SEARCH · Search NASA
Results for “biomechanics”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Two surveys of the needs of engineering schools in the field of biomechanical and human factors engineering education
Surveys of engineering school needs in field of biomechanical and human factors engineering education
Ergonomic Models of Anthropometry, Human Biomechanics and Operator-Equipment Interfaces
The Committee on Human Factors was established in October 1980 by the Commission on Behavioral and Social Sciences and Education of the National Research Council. The committee is sponsored by the Office of Naval Research, the Air Force Office of Scientific Research, the Army Research Institute for the Behavioral and Social Sciences, the National Aeronautics and Space Administration, and the National Science Foundation. The workshop discussed the following: anthropometric models; biomechanical models; human-machine interface models; and research recommendations. A 17-page bibliography is included.
Muscular activity and its relationship to biomechanics and human performance
The purpose of this manuscript is to address the issue of muscular activity, human motion, fitness, and exercise. Human activity is reviewed from the historical perspective as well as from the basics of muscular contraction, nervous system controls, mechanics, and biomechanical considerations. In addition, attention has been given to some of the principles involved in developing muscular adaptations through strength development. Brief descriptions and findings from a few studies are included. These experiments were conducted in order to investigate muscular adaptation to various exercise regimens. Different theories of strength development were studied and correlated to daily human movements. All measurement tools used represent state of the art exercise equipment and movement analysis. The information presented here is only a small attempt to understand the effects of exercise and conditioning on Earth with the objective of leading to greater knowledge concerning human responses during spaceflight. What makes life from nonliving objects is movement which is generated and controlled by biochemical substances. In mammals. the controlled activators are skeletal muscles and this muscular action is an integral process composed of mechanical, chemical, and neurological processes resulting in voluntary and involuntary motions. The scope of this discussion is limited to voluntary motion.
Biomechanical Analysis of T2 Exercise
Crewmembers regularly perform treadmill exercise on the ISS. With the implementation of T2 on ISS, there is now the capacity to obtain ground reaction force (GRF) data GRF data combined with video motion data allows biomechanical analyses to occur that generate joint torque estimates from exercise conditions. Knowledge of how speed and load influence joint torque will provide quantitative information on which exercise prescriptions can be based. The objective is to determine the joint kinematics, ground reaction forces, and joint kinetics associated with treadmill exercise on the ISS. This study will: 1) Determine if specific exercise speed and harness load combinations are superior to others in exercise benefit; and 2) Aid in the design of exercise prescriptions that will be most beneficial in maintaining crewmember health.
Metabolic Costs and Biomechanics of Inclined Ambulation and Exploration Tasks in a Planetary Suit
Observations from Apollo lunar surface extravehicular activities (EVAs) and a few studies conducted in partial-gravity simulation environments have helped us understand suited human performance in reduced-gravity environments. The Constellation Program EVA Systems Project Office initiated a series of tests aimed at increasing our understanding of human performance and suit kinematics under various simulated lunar EVA conditions, including matched unsuited controls, to identify the specific metabolic costs and biomechanics of the prototype Mark III Advanced Spacesuit Technology Demonstrator. A primary goal of the series is to provide evidence-based recommendations for suit mass, center of gravity, pressure, and suit kinematic constraints that optimize human performance in partial-gravity environments. Results will be combined with studies in other lunar analogs to evaluate the effectiveness and limitations of these environments. As our understanding of suited human performance matures, different combinations of variables can be evaluated to determine whether significant interactions exist between parameters. This report provides an overview of key findings of Integrated Suit Test (IST)-2. As future tests are completed, focusing on other suit factors, analog environments, or different suits, study results will be combined and reevaluated. The series of tests comprising IST-2 was conducted from June 13, 2007 through October 24, 2007.
Biomechanical Modeling of the Deadlift Exercise on the HULK Device to Improve the Efficacy of Resistive Exercise Microgravity Countermeasures
Extended spaceflight typically results in the loss of muscular strength and bone density due to exposure to microgravity. Resistive exercise countermeasures have been developed to maintain musculoskeletal health during spaceflight. The Advanced Resistive Exercise Device (ARED) is the "gold standard" of available devices; however, its footprint and volume are too large for use in space capsules employed in exploration missions. The Hybrid Ultimate Lifting Kit (HULK) device, with its smaller footprint, is a prototype exercise device for exploration missions. This work models the deadlift exercise being performed on the HULK device using biomechanical simulation, with the long-term goal to improve and optimize astronauts' exercise prescriptions, to maximize the benefit of exercise while minimizing time and effort invested.
Earth-Based Analogs & Modeling for Exercise Biomechanics in Space
The biomechanics of exercise in space is difficult to study and there are unknowns surrounding exercise performance on future space exploration countermeasures systems. These issues are beginning to be addressed through enhanced modeling techniques fueled initially by human-in-the-loop data collections in ground-based environments. The presentation will focus on an effort completed at the University of South Florida to apply the Computer Assisted Rehabilitation Environment (CAREN) system to address a human spaceflight need. The research explored the interaction between a human and a moving platform while exercise was completed.
Human Factors Applications of Biomechanical Modeling
Biomechanical data collection and modeling has applications to the field of human factors. Specifically, motion data can be used to determine the operational volume necessary for performing a task. The operational volume assessment can be performed in order to determine how much volume is needed to perform the task or if task performance can be contained and adequately performed within an allocated volume. Motion and external force data, along with computational modeling techniques, can be used to estimate the internal loading produced during performance of a task. Internal loading estimates can be used to determine if an adequate stimulus is generated for maintenance of musculoskeletal health and also for comparison to injury thresholds to determine injury risk during task performance.
Anthropometric Measurement Procedures at the Anthropometry and Biomechanics Facility
The Anthropometry and Biomechanics Facility (ABF) at NASA Johnson Space Center (JSC) is the centralized source of anthropometry data at NASA for use in requirement development, engineering design, and verification of human-system integrations such as spacesuits and vehicles. To ensure the collection of consistent, accurate, and valid anthropometry data, ABF has defined anthropometric measurements and anatomical landmarks which are generally based on the Anthropometric Survey for US Army Personnel (ANSUR), but with additional measurements which have been uniquely designed for spacesuit and hardware accommodation purposes. Unlike ANSUR, NASA anthropometry measurements primarily rely on 3D body scanning, a method which allows for explicitly defining the process of collecting measurements and the quality control methods used to ensure measurement reliability. In addition to ABF’s anthropometry measurement definitions and procedures, this presentation will also compare specifics of different measurement techniques ABF uses, for example, laser scanning versus manual measurement methods (e.g., tape measure or anthropometer-based), and the benefits and considerations of each method. The evolution of ABF’s measurement process will also be addressed, as new spaceflight programs have been introduced which have required unique measurements and the need to capture body shape changes over time was identified to be critical for spacesuit fit in some instances.
Anthropometric Measurement Procedures at the Anthropometry and Biomechanics Facility
The Anthropometry and Biomechanics Facility (ABF) at NASA Johnson Space Center (JSC) is the centralized source of anthropometry data at NASA for use in requirement development, engineering design, and verification of human-system integrations such as spacesuits and vehicles. To ensure the collection of consistent, accurate, and valid anthropometry data, ABF has defined anthropometric measurements and anatomical landmarks which are generally based on the Anthropometric Survey for US Army Personnel (ANSUR), but with additional measurements which have been uniquely designed for spacesuit and hardware accommodation purposes. Unlike ANSUR, NASA anthropometry measurements primarily rely on 3D body scanning, a method which allows for explicitly defining the process of collecting measurements and the quality control methods used to ensure measurement reliability. In addition to ABF’s anthropometry measurement definitions and procedures, this presentation will also compare specifics of different measurement techniques ABF uses, for example, laser scanning versus manual measurement methods (e.g., tape measure or anthropometer-based), and the benefits and considerations of each method. The evolution of ABF’s measurement process will also be addressed, as new spaceflight programs have been introduced which have required unique measurements and the need to capture body shape changes over time was identified to be critical for spacesuit fit in some instances.
Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling
Background: As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab at NASA Johnson Space Center (JSC), aims to address this challenge through innovative approaches. Objective: Development and evaluation of a NGED system, focusing on its adaptability to various Moon to Mars mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). To help inform vehicle and system requirements, an exercise volumetric assessment was performed via data collection and biomechanical modeling.
The Biomechanics of Indirect Traumatic Optic Neuropathy Using a Computational Head Model With a Biofidelic Orbit
Indirect traumatic optic neuropathy (ITON) is an injury to the optic nerve due to head trauma and usually results in partial or complete loss of vision. In order to advance a mechanistic understanding of the injury to the optic nerve, we developed a head model with a biofidelic orbit. Head impacts were simulated under controlled conditions of impactor velocity. The locations of impact were varied to include frontal, lateral, and posterior parts of the head. Impact studies were conducted using two types of impactors that differed in their rigidity relative to the skull. The simulated results from both the impactors suggest that forehead impacts are those to which the optic nerve is most vulnerable. The mode and location of optic nerve injury is significantly different between the impacting conditions. Simulated results using a relatively rigid impactor (metal cylinder) suggest optic nerve injury initiates at the location of the intracranial end of the optic canal and spreads to the regions of the optic nerve in the vicinity of the optic canal. In this case, the deformation of the skull at the optic canal, resulting in deformation of the optic nerve, was the primary mode of injury. On the other hand, simulated results using a relatively compliant impactor (soccer ball) suggest that primary mode of injury comes from the brain tugging upon the optic nerve (from where it is affixed to the intracranial end of the optic canal) during coup countercoup motion of the brain. This study represents the first published effort to employ a biofidelic simulation of the full length of the optic nerve in which the orbit is integrated within the whole head.
Biomechanics of walking and running: center of mass movements to muscle action
No abstract available
Pyridoxine deficiency affects biomechanical properties of chick tibial bone
The mechanical integrity of bone is dependent on the bone matrix, which is believed to account for the plastic deformation of the tissue, and the mineral, which is believed to account for the elastic deformation. The validity of this model is shown in this study based on analysis of the bones of vitamin B6-deficient and vitamin B6-replete chick bones. In this model, when B6-deficient and control animals are compared, vitamin B6 deficiency has no effect on the mineral content or composition of cortical bone as measured by ash weight (63 +/- 6 vs. 58 +/- 3); mineral to matrix ratio of the FTIR spectra (4.2 +/- 0.6 vs. 4.5 +/- 0.2), line-broadening analyses of the X-ray diffraction 002 peak (beta 002 = 0.50 +/- 0.1 vs. 0.49 +/- 0.01), or other features of the infrared spectra. In contrast, collagen was significantly more extractable from vitamin B6-deficient chick bones (20 +/- 2% of total hydroxyproline extracted vs. 10 +/- 3% p < or = 0.001). The B6-deficient bones also contained an increased amount of the reducible cross-links DHLNL, dehydro-dihydroxylysinonorleucine, (1.03 +/- 0.07 vs. 0.84 +/- 0.13 p < or = 0.001); and a nonsignificant increase in HLNL, dehydro-hydroxylysinonorleucine, (0.51 +/- 0.03 vs. 0.43 +/- 0.03, p < or = 0.10). There were no significant changes in bone length, bone diameter, or area moment of inertia. In four-point bending, no significant changes in elastic modulus, stiffness, offset yield deflection, or fracture deflection were detected. However, fracture load in the B6-deficient animals was decreased from 203 +/- 35 MPa to 151 +/- 23 MPa, p < or = 0.01, and offset yield load was decreased from 165 +/- 9 MPa to 125 +/- 14 MPa, p < or = 0.05. Since earlier histomorphometric studies had demonstrated that the B6-deficient bones were osteopenic, these data suggest that although proper cortical bone mineralization occurred, the alterations of the collagen resulted in changes to bone mechanical performance.
The effect of in situ freezing on rabbit patellar tendon. A histologic, biochemical, and biomechanical analysis
Cell necrosis has been well documented as one of the many changes that occur in autogenous tendon when it is used to reconstruct the anterior cruciate ligament. The purpose of this experiment was to isolate cell necrosis as a variable and study its effect on the patellar tendon. To accomplish this, both knees of 25 New Zealand White rabbits were operated on. In one knee, a 5-mm wide band of patellar tendon was subjected to two rapid freeze-thaw cycles, while the other knee underwent sham surgery. Histologic evaluation showed a zone of necrosis at 2 and 4 weeks with cellular repopulation complete at 8 weeks. patellar tendon cross-sectional area was 0.118 cm2 at 8 weeks for the frozen specimens compared to 0.102 cm2 for the sham-operated controls. This difference was significant at the P = 0.025 level. Mechanical testing at 4 and 8 weeks revealed no significant changes in tendon length, maximum load, or stiffness. The collagen content was also unchanged at both 4 and 8 weeks.