Search NASA⌕ Search

SEARCH · Search NASA

Results for “blind system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Regional quantitative play fairway analysis: methodology global examples and application for the East African Rift system

Most volcanic arcs and active rifts around the world host producing geothermal systems. Many undiscovered and/or undeveloped systems remain in each of these areas, including magmatic-heated systems, amagmatic extension-related systems, and blind resources lacking active surface manifestations in both types of settings. However, not all volcanic centers or extensional terranes have the same geothermal potential. For example, even when high heat flow is present, permeability is commonly a limiting factor to resource development. A tool recently adapted for the geothermal industry is play fairway analysis, which calculates the regional probability of power-capable resources based on the spatial coincidence of key geologic conditions. In a geothermal setting, these key geologic conditions are heat, permeability, and fluids. Higher enthalpy systems also benefit from suitable cap rock. These parameters can be assessed through multiple geologic, geochemical, and geophysical data sets and integrated quantitatively to produce a single geothermal play fairway map. Potential input data sets include but are not limited to: 1) tectonic setting; 2) structural setting; 3) faults attributed by recency of rupture and slip rate; 3) geodetic crustal stain models; 5) gravity; 6) earthquake distribution; 7) thermal models; 8) geochemistry from springs, wells, and fumaroles; 9) temperature from springs, wells, and fumaroles; 10) fumarole size and type; and 11) age of volcanism. Recent play fairway studies have been completed for volcanic arcs and the dominantly amagmatic, extensional Great Basin region, USA, but have yet to be applied to the East African Rift System (EARS). Previous estimates of total geothermal resource capacity in the EARS is ~20 GWe, but only three areas are currently in production as of 2015: Olkaria and Eburru in Kenya, and Aluto-Langano in Ethiopia for a total installed capacity of <0.7 GWe. Many more volcanic centers host potential resources. In addition, amagmatic and/or blind systems also have potential in the EARS. Play fairway analysis can highlight regions most prospective for geothermal resource development, help identify locations prospective for undiscovered resources, prioritize overall exploration and development efforts, and refine estimates for total undeveloped resource potential.

15 GEOTHERMAL ENERGY↗

Blindness in designing intelligent systems

New investigations of the foundations of artificial intelligence are challenging the hypothesis that problem solving is the cornerstone of intelligence. New distinctions among three domains of concern for humans--description, action, and commitment--have revealed that the design process for programmable machines, such as expert systems, is based on descriptions of actions and induces blindness to nonanalytic action and commitment. Design processes focusing in the domain of description are likely to yield programs like burearcracies: rigid, obtuse, impersonal, and unable to adapt to changing circumstances. Systems that learn from their past actions, and systems that organize information for interpretation by human experts, are more likely to be successful in areas where expert systems have failed.

Denning, Peter J.↗

Gravity Survey of the Carson Sink - Data and Maps

A detailed gravity survey was carried out for the entire Carson Sink in western Nevada (Figure 1) through a subcontract to Zonge Engineering, Inc. The Carson Sink is a large composite basin containing three known, blind high-temperature geothermal systems (Fallon Airbase, Stillwater, and Soda Lake). This area was chosen for a detailed gravity survey in order to characterize the gravity signature of the known geothermal systems and to identify other potential blind systems based on the structural setting indicated by the gravity data. Data were acquired at approximately 400, 800, and 1600 meter intervals for a total of 1,243 stations. The project location and station location points are presented in Figure 14. The station distribution for this survey was designed to complete regional gravity coverage in the Carson Sink area without duplication of available public and private gravity coverage. Gravity data were acquired using a Scintrex CG-5 gravimeter and a LaCoste and Romberg (L&R) Model-G gravimeter. The CG-5 gravity meter has a reading resolution of 0.001 milligals and a typical repeatability of less than 0.005 milligals. The L&R gravity meter has a reading resolution of 0.01 milligals and a typical repeatability of 0.02 milligals. The basic processing of gravimeter readings to calculate through to the Complete Bouguer Anomaly was made using the Gravity and Terrain Correction software version 7.1 for Oasis Montaj by Geosoft LTD. The gravity survey of the Carson Sink yielded a project location and station location map, a Complete Bouguer Anomaly @ 2.67 gm/cc reduction density, a Gravity Complete Bouguer Anomaly at 2.50 g/cc Contour Map, a Gravity Horizontal Gradient Magnitude Shaded Color Contour Map, a Gravity 1st Vertical Derivative Color Contour Map, and an Interpreted Depth to Mesozoic Basement incorporating drill-hole intercept values. A preliminary interpretation of these results suggests that the Carson Sink is a complex composite basin with several major depocenters. Major depocenters are present in the south-central, east-central, and northeastern parts of the basin. The distribution of gravity anomalies suggests a complex pattern of faulting in the subsurface of the basin, with many fault terminations, step-overs, and accommodation zones. The pattern of faulting implies that other, previously undiscovered blind geothermal systems are likely in the Carson Sink. The gravity survey was completed near the end of this project. Thus, more thorough analysis of the data and potential locations of blind geothermal systems is planned for future work.

15 GEOTHERMAL ENERGY↗

A play fairway approach to geothermal exploration in Crescent Valley, Nevada

Crescent Valley received one of the highest favorability scores in phase I of the DOE-sponsored Nevada play fairway analysis project and was therefore selected for detailed study in phase II. As part of the detailed study, geological, geochemical, and geophysical data were collected, synthesized, and analyzed to identify favorable structural settings for geothermal fluids in the basin. A total of eight favorable structural settings were identified. Two host known geothermal systems, and six could potentially host blind geothermal systems. In phase II a predictive geothermal potential model was conducted for each favorable structural setting. The highest-ranking areas in Crescent Valley are in the Dann Hot Springs step-over (relay ramp), followed by the two northern step-overs along the Cortez Mountains front, as well as a fault intersection at Hot Springs Point.

15 GEOTHERMAL ENERGY↗

THE ALFALFA H I ABSORPTION PILOT SURVEY: A WIDE-AREA BLIND DAMPED Ly{alpha} SYSTEM SURVEY OF THE LOCAL UNIVERSE

We present the results of a pilot survey for neutral hydrogen (H I) 21 cm absorption in the Arecibo Legacy Fast Arecibo L-Band Feed Array (ALFALFA) Survey. This project is a wide-area 'blind' search for H I absorption in the local universe, spanning -650 km s{sup -1} < cz < 17, 500 km s{sup -1} and covering 517.0 deg{sup 2} (7% of the full ALFALFA survey). The survey is sensitive to H I absorption lines stronger than 7.7 mJy (8983 radio sources) and is 90% complete for lines stronger than 11.0 mJy (7296 sources). The total redshift interval sensitive to all damped Ly{alpha} (DLA) systems (N{sub H{sub i}}{>=}2 Multiplication-Sign 10{sup 20} cm{sup -2}) is {Delta}z = 7.0 (129 objects, assuming T{sub s} = 100 K and covering fraction unity); for super-DLAs (N{sub H{sub i}}{>=}2 Multiplication-Sign 10{sup 21} cm{sup -2}) it is {Delta}z = 128.2 (2353 objects). We re-detect the intrinsic H I absorption line in UGC 6081 but detect no intervening absorption line systems. We compute a 95% confidence upper limit on the column density frequency distribution function f(N{sub H{sub i}},X) spanning four orders of magnitude in column density, 10{sup 19} (T{sub s} /100 K) (1/f) cm{sup -2}<N{sub H{sub I}}<10{sup 23}(Ts/100 K)(1/f) cm{sup -2}, that is consistent with previous redshifted optical DLA surveys and the aggregate H I 21 cm emission in the local universe. The detection rate is in agreement with extant observations. This pilot survey suggests that an absorption line search of the complete ALFALFA survey-or any higher redshift, larger bandwidth, or more sensitive survey, such as those planned for Square Kilometer Array pathfinders or a low-frequency lunar array-will either make numerous detections or will set a strong statistical lower limit on the typical spin temperature of neutral hydrogen gas.

79 ASTRONOMY AND ASTROPHYSICS↗

A tactile paging system for deaf-blind people, phase 2

Control logic and the on-body radio transmitter is investigated. The control logic capability and studied methods for implementing the on-body portion of the logic in a small package are improved. A small low power, on-body transmitter was designed, developed, and tested with a wrist-strap antenna to extend the one-way communication system developed during Phase 1 to a two-way communication system.

Baer, J. A.↗

Desert Peak Geodatabase for Geothermal Exploration Artificial Intelligence

These files contain the geodatabases related to the Desert Peak Geothermal Field. It includes all input and output files used in the project. The files include data categories of raw data, pre-processed data, and analysis (post-processed data). In each of these categories there are six additional types of raster catalogs including Radar, SWIR, Thermal, Geophysics, Geology, and Wells. The files for the Desert Peak Geothermal Site are used with the Geothermal Exploration Artificial Intelligence to identify indicators of blind geothermal systems. The included zip file is a geodatabase to be used with ArcGIS and the tar file is an inclusive database that encompasses the inputs and outputs for the Desert Peak Geothermal Field.

15 GEOTHERMAL ENERGY↗

Salton Sea Geodatabase for Geothermal Exploration Artificial Intelligence

These files contain the geodatabases related to Salton Sea Geothermal Field. It includes all input and output files used with the Geothermal Exploration Artificial Intelligence. Input and output files are sorted into three categories: raw data, pre-processed data, and analysis (post-processed data). In each of these categories there are six additional types of raster catalogs which are titled Radar, SWIR, Thermal, Geophysics, Geology, and Wells. The files are used with the Geothermal Exploration Artificial Intelligence for the Salton Sea Geothermal Site to identify indicators of blind geothermal systems. The included zip file is a geodatabase to be used with ArcGIS and the tar file is an inclusive database that encompasses the inputs and outputs for the Salton Sea Geothermal Site.

15 GEOTHERMAL ENERGY↗

Brady Geodatabase for Geothermal Exploration Artificial Intelligence

These files contain the geodatabases related to Brady's Geothermal Field. It includes all input and output files for the Geothermal Exploration Artificial Intelligence. Input and output files are sorted into three categories: raw data, pre-processed data, and analysis (post-processed data). In each of these categories there are six additional types of raster catalogs which are titled Radar, SWIR, Thermal, Geophysics, Geology, and Wells. These inputs and outputs were used with the Geothermal Exploration Artificial Intelligence to identify indicators of blind geothermal systems at the Brady Hot Springs Geothermal Site. The included zip file is a geodatabase to be used with ArcGIS and the tar file is an inclusive database that encompasses the inputs and outputs for the Brady Hot Springs Geothermal Site.

15 GEOTHERMAL ENERGY↗

Characterizing Signatures of Geothermal Exploration Data with Machine Learning Techniques: An Application to the Nevada Play Fairway Analysis

We are introducing machine learning methods to the play fairway analysis to generate geothermal potential maps to support the evaluation of geothermal resource potential and the exploration for undiscovered blind geothermal systems in the Nevada Great Basin region. Our project aims to identify new ways to combine the play fairway data and empirically organize relationships between feature weights and labels in an improved workflow. As a means of doing this, we introduce machine learning methods to evaluate the influence of certain geological and geophysical features/feature sets in predicting geothermal favorability. This report highlights promising approaches based on supervised and unsupervised learning methods. First, we demonstrate a filter method applied to supervised classification modeling. The supervised filter method is based on permutation analysis to evaluate every possible feature combination/drop out scenario and rank feature influence based on the performance variance of supervised classification models. Additionally, we present an unsupervised factor analysis based on principal component analysis coupled with a semi-supervised kmeans clustering algorithm. This analysis allows us to identify the optimal number of groups/clusters for training sites and structural settings to identify feature patterns including correlation, variance, and latent and dominant feature relationships. The results from these methods offer a promising avenue for identifying favorable sources of predictive information to identify the locations of blind geothermal systems and furthering our understanding of complex geothermal feature and label relationships in the Great Basin region and beyond.

15 GEOTHERMAL ENERGY↗

Exploratory analysis of machine learning techniques in the Nevada geothermal play fairway analysis

Play fairway analysis (PFA) is commonly used to generate geothermal potential maps and guide exploration studies, with a particular focus on locating and characterizing blind geothermal systems. This study evaluates the application of machine learning techniques to PFA in the Great Basin region of Nevada. Following the evaluation of various techniques, we identified two approaches to PFA that produced promising results, 1) supervised Bayesian probabilistic neural networks to generate geothermal potential maps with confidence intervals, and 2) unsupervised principal component analysis paired with k-means clustering to generate both cluster maps to help identify spatial patterns, as well as new combined feature inputs. We applied these techniques to perform a comparative analysis between two principal sets of geological and geophysical features related to permeability and heat and a set of positive (known geothermal resources) and negative training sites (known drill sites with unsuitable geothermal conditions). We found that these methods constrain previously unrecognized feature controls on geothermal favorability, many of which are spatially organized within the extent of cluster groups and the major structural-hydrologic domains of the study area. Furthermore, we utilized exploratory unsupervised modeling to highlight spatial relationships between input data and predictive output results of our supervised modeling. As a result, we demonstrate how our models compare to the previous Nevada PFA and how the rapid insights these machine learning techniques offer may support future assessments of both known and undiscovered blind geothermal systems in the Great Basin region of Nevada and beyond.

15 GEOTHERMAL ENERGY↗

Structural Controls of the Emerson Pass Geothermal System, Washoe County, Nevada

We have conducted a detailed geologic study to better characterize a blind geothermal system in Emerson Pass on the Pyramid Lake Paiute Tribe Reservation, western Nevada. A thermal anomaly was discovered in Emerson Pass by use of 2 m temperature surveys deployed within a structurally favorable setting and proximal to surface features indicative of geothermal activity. The anomaly lies at the western edge of a broad left step at the northeast end of Pyramid Lake between the north- to north-northeast-striking, west-dipping, Fox and Lake Range normal faults. The 2-m temperature surveys have defined a N-S elongate thermal anomaly that has a maximum recorded temperature of ~60°C and resides on a north- to north-northeaststriking fault. Travertine mounds, chalcedonic silica veins, and silica cemented Pleistocene lacustrine gravels in Emerson Pass indicate a robust geothermal system active at the surface in the recent past. Structural complexity and spatial heterogeneities of the strain and stress field have developed in the step-over region, but kinematic data suggest a WNW-trending (~280° azimuth) extension direction. The geothermal system is likely hosted in Emerson Pass as a result of enhanced permeability generated by the intersection of two oppositely dipping, southward terminating north- to north-northwest-striking (Fox Range fault) and northnortheast- striking faults.

15 GEOTHERMAL ENERGY↗

"Speaking" Microcomputer

Microcomputer system allows blind person to use portable computer and communicate with remote mainframe computer. System prepares data for transmission to mainframe, translates data transmitted from mainframe for its own use, and converts data ordinarily displayed on its video screen into synthesized speech.

Mandy, C.↗

Three-Dimensional Geologic Characterization of a Great Basin Geothermal System: Astor Pass, Nevada

The Great Basin, western USA, exhibits anomalously high heat flow (~75±5 mWm-2) and active faulting and extension, resulting in ~430 known geothermal systems. Recent studies have shown that steeply dipping normal faults in transtensional pull-aparts are a common structural control of these Great Basin geothermal systems. The Astor Pass blind (no surface expression) geothermal system, Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Across this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range, resulting in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and northerly striking normal faults. Previous studies indicate that Astor Pass was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal-dextral fault bounding the western side of the Terraced Hills. Drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming a blind geothermal system. Expanding upon previous work and employing interpretation of 2D seismic reflection data, additional detailed geologic mapping, and well cuttings analysis, a 3-dimensional geologic model of the Astor Pass geothermal system was constructed. The 3D model indicates a complex interaction/intersection area of three discrete fault zones: a northwest-striking dextral-normal fault, a north-northwest-striking normal-dextral fault, and a north-striking west-dipping normal fault. These two discrete, critically-stressed intersection areas plunge moderately to steeply to the NW-NNW and probably act as conduits for upwelling geothermal fluids.

15 GEOTHERMAL ENERGY↗

The Steady State Challenge for Soft X-Ray Diagnostics on Wendelstein 7-X Stellarator

The steady state operation of Wendelstein 7-X stellarator presently under construction in Greifswald poses special challenges to the diagnostics development [1, 2]. A critical issue is the heat load on plasma facing components ({approx}500 kW/m{sup 2}) over a long discharge time (up to 30 min), which leads to the necessity of active cooling. As result, the design of the 400 channel soft X-Ray Multi Camera Tomography System (XMCTS) [2, 3] has to cope with dark currents and amplifier drifts due to the heating of active components like photo diodes and in-vessel preamplifiers. In order to allow for a quantitative measurement of dynamic drifts and offsets, a shutter system and blind diodes are considered to compensate these effects. Another important issue is the large amount of data gathered by the XMCT system during long pulse discharges. A fast but less precise online reconstruction is planned, which will give information on the plasma shape and position on a human time scale. The two options under investigation are a Cormack-Inversion method and an approach based on neural networks [4]. Dependent on the available hardware, as much information as possible should be stored for more accurate offline-analysis. An intelligent way of marking interesting data is required. In case that the steady-state storage of all measured data is not feasible, at least this marked data will be stored in high time resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary report on applications of machine learning techniques to the Nevada play fairway analysis

We are applying machine learning (ML) techniques, including training set augmentation and artificial neural networks, to mitigate key challenges in the Nevada play fairway project. The study area includes ~85 active geothermal systems as potential training sites and >12 geologic, geophysical, and geochemical features. The main goal is to develop an algorithmic approach to identify new geothermal systems in the Great Basin region. Major objectives include: 1) integrate ML techniques into the geothermal community; 2) develop open community datasets, whereby all play fairway and ML datasets and algorithms are publicly released and available for modification by various user groups; 3) identify data acquisition targets with high value for future work; 4) identify new signatures to detect blind geothermal systems; and 5) foster new capabilities for characterizing subsurface temperature and permeability. Initially, ML techniques are being applied to the same play fairway datasets and workflow. ML will then be applied to both enhanced and additional datasets, with modification of the PFA workflow to incorporate the new datasets. Finally, ML will be applied to define new workflows using the enhanced and additional datasets. An algorithmic approach that empirically learns to estimate weights of influence for diverse parameters can potentially scale and perform better than the play fairway analysis. Initial work on this project has involved 1) evaluating potential positive and negative training sites, 2) transformation of datasets into formats suitable for ML, and 3) initial development and testing of ML techniques.

58 GEOSCIENCES↗

Building the Next Generation of Regional Geothermal Potential Maps: Examples from the Great Basin Region, Western USA

Over the past decade research has greatly advanced our understanding of structurally controlled geothermal systems and the potential for “deep stratigraphic reservoirs” in the Great Basin region, western USA. For example, studies have shown that structurally controlled geothermal systems are associated with specific structural settings, such as terminations of major normal faults, accommodation zones, pull-aparts in strike-slip faults, displacement transfer zones, or step-overs in range-front faults. However, we know that not every structure (e.g., termination of a major normal fault or step-over in a range-front fault) hosts an active geothermal system. Recent research has also shown that regional strain rate model as determined from GPS geodesy, the composition of that strain (extensional versus shear or compressive strain), recency of Quaternary faulting, and slip and dilation tendency of faults correlate positively with the distribution of both high and low-temperature, structurally controlled geothermal systems within the Great Basin. Combining these strain data and fault slip history data sets with existing temperature gradient data, heat flow data, spring temperatures, fluid geothermometry, and geophysical data provides an effective platform for evaluating the geothermal potential of respective structural plays. Recent studies focused on deep stratigraphic reservoirs indicate the best conditions for economically viable development are associated with thick sedimentary basins with low-thermal-conductivity sedimentary cap rocks overlying permeable host rocks (e.g. carbonates) and co-located with areas of high heat flow. Some of the factors that contribute to the potential for deep stratigraphic reservoirs and conventional structurally controlled geothermal systems apply to both types of resources, and in some places the potential for these two types of resources overlap in space, suggesting the potential for hybrid reservoirs (structurally controlled deep stratigraphic reservoirs). Effective and complete evaluation of geothermal potential in the Great Basin should include parameters that cover both types of resources. In this study, two areas with a combined area of 26,000 km 2 were evaluated for geothermal resource potential, equating to <4% of the total 680,000 km 2 size of the Great Basin region. Within these two study areas, 73 potential structural targets and 8 potential deep sedimentary target areas were identified. Four of the 73 potential structural target areas are associated with known thermal anomalies. All 73 structural target areas were ranked according to multiple data sets.

15 GEOTHERMAL ENERGY↗