Search NASA⌕ Search

SEARCH · Search NASA

Results for “caffeine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

ISO_Fortran_binding_m v0.1.0

The Fortran programming language standard defines a broad feature set supporting the interoperability of Fortran programs with program written according to the C programming language standard. Among Fortran's C-interoperability features is a a C header file "ISO_Fortran_binding.h" This header file defines the interface to various C data structures and functions that C programs may use to access Fortran data entities. The ISO_Fortran_binding_m software defines a native Fortran module that presents an interface to these same data structures and functions. ISO_Fortran_bind_m thus enables Fortran programs to access and manipulate Fortran entities in ways that precisely mirror what C programs can do using ISO_Fortran_binding.h. ISO_Fortran_binding_m facilitates writing portable standard-conforming Fortran programs that emulate non-interoperable features, e.g., dynamic polymorphism, in a standard-conforming interoperable way similar but broader than what is demonstrated in Berkeley Lab's Caffeine software [1]. ISO_Fortran_binding_m also enables a Fortran programmer to extend Fortran's capabilities to emulate certain C functionality such as memory address arithmetic or computing C's "sizeof" function. [1] https://github.com/BerkeleyLab/caffeine/blob/213e3df1c319f0663306354414f352acda42a24f/src/caffeine/collective_subroutines/co_reduce_s.f90#L88 [2] https://github.com/BerkeleyLab/ISO_Fortran_binding_m/blob/0c585362bb4f2c72cf9049c800a7115b529ec533/src/iso_fortran_binding_m.F90#L196

Rouson, Damian↗

Agile Acceleration of LLVM Flang Support for Fortran 2018 Parallel Programming

The LLVM Flang compiler ("Flang") is currently Fortran 95 compliant, and the frontend can parse Fortran 2018. However, Flang does not have a comprehensive 2018 test suite and does not fully implement the static semantics of the 2018 standard. We are investigating whether agile software development techniques, such as pair programming and test-driven development (TDD), can help Flang to rapidly progress to Fortran 2018 compliance. Because of the paramount importance of parallelism in high-performance computing, we are focusing on Fortran’s parallel features, commonly denoted “Coarray Fortran.” We are developing what we believe are the first exhaustive, open-source tests for the static semantics of Fortran 2018 parallel features, and contributing them to the LLVM project. A related effort involves writing runtime tests for parallel 2018 features and supporting those tests by developing a new parallel runtime library: the CoArray Fortran Framework of Efficient Interfaces to Network Environments (Caffeine).

Rasmussen, Katherine↗

Parallel Runtime Interface for Fortran (PRIF): A Multi-Image Solution for LLVM Flang

Fortran compilers that provide support for Fortran’s native parallel features often do so with a runtime library that depends on details of both the compiler implementation and the communication library, while others provide limited or no support at all. This paper introduces a new generalized interface that is both compiler- and runtime-library-agnostic, providing flexibility while fully supporting all of Fortran’s parallel features. The Parallel Runtime Interface for Fortran (PRIF) was developed to be portable across shared- and distributed-memory systems, with varying operating systems, toolchains and architectures. It achieves this by defining a set of Fortran procedures corresponding to each of the parallel features defined in the Fortran standard that may be invoked by a Fortran compiler and implemented by a runtime library. PRIF aims to be used as the solution for LLVM Flang to provide parallel Fortran support. This paper also briefly describes our PRIF prototype implementation: Caffeine.

Bonachea, Dan↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Open-Source Data Analysis Tool for Spectral Small-Angle X-ray Scattering Using Spectroscopic Photon-Counting Detector

Spectral small-angle X-ray scattering (sSAXS) is a powerful technique for material characterization from thicker samples by capturing elastic X-ray scattering data in angle- and energy-dispersive modes at small angles. This approach is enabled by the use of a 2D spectroscopic photon-counting detector that provides energy and position information of scattered photons when a sample is irradiated by a polychromatic X-ray beam. Here, we describe an open-source tool with a graphical interface for analyzing sSAXS data obtained from a 2D spectroscopic photon-counting detector with a large number of energy bins. The tool takes system geometry parameters and raw detector data to output 1D scattering patterns and a 2D spatially-resolved scattering map in the energy range of interest. We validated these features using data from samples of caffeine powder with well-known scattering peaks. This open-source tool will facilitate sSAXS data analysis for various material characterization applications.

Chemistry↗

Isolation and characterization of ultraviolet light-sensitive mutants of the blue-green alga Anacystis nidulans.

Three independently isolated ultraviolet light sensitive (uvs) mutants of Anacystis nidulans were characterized. Strain uvs-1 showed the highest sensitivity to UV by its greatly reduced photoreactivation capacity following irradiation. Pretreatment with caffeine suppressed the dark-survival curve of strain uvs-1, thus indicating the presence of excision enzymes involved in dark repair. Under 'black' and 'white' illumination, strain uvs-1 shows photorecovery properties comparable with wild-type cultures. Results indicate that strains uvs-1, uvs-35, and uvs-88 are probably genetically distinct UV-sensitive mutants.

Asato, Y.↗

Crew factors in flight operations 6: Psychophysiological responses to helicopter operations

Thirty-two helicopter pilots were studied before, during, and after 4-5 day trips providing support services from Aberdeen, Scotland, to rigs in the North Sea oil fields. Early on-duty times obliged subjects to wake up 1.5 hours earlier on trip days than on pretrip days. Consequently, they slept nearly an hour less per night on trips. They reported more fatigue on post-trip days than on pretrip days, suggesting a cumulative effect of duty-related activities and sleep loss. Fatigue and negative affect were higher, and activation lower, by the end of trip days than by the end of pretrip days. The earlier a subject went on duty, the lower his activation by the end of the day. Caffeine consumption increased 42 percent on trip days. The incidence of headache doubled, of back pain increased twelve fold, and of burning eyes quadrupled. In the aircraft studied, thermal discomfort and high vibration levels were common. The longer pilots remained on duty, the more negative their mood became.

Gander, Philippa H.↗

Crew factors in flight operations 2: Psychophysiological responses to short-haul air transport operations

Seventy-four pilots were monitored before, during, and after 3- or 4-day commercial short-haul trip patterns. The trips studied averaged 10.6 hr of duty per day with 4.5 hr of flight time and 5.5 flight segments. The mean rest period lasted 12.5 hr and occurred progressively earlier across successive days. On trip nights, subjects took longer to fall asleep, slept less, woke earlier, and reported lighter, poorer sleep with more awakenings than on pretrip nights. During layovers, subjective fatigue and negative affect were higher, and positive affect and activation lower, than during pretrip, in-flight, or posttrip. Pilots consumed more caffeine, alcohol, and snacks on trip days than either pretrip or posttrip. Increases in heart rate over mid-cruise were observed during descent and landing, and were greater for the pilot flying. Heart-rate increases were greater during takeoff and descent under instrument meteorological conditions (IMC) than under visual meteorological conditions (VMC). The following would be expected to reduce fatigue in short-haul operations: regulating duty hours, as well as flight hours; scheduling rest periods to begin at the same time of day, or progressively later, across the days of a trip; and educating pilots about alternatives to alcohol as a means of relaxing before sleep.

Gander, Philippa H.↗

An ATM-independent S-phase checkpoint response involves CHK1 pathway

After exposure to genotoxic stress, proliferating cells actively slow down the DNA replication through a S-phase checkpoint to provide time for repair. We report that in addition to the ataxia-telangiectasia mutated (ATM)-dependent pathway that controls the fast response, there is an ATM-independent pathway that controls the slow response to regulate the S-phase checkpoint after ionizing radiation in mammalian cells. The slow response of S-phase checkpoint, which is resistant to wortmannin, sensitive to caffeine and UCN-01, and related to cyclin-dependent kinase phosphorylation, is much stronger in CHK1 overexpressed cells, and it could be abolished by Chk1 antisense oligonucleotides. These results provide evidence that the ATM-independent slow response of S-phase checkpoint involves CHK1 pathway.

Non-NASA Center↗

Novel method to assess gastric emptying in humans: the Pellet Gastric Emptying Test

To further validate the Pellet Gastric Emptying Test (PGET) as a marker of gastric emptying, a randomized, four-way crossover study was conducted with 12 healthy subjects. The study consisted of oral co-administration of enteric coated caffeine (CAFF) and acetaminophen (APAP) pellets in four treatment phases: Same Size (100 kcal), Fasted, Small Liquid Meal (100 kcal), and Standard Meal (847 kcal). The time of first appearance of measurable drug marker in plasma, t(initial), was taken as the emptying time for the markers. Co-administration of same size enteric coated pellets of CAFF and APAP (0.7 mm in diameter) revealed no statistically significant differences in t(initial) values indicating that emptying was dependent only on size and not on chemical make-up of the pellets. Co-administration of different size pellets indicated that the smaller 0.7-mm diameter (CAFF) pellets were emptied and absorbed significantly earlier than the larger 3.6-mm diameter (APAP) pellets with both the Small Liquid Meal (by 35 min) and the Standard Meal (by 33 min) (P<0.05). The differences in emptying of the pellets were not significant in the Fasted Phase. The results suggest that the pellet gastric emptying test could prove useful in monitoring changes in transit times in the fasted and fed states and their impact on drug absorption.

NASA Discipline Regulatory Physiology↗

Impaired driving performance in shiftworkers: the role of the circadian system in a multifactorial model

A substantial and growing percentage of the U.S. work force now works on a rotating shift schedule. The repeated changes in sleep-wake, meal and work times inherent in such schedules conflict with the dictates of the internal biological clock and have adverse consequences for the health of the shiftworker population. An important consequence of this conflict is impaired performance, both on and off the job, as indexed by the increased incidence of motor vehicle accidents in shift workers. In this paper we report the results of a survey administered to rotating shift and straight day workers at a manufacturing plant in the eastern U.S. This survey documents an increased incidence of motor vehicle accidents or "near misses" in which sleepiness was implicated as a cause by the respondent. Complaints of poor sleep and increased sleepiness were also significantly more common in shiftworkers than day workers. Last, shiftworkers reported higher caffeine and alcohol consumption, and were more likely to use alcohol as a sleep aid. Although causal links cannot be established using these associative observations alone, previously reported experience with alteration of shift schedules, improvement of levels of alertness, and reduction in adverse performance outcomes corroborate the possibility of a causal link and suggest potential interventions.

NASA Discipline Regulatory Physiology↗

The radioresistance to killing of A1-5 cells derives from activation of the Chk1 pathway

Checkpoints respond to DNA damage by arresting the cell cycle to provide time for facilitating repair. In mammalian cells, the G(2) checkpoint prevents the Cdc25C phosphatase from removing inhibitory phosphate groups from the mitosis-promoting kinase Cdc2. Both Chk1 and Chk2, the checkpoint kinases, can phosphorylate Cdc25C and inactivate its in vitro phosphatase activity. Therefore, both Chk1 and Chk2 are thought to regulate the activation of the G(2) checkpoint. Here we report that A1-5, a transformed rat embryo fibroblast cell line, shows much more radioresistance associated with a much stronger G(2) arrest response when compared with its counterpart, B4, although A1-5 and B4 cells have a similar capacity for nonhomologous end-joining DNA repair. These phenotypes of A1-5 cells are accompanied by a higher Chk1 expression and a higher phosphorylation of Cdc2. On the other hand, Chk2 expression increases slightly following radiation; however, it has no difference between A1-5 and B4 cells. Caffeine or UCN-01 abolishes the extreme radioresistance with the strong G(2) arrest and at the same time reduces the phosphorylation of Cdc2 in A1-5 cells. In addition, Chk1 but not Chk2 antisense oligonucleotide sensitizes A1-5 cells to radiation-induced killing and reduces the G(2) arrest of the cells. Taken together these results suggest that the Chk1/Cdc25C/Cdc2 pathway is the major player for the radioresistance with G(2) arrest in A1-5 cells.

NASA Discipline Radiation Health↗

The pressor response to water drinking in humans : a sympathetic reflex?

BACKGROUND: Water drinking increases blood pressure profoundly in patients with autonomic failure and substantially in older control subjects. The mechanism that mediates this response is not known. METHODS AND RESULTS: We studied the effect of drinking tap water on seated blood pressure in 47 patients with severe autonomic failure (28 multiple system atrophy [MSA], 19 pure autonomic failure patients [PAF]). Eleven older controls and 8 young controls served as control group. We also studied the mechanisms that could increase blood pressure with water drinking. Systolic blood pressure increased profoundly with water drinking, reaching a maximum of 33+/-5 mm Hg in MSA and 37+/-7 in PAF mm Hg after 30 to 35 minutes. The pressor response was greater in patients with more retained sympathetic function and was almost completely abolished by trimethaphan infusion. Systolic blood pressure increased by 11+/-2.4 mm Hg in elderly but not in young controls. Plasma norepinephrine increased in both groups. Plasma renin activity, vasopressin, and blood volume did not change in any group. CONCLUSIONS: Water drinking significantly and rapidly raises sympathetic activity. Indeed, it raises plasma norepinephrine as much as such classic sympathetic stimuli as caffeine and nicotine. This effect profoundly increases blood pressure in autonomic failure patients, and this effect can be exploited to improve symptoms due to orthostatic hypotension. Water drinking also acutely raises blood pressure in older normal subjects. The pressor effect of oral water is an important yet unrecognized confounding factor in clinical studies of pressor agents and antihypertensive medications.

Non-NASA Center↗

[Determination of six main components in compound theophylline tablet by convolution curve method after prior separation by column partition chromatography]

On a partition chromatographic column in which the support is Kieselguhr and the stationary phase is sulfuric acid solution (2 mol/L), three components of compound theophylline tablet were simultaneously eluted by chloroform and three other components were simultaneously eluted by ammonia-saturated chloroform. The two mixtures were determined by computer-aided convolution curve method separately. The corresponding average recovery and relative standard deviation of the six components were as follows: 101.6, 1.46% for caffeine; 99.7, 0.10% for phenacetin; 100.9, 1.31% for phenobarbitone; 100.2, 0.81% for theophylline; 99.9, 0.81% for theobromine and 100.8, 0.48% for aminopyrine.

NASA Program Flight↗

Effectiveness and duration of intramuscular antimotion sickness medications

Motion sickness inhibits gastric motility, making the oral route ineffective for medications. The intramuscular route is an effective alternative. The rotating chair was used to produce the M 111 level of motion sickness on the Graybiel Symptom Scale. The intramuscular medications given 30 minutes before rotation were compared with placebo (saline, 1 mL) for effectiveness and duration in increasing the number of tolerated head movements. Average placebo number of head movements was 294. Promethazine 25 mg increased head movements by 78% (P < .05), with a duration of 12 hours. Scopolamine 0.2 mg increased head movements by 91% (P < .05), with a duration of 4 hours. The effect of caffeine 250 mg and ephedrine 25 mg was not significant. When combined with scopolamine, ephedrine produced an 32% additive effect. Scopolamine 0.08 mg, 0.1 mg, and 0.2 mg and also promethazine 12.5 mg and 25 mg were significant (P < .05). Promethazine appears to be the drug of choice for intramuscular use because of a longer duration and a high level of effectiveness. Scopolamine was of high effectiveness, but had a duration of 4 hours. It was eight times as potent by the intramuscular as by the oral route.

Non-NASA Center↗

Application of Laser Mass Spectrometry to Art and Archaeology

REMPI laser mass spectrometry is a combination of resonance enhanced multiphoton ionization spectroscopy and time of flight mass spectrometry, This technique enables the collection of mass specific optical spectra as well as of optically selected mass spectra. Analytes are jet-cooled by entrainment in a molecular beam, and this low temperature gas phase analysis has the benefit of excellent vibronic resolution. Utilizing this method, mass spectrometric analysis of historically relevant samples can be simplified and improved; Optical selection of targets eliminates the need for chromatography while knowledge of a target's gas phase spectroscopy allows for facile differentiation of molecules that are in the aqueous phase considered spectroscopically indistinguishable. These two factors allow smaller sample sizes than commercial MS instruments, which in turn will require less damage to objects of antiquity. We have explored methods to optimize REMPI laser mass spectrometry as an analytical tool to archaeology using theobromine and caffeine as molecular markers in Mesoamerican pottery, and are expanding this approach to the field of art to examine laccaic acid in shellacs.

Gulian, Lase Lisa E.↗