Fundamental considerations of the crossed-beam correlation technique Final report
Crossed beam technique for remote sensing of thermodynamic properties and turbulence in flow fields
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Crossed beam technique for remote sensing of thermodynamic properties and turbulence in flow fields
The transformer ration of collinear beam-driven techniques can be significantly improved by shaping the current profile of the drive bunch. To date, several current shapes have been proposed to increase the transformer ratio and produce quasi-uniform energy loss within the drive bunch. Some of these tailoring techniques are possible as a results of recent beam-dynamics advances, e.g., transverse-to-longitudinal emittance exchanger. In ths paper, we propose an alternative class of longitudinal shapes that enable high transformer ratio and uniform energy loss across the drive bunch. We also suggest a simple method based on photocathode-laser shaping and passive shaping in wakefield structure to realize shape close to the theoretically optimized current profiles.
The Gaussian beam technique has become increasingly popular for wideband beam waveguide (BWG) design. However, it is observed that the Gaussian solution is less accurate for smaller mirrors (approximately less than 30 lambda in diameter). Therefore, a high-performance wideband BWG design cannot be achieved by using the Gaussian beam technique alone. This article demonstrates a new design approach by iterating Gaussian beam and BWG parameters simultaneously at various frequencies to obtain a wideband BWG. The result is further improved by comparing it with physical optics results and repeating the iteration.
Electron-beam generator produces high quality welds without vaporization by relying on the mobility and hydrodynamic properties of the material in its liquid phase. The power density of the beam is relative to the speed of the workpiece, producing an inclined weld-front.
To reduce the cross-talk between nanoscale devices, low-k materials such as methyl silsesquioxane (MSQ), which is damaged easily during plasma etching, are introduced as an intermetallic dielectric material in addition to the use of copper as the conducting material for the reduction of parasitic resistance and capacitance. In this study, beam techniques such as neutral/ion beams were used in the etching of MSQ and the effect of these beam techniques on the reduction of the degradation of the MSQ were investigated. When MSQ was etched using the same CF{sub 4} etch gas at the similar etch rate as that used for conventional MSQ etching using inductively coupled plasmas (ICPs), the neutral/ion beam etching showed lower F contents and lower penetration depth of F, indicating decreased degradation by fluorination of MSQ during etching using the beam techniques. Especially, the neutral beam etching technique showed the lowest F contamination and the lower penetration depth of F among the etch methods. When the dielectric constant was measured after the etching of the same depth, the MSQ etched with the neutral beam showed the lowest change of the dielectric constant, while that etched using the ICP showed the highest change of dielectric constant. The lower degradation, that is, the lower chemical modification of MSQ material with the beam technique is believed to be related to the decreased concentration of radical species in the processing chamber reacting with the MSQ surface, while the lowest degradation using the neutral beam is believed to be due to the lower reaction rate of the reactive neutral compared to reactive ions.
Three optical beam forming techniques are identified as applicable to large spaceborne phased array antennas. They are 1) the fiber replacement of conventional RF phased array distribution and control components, 2) spatial beam forming, and 3) optical beam splitting techniques. Two novel optical beam forming approaches, i.e., the spatial beam forming with a 'smart pixel' spatial light modulator (SLM) and the optical beam splitting approaches are conceived with integrated quasi-optical components. Also presented are the transmit and receive array architectures with the new SLM.
The achievable uncertainty in neutron lifetime measurements using the beam technique has been limited by the uncertainty in the determination of the neutron density in the decay volume. In the Sussex-ILL-NIST series of beam lifetime experiments, the density was determined with a neutron fluence mon itor that detected the charged particle products from neutron absorption in a thin layer of 6Li or lOB. In each of the experiments, the absolute detection efficiency of the neutron monitor was determined from the measured density of the neutron absorber, the thermal neutron cross section for the absorbing ma terial, and the solid angle of the charged particle detectors. The efficiency of the neutron monitor used in the most recent beam lifetime experiment has since been measured directly by operating it on a monochromatic neutron beam in which the total neutron rate is determined with a totally absorbing neutron detector. The absolute nature of this technique does not rely on any knowl edge of neutron absorption cross sections or a measurement of the density of the neutron absorbing deposit. This technique has been used to measure the neutron monitor efficiency to 0.06% uncertainty. VVe show that a new monitor and absolute neutron detector employing the same technique would be capable of achieving determining neutron fluence to an uncertainty of 0.01%.
Various design techniques used for beam waveguide (BWG) feed systems are characterized. These include the use of gaussian beam, geometrical optics, and physical optics systems. Also introduced is a new technique based upon a conjugate phase matching focal plane technique. Advantages, disadvantages, and range of applicability of each technique is given, In addition, comparisons of computed and measured results from each type of design are presented.
Laser beam technique to initiate single bubble around thermocouple, and bubble growth rate and sphericity using high speed photography
Techniques for combining initially separate single mode and multimode optical beams into a single "Dual Mode" fiber optic have been developed. Bi-directional propagation of two beams that are differentiated only by their mode profiles (i.e., wavefront conditions) is provided. The beams can be different wavelengths and or contain different modulation information but still share a common aperture. This method allows the use of conventional micro optics and hybrid photonic packaging techniques to produce small rugged packages suitable for use in industrial or military environments.
Purpose: To propose and validate a craniospinal irradiation approach using a proton pencil beam scanning technique that overcomes the complexity of the planning associated with feathering match lines. Methods and Materials: Ten craniospinal irradiation patients had treatment planned with gradient dose optimization using the proton pencil beam scanning technique. The robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in the longitudinal direction and was compared with the original nonshifted plan with metrics of conformity number, homogeneity index, and maximal cord doses. An anthropomorphic phantom study using film measurements was carried out on a plan with 5-cm junction length. To mimic setup errors in the phantom study, fields were recalculated with isocenter shifts of 1, 3, 5, and 10 mm longitudinally, and compared with the original plans and measurements. Results: Uniform dose coverage to the entire target volumes was achieved using the gradient optimization approach with averaged junction lengths of 6.7 ± 0.5 cm. The average conformity number and homogeneity index equaled 0.78 ± 0.03 and 1.09 ± 0.01, respectively. Setup errors of 3 mm per field (6 mm in worst-case scenario) caused on average 4.6% lower conformity number 2.5% higher homogeneity index and maximal cord dose of 4216.1 ± 98.2 cGy. When the junction length was 5 cm or longer, setup errors of 6 mm resulted in up to 12% dosimetric deviation. Consistent results were reached between film measurements and planned dose profiles in the junction area. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the proton craniospinal irradiation treatment with matched proton pencil beam scanning fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust to longitudinal setup errors compared to conventional feathering methods.
Electron beam gun technique for aluminizing large collimating mirror
Multi-electrode technique named as wire beam electrode (WBE) was used to study pitting corrosion of rebar under concrete cover. When WBE embedded mortar sample was immersed in NaCl solution, uneven distributions of galvanic current and open circuit potential (OCP) on the WBE were observed due to the initiation of pitting corrosion. The following oxygen depletion in mortar facilitated the negative shift of the OCP and the smoothing of the current and potential distributions. Wetting–drying cycle experiments showed that corrosion products instead of oxygen in wet mortar specimen sustained the propagation of pitting corrosion due to Fe (III) taking part in cathodic depolarization during oxygen-deficient wet period, which was confirmed by micro-Raman spectroscopy. In addition, new pitting corrosion occurred mainly near the corrosion products, leading to preferentially horizontal propagation of rust layer on the WBE. A localized corrosion factor was further presented to quantify the localised corrosion based on galvanic current maps.
Techniques for defining a finite element model (FEM) for analysis of nonlinear vibrations in beam structures subjected to harmonic excitation are presented. The resulting model covers longitudinal deformation and inertial effects. The nonlinear oscillations of a beam element under forced excitation are modeled by a harmonic force matrix based on first order approximations of the Jacobian elliptic forcing function. Harmonic force and nonlinear stiffness matrices are derived and the nonlinear forced responses of beams are calculated under various boundary conditions. The results of FEM computations for simply-supported and clamped beams show that midplane stretching caused by large deflections increases the nonlinearity. Axially-restrained beams experience only hardening nonlinearity, while axially-free beams have reduced nonlinearity in deformation and inertia and an increase in linearity due to large deflection.
Explore the source record for details and available documents.
The development of the X-ray divergent-beam (Kossel) technique over the last 50 years is traced. The fundamentals of this technique and ways to implement it experimentally are considered, and its potential for studying the real structure of crystals is analyzed in detail.
IrSi(3)/p-Si Schottky diodes have been fabricated by a molecular beam epitaxy technique at 630 C. Good surface morphology was observed for IrSi(3) layers grown at temperatures below 680 C, and an increasing tendency to form islands is observed in samples grown at higher temperatures. Good diode current-voltage characteristics were observed and Schottky barrier heights of 0.14-0.18 eV were determined by activation energy analysis and spectral response measurement.
A portable dual-laser-beam interferometer that nonintrusively measures skin friction by monitoring the thickness change of an oil film subject to shear stress is described. The method is an advance over past versions in that the troublesome and error-introducing need to measure the distance to the oil leading edge and the starting time for the oil flow has been eliminated. The validity of the method was verified by measuring oil viscosity in the laboratory, and then using those results to measure skin friction beneath the turbulent boundary layer in a low speed wind tunnel. The dual-laser-beam skin friction measurements are compared with Preston tube measurements, with mean velocity profile data in a "law-of-the-well" coordinate system, and with computations based on turbulent boundary-layer theory. Excellent agreement is found in all cases. (This validation and the aforementioned improvements appear to make the present form of the instrument usable to measure skin friction reliably and nonintrusively in a wide range of flow situations in which previous methods are not practical.)