Search NASA⌕ Search

SEARCH · Search NASA

Results for “buckling (C)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-term thermal aging of parylene conformal coating under high humidity and its effects on tin whisker mitigation

Usage of pure tin (Sn) or Sn-rich alloy in electronics industry is growing, which makes them more susceptible to the spontaneous growth of tin whiskers. The risk of having these whiskers can be dramatically mitigated by applying a conformal coating provided that it not only possesses excellent mechanical and adhesion properties but also maintains these properties throughout their service. Parylene C is commonly used as a conformal coating because of its favorable mechanical and physical properties, as well as superior conformal coverage. The purpose of this paper is to investigate the degradation of parylene C coating during the thermal aging in high humidity environment (85°C/85% relative humidity for up to 5000hrs) and its effect on the tin whisker mitigation capacity. It was observed that during aging at high temperature and high humidity (HTHH) environment, the oxidation occurs at early times, followed by bond scission, resulting in the loss of strength of the coating. Thinner parylene coating (12.5-μm-thick) had better coating adhesion on the silane-treated tin surface, so provided the better protection for tin whisker penetration than the thicker counterpart (25-μm-thick). After 2500hrs of aging, due to the degradation of the silane agent at the tin/parylene interface, the adhesion of the parylene coating was significantly weakened on the tin surface, which resulted in extensive corrosion of the tin solderpads. The loss of adhesion of the coating, along with the corrosion of the tin surface facilitated the tin whisker nucleation at the interface while the loss of mechanical strength and the brittleness made the coating easily penetrated by the growing whiskers. Tin whiskers with a smaller diameter were buckled and grew along the delaminated region while those with a larger diameter penetrated and continued to grow through the coating. Hence, the effectiveness of the parylene coatings on tin whisker mitigation is significantly reduced under long exposure to such high temperature and high humidity.

36 MATERIALS SCIENCE↗

Cristae formation is a mechanical buckling event controlled by the inner mitochondrial membrane lipidome

Cristae are high–curvature structures in the inner mitochondrial membrane (IMM) that are crucial for ATP production. While cristae–shaping proteins have been defined, analogous lipid–based mechanisms have yet to be elucidated. Here, we combine experimental lipidome dissection with multi–scale modeling to investigate how lipid interactions dictate IMM morphology and ATP generation. When modulating phospholipid (PL) saturation in engineered yeast strains, we observed a surprisingly abrupt breakpoint in IMM topology driven by a continuous loss of ATP synthase organization at cristae ridges. We found that cardiolipin (CL) specifically buffers the inner mitochondrial membrane against curvature loss, an effect that is independent of ATP synthase dimerization. To explain this interaction, we developed a continuum model for cristae tubule formation that integrates both lipid and protein–mediated curvatures. This model highlighted a snapthrough instability, which drives IMM collapse upon small changes in membrane properties. We also showed that cardiolipin is essential in low–oxygen conditions that promote PL saturation. These results demonstrate that the mechanical function of cardiolipin is dependent on the surrounding lipid and protein components of the IMM.

59 BASIC BIOLOGICAL SCIENCES↗

NDSE Static Series V & VI Test Results

The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Large spin-driven dielectric response and magnetoelectric coupling in the buckled honeycomb $Fe_4Nb_2O_9$

Here, we present the significant spin-driven dielectric anomaly (~40% drop) and magnetoelectric coupling near the magnetic ordering temperature in single crystal $Fe_4Nb_2O_9$ . By combining neutron and x-ray single crystal diffraction techniques, we unambiguously determined its magnetic symmetry and studied the structural phase transition at $T_S$ = 70 K. The temperature-dependent static dielectric constant is strongly anisotropic, rendering two dielectric anomalies along the $a$ axis in the hexagonal lattice with the first one coupled to the magnetic ordering around $T_N$ = 97 K and the second one accompanying with a first-order structural transition around $T_S$ = 70 K. Below $T_N$, we found that the anomalous dielectric constant is practically proportional to the square of the magnetic moment from neutron diffraction data, indicating that the exchange striction is likely responsible for the strong spin-lattice coupling. Magnetic-field-induced magnetoelectric coupling was observed and is compatible with the determined magnetic structure that is characteristic of antiferromagnetically arranged ferromagnetic chains in the honeycomb plane. We propose that such magnetic symmetry should be immune to external magnetic fields to some extent favored by the freedom of rotation of moments in the honeycomb plane, laying out a promising system to control the magnetoelectric properties by magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗