Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, Michael P.↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, M. P.↗

Fiber optic microphone having a pressure sensing reflective membrane and a voltage source for calibration purpose

A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a back plate for damping membrane motion. The back plate further provides a means for on-line calibration of the microphone.

Zuckerwar, Allan J.↗

MODIS. Volume 2: MODIS level 1 geolocation, characterization and calibration algorithm theoretical basis document, version 1

The EOS Moderate Resolution Imaging Spectrometer (MODIS) is being developed by NASA for flight on the Earth Observing System (EOS) series of satellites, the first of which (EOS-AM-1) is scheduled for launch in 1998. This document describes the algorithms and their theoretical basis for the MODIS Level 1B characterization, calibration, and geolocation algorithms which must produce radiometrically, spectrally, and spatially calibrated data with sufficient accuracy so that Global change research programs can detect minute changes in biogeophysical parameters. The document first describes the geolocation algorithm which determines geodetic latitude, longitude, and elevation of each MODIS pixel and the determination of geometric parameters for each observation (satellite zenith angle, satellite azimuth, range to the satellite, solar zenith angle, and solar azimuth). Next, the utilization of the MODIS onboard calibration sources, which consist of the Spectroradiometric Calibration Assembly (SRCA), Solar Diffuser (SD), Solar Diffuser Stability Monitor (SDSM), and the Blackbody (BB), is treated. Characterization of these sources and integration of measurements into the calibration process is described. Finally, the use of external sources, including the Moon, instrumented sites on the Earth (called vicarious calibration), and unsupervised normalization sites having invariant reflectance and emissive properties is treated. Finally, algorithms for generating utility masks needed for scene-based calibration are discussed. Eight appendices are provided, covering instrument design and additional algorithm details.

Barker, John L.↗

An electronically gated gamma and X-ray calibration scheme.

The construction and use are described for a radioactive calibration source that produces an electronic gating pulse when a calibration gamma ray is emitted and makes it possible to employ this source in many calibration or stabilizing tasks without the disadvantage of having to introduce extra counts into the unknown spectrum. The described source is radioactively safe, easy to construct, and has the ability of producing gating efficiencies as high as 98%.

Forrest, D. J.↗

Atmospheric correction of TIMS data

The Thermal Infrared Multispectral Scanner (TIMS) is a unique sensor for two reasons, it is multispectral in the thermal-infrared and it has on board, active calibration sources. The existence of the calibration permits the recorded DNs to be converted unambiguously to absolute energy units. However, to relate the data to energy originating from a target on the ground it is necessary to remove the atmospheric contribution to the signal, specifically its transmittance and emittance. These can be obtained fairly easily by use of the atmospheric model provided by LOWTRAN-6 and the data from the U.S. Weather Service network of bidaily radiosondes. Using these data with the TIMS responsivity curves an equation can be obtained which permits the unambiguous correction of the TIMS data for the atmosphere.

Rickman, Doug↗

Isophot - Photometric Calibration of Point Sources

We discuss the photometric calibration of ISOPHOT for point sources in the wavelength range from 3.2 to 240 ??or the aperture photometer and the FIR camera section.

Infrared instrumentation ISO ISOPHOT calibration i↗

The Nimbus 4 infrared spectroscopy experiment. I - Calibrated thermal emission spectra.

Measurement of the infrared spectrum of the earth and atmosphere between 400 and 1600/cm. In an effort to obtain spectra with high absolute accuracy, it was necessary to incorporate many factors into the calibration, including small departures from unity in the emissivity of the on-board calibration source, imbalance between cold and warm calibration ports, and effects due to orbital variations in instrument temperature. The inclusion of such higher order corrections, along with careful data screening processes, has ensured a high quality data set that can be used in a variety of geophysical and meteorological investigations. Representative samples of data are presented that illustrate the behavior of the thermal emission spectra under a variety of conditions encountered in a typical orbit, including extremes in temperature, surface reststrahlung (or residual ray) effects, and various types of cloud conditions.

Hanel, R. A.↗

Two XTE A01 Projects: A Multifrequency Study of Circinus X-1 and a Search for Microsecond Variability From Bright Galactic X-Ray Source

This final report describes the research of a single common portion of the above-named two projects, conducted by G. Jernigan, i.e., the theory for a new method, a variation of a Kolmogorov-Smirnov test, for determining the fastest variability present in an X-ray source. The current phase involves testing the newly developed code on real example sources (CYG X1). Unfortunately, there are no calibration sources for testing the code, which therefore required the development of an X-ray source simulation code. The goal is to evaluate the sensitivity of the code for the detection of a range of different types of variability (bursts, pulsations, etc.).

Jernigan, Garrett↗

Thermal infrared array, phase 1. Volume 1: Technical

The recommended design configuration for the focal plane array of a 1,000 element linear pushbroom system consists of 32 modules; the complete configuration is built by butting together two 1024 linear arrays. Each of the linear arrays is formed by edge butting 16 modules together. By staggering the modules of the two rows, the channel outages which occur where the modules are edge butted can be eliminated. Two stages TDI operation is performed by the post processing electronics, which reduces the design complexity of the focal plane. Systems studies show that: (1) a single focal plane design can satisfy both the LEO and SEOS mission configurations; (2) available optical designs can meet mission goals; (3) MTF can be traded with optical complexity in a future study; (4) a chopping mechanism can be devised to modifying modulate radiation to a 4-inch focal plane as well as insert two calibration sources at the required frequencies for chopping and calibration; (5) radiative cooling technology should be suitable for a future sensor in either mission configuration; and (6) cold shielding is not a requirement.

Source record↗

The use of thematic mapper simulator calibration data for assessment of data quality

In flight calibration data collected from the thematic mapper simulator (TMS) were used to assess the quality of Earth scan data. The following results are indicated: (1) based on limited samples, individual TMS channels have noise which varies from channel to channel, but remains constant within a channel; (2) short term variations of more than 5% in the average values of calibration source responses indicate problems; and (3) absolute radiometric calibration is unlikely to be meaningful in a temporal sense due to single point calibration methods used.

Forman, M. L.↗

ISO Key Project: Exploring the full range of QUASAR/AGN properties

The PIA (PHOT Interactive Analysis) software was upgraded as new releases were made available by VILSPA. We have continued to analyze our data but, given the large number of still outstanding problems with the calibration and analysis (listed below), we remain unable to move forward on our scientific program. We have concentrated on observations with long (256 sec) exposure times to avoid the most extreme detector responsivity drift problems which occur with a change in observed flux level, ie. as one begins to observe a new target. There remain a significant number of problems with analyzing these data including: (1) the default calibration source (FCS) observations early in the mission were too short and affected by strong detector responsivity drifts; (2) the calibration of the FCS sources is not yet well-understood, particularly for chopped observations (which includes most of ours); (3) the detector responsivity drift is not well-understood and models are only now becoming available for fitting chopped data; (4) charged particle hits on the detector cause transient responsivity drifts which need to be corrected; (5) the "flat-field" calibration of the long-wavelength (array) detectors: C1OO, C200 leaves significant residual structure and so needs to be improved;(6) the vignetting correction, which affects detected flux levels in the array detectors, is not yet available; (7) the intra-filter calibrations are not yet available; and (8) the background above 60 microns has a significant gradient which results in spurious positive and negative "detections" in chopped observations. ISO Observation planning, conferences and talks, ground based observing and other grant related activities are also briefly discussed.

Wilkes, B.↗

Development of 3-5 THz Harmonic Mixer

There is a high need for 2 THz room temperaturedirect-detectorsharmonic-mixers to characterize THz opticalsources, phase lock THz-QCLs as LO sources for multi-pixelreceivers, and realize absolute frequency calibration sources forapplications in astrophysics, earth science, and remote sensing.Thus, we have developed a WM-52 (WR0.22) harmonic mixerfor the 3-5 THz operation. The design, fabrication and assemblyof the THz mixer are discussed.

Microwave Devices↗

Using DSCOVR EPIC as an Additional Calibration Reference to Radiometrically Scale the Geo Imagers for the NASA CERES Project

The NASA CERES project provides climate-quality observed TOA and calculated surface fluxes to the climate community. The CERES instruments are mounted on the Aqua, Terra, NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used alongside the VIIRS and MODIS based cloud properties necessary for converting CERES radiance observations into fluxes. The CERES SYN1deg product provides the regional hourly fluxes in between the Terra and Aqua/NOAA-20-CERES observations based on geostationary imager (GEO) radiances. The GEO radiances are radiometrically scaled to the MODIS or VIIRS calibration references. The GEO and MODIS inter-calibration events are limited by the Aqua-MODIS or VIIRS local equator crossing time of 1:30 PM. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth, and the Earth Polychromatic Imaging Camera (EPIC) instrument onboard DSCOVR has a constant view of the sunlit side of the Earth while taking images ranging from the UV to the NIR throughout the day. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that EPIC is radiometrically stable, which allows it to potentially be used as a transfer radiometer between imagers. This study will assess the viability of using EPIC as a consistent and stable calibration source for GEO imagers. EPIC will be inter-calibrated with Himawari-8 that has been radiometrically scaled with Aqua. The Himawari-8 based EPIC calibration gains will be verified by the EPIC calibration gains determined directly from Aqua-MODIS matches. The EPIC calibration gains based on Himawari-8 will be stratified by local time to determine any diurnal dependence of the GEO/EPIC calibration strategy.

C O Haney↗

A dynamic pressure source for the calibration of pressure transducers

A dynamic pressure source is described for producing sinusoidally varying pressures of up to 34 kPa zero to peak, over the frequency range of approximately 50 Hz to 2 kHz. The source is intended for the dynamic calibration of pressure transducers. The transducer to be calibrated is mounted near the base of the thick walled aluminum tube forming the vessel so that the pressure sensitive element is in contact with the liquid in the tube. A section of the tube is filled with small steel balls to damp the motion of the 10-St dimethyl siloxane working fluid in order to extend the useful frquency range to higher frequencies than would be provided by an undamped system. The dynamic response of six transducers provided by the sponsor was evaluated using the pressure sources; the results of these calibrations are given.

Vezzetti, C. F.↗