Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

White Paper on Case Study of Safe Installation of Second-Life Energy Storage System

This technical report provides for a case study for the safe installation of a second-life, or repurposed, battery, that has been reconfigured for use as a stationary energy storage systems (ESS). Driven by legislative requirements such as California Senate Bill 615 and projections that retired EV batteries could meet a substantial portion of U.S. grid ESS needs beginning in 2035, the repurposing of EV batteries is anticipated to grow significantly. However, safety concerns arise from the effects of aging, unknown prior usage history, and changes in thermal runaway behavior, which may increase failure risks compared to new batteries. NFPA 855, the predominant U.S. standard for ESS installation, mandates that second-life batteries meet all requirements for new batteries, with repurposers complying with UL 1974 in addition to obtaining UL 9540 and UL 1973 listings. These are certifications that few repurposers have achieved and represent a regulatory barrier to entry for the market as a whole.

47 OTHER INSTRUMENTATION↗

Investigation on the explosion dynamics of large-format lithium-ion pouch cells

Explosion is the most extreme case of thermal runaway of lithium-ion (Li-ion) batteries. In this study, explosion dynamics of large-format Li-ion cells are investigated experimentally and numerically. Overcharge-to-explosion tests are conducted on 40 Ah Li-ion cells with Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 cathode. Based on the explosion physics, shockwave and detonation models are used to characterize the shock effect of the cell explosion and evaluate the explosion equivalent. Von Neumann peak is observed on the pressure curves, and the shockwave velocity is supersonic at this time; the unwrinkled spherical flame phenomenon observed in the experiment indicates that it is detonation. Additionally, a geometric model is established based on the real testing scenario, and the explosion behavior is numerically studied. The characteristics of the explosion dynamics process are interpreted and the propagation mechanism of the shockwave are revealed; the deflagration to detonation transition (DDT) phenomenon in this process is caused by the formation of “hot spots”, and the explosion of the cells eventually turns into stable combustion. Here this study fills the gap in the research on thermal runaway of Li-ion cells, especially in the extreme cases of fire and explosion, and provide useful guidance for battery safety.

42 ENGINEERING↗

In Situ Synthesis of Phosphate-Based CelloMOF as a Promising Separator for Li–Ion Batteries

Nowadays, battery separators play a critical role in determining the sustainability, electrochemical efficiency, and safety of lithium-ion batteries (LIBs). In this contribution, we developed fire-resistant composite membranes called CelloMOF by in situ grafting of metal-organic framework, ZIF-67, onto phosphorylated cellulose nanofibers (P-CNFs) followed by a vacuum filtration process akin to papermaking. The hybrid ZIF-67@P-CNF membrane exhibits superior properties than a polyolefin-based commercial separator (CS) in terms of enhanced thermal and dimensional stability, flame-retardant properties, better surface wettability, and improved electrolyte uptake. Thermal dimensional stability tests revealed that the ZIF-67@P-CNF separator maintained its structure even at 200 °C, whereas CS suffered severe shrinkage, potentially leading to internal short circuits. Combustion tests showed a peak heat release rate (PHRR) of 34.5 W/g and a total heat release (THR) of 1.61 kJ/g for ZIF-67@P-CNF, significantly lower than the PHRR (1111.82 W/g) and THR (40.89 kJ/g) of CS. The composite separator also demonstrated significantly improved wettability, with a contact angle of 32 ± 1.04°, compared to 92 ± 1.07° for CS, highlighting its hydrophilic nature. Electrochemical evaluations in LiFePO 4 /Li half-cells indicated a higher discharge capacity of 149 mA h g -1 at 0.2 C and superior capacity retention of 86% after 50 cycles, outperforming CS (145 mA h g -1 and 84%, respectively). In conclusion, these results underscore the potential of the ZIF-67@P-CNF membrane to advance safe, high-performance LIBs by addressing critical challenges in thermal stability, flame retardancy, and electrolyte compatibility.

ZIF-67↗

NEXT Generation Energy Technologies for Connected and Automated On-Road Vehicles (NEXTCAR Phase I & II)

The Ohio State University’s ARPA-E NEXTCAR project was a multi-phase, multi-year research, development, and demonstration program focused on improving the energy efficiency of connected and automated vehicles (CAVs). The team developed and validated advanced vehicle motion and powertrain control algorithms that coordinate propulsion and automation systems to optimize energy use. Key technologies included Dynamic Skip Fire engine control, predictive eco-driving functions such as Eco-Approach and Departure (Eco-AND) and Eco-Adaptive Cruise Control (Eco-ACC), and powertrain-agnostic optimization frameworks for hybrid, plug-in hybrid, and battery electric vehicles. The project successfully demonstrated up to 30% energy-efficiency improvement during real-world testing at the Transportation Research Center and the American Center for Mobility. The outcomes provide a foundation for scalable, cost-effective deployment of energy-optimized CAV technologies across the automotive industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D Ion-Conducting, Scalable, and Mechanically Reinforced Ceramic Film for High Voltage Solid-State Batteries

Concerning the safety aspects of Li+ ion batteries, an epoxy-reinforced thin ceramic film (ERTCF) is prepared by firing and sintering a slurry-casted composite powder film. The ERTCF is composed of Li + ion conduction channels and is made of high amounts of sintered ceramic Li 1+ x Ti 2-x Al x (PO 4 ) 3 (LATP) and epoxy polymer with enhanced mechanical properties for solid-state batteries. The two- and three-dimensional characterizations are conducted not only for showing continuous Li+ ion channels thorough LATP ceramic channels with over 10-4 S cm-1 of ionic conductivity but also to investigate small amounts of epoxy polymer with enhanced mechanical properties. Solid-state Li + ion cells are fabricated using the ERTCF and they show initial charge–discharge capacities of 139/133 mAh g -1 . Furthermore, the scope of the ERTCF is expanded to high-voltage (>8 V) solid-state Li + ion batteries through a bipolar stacked cell design. Hence, it is expected that the present investigation will significantly contribute in the preparation of the next generation reinforced thin ceramic film electrolytes for high-voltage solid-state batteries.

25 ENERGY STORAGE↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Energy innovation in the US buildings sector: Setting the stage and mapping the future

Jared Langevin is a staff scientist at Lawrence Berkeley National Laboratory, where he leads modeling of US buildings sector innovation and its implications for energy demand, consumer costs, and the power grid. Eric Wilson is a senior research engineer in the Building Technologies and Sciences Center at the National Renewable Energy Laboratory (NREL). Much of his 15-year career at NREL has revolved around modeling and analysis of the US building stock. Jared and Eric co-led the development of a National Blueprint for buildings sector innovation while serving as advisors to the US Department of Energy’s Deputy Assistant Secretary for Buildings and Industry.

Langevin, Jared↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Navigating Common Electric Vehicle and Charging Infrastructure Concerns

Increasing knowledge about electric vehicles (EVs) can increase Tribal member comfort level with the technology, leading to increased EV adoption. This fact sheet lists common EV and charging infrastructure concerns and provides information to help address these hurdles during engagement with Tribal communities.

33 ADVANCED PROPULSION SYSTEMS↗

Development of electronically passivating surfaces to enhance battery performance

For many decades, lithium metal batteries (LMBs) have been studied for their high energy density, though they suffer from high reactivity, which safety concerns such as explosions and fires. These events can occur as a result of degradation due to redox reactions and lithium morphology that evolve during cycling. Mostly, the failure is caused by the electrolyte degradation leading to the creation of a solid electrolyte interphase (SEI), which tends to induce electron leakage, lithium dendrite growth, and capacity decay. SEI formation is practically inevitable. This work investigated the minimization of degradation events by modifying different battery configurations. Modifications were made by exchanging electrolytes, electrode surfaces, and even annexing innovative components. Our goal is to achieve a configuration where Li-ion transfer is facilitated, and electron transfer is limited which would enable a longer lithium metal battery life cycle. When performing these modifications and testing their electrochemical performance, a current reduction was observed when the electrodes were spontaneously coated with preformed SEI. Herein several classes of artificial SEI layers are explored for their ability to form passivating layers through use of a redox active molecule.

25 ENERGY STORAGE↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

Compressible battery foams to prevent cascading thermal runaway in Li-ion pouch batteries

Lithium-ion battery packs require thermal management to achieve optimum life and safety. This is becoming crucial for battery packs composed of high-energy-density cells. Pouch cells themselves achieve highest packaging efficiency but require additional structural support and thermal management when grouped into modules, especially under abusive conditions such as thermal runaway. Novel foam battery pads have demonstrated to cushion volume changes of pouch cells and are reengineered in this study to mitigate cell-to-cell thermal runaway propagation. The compressible pads are made of polyurethane foams incorporating flame-retardant additives or coatings, including intumescent and fire wall materials. Here their performances were evaluated by conducting nail penetration tests on modules composed of pouch cells at 100% state of charge (SOC), with the foams placed in between the cells. Experimental results show cascading thermal runaway was considerably delayed by polyurethane foams incorporating flame-retardant additives or coatings. Complete prevention of cascading failure was achieved with dense polyurethane foams with multilayered coatings of both fire wall and intumescent materials.

25 ENERGY STORAGE↗

Understanding the Nature of Capacity Decay and Interface Properties in Li//LiNi 0.5 Mn 1.5 O 4 Cells by Cycling Aging and Titration Techniques

The spinel structure LiNi 0.5 Mn 1.5 O 4 (LNMO) is a propitious cathode material for next-generation lithium-ion batteries for fast charge–discharge applications, but its capacity decay mechanism and rate-limiting process are not yet well understood. In this work, electrochemical impedance spectroscopy (EIS) with galvanostatic intermittent titration (GITT) and cycling aging techniques were employed to investigate the nature of capacity decay in disordered-phase LNMO. Different resistive components were separated after every 10 cycles. Cell overvoltages (ΔVs) due to ohmic conduction, charge transfer (CT), and concentration polarization (CP) were individually determined. Results revealed that the cell exhibited a higher ΔV at a higher discharged state. However, the ΔV value for CP was higher at a higher state of charge (SOC), and the overall LNMO/electrolyte interface played a major role in the rate-determining step. Battery life was estimated based on the results. Battery calendar life was found to be more vulnerable than cycle life. Furthermore, results also indicated that the working SOC range could be optimized based on the resistance analysis by avoiding those SOCs that have the most detrimental impact (e.g., heat generation and fire hazard).

25 ENERGY STORAGE↗

Design and experimental testing of a 150 kWh thermal battery using thermosiphons embedded in a concrete matrix for power plant flexible operation

One of the options for achieving the global temperature limitation of 1.5 °C target, for the mitigation of global warming, is based on the better penetration of renewables into the electrical grid. This has imposed a burden to fossil fuel fired power plants since they are required to operate away from their baseload mode to compensate for the inherent intermittence of the renewable power. Integrating energy storage with fossil plants is an option to achieve their needed flexibility. A cost competitive energy storage option for the solution is based on storing sensible heat in concrete. Here, this paper reports research results and development of a thermal battery cell (TBC) capable of operating at temperatures up to 425 °C. A novel concept consisting of a concrete matrix for sensible heat storage, engineered to provide enhanced thermal and mechanical properties, and twenty-two thermosiphon elements, engineered for dual action were designed and fabricated into a single thermal energy storage (TES) module. Research for the development of the components for the TBC was performed in the laboratory. Efficient heat transfer, to/from the storage media, was demonstrated under several charging and discharging conditions with a thermal storage capacity of 150 kWh th and a rapid discharge, making the TBC suitable for fast ramping when integrated with a fossil fuel fired power plant. Efficient radial heat transfer to the concrete was observed due to the well designed spacing and location of thermosiphons in the radial direction. A minimal temperature difference of 2 °C, between the thermosiphons bottom and top was obtained, demonstrating the isothermicity of those elements. An overall end-to-end TBC energy-to-energy round trip efficiency of 70% was achieved.

25 ENERGY STORAGE↗