Search NASA⌕ Search

SEARCH · Search NASA

Results for “baselining”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Engineering Analysis Baseline Model Requirements

The purpose of this document is to set requirements for the development, documentation, implementation, and maintenance of engineering analysis baseline models used by the Advanced Engineering and Analysis group to model and simulate systems. The intended audience of this document is the Engineering Technology and Design division Advanced Engineering and Analysis group—in particular the baseline model owners and users—and the Group Leaders and members of the Systems Engineering groups. Section 1 presents a discussion of general concepts related to engineering analysis models and baseline models, including definitions of common terms used in this requirements document. It also presents the purpose and intentions of creating and using baseline models and exposes some underlying assumptions about what baseline models are supposed to be. Section 2 presents requirements on the general categories of: the Advanced Engineering and Analysis Group Leader and the baseline model owner; parts, materials, and load cases; the process of generating and using the model; and how the baseline model will be stored, maintained, and documented. This document presents requirements on the baseline model as well as some aspects of the development process and the people responsible for the development; it does not address how the results of simulations utilizing these models will be used to make assessments

42 ENGINEERING↗

Assessment of Baseline Monitoring Data for the Remote-Handled Low-Level Waste Disposal Facility at Idaho National Laboratory

The purpose of this document is to summarize environmental monitoring data collected at the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility during the first four years of facility operations (FY 2019 through FY 2022). This summary provides a “baseline” condition for the facility, which can be used to distinguish contaminant releases from the RHLLW Disposal Facility from pre existing contamination as well as potential future releases from other sources (i.e., upgradient aquifer sources), as specified in the facility monitoring plan. Sufficient data has been collected over the first four years of operation of the RHLLW Disposal Facility to establish baseline conditions for future compliance monitoring of aquifer wells and performance monitoring of vadose zone lysimeters. Except for seven elevated tritium measurements from lysimeter HFEF-South believed to have been impacted by waste disposals, all data was deemed appropriate for establishing baseline concentrations. Monitoring of the aquifer detected indicator analytes gross alpha and gross beta and target analytes tritium and C-14. There were a few C-14 detections prior to an increase in the required detection level (RDL) after the first round of sampling. I-129 and Tc-99 were not detected above RDLs in aquifer samples. Lysimeter samples detected indicator analytes gross alpha and gross beta and target analyte tritium. Target analytes C-14, I-129, and Tc-99 were not detected above RDLs in lysimeter samples. Except for tritium, baseline concentrations of indicator and target analytes measured during the first four years of RHLLW facility operations are expected to represent conditions through the expected 20 year operating period of the facility. Elevated tritium in the aquifer, a result of past discharges of tritium at upgradient facilities, showed a decline over the first four years of operations, and levels are expected to continue to decline with time as a result of dilution and decay. Current tritium levels in lysimeter samples may be elevated due to tritium in the water applied during construction and infiltration testing of the facility. As a result, tritium concentrations in lysimeters may decline with time as a result of dilution and decay. Statistical measures (i.e., mean, standard deviation, and 99% upper confidence level [UCL]) were calculated for all detected analytes using the four years of concentration data. These measures will be used to evaluate future monitoring results and to demonstrate the facility is performing, or not performing, as established in the facility performance assessment (PA). Future monitoring results will also be combined with the baseline data in this report to further establish temporal trends and natural variability in the measurements. Based on the data collected during the baseline period, it is recommended the gross alpha action level for performance monitoring increase from 10 to 20 pCi/L due to several baseline measurements exceeding the preliminary action level of 10. An action level of 20 pCi/L is slightly greater than the 99% UCL, is protective of the aquifer, and would reduce unnecessary sampling. It is also recommended that tritium be added to the lysimeter analyte list for post-baseline period monitoring. Tritium, while not a dose concern, is a good tracer that can provide valuable information on water flow in and around the RHLLW Disposal Facility. Recommendations for a tritium action level are provided if considered necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Short baseline phase delay interferometry

The high precision of the phase delay data type allows angular navigation accuracy on relatively short baselines to compete with the angular accuracy achieved with long baseline group delay measurements. Differential phase delay observations of close quasar pairs on both a 5.9-km baseline (DSS 12-DSS 13) and a 253-km baseline (DSS 13-Owens Valley Radio Observatory) have been performed to study the potential navigational precision and accuracy of the short baseline interferometry. As a first step toward demonstration of a connected element system at Goldstone, the DSS 12-DSS 13 baseline was operated coherently, distributing a common frequency reference via a recently installed fiber optic cable. The observed phase delay residuals of about 10 psec or less on both baselines appear to be dominated by short term troposphere fluctuations, and correspond to navigational accuracies of well below 50 nrad for the 253-km baseline. Additional experiments will be required to probe the full range of systematic errors.

Edwards, C. D.↗

The Spring 1985 high precision baseline test of the JPL GPS-based geodetic system

The Spring 1985 High Precision Baseline Test (HPBT) was conducted. The HPBT was designed to meet a number of objectives. Foremost among these was the demonstration of a level of accuracy of 1 to 2:10 to the 7th power, or better, for baselines ranging in length up to several hundred kilometers. These objectives were all met with a high degree of success, with respect to the demonstration of system accuracy in particular. The results from six baselines ranging in length from 70 to 729 km were examined for repeatability and, in the case of three baselines, were compared to results from colocated VLBI systems. Repeatability was found to be 5:10 to the 8th power (RMS) for the north baseline coordinate, independent of baseline length, while for the east coordinate RMS repeatability was found to be larger than this by factors of 2 to 4. The GPS-based results were found to be in agreement with those from colocated VLBI measurements, when corrected for the physical separations of the VLBI and CPG antennas, at the level of 1 to 2:10 to the 7th power in all coordinates, independent of baseline length. The results for baseline repeatability are consistent with the current GPA error budget, but the GPS-VLBI intercomparisons disagree at a somewhat larger level than expected. It is hypothesized that these differences may result from errors in the local survey measurements used to correct for the separations of the GPS and VLBI antenna reference centers.

Davidson, John M.↗

Evaluation of current tropospheric mapping functions by Deep Space Network very long baseline interferometry

To compare the validity of current algorithms that map zenith tropospheric delay to arbitrary elevation angles, 10 different tropospheric mapping functions are used to analyze the current data base of Deep Space Network Mark 3 intercontinental very long baseline interferometric (VLBI) data. This analysis serves as a stringent test because of the high proportion of low-elevation observations necessitated by the extremely long baselines. Postfit delay and delay-rate residuals are examined, as well as the scatter of baseline lengths about the time-linear model that characterizes tectonic motion. Among the functions that utilize surface meteorological data as input parameters, the Lanyi 1984 mapping shows the best performance both for residuals and baselines, through the 1985 Davis function is statistically nearly identical. The next best performance is shown by the recent function of Niell, which is based on an examination of global atmospheric characteristics as a function of season and uses no weather data at the time of the measurements. The Niell function shows a slight improvement in residuals relative to Lanyi, but also an increase in baseline scatter that is significant for the California-Spain baseline. Two variants of the Chao mapping function, as well as the Chao tables used with the interpolation algorithm employed in the Orbit Determination Program software, show substandard behavior for both VLBI residuals and baseline scatter. The length of the California-Australia baseline (10,600 km) in the VLBI solution can vary by as much as 5 to 10 cm for the 10 mapping functions.

Sovers, O. J.↗

Evaluation of the KOKEE12M/ONSA13NE Baseline as a KOKEE12M/WETTZ13S Backup

USNO's IERS Rapid Service/Prediction Center (RS/PC) uses the KOKEE12M/WETTZ13S (K2/Ws) baseline for its combination solutions. It would be useful for the RS/PC to be able to use backup baselines in case K2 or Ws is not available. While Ws was undergoing repair in late 2022 through early 2023, ONSA13NE (Oe) replaced Ws to provide immediate UT1 for IVS Analysis Center products but also to begin building a data set for the RS/PC to eventually use to ``characterize'' (assess and approve) the K2/Oe baseline for use in its solutions. The RS/PC needs 60 sessions to be able to characterize a baseline, and the data from the repair period provided 58 sessions, with three additional sessions being observed later. Here we evaluate the K2/Oe baseline to see if it is a viable candidate for submission to the RS/PC for characterization. We evaluate the K2/Oe baseline itself and also compare the K2/Oe baseline to the K2/Ws baseline.

VLBI↗

Spillover as a cause of bias in baseline evaluation methods for demand response programs

Prior research has shown load reduction estimates from residential event-driven demand response programs (e.g., Critical Peak Pricing)using X of the highest Y days with a weather adjustment method are the best performing within the class of currently used baseline methods. However, they are still biased relative to estimates produced from randomized control trials (RCTs), the unbiased “gold standard” evaluation method. In this paper we identify underlying factors that cause some of the bias found in one commonly used baseline method. Rather than simply quantifying bias, our research provides a deeper understanding of what causes the bias and thus can be used to develop more accurate methods that are not subject to these underlying factors. Previous studies have compared various baseline methods relative to each other; however, because all baseline methods are biased, it is impossible to determine the true bias that exists in them. We have access to a unique RCT dataset: the Sacramento Municipal Utility District's study of critical peak pricing. Our analysis of 23 event days over two summers allows us to identify the true bias on load reduction estimates by using the RCT estimates as the unbiased gold standard against which we compare the estimates from the baseline methods. We found that spillover of energy reductions, from hours targeted by a program onto other hours, is one underlying factor that is a major cause of bias in baseline methods. We discuss alternative baseline methods that may not be subject to this same bias.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extracting Baseline Electricity Usage Using Gradient Tree Boosting

To understand how specific interventions affect a process observed over time, we need to control for the other factors that influence outcomes. Such a model that captures all factors other than the one of interest is generally known as a baseline. In our study of how different pricing schemes affect residential electricity consumption, the baseline would need to capture the impact of outdoor temperature along with many other factors. In this work, we examine a number of different data mining techniques and demonstrate Gradient Tree Boosting (GTB) to be an effective method to build the baseline. We train GTB on data prior to the introduction of new pricing schemes, and apply the known temperature following the introduction of new pricing schemes to predict electricity usage with the expected temperature correction. Our experiments and analyses show that the baseline models generated by GTB capture the core characteristics over the two years with the new pricing schemes. In contrast to the majority of regression based techniques which fail to capture the lag between the peak of daily temperature and the peak of electricity usage, the GTB generated baselines are able to correctly capture the delay between the temperature peak and the electricity peak. Furthermore, subtracting this temperature-adjusted baseline from the observed electricity usage, we find that the resulting values are more amenable to interpretation, which demonstrates that the temperature-adjusted baseline is indeed effective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-G-BRA-16: Target Dose Comparison for Dynamic MLC Tracking and Mid- Ventilation Planning in Lung Radiotherapy Subject to Intrafractional Baseline Drifts

Purpose: Lung tumor motion during radiotherapy can be accounted for by expanded treatment margins, for example using a mid-ventilation planning approach, or by localizing the tumor in real-time and adapting the treatment beam with multileaf collimator (MLC) tracking. This study evaluates the effect of intrafractional changes in the average tumor position (baseline drifts) on these two treatment techniques. Methods: Lung stereotactic treatment plans (9-beam IMRT, 54Gy/3 fractions, mean treatment time: 9.63min) were generated for three patients: either for delivery with MLC tracking (isotropic GTV-to-PTV margin: 2.6mm) or planned with a mid-ventilation approach and delivered without online motion compensation (GTV-to-PTV margin: 4.4-6.3mm). Delivery to a breathing patient was simulated using DynaTrack, our in-house tracking and delivery software. Baseline drifts in cranial and posterior direction were simulated at a rate of 0.5, 1.0 or 1.5mm/min. For dose reconstruction, the corresponding 4DCT phase was selected for each time point of the delivery. Baseline drifts were accounted for by rigidly shifting the CT to ensure correct relative beam-to-target positioning. Afterwards, the doses delivered to each 4DCT phase were accumulated deformably on the mid-ventilation phase using research RayStation v4.6 and dose coverage of the GTV was evaluated. Results: When using the mid-ventilation planning approach, dose coverage of the tumor deteriorated substantially in the presence of baseline drifts. The reduction in D98% coverage of the GTV in a single fraction ranged from 0.4-1.2, 0.6-3.3 and 4.5-6.2Gy, respectively, for the different drift rates. With MLC tracking the GTV D98% coverage remained unchanged (+/− 0.1Gy) regardless of drift. Conclusion: Intrafractional baseline drifts reduce the tumor dose in treatments based on mid-ventilation planning. In rare, large target baseline drifts tumor dose coverage may drop below the prescription, potentially affecting clinical outcome in hypofractionated treatment protocols. Dynamic MLC tracking preserves tumor dose coverage even in the presence of extreme baseline drifts. We acknowledge financial and technical support of the MLC tracking research from Elekta AB. Research at ICR is supported by CRUK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR. MFF is supported by CRUK under Programme C33589/A19908.

60 APPLIED LIFE SCIENCES↗

Detection of atmospheric pressure loading using very long baseline interferometry measurements

Loading of the Earth by the temporal redistribution of global atmospheric mass is likely to displace the positions of geodetic monuments by tens of millimeters both vertically and horizontally. Estimates of these displacements are determined by convolving National Meteorological Center (NMC) global values of atmospheric surface pressure with Farrell's elastic Green's functions. An analysis of the distances between radio telescopes determined by very long baseline interferometry (VLBI) between 1984 and 1992 reveals that in many of the cases studied there is a significant contribution to baseline length change due to atmospheric pressure loading. Our analysis covers intersite distances of between 1000 and 10,000 km and is restricted to those baselines measured more than 100 times. Accounting for the load effects (after first removing a best fit slope) reduces the weighted root-mean-square (WRMS) scatter of the baseline length residuals on 11 of the 22 baselines investigated. The slight degradation observed in the WRMS scatter on the remaining baselines is largely consistent with the expected statistical fluctuations when a small correction is applied to a data set having a much larger random noise. The results from all baselines are consistent with approximately 60% of the computed pressure contribution being present in the VLBI length determinations. Site dependent coefficients determined by fitting local pressure to the theoretical radial displacement are found to reproduce the deformation caused by the regional pressure to within 25% for most inland sites. The coefficients are less reliable at near coastal and island stations.

Vandam, T. M.↗

Baseline Calibration of the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency, X-Band and P-Band, interferometric mapping radar flown on a Gulfstream II with a nominal flying altitude of 10000 and a swath width of 10 km on both left and right sides of the aircraft. The radar is designed to generate high resolution and high accuracy digital elevation maps both above and below the vegetation canopy. In order to generate the high accuracy digital elevations models it is necessary to have extremely precise knowledge of the interferometric baseline, approximately .1 mm for the X-band system and 3 mm for the P-band system. Baseline knowledge to this level of accuracy is achieved through a combination of active baseline measurement using a Laser Baseline Metrology System (LBMS) and baseline calibration using an accurately surveyed array of corner reflectors. In this paper, we describe the LBMS system used to measure the dynamic component of the interferometric baseline and the least squares procedure used to estimate all three components of the interferometric baseline based on differences between calculated and surveyed corner reflector locations.

Hensley, Scott↗

Testing Explanations of Short Baseline Neutrino Anomalies

The experimental observation of neutrino oscillations profoundly impacted the physics of neutrinos, from being well understood theoretically to requiring new physics beyond the standard model of particle physics. Indeed, the mystery of neutrino masses implies the presence of new particles never observed before, often called sterile neutrinos, as they would not undergo standard weak interactions. And while neutrino oscillation measurements entered the precision era, reaching percent-level precision, many experimental results show significant discrepancies with the standard model, at baselines much shorter than typical oscillation baselines, like LSND, MiniBooNE, gallium experiments, and reactor antineutrino measurements. These short baseline anomalies could be explained by the addition of a light sterile neutrino, with mass in the $1-10~\text{eV}$ range, however, in strong tension with many null experimental observations. Other explanations that rely on sterile neutrinos with masses in the $1-500~\text{MeV}$ could resolve the tension. Here we test both classes of models. On the one hand, we look for datasets collected at a short baseline which can constrain heavy sterile neutrino models. We find that the minimal model is fully constrained, but several extensions of this model could weaken the current constraint and be tested with current and future datasets. On the other hand, we test the presence of neutrino oscillations at short baselines, induced by a light sterile state, with the data collected by the MicroBooNE experiment, a liquid argon time projection chamber specifically designed to resolve the details of each neutrino interaction. We report null results from both analyses, further constraining the space of possible explanations for the short baseline anomalies. If new physics lies behind the short baseline anomaly puzzle, it is definitely not described by a simple model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the accuracy of energy baseline models for commercial buildings with occupancy data

More than 80% of energy is consumed during operation phase of a building's life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. To conclude, the results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Visual Systems Mapping to Improve Transparency and Comparability of Life Cycle Assessment Baseline Scenarios

Visual systems mapping is a systems engineering approach used to represent complex processes and interactions. This study evaluates its application for documenting assumptions in life cycle assessment (LCA) baseline scenarios. In LCA, the baseline or reference case represents the business as usual system against which changes in impacts (e.g., emissions) are assessed. These baseline assumptions are particularly influential in biomass LCAs, yet they often vary across studies due to regional context, system boundaries, and simplifying assumptions that are not consistently or transparently documented. As a result, key feedbacks, omitted processes, and boundary choices may remain unclear, limiting comparability across studies and weakening their usefulness for decision-making. This study examines whether visual systems mapping can improve the transparency and comparability of biomass LCA baseline scenarios. A case study of five published biomass-related LCAs were reviewed, and their baseline scenarios were translated into visual system maps to identify included processes, omitted components, and underlying assumptions. The analysis demonstrates that visual systems mapping can make baseline assumptions more explicit, highlight excluded dynamics, and improve documentation of system boundaries. Based on these findings, the study recommends the use of visual systems mapping alongside open data repositories and reproducible workflows to support greater transparency, reproducibility, and comparability in LCAs. These improvements can strengthen the role of LCAs in informing decisions related to sustainable biomass systems.

Davis, Maggie [ORNL] (ORCID:0000000181319328)↗

Prognosticating Survival in Hepatocellular Carcinoma with Elevated Baseline Alpha-fetoprotein Treated with Radioembolization Using a Novel Laboratory Scoring System: Initial Development and Validation

Aims: To investigate laboratory parameters as predictors of overall survival (OS) for hepatocellular carcinoma (HCC) treated with radioembolization and develop/validate a scoring system. Methods: With IRB approval, we included all patients with baseline alpha-fetoprotein (AFP) > 100 ng/dL from our prospectively acquired HCC radioembolization database. Neutrophil–lymphocyte ratio, albumin–bilirubin (ALBI), and AFP were measured at baseline and at 1-, 3-, and 6-month post-radioembolization Landmarks. OS was assessed from these Landmarks. Univariate/multivariate analyses were performed to evaluate OS predictability of these parameters. Baseline Imaging, Laboratory, and Combination scoring systems were developed. Developing/validating groups were created to investigate/validate the score’s OS predictability. Time-dependent receiver operating characteristics (ROC) were evaluated. Patients were stratified into groups I, II, and III by using 25th and 75th percentile cutoffs according to change in Laboratory Score from baseline. Results: 345/401 (86%), 238/401 (59%), and 167/401 (42%) patients had laboratory parameters available at the 1-, 3-, and 6-month Landmarks, respectively. ALBI and AFP were significant OS prognosticators at all Landmarks. The Laboratory Score [ALBI + (0.3 × LnAFP)] was developed/internally validated to predict OS from these Landmarks. Areas under the curve of time-dependent ROCs of the Baseline Imaging vs. Laboratory scores in predicting patient OS post 3 and 6 months Landmarks were 0.56 versus 0.82 and 0.57 versus 0.77, respectively. OS differences in groups I, II, and III according to change in Laboratory Score from baseline were significant (p < 0.001). Conclusions: Post-radioembolization AFP and ALBI scores were significant OS prognosticators. A decrease in post-therapeutic Laboratory Score, which combines AFP and ALBI, correlates with an improved OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Large short-baseline {nu}{sub {mu}} disappearance

We analyze the LSND, KARMEN, and MiniBooNE data on short-baseline {nu}{sub {mu}{yields}{nu}e} oscillations and the data on short-baseline {nu}{sub e} disappearance obtained in the Bugey-3 and CHOOZ reactor experiments in the framework of 3+1 antineutrino mixing, taking into account the MINOS observation of long-baseline {nu}{sub {mu}} disappearance and the KamLAND observation of very-long-baseline {nu}{sub e} disappearance. We show that the fit of the data implies that the short-baseline disappearance of {nu}{sub {mu}} is relatively large. We obtain a prediction of an effective amplitude sin{sup 2}2{theta}{sub {mu}{mu}} > or approx. 0.1 for short-baseline {nu}{sub {mu}} disappearance generated by 0.2 < or approx. {Delta}m{sup 2} < or approx. 1 eV{sup 2}, which could be measured in future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗