Control circuit ensures solar cell operation at maximum power

Control circuit enables a solar cell power supply to deliver maximum electrical power to a load. It senses the magnitude of the slope of the voltage-current characteristic curve and compares it to a reference voltage which represents the slope corresponding to the desired operating limits.

Paulkovich, J.↗

Photographic films as remote sensors for measuring albedos of terrestrial surfaces

To test the feasibility of remotely measuring the albedos of terrestrial surfaces from photographic images, an inquiry was carried out at ground level using several representative common surface targets. Problems of making such measurements with a spectrally selective sensor, such as photographic film, have been compared to previous work utilizing silicon cells. Two photographic approaches have been developed: a multispectral method which utilizes two or three photographic images made through conventional multispectral filters and a single shot method which utilizes the broad spectral sensitivity of black and white infrared film. Sensitometry related to the methods substitutes a Log Albedo scale for the conventional Log Exposure for creating characteristic curves. Certain constraints caused by illumination goemetry are discussed.

Pease, S. R.↗

Parametric investigation of enclosed keeper discharge characteristics

Volt-ampere discharge characteristics of an enclosed keeper hollow cathode discharge were measured as a function of the mercury flow rate and external circuit impedance. Discharge currents were varied from 0 to 1 ampere and voltages were 7 to 39 volts. Batteries and a vacuum tube control circuit were used to obtain characteristics curves that were independent of power supply impedance. Variation of the neutral flow results in changes in the discharge which interact with the impedance of the external circuit, and under some conditions, give rise to multiple operating points.

Sheheen, T. W.↗

Investigation of hollow cathode performance for 30-cm thrusters

A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, insert position, emission current, cathode temperature, orifice diameter, and mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes. The results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages are also presented.

Mirtich, M. J.↗

Use of ERTS-1 data: Summary report of work on ten tasks

The author has identified the following significant results. Depth mapping's for a portion of Lake Michigan and at the Little Bahama Bank test site have been verified by use of navigation charts and on-site visits. A thirteen category recognition map of Yellowstone Park has been prepared. Model calculation of atmospheric effects for various altitudes have been prepared. Radar, SLAR, and ERTS-1 data for flooded areas of Monroe County, Michigan are being studied. Water bodies can be reliably recognized and mapped using maximum likelihood processing of ERTS-1 digital data. Wetland mapping has been accomplished by slicing of single band and/or ratio processing of two bands for a single observation date. Both analog and digital processing have been used to map the Lake Ontario basin using ERTS-1 data. Operating characteristic curves were developed for the proportion estimation algorithm to determine its performance in the measurement of surface water area. The signal in band MSS-5 was related to sediment content of waters by modelling approach and by relating surface measurements of water to processed ERTS data. Radiance anomalies in ERTS-1 data could be associated with the presence of oil on water in San Francisco Bay, but the anomalies were of the same order as those caused by variations in sediment concentration and tidal flushing.

Thomson, F. J.↗

Monitoring forest land from high altitude and from space

The significant findings are reported for remote sensing of forest lands conducted during the period October 1, 1965 to December 31, 1972. Forest inventory research included the use of aircraft and space imagery for forest and nonforest land classification, and land use classification by automated procedures, multispectral scanning, and computerized mapping. Forest stress studies involved previsual detection of ponderosa pine under stress from insects and disease, bark bettle infestations in the Black Hills, and root disease impacts on forest stands. Standardization and calibration studies were made to develop a field test of an ERTS-matched four-channel spectrometer. Calibration of focal plane shutters and mathematical modeling of film characteristic curves were also studied. Documents published as a result of all forestry studies funded by NASA for the Earth Resources Survey Program from 1965 through 1972 are listed.

Source record↗

Diagnostics of the technical condition of antifriction bearings

Shock pulse measurements that express the characteristic curves of rotational bearing resistance are used to diagnose possible deficiencies. Spectral analysis of frequency vibration tracings establishes probable causes for various anomalies in the geometric shape, surface frequency, contamination, etc.

Vitkute, A. E. Y.↗

Investigation of hollow cathode performance for 30-cm thrusters

A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, the insert position, the emission current, the cathode temperature, the orifice diameter, and the mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes of interest. Also presented are the results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages.

Mirtich, M. J.↗

Experimental Investigation of Average Heat-Transfer and Friction Coefficients for Air Flowing in Circular Tubes Having Square-Thread-Type Roughness

An investigation of forced-convection heat transfer and associated pressure drops was conducted with air flowing through electrically heated Inconel tubes having various degrees of square-thread-type roughness, an inside diameter of 1/2 inch, and a length of 24 inches. were obtained for tubes having conventional roughness ratios (height of thread/radius of tube) of 0 (smooth tube), 0.016, 0.025, and 0.037 over ranges of bulk Reynolds numbers up to 350,000, average inside-tube-wall temperatures up to 1950deg R, and heat-flux densities up to 115,000 Btu per hour per square foot. Data The experimental data showed that both heat transfer and friction increased with increase in surface roughness, becoming more pronounced with increase in Reynolds number; for a given roughness, both heat transfer and friction were also influenced by the tube wall-to-bulk temperature ratio. Good correlation of the heat-transfer data for all the tubes investigated was obtained by use of a modification of the conventional Nusselt correlation parameters wherein the mass velocity in the Reynolds number was replaced by the product of air density evaluated at the average film temperature and the so-called friction velocity; in addition, the physical properties of air were evaluated at the average film temperature. The isothermal friction data for the rough tubes, when plotted in the conventional manner, resulted in curves similar to those obtained by other investigators; that is, the curve for a given roughness breaks away from the Blasius line (representing turbulent flow in smooth tubes) at some value of Reynolds number, which decreases with increase in surface roughness, and then becomes a horizontal line (friction coefficient independent of Reynolds number). A comparison of the friction data for the rough tubes used herein indicated that the conventional roughness ratio is not an adequate measure of relative roughness for tubes having a square-thread-type element. The present data, as well as those of other investigators, were used to isolate the influence of ratios of thread height to width, thread spacing to width, and the conventional roughness ratio on the friction coefficient. A fair correlation of the friction data was obtained for each tube with heat addition when the friction coefficient and Reynolds number were defined on the basis of film properties; however, the data for each tube retained the curve characteristic of that particular roughness. The friction data for all the rough tubes could be represented by a single line for the complete turbulence region by incorporating a roughness parameter in the film correlation. No correlation was obtained for the region of incomplete turbulence.

Sams, E. W.↗

The utility of surface temperature measurements for the remote sensing of surface soil water status

Experiments carried out on an Avondale loam soil indicated that the thermal inertia concept of soil water content detection is reasonably sound. The volumetric water contents of surface soil layers between 2 and 4 cm thick were found to be linear functions of the amplitude of the diurnal surface soil temperature wave for clear day-night periods. They were also found to be linear functions of the daily maximum value of the surface soil-air-temperature differential. Tests on three additional soils ranging from sandy loam to clay indicated that the relations determined for Avondale loam could not be accurately applied to these other soil types. When the moisture characteristic curves of each soil were used to transform water contents into pressure potentials, however, it was found that soil water pressure potential could be determined without prior knowledge of soil type, and thus its value as a potential soil water status survey tool was significantly enhanced.

Idso, S. B.↗

Film calibration for the Skylab/ATM S-056 X-ray telescope

The sensitometry and film calibration effort for the Skylab/ATM S-056 X-ray telescope is summarized. The apparatus and procedures used are described together with the two types of flight film used, Kodak SO-212 and SO-242. The sensitometry and processing of the flight film are discussed, and the results are presented in the form of the characteristic curves and related data. The use of copy films is also discussed.

Henze, W., Jr.↗

Radiance calibration of the High Altitude Observatory white-light coronagraph on Skylab

The processing of over 35,000 photographs of the solar corona obtained by the white-light coronograph on Skylab is described. Calibration of the vast amount of data was complicated by temporal effects of radiation fog and latent image loss. These effects were compensated by imaging a calibration step wedge on each data frame. Absolute calibration of the wedge was accomplished through comparison with a set of previously calibrated glass opal filters. Analysis employed average characteristic curves derived from measurements of step wedges from many frames within a given camera half-load. The net absolute accuracy of a given radiance measurement is estimated to be 20%.

Poland, A. I.↗

Comparative performance of silicon and gallium arsenide solar cells on a high altitude sounding rocket

The use of sounding rockets for calibrating solar cells offers two principal advantages: (1) there is no effect due to the terrestrial atmosphere, and (2) the cells are recoverable immediately after the calibration. On March 30, 1976, 29 n/p silicon and four p/n gallium arsenide solar cells were calibrated in space and successfully recovered from a NASA-Astrobee F rocket that reached a peak altitude of 230 km. Approximately 75 IV characteristic curves were generated for 32 of the cells to an accuracy of plus or minus 0.2 ma and plus or minus 0.2 mV.

Thomas, N. L.↗

Precise matching of diodes

Two circuit arrangements using ac and dc power source provide low-cost method for matching forward voltage drops of diodes and other semiconductors. Both circuits are simpler and less expensive than conventional, characteristic-curve tracers.

Mclyman, W. T.↗