Search NASA⌕ Search

SEARCH · Search NASA

Results for “bolometer detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Status and prospects of discovery of 0νββ decay with the CUORE detector

In this contribution we present the achievements of the CUORE experiment so far. It is the first tonne-scale bolometric detector and it is in stable data taking since 2018. We reached to collect about 1800 kg×yr of exposure of which more than 1 ton×year have been analysed. The CUORE detector is meant to search for the neutrinoless double β decay (0νββ) of the 130 Te isotope. This is a beyond Standard Model process which could establish the nature of the neutrino to be Dirac or a Majorana particle. It is an alternative mode of the two-neutrinos double β decay, a rare decay which have been precisely measured by CUORE in the 130 Te. We found no evidence of the 0νββ and we set a Bayesian lower limit of 2.2 ×10 25 yr on its half-life. The expertise achieved by CUORE set a milestone for any future bolometric detector, including CUPID, which is the planned next generation experiment searching for 0νββ with scintillating bolometers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CUORE: The first bolometric experiment at the ton scale for the search for neutrino-less double beta decay

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most massive bolometric experiment searching for neutrino-less double beta (0νββ) decay. The detector consists of an array of 988 TeO 2 crystals (742 kg) arranged in a compact cylindrical structure of 19 towers. Here, this paper will describe the CUORE experiment, including the cryostat, and present the detector performance during the first year of running. Additional detail will describe the effort made in improving the energy resolution in the 130 Te 0νββ decay region of interest (ROI) and the suppression of backgrounds. A description of work to lower the energy threshold in order to give CUORE the sensitivity to search for other rare events, such as dark matter, will also be provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Collaborative Research Towards a tonne-scale bolometer-based neutrinoless double beta decay experiment (Final Report)

Cryogenic bolometers are an excellent technology for neutrinoless double beta decay searches owing to their very high energy resolution and potential for high radiopurity. The current most advanced large-scale experiment using these detectors is the Cryogenic Underground Observatory for Rare Events (CUORE). The largest source of background in CUORE is degraded alpha particles, emitted from shallow depths of the detector holders, which can deposit a thermal energy signature similar to neutrinoless double beta decay. To mitigate this background, the CUPID concept (CUORE Upgrade with Particle IDentification) proposes to use scintillating cryogenic detectors. Detecting both the scintillation light and the thermal signal allows discrimination between alpha particle events and beta/gamma events. We report on the design and execution of R&D tests to optimize the design of the single detector module, in particular the scintillation light collection efficiency at cryogenic temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expected sensitivity to 128 Te neutrinoless double beta decay with the CUORE TeO 2 cryogenic bolometers

The CUORE experiment is a ton-scale array of TeO 2 cryogenic bolometers located at the underground Laboratori Nazionali del Gran Sasso of Istituto Nazionale di Fisica Nucleare (INFN), in Italy. The CUORE detector consists of 988 crystals operated as source and detector at a base temperature of ~ 10 mK. Such cryogenic temperature is reached and maintained by means of a custom built cryogen-free dilution cryostat, designed with the aim of minimizing the vibrational noise and the environmental radioactivity. The primary goal of CUORE is the search for neutrinoless double beta decay of 130 Te , but thanks to its large target mass and ultra-low background it is suitable for the study of other rare processes as well, such as the neutrinoless double beta decay of 128 Te. This tellurium isotope is an attractive candidate for the search of this process, due to its high natural isotopic abundance of 31.75%. The transition energy at (866.7 ± 0.7) keV lies in a highly populated region of the energy spectrum, dominated by the contribution of the two-neutrino double beta decay of 130 Te. As the first ton-scale infrastructure operating cryogenic TeO 2 bolometers in stable conditions, CUORE is able to achieve a factor > 10 higher sensitivity to the neutrinoless double beta decay of this isotope with respect to past direct experiments.

128-Te↗

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optically induced quantum transitions in direct probed mesoscopic NbSe 2 for prototypical bolometers

Superconducting transition-edge sensors (TES) have emerged as fascinating devices to detect broadband electromagnetic radiation with low thermal noise. The advent of metallic transition metal dichalcogenides, such as NbSe 2 , has also created an impetus to understand their low-temperature properties, including superconductivity. Interestingly, NbSe 2 -based sensor within the TES framework remains unexplored. In this work, direct-probed superconducting NbSe 2 absorbers led to a proof-of-concept demonstration for the transduction of incoming light to heat, where a thermodynamic superconducting phase transition in NbSe 2 was evident to switch it to the normal-state, when biased below its superconducting transition temperature. A wavelength-dependent response of its optical absorption properties was observed, based on the incident optical excitation source used. Furthermore, extensive optical characterization studies were conducted using Raman spectroscopy, where the in-plane and out-of-plane thermal conductivity was empirically determined. Our results open new possibilities for the use of NbSe 2 in superconducting radiation detectors, including in a TES framework

47 OTHER INSTRUMENTATION↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Simons Observatory: Design, Optimization, and Performance of Low-Frequency Detectors

The Simons Observatory (SO) is a cosmic microwave background (CMB) experiment located in the Atacama Desert in Chile that will make precise temperature and polarization measurements over six spectral bands ranging from 27 to 285 GHz. Three small aperture telescopes (SATs) and one large aperture telescope (LAT) will house ~60,000 detectors and cover angular scales between one arcminute and tens of degrees. We present the performance of the dichroic, low-frequency (LF) lenslet-coupled sinuous antenna transition-edge sensor (TES) bolometer arrays with bands centered at 27 and 39 GHz. The LF focal plane will primarily characterize Galactic synchrotron emission as a critical part of foreground subtraction from CMB data. We will discuss the design, optimization, and current testing status of these pixels.

79 ASTRONOMY AND ASTROPHYSICS↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Particle Response of Antenna-Coupled TES Arrays: Results from SPIDER and the Laboratory

Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce ‘glitches’ in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. Here, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Devices for Neutrino and Rare Particle Detection (Final Report)

This report summarizes the technical work completed under the DOE-QuanISED program. This grant allowed the MIT group --and associated groups on the project, including UMass Amherst and Argonne National Laboratory -- to explore the use of superconducting bolometers for the purpose of neutrino and low mass dark matter detection. These low threshold bolometric detection techniques have wide applicability in nuclear and particle physics, including searching for low mass weakly-interacting dark matter; detecting neutrinos via coherent neutrino scattering; searching for axions and nuclear non-proliferation. In addition, we explored how using techniques readily used by the quantum computing community–such as multiplexed microwave resonators and quantum amplifiers—could be used as a low noise readout scheme for an array of superconducting detectors. We briefly summarized the accomplishments under the project, and what future research directions have spawned from this research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗