Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera mobility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

System Construction of the Stilbene Compact Neutron Scatter Camera

This report documents the construction of a stilbene-crystal-based compact neutron scatter camera. This system is essentially identical to the MINER (Mobile Imager of Neutrons for Emergency Responders) system previously built and deployed under DNN R&D funding,1 but with the liquid scintillator in the detection cells replaced by stilbene crystals. The availability of these two systems for side-by-side performance comparisons will enable us to unambiguously identify the performance enhancements provided by the stilbene crystals, which have only recently become commercially available in the large size required (3” diameter, 3” deep).

36 MATERIALS SCIENCE↗

Mine Rescue Robotics: Gemini-Scout - 18507

Gemini Scout is a mine rescue vehicle developed by Sandia National Laboratories to help locate and communicate with trapped miners following an accident. In a mining accident, first responders are working against a myriad of dangers to assess the situation and rescue trapped miners. The robot can enter potentially dangerous situations ahead of rescuers to evaluate hazardous environments and help them determine how operations should proceed. The Gemini Scout mitigates many of the potential dangers and allows exploration and assessment without further endangering individuals. The robotic vehicle can operate in hostile, debris strewn, dark, muddy, high temperature, and explosive environments. It has extreme ground mobility including operation in up to 18 inches of water and ability to traverse large rubble piles and cross railroad tracks. The vehicle provides gas and temperature sensing as well as pan, tilt, zoom color and thermal camera video streaming back to an operator in a safe zone. The extreme mobility of the vehicle and the modularity of the platform allowing easy integration of sensors are directly applicable to many needs within Waste Management. The development of Gemini Scout was funded by National Institute of Occupational Safety and Health (NIOSH) and the primary customer and certification entity was Mine Safety and Health Administration (MSHA). Lessons-learned during development and steps leading to certification are also applicable to the development of systems for unique Waste Management sites. (authors)

42 ENGINEERING↗

Estimating vehicle fuel economy from overhead camera imagery and application for traffic control

In this work, we explore the ability to estimate vehicle fuel consumption using imagery from overhead fisheye lens cameras deployed as traffic sensors. We utilize this information to simulate vision-based control of a traffic intersection, with a goal of improving fuel economy with minimal impact to mobility. We introduce the ORNL Overhead Vehicle Dataset (OOVD), consisting of a data set of paired, labeled vehicle images from a ground-based camera and an overhead fisheye lens traffic camera. The data set includes segmentation masks based on Gaussian mixture models for vehicle detection. We show the dataset utility through three applications: the estimate of fuel consumption based on segmentation bounding boxes, vehicle discrimination for those vehicles with largest bounding boxes, and a fine-grained classification on a limited number of vehicle makes and models using a pre-trained set of convolutional neural network models. We compare these results with estimates based on a large open-source data set based on web-scraped imagery. Finally, we show the utility of the approach using reinforcement learning in a traffic simulator using the open source Simulation of Urban Mobility (SUMO) package. Our results show the feasibility of the approach for controlling traffic lights for better fuel efficiency based solely on visual vehicle estimates from commercial, fisheye lens cameras.

Karnowski, Thomas↗

Understanding Detrimental and Beneficial Grain Boundary Effects in Halide Perovskites

Abstract Grain boundaries play a key role in the performance of thin‐film optoelectronic devices and yet their effect in halide perovskite materials is still not understood. The biggest factor limiting progress is the inability to identify grain boundaries. Noncrystallographic techniques can misidentify grain boundaries, leading to conflicting literature reports about their influence; however, the gold standard – electron backscatter diffraction (EBSD) – destroys halide perovskite thin films. Here, this problem is solved by using a solid‐state EBSD detector with 6000 times higher sensitivity than the traditional phosphor screen and camera. Correlating true grain size with photoluminescence lifetime, carrier diffusion length, and mobility shows that grain boundaries are not benign but have a recombination velocity of 1670 cm s −1 , comparable to that of crystalline silicon. Amorphous grain boundaries are also observed that give rise to locally brighter photoluminescence intensity and longer lifetimes. This anomalous grain boundary character offers a possible explanation for the mysteriously long lifetime and record efficiency achieved in small grain halide perovskite thin films. It also suggests a new approach for passivating grain boundaries, independent of surface passivation, to lead to even better performance in optoelectronic devices.

Adhyaksa, Gede W. P.↗

Three-dimensional reconstruction of dust particle trajectories in the NSTX

Highly mobile incandescent dust particles are routinely observed on NSTX using two fast cameras operating in the visible region. An analysis method to reconstruct dust particle trajectories in space using two fast cameras is presented in this paper. Position accuracies of a few millimeters depending on the particle's location have been achieved and particle velocities between 10 and 200 m/s have been observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional Reconstruction of Dust Particle Trajectories in the NSTX

Highly mobile incandescent dust particles are routinely observed on NSTX using two fast cameras operating in the visible region. An analysis method to reconstruct dust particle trajectories in space using two fast cameras is presented in this paper. Position accuracies of a few millimeters depending on the particle's location have been achieved and particle velocities between 10 and 200 m/s have been observed. 2008 American Institute of Physics. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Targeted Observations of Blowing Snow during SAIL (SAIL-TOBS) Field Campaign Report

Blowing snow research at high-latitude U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility observatories and mobile campaigns demonstrated the need for ground truth during falling and blowing snow events. The purpose of the Targeted Observations of Blowing Snow during SAIL (SAIL-TOBS) field campaign was to affordably deploy additional instruments to observe mixed-phase and frozen hydrometeors, including falling and blowing snow, during the second winter of the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign. Instruments included two installations of the Open Snowflake Camera for Research and Education (OSCRE), one at the Gothic, Colorado main site (second ARM Mobile Facility [AMF2]) and a second at the Kettle Ponds external field site in support of the Study of Precipitation, the Lower Atmosphere and Surface for Hydrometeorology (SPLASH) campaign. Two FlowCapt FC4 acoustic mass flux sensors were also deployed at AMF2 in proximity to OSCRE on top of the instrumented hill (Figure 1).

54 ENVIRONMENTAL SCIENCES↗

LANSCE Diagnostic Robot Localization

Los Alamos Neutron Science Center (LANSCE) operates a linear particle accelerator (LINAC) that is used for a number of scientific research projects. Due to the presence of harmful radiation, researchers are not allowed in the beam tunnel during operation. Since the beam tunnel is inaccessible, an autonomous mobile robot is to be developed and deployed in the tunnel, monitoring the accelerator during operation. The robot will present real time data for operators and scientists from sensors such as a video camera, thermal camera, microphones, and muon detectors; allowing for beam diagnostics previously unavailable. Localization is a fundamental step in autonomous navigation of mobile robots, answering the “where am I” question. For this project, an Extended Kalman Filter (EKF) algorithm is implemented as a positional estimator. The EKF relies on an odometric motion model to predict the robot’s position and LIDAR measurement data to update the robot’s position. The measurement model is based on v features extracted from the LIDAR point cluster using the Split-and-Merge algorithm, and the nearest neighbor algorithm associates the features to an a priori feature map of the beam tunnel. The predicted and measured positions are then joined using a weighted value by means of the Kalman gain. The effectiveness of this localization technique is demonstrated using the LabVIEW robotics simulator.

42 ENGINEERING↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part I - Environment Mapping

When characterizing facilities, advanced autonomous systems are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. One main focus of the research is the visual mapping of the environment.This paper presents a framework for the mapping aspect that utilizes lidar and SLAM technologies coupled with a monocular camera to create a point cloud of the environment. Upon completion, the present research work aims to provide an autonomous mobile robot the capability to localize itself and aid the user with visualizing the radiation data. Challenges: C++ node needs to properly synchronize image and point cloud data. 3D lidar has resolution of ± 3 cm. Proper camera calibration needed. Transforms need to be precise for proper alignment of image and point-cloud. Results: Voxelated point clouds. Accurate colors from calibrated cameras including details smaller than lidar resolution. Developed Robotics Operating System (ROS) package for ease of transfer to other robot platforms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OccuTherm: Occupant Thermal Comfort Inference using Body Shape Information

This repository contains the official data from a USDOE-funded project at Carnegie Mellon University and Bosch Research Pittsburgh. The primary goal of the project was to investigate the relationship between indoor commercial building occupant thermal comfort and various biometric and environmental predictors. We performed 77 individual comfort experiments, approved by our Institutional Review Board (IRB) and in satisfaction of participant consent guidelines. Our goal was to generate a dataset than enables comprehensive study of human thermal comfort preferences, in a commercial building environment, across a wide range of indoor environmental conditions. The data is comprised of the following feature groups: depth camera frames, biometrics sensor data, body shape information, subjective comfort data from the mobile device application, environmental sensor data from the commercial building HVAC system, and outdoor weather station data.

47 OTHER INSTRUMENTATION↗

Aerosol mobility imaging for rapid size distribution measurements

A parallel plate dimensional electrical mobility separator and laminar flow water condensation provide rapid, mobility-based particle sizing at concentrations typical of the remote atmosphere. Particles are separated spatially within the electrical mobility separator, enlarged through water condensation, and imaged onto a CCD array. The mobility separation distributes particles in accordance with their size. The condensation enlarges size-separated particles by water condensation while they are still within the gap of the mobility drift tube. Once enlarged the particles are illuminated by a laser. At a pre-selected frequency, typically 10 Hz, the position of all of the individual particles illuminated by the laser are captured by CCD camera. This instantly records the particle number concentration at each position. Because the position is directly related to the particle size (or mobility), the particle size spectra is derived from the images recorded by the CCD.

42 ENGINEERING↗

MINER - A Mobile Imager of Neutrons for Emergency Responders

We have developed a mobile fast neutron imaging platform to enhance the capabilities of emergency responders in the localization and characterization of special nuclear material. This mobile imager of neutrons for emergency responders (MINER) is based on the Neutron Scatter Camera, a large segmented imaging system that was optimized for large-area search applications. Due to the reduced size and power requirements of a man-portable system, MINER has been engineered to fit a much smaller form factor, and to be operated from either a battery or AC power. We chose a design that enabled omnidirectional (4π) imaging, with only a ~twofold decrease in sensitivity compared to the much larger neutron scatter cameras. The system was designed to optimize its performance for neutron imaging and spectroscopy, but it does also function as a Compton camera for gamma imaging. This document outlines the project activities, broadly characterized as system development, laboratory measurements, and deployments, and presents sample results in these areas. Additional information can be found in the documents that reside in WebPMIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ReLU, Sparseness, and the Encoding of Optic Flow in Neural Networks

Accurate self-motion estimation is critical for various navigational tasks in mobile robotics. Optic flow provides a means to estimate self-motion using a camera sensor and is particularly valuable in GPS- and radio-denied environments. The present study investigates the influence of different activation functions—ReLU, leaky ReLU, GELU, and Mish—on the accuracy, robustness, and encoding properties of convolutional neural networks (CNNs) and multi-layer perceptrons (MLPs) trained to estimate self-motion from optic flow. Our results demonstrate that networks with ReLU and leaky ReLU activation functions not only achieved superior accuracy in self-motion estimation from novel optic flow patterns but also exhibited greater robustness under challenging conditions. The advantages offered by ReLU and leaky ReLU may stem from their ability to induce sparser representations than GELU and Mish do. Our work characterizes the encoding of optic flow in neural networks and highlights how the sparseness induced by ReLU may enhance robust and accurate self-motion estimation from optic flow.

97 MATHEMATICS AND COMPUTING↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The feasibility of mobile computing for on-site inspection.

With over 5 billion cellphones in a world of 7 billion inhabitants, mobile phones are the most quickly adopted consumer technology in the history of the world. Miniaturized, power-efficient sensors, especially video-capable cameras, are becoming extremely widespread, especially when one factors in wearable technology like Apple s Pebble, GoPro video systems, Google Glass, and lifeloggers. Tablet computers are becoming more common, lighter weight, and power-efficient. In this report the authors explore recent developments in mobile computing and their potential application to on-site inspection for arms control verification and treaty compliance determination. We examine how such technology can effectively be applied to current and potential future inspection regimes. Use cases are given for both host-escort and inspection teams. The results of field trials and their implications for on-site inspections are discussed.

Horak, Karl Emanuel↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

Integrating Overhead Camera Imagery with Reinforcement Learning to Improve Fuel Economy Through Adaptive Traffic Control

Overhead cameras have been deployed for some time as a sensor for traffic control, with many advantages over conventional inductive loop sensors in terms of robustness, ease of installation, and simplicity with respect to maintenance. We explore the utility of such imagery (in particular, fisheye lens cameras) for intelligent traffic control in real-time using reinforcement learning, with a goal of improving fuel economy for the overall intersection and grid of intersections. We summarize our initial work in data collection and approach to ascertain the ability to visually sense vehicular fuel consumption using real-world data. We then describe our deep reinforcement learning topology to test adaptive control informed by the camera capabilities. Next, we tested the proof-of-concept through a variety of simulation scenarios using the Simulation of Urban Mobility (SUMO) traffic simulator, which included different estimates on vehicle classifications, different traffic distributions, and different traffic densities. Six different control policies were tested ranging from simple timing, to heuristic visual-based methods, to actual policies learned via the reinforcement learning approach. Our results demonstrate the feasibility of the approach for controlling traffic lights for better fuel efficiency based on visual vehicle estimates from commercial, fisheye lens cameras.

Karnowski, Thomas↗