these systems grow more complex, the risk of node failures increases, and current caching approaches lack fault tolerance, jeopardizing large-scale training jobs. We analyzed six months of SLURM job logs from Frontier and found that over 30% of jobs failed after an average of 75 minutes. To address this, we propose fault-tolerance strategies that recache data lost from failed nodes using a hash ring technique for balanced data recaching in the distributed node-local caching, reducing reliance on the PFS. Our extensive evaluations on Frontier showed that the hash ring-based recaching approach reduced training time by approximately 25% compared to the approach that redirects I/O to the PFS after node failures and demonstrated effective load balancing of training data across nodes.

Lee, Seoyeong↗

Flow balancing devices, methods, and systems

The disclosed subject matter relates to extracorporeal blood processing or other processing of fluids. Volumetric fluid balance, a required element of many such processes, may be achieved with multiple pumps or other proportioning or balancing devices which are to some extent independent of each other. This need may arise in treatments that involve multiple fluids. Safe and secure mechanisms to ensure fluid balance in such systems are described.

Burbank, Jeffrey H.↗

Generator Interconnection Costs to the Transmission System in non-ISO Balancing Authorities [Slides]

Electric transmission system operators—including Independent System Operators (ISOs), Regional Transmission Organizations (RTOs), and utilities—require proposed power plants to undergo a series of interconnection studies before connecting to the grid. These studies assess what transmission upgrades or new infrastructure may be necessary and assign the associated costs to the project. Lawrence Berkeley National Laboratory has compiled, aggregated, and cleaned interconnection cost data, originally for ISOs/RTOs, and now for five non-ISO Balancing Authorities: PacifiCorp, Bonneville Power Authority, Duke Energy Progress, Duke Energy Carolinas and Duke Energy Florida. Insufficient transparency in interconnection cost data may contribute to rapidly expanding interconnection queues, with active queue capacities tripling between 2020 and 2024 in the studied BAs. Most projects withdraw after receiving high interconnection cost estimates. Interconnection costs have increased since the early 2000s, with average costs for "complete" projects reaching $194/kW between 2018 and 2024. Active queue projects and withdrawn projects incur substantially higher costs, primarily due to rising network upgrade costs. Recent interconnection costs in non-ISO balancing authorities are higher than in ISO regions, potentially due to a greater willingness to pay among developers. Utility-scale solar, wind, and storage projects have interconnection costs that exceed those for natural gas. However, when focusing on projects that do not withdraw from the queue, the interconnection costs for these technologies are more similar to natural gas projects. Other key findings include: (1) Larger generation projects benefit from lower proportional interconnection costs, (2) capacity transmission service (NRIS) often requires additional network investments, and (3) projects with high network upgrade costs are often clustered geographically. The dataset includes results from 2,104 interconnection studies conducted between 2000 and 2024, covering projects that are operational, withdrawn, or still progressing through the study process. The Excel file contains (a) the complete project-level interconnection cost dataset, and (b) seven additional tabs summarizing cost metrics across dimensions such as time, market structure, cost category (point of interconnection vs. broader network upgrades), fuel type, service type (ERIS vs. NRIS), generator size, and geography.

24 POWER TRANSMISSION AND DISTRIBUTION↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks: Q1 2021

Based on our bottom-up modeling, the Q1 2021 PV and energy storage cost benchmarks are: $\$2.65$ per watt DC (WDC) (or $\$3.05$/WAC) for residential PV systems, 1.56/WDC (or $\$1.79$/WAC) for commercial rooftop PV systems, $\$1.64$/WDC (or $\$1.88$/WAC) for commercial ground-mount PV systems, $\$0.83$/WDC (or $\$1.13$/WAC) for fixed-tilt utility-scale PV systems, $\$0.89$/WDC (or $\$1.20$/WAC) for one-axis-tracking utility-scale PV systems, $\$30,326$-$\$33,618$ for a 7.15-kWDC residential PV system with 5 kW/12.5 kWh nameplate of storage, $\$2.04$ - $\$2.10$ million for a 1-MWDC commercial ground-mount PV system colocated with 600 kW/2.4 MWhusable of storage, $\$166$ - $\$167$ million for a 100-MWDC one-axis tracker PV system colocated with 60 MW/240 MWhusable of storage. Between 2020 and 2021, there were 3.3% ($\$0.0$9/W), 10.7% ($\$0.19$/W), and 12.3% ($\$0.13$/W) reductions (in 2020 USD) in the residential, commercial rooftop, and utility-scale (one-axis) PV system cost benchmarks respectively. Balance of system (BOS) costs have either increased or remained flat across sectors, year-on-year, unlike in previous benchmark reports, which generally have reported declining BOS costs. The increase in BOS cost has been offset by a 17% reduction in module cost. Overall, modeled PV installed costs across the three sectors have declined compared to our Q1 2020 system costs.

14 SOLAR ENERGY↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters: Preprint

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Representing DC-Coupled PV+Battery Hybrids in a Capacity Expansion Model

Recent technology cost and performance improvements and the federal investment tax credit (ITC) have driven growing interest in coupling solar photovoltaic (PV) and battery systems. Combining these technologies into co-located or hybridized PV+battery systems has the potential to lower costs and increase energy output relative to multiple independent systems. In this work, we provide an overview of PV+battery systems and demonstrate methods for incorporating them into NREL’s Regional Energy Deployment System (ReEDS) capacity expansion model. Although the methods are applied to a specific model, we anticipate that the approaches used here can be useful for informing PV+battery method development for other capacity expansion models. The implemented method relies heavily on the native representations of PV and battery technologies; therefore, the focus of this work is on capturing and parameterizing the interactions between them for a configuration in which the PV and battery technologies share a single bi-directional inverter. This work also demonstrates the impacts of including PV+battery systems in the ReEDS optimization for the conterminous United States through 2050. In particular, we perform parametric sensitivities for input assumptions that are uncertain and expected to influence PV+battery deployment levels, including (a) the cost of PV+battery systems relative to independent PV and battery systems, (b) the battery component’s qualification for the ITC, and (c) future cost trajectories for PV and battery systems. We find that PV+battery deployment could occur throughout the conterminous United States if there are cost savings associated with DC coupling PV and battery technologies. If even modest (5%) cost savings can be achieved (through a shared inverter and balance-of-system costs), then approximately one-third of utility-scale PV deployment through 2050 adopts the DC-coupled hybrid configuration, resulting in total PV+battery deployment that exceeds the magnitude of PV+battery projects in U.S. interconnection queues in 2020. If greater cost savings can be achieved through DC coupling (e.g., due to a growing amount of shared balance-of-system costs, reduced financial risk, or modularity) or more rapid cost and performance improvements are realized for PV and battery technologies, then total PV+battery deployment and the share of PV and battery deployment that adopts the hybrid configuration grows (to >50%). In all cases, growing PV+battery deployment primarily displaces independent PV and battery technologies, indicating the strong competition between the hybrid and independent configurations comprising technologies with similar performance characteristics.

14 SOLAR ENERGY↗

LCOE Design Optimization Using Genetic Algorithm with Improved Component Models for Medium-Voltage Transformerless PV Inverters

For real-world installations of photovoltaic and other renewable energy resources, the critical design metric is the levelized cost of energy (LCOE); however, many power electronics design optimizations are performed with efficiency and power density as the primary design goals. Recent work has shown that a new LCOE-focused optimization approach can yield improved system designs balancing cost and energy generation. This paper expands the LCOE optimization approach by considering comprehensive optimization parameters, adding new modeling of inductor cost, extending the semiconductor model to include effects of losses on housing cost, and implementing a genetic algorithm to improve computation efficiency.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Europe’s energy policy based on large-scale use of renewables most likely will require supplemental power supplies to balance their electrical power systems

Political decisions toward an increased role for renewable energy sources (wind & solar) in Europe will have an impact on the functioning of the electrical power systems that will have to be offset due to the inherent intermittent nature of renewable sources. The offset can be accomplished either through increasing non-renewable energy supply and production from other means, including purchasing Russian piped natural gas and LNG, or decreasing demand by curtailing power consumption. Europe likely will also need increased energy supplies to cover reduced gas production in the North Sea and Netherlands. Also, expected disconnection of Baltic states from the BRELL (Belarus-Russia-EstoniaLatvia-Lithuania) grid will force these countries to acquire electricity from Europe, resulting in increased demands on the European power grid that will require additional capacity to offset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

2019 Energy Storage Pricing Survey

Since grid energy storage is still evolving rapidly, it is often difficult to obtain project specific capital costs for various energy storage technologies. This information is necessary to evaluate the profitability of the facility, as well as comparing different energy storage technology options. The goal of this report is to summarize energy storage capital costs that were obtained from industry pricing surveys. The methodology breaks down the cost of an energy storage system into the following component categories: the storage module; the balance of system; the power conversion system; the energy management system; and the engineering, procurement, and construction costs. By evaluating each of the different component costs separately, a synthetic system cost can be developed that provides internal pricing consistency between different project sizes using the same technology, as well as between different technologies that utilize similar components.

25 ENERGY STORAGE↗