Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High temperature electrolyzer/fuel cell power cycle: Preliminary design considerations

A model of a high temperature electrolyzer/fuel cell, hydrogen/oxygen, thermally regenerative power cycle is developed and used to simulate system performance for varying system parameters. Initial estimates of system efficiency, weight, and volume are provided for a one KWe module assuming specific electrolyzer and fuel cell characteristics, both current and future. Specific interest is placed on examining the system responses to changes in device voltage versus current density operating curves, and the associated optimum operating ranges. The performance of a solar-powered, space based system in low earth orbit is examined in terms of the light-dark periods requiring storage. The storage design tradeoffs between thermal energy, electrical energy, and hydrogen/oxygen mass storage are examined. The current technology module is based on the 1000 C solid oxide electrolyzer cell and the alkaline fuel cell. The Future Technology system examines benefits involved with developing a 1800K electrolyzer operating with an advanced fuel cell.

Morehouse, Jeffrey H.↗

High-temperature Solar Cell Development

The vast majority of space probes to date have relied upon photovoltaic power generation. If future missions designed to probe environments close to the sun (Figure 1) will be able to use such power generation, solar cells that can function at high temperatures, under high light intensity, and high radiation conditions must be developed. The significant problem is that solar cells lose performance at high temperatures.

Landis, Geoffrey A.↗

Rubber and alumina gaskets retain vacuum seal in high temperature EMF cell

Silicone rubber gasket and an alumina gasket retain a vacuum inside a high temperature EMF cell in which higher and lower density liquid metal electrodes are separated by an intermediate density fused salt electrolyte. This innovation is in use on a sodium bismuth regenerable EMF cell in which the fused salts and metals are at about 500 deg to 600 deg C.

Hesson, J. C.↗

Infrared spectroscopy and Mie scattering of acetylene aerosols formed in a low temperature diffusion cell

A method is described for forming and spectroscopically characterizing cryogenic aerosols formed in a low temperature gas cell. By adjusting the cell pressure, gas composition and flow rate, the size distribution of aerosol particles can be varied over a wide range. The combination of pressure and flow rate determine the residence time of the aerosols in the cell and hence the time available for the particles to grow. FTIR spectroscopy, over the range from 600/cm to 6000/cm, is used to characterize the aerosols. The particle size distribution can be varied so that, at one extreme, the spectra show only absorption features associated with the infrared active vibrational bands and, at the other, they display both absorption and Mie scattering. In the latter case, Mie scattering theory is used to obtain semiquantitative aerosol size distributions, which can be understood in terms of the interplay between nucleation and condensation. In the case of acetylene aerosols, the infrared spectra suggest that the particles exist in the high temperature cubic phase of the solid.

Dunder, T.↗

Extended Temperature Solar Cell Technology Development

Future NASA missions will require solar cells to operate both in regimes closer to the sun, and farther from the sun, where the operating temperatures will be higher and lower than standard operational conditions. NASA Glenn is engaged in testing solar cells under extended temperature ranges, developing theoretical models of cell operation as a function of temperature, and in developing technology for improving the performance of solar cells for both high and low temperature operation.

Landis, Geoffrey A.↗

Polybenzimidazole-Based Polymer Electrolyte Membranes for High-Temperature Fuel Cells: Current Status and Prospects

Polymer electrolyte membrane fuel cells (PEMFCs) expect a promising future in addressing the major problems associated with production and consumption of renewable energies and meeting the future societal and environmental needs. Design and fabrication of new proton exchange membranes (PEMs) with high proton conductivity and durability is crucial to overcome the drawbacks of the present PEMs. Acid-doped polybenzimidazoles (PBIs) carry high proton conductivity and long-term thermal, chemical, and structural stabilities are recognized as the suited polymeric materials for next-generation PEMs of high-temperature fuel cells in place of Nafion® membranes. This paper aims to review the recent developments in acid-doped PBI-based PEMs for use in PEMFCs. The structures and proton conductivity of a variety of acid-doped PBI-based PEMs are discussed. More recent development in PBI-based electrospun nanofiber PEMs is also considered. The electrochemical performance of PBI-based PEMs in PEMFCs and new trends in the optimization of acid-doped PBIs are explored.

25 ENERGY STORAGE↗

Fluoroester Co-Solvents for Low-Temperature Li+ Cells

Electrolytes comprising LiPF6 dissolved in alkyl carbonate/fluoroester mixtures have been found to afford improved low-temperature performance and greater high-temperature resilience in rechargeable lithium-ion electrochemical cells. These and other electrolytes comprising lithium salts dissolved mixtures of esters have been studied in continuing research directed toward extending the lower limit of operating temperatures of such cells. This research at earlier stages, and the underlying physical and chemical principles, were reported in numerous previous NASA Tech Briefs articles. The purpose of the present focus on high-temperature resilience in addition to low-temperature performance is to address issues posed by the flammability of the esters and, at temperatures near the upper end (about 55 C) of their intended operating temperature range, by their high chemical reactivity. As used here, high-temperature resilience signifies, loosely, a desired combination of low flammability of an electrolyte mixture and the ability of a cell that contains the mixture to sustain a relatively small loss of reversible charge/discharge capacity during storage in the fully charged condition at high temperature. The selection of fluoroesters for study as candidate electrolyte solvent components to increase high-temperature resilience was prompted in part by the observation that like other halogenated compounds, fluoroesters have low flammability. The fluoroesters investigated in this study include trifluoroethyl butyrate (TFEB), ethyl trifluoroacetate (ETFA), trifluoroethyl acetate (TFEA), and methyl pentafluoropropionate (MPFP). Solvent mixtures were prepared by mixing these fluoroesters with two other esters: ethylene carbonate (EC) and ethyl methyl carbonate (EMC).

Smart, Marshall↗

Machine learning for optimizing the manufacture and operation of intermediate temperature fuel cells

The project developed machine learning and artificial intelligence (ML/AI) methodologies for guiding and accelerating the materials design and processing of new high temperature proton conducing electrode ionomer binders and reinforced membranes for high-temperature proton exchange membrane fuel cell (HT-PEMFC; aka intermediate-temperature polymer electrolyte membrane fuel cells).

08 HYDROGEN↗

Parametric study of operating conditions of an SO 2 -depolarized electrolyzer

Large-scale hydrogen generation is needed to satisfy both existing commercial demands and the realization of a hydrogen economy. The hybrid sulfur cycle has the potential to meet this goal without the use of fossil fuels. The ability to model and predict how the electrolyzer step of the cycle is affected by independent and interdependent variables is vital to maximizing the efficiency of the overall cycle. Herein, we report that our parametric study of the SO 2 -depolarized electrolyzer, representing one half of the overall reaction cycle, has identified desirable conditions and will help guide further development for operation that will achieve the benchmarks for economic feasibility. We discuss the interactions among the inlet flow rates, applied current, and cell temperature and pressure, on the resulting cell voltage and acid concentration in the liquid product stream. For example, we find that using a sulfonated polybenzimidazole (s-PBI) membrane and a platinum catalyst, a constant current density of either 0.5 A cm -2 , 0.75 A cm -2 , or 1 A cm -2 with an acid concentration of 65 wt% H 2 SO 4 can be produced at a cell voltage of 0.59 V, 0.63 V, and 0.67 V, respectively, by maintaining a cell temperature of 130 °C, a pressure of 2 bar, and a water-to-SO 2 stoichiometry of 2.77. Finally, we discuss directions for future research based on the findings in this manuscript.

08 HYDROGEN↗

Variable temperature pressure cell for polycrystalline X-ray studies down to 2 K - Application to Bi

A variable pressure diamond anvil cell is described for operation at temperatures continuously variable from 300 down to 2 K and controllable within 10 mK. Polycrystalline X-ray data are collected from the pressure cavity by means of either (1) standard photographic techniques, (2) diffractometer measurements, or (3) energy dispersive diffractometry. The facility has been used to examine parts of the phase diagram of Bi. Results from this study indicate that the Bi-I and Bi-III structures are retained to low temperatures; however, there is no evidence to support a structural transition from Bi-V to Bi-VIII.

Skelton, E. F.↗

High Temperature Solar Cell Development

The majority of satellites and near-earth probes developed to date have used photovoltaic arrays for power generation. If future mission to probe environments close to the sun will be able to use photovoltaic power, solar cells that can function at high temperatures, under high light intensity, and high radiation conditions must be developed. In this paper, we derive the optimum bandgap as a function of the operating temperature.

Landis, Geoffrey A.↗

Mixed-Salt/Ester Electrolytes for Low-Temperature Li+ Cells

Electrolytes comprising, variously, LiPF6 or LiPF6 plus LiBF4 dissolved at various concentrations in mixtures of alkyl carbonates and alkyl esters have been found to afford improved low-temperature performance in rechargeable lithium-ion electrochemical cells. These and other electrolytes have been investigated in a continuing effort to extend the lower limit of operating temperatures of such cells. This research at earlier stages, and the underlying physical and chemical principles, were reported in numerous previous NASA Tech Briefs articles, the most recent being Ester-Based Electrolytes for Low-Temperature Li-Ion Cells (NPO-41097), NASA Tech Briefs, Vol. 29, No. 12 (December 2005), page 59. The ingredients of the solvent mixtures include ethylene carbonate (EC), ethyl methyl carbonate (EMC), methyl butyrate (MB), and methyl propionate (MP). The electrolytes were placed in Li-ion cells containing carbon anodes and LiNi0.8Co0.2O2 cathodes, and the electrical performances of the cells were measured over a range of temperatures down to 60 C. The electrolytes that yielded the best low-temperature performances were found to consist, variously, of 1.0 M LiPF6 + 0.4 M LiBF4 or 1.4 LiPF6 in 1EC + 1EMC + 8MP or 1EC + 1EMC + 8MB, where the concentrations of the salts are given in molar units and the proportions of the solvents are by relative volume.

Smart, Marshall↗

Cracked Solar Cell Performance Depends on Module Temperature

When cells in a crystalline silicon photovoltaic module crack, packaging materials hold the fragments together. Changes in module temperature cause cell fragments to move, allowing cracked metallization to lose and regain contact. We intentionally cracked cells in commercial PV modules and characterized the modules’ temperature-dependent electroluminescence (EL) response. Here we show that (1) metallization makes contact across cracks in a way that is temperature dependent and (2) this contact is not a function of temperature, but is hysteretic. We expect that any electro-optical characterization made at a single temperature will be misleading as to the effects of cracked cells at different temperatures. And we expect that a single temperature sweep cannot fully characterize the temperature dependence of electro-optical performance of modules with cracked cells.

crack↗