Search NASA⌕ Search

SEARCH · Search NASA

Results for “characterization techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Study to perform preliminary experiments to evaluate particle generation and characterization techniques for zero-gravity cloud physics experiments

Methods of particle generation and characterization with regard to their applicability for experiments requiring cloud condensation nuclei (CCN) of specified properties were investigated. Since aerosol characterization is a prerequisite to assessing performance of particle generation equipment, techniques for characterizing aerosol were evaluated. Aerosol generation is discussed, and atomizer and photolytic generators including preparation of hydrosols (used with atomizers) and the evaluation of a flight version of an atomizer are studied.

Katz, U.↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

BiasMDP: Carrier lifetime characterization technique with applied bias voltage

A characterization method is presented, which determines fixed charge and interface defect densities in passivation layers. This method bases on a bias voltage applied to an electrode on top of the passivation layer. During a voltage sweep, the effective carrier lifetime is measured by means of microwave detected photoconductivity. When the external voltage compensates the electric field of the fixed charges, the lifetime drops to a minimum value. This minimum value correlates to the flat band voltage determined in reference impedance measurements. This correlation is measured on p-type silicon passivated by Al{sub 2}O{sub 3} and Al{sub 2}O{sub 3}/HfO{sub 2} stacks with different fixed charge densities and layer thicknesses. Negative fixed charges with densities of 3.8 × 10{sup 12 }cm{sup −2} and 0.7 × 10{sup 12 }cm{sup −2} are determined for Al{sub 2}O{sub 3} layers without and with an ultra-thin HfO{sub 2} interface, respectively. The voltage and illumination dependencies of the effective carrier lifetime are simulated with Shockley Read Hall surface recombination at continuous defects with parabolic capture cross section distributions for electrons and holes. The best match with the measured data is achieved with a very low interface defect density of 1 × 10{sup 10 }eV{sup −1} cm{sup −2} for the Al{sub 2}O{sub 3} sample with HfO{sub 2} interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring battery material failure mechanisms through synchrotron X-ray characterization techniques

Rechargeable battery cycling performance and related safety have been persistent concerns. Here, it is crucial to decipher the capacity fading induced by electrode material failure via a range of techniques. Among these, synchrotron-based X-ray techniques with high flux and brightness play a key role in understanding degradation mechanisms. In this comprehensive review, we summarized recent advancements in degradation modes and mechanisms that revealed by synchrotron X-ray methodologies. Subsequently, an overview of X-ray absorption spectroscopy and X-ray scattering techniques are introduced for the characterizing failure phenomena at local coordination atomic environment and long-range order crystal structure scale, respectively. At last, we envision the future of material failure mechanism exploration.

25 ENERGY STORAGE↗

Overview of Characterization Techniques for High Speed Crystal Growth

Features of characterization requirements for crystals, devices and completed products are discussed. Key parameters of interest in semiconductor processing are presented. Characterization as it applies to process control, diagnostics and research needs is discussed with appropriate examples.

Ravi, K. V.↗

Characterization of electrically-active defects in ultraviolet light-emitting diodes with laser-based failure analysis techniques

Laser-based failure analysis techniques demonstrate the ability to quickly and non-intrusively screen deep ultraviolet light-emitting diodes (LEDs) for electrically-active defects. In particular, two laser-based techniques, light-induced voltage alteration and thermally-induced voltage alteration, generate applied voltage maps (AVMs) that provide information on electrically-active defect behavior including turn-on bias, density, and spatial location. Here, multiple commercial LEDs were examined and found to have dark defect signals in the AVM indicating a site of reduced resistance or leakage through the diode. The existence of the dark defect signals in the AVM correlates strongly with an increased forward-bias leakage current. This increased leakage is not present in devices without AVM signals. Transmission electron microscopy analysis of a dark defect signal site revealed a dislocation cluster through the pn junction. The cluster included an open core dislocation. Even though LEDs with few dark AVM defect signals did not correlate strongly with power loss, direct association between increased open core dislocation densities and reduced LED device performance has been presented elsewhere [M. W. Moseley et al., J. Appl. Phys. 117, 095301 (2015)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation and validation of an ultrasonic tissue characterization technique for quantitative assessment of normal-tissue toxicity in radiation therapy

The goal of this study was to implement and validate a noninvasive, quantitative ultrasonic technique for accurate and reproducible measurement of normal-tissue toxicity in radiation therapy. The authors adapted an existing ultrasonic tissue characterization (UTC) technique that used a calibrated 1D spectrum based on region-of-interest analysis. They modified the calibration procedure by using a reference phantom instead of a planar reflector. This UTC method utilized ultrasonic radio-frequency echo signals to generate spectral parameters related to the physical properties (e.g., size, shape, and relative acoustic impedance) of tissue microstructures. Three spectral parameters were investigated for quantification of normal-tissue injury: Spectral slope, intercept, and midband fit. They conducted a tissue-mimicking phantom study to verify the reproducibility of UTC measurements and initiated a clinical study of radiation-induced breast-tissue toxicity. Spectral parameter values from measurements on two phantoms were reproducible within 1% of each other. Eleven postradiation breast-cancer patients were studied and significant differences between the irradiated and untreated (contralateral) breasts were observed for spectral intercept (p=0.003) and midband fit (p<0.001) but not for slope (p=0.14). In comparison to the untreated breast, the average difference in the spectral intercept was 2.99{+-}0.75 dB and the average difference in the midband fit was 3.99{+-}0.65 dB. The preliminary clinical study demonstrated the feasibility of using the quantitative ultrasonic method to evaluate normal-tissue toxicity in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-technique Characterization of Adsorbed Peptide and Protein Orientation: LK310 and Protein G B1

The ability to orient biologically active proteins on surfaces is a major challenge in the design, construction, and successful deployment of many medical technologies. As methods to orient biomolecules are developed, it is also essential to develop techniques that can accurately determine the orientation and structure of these materials. In this study, two model protein and peptide systems are presented to highlight the strengths of three surface analysis techniques for characterizing protein films: time-of-flight secondary-ion mass spectrometry (ToF-SIMS), sum-frequency generation (SFG) vibrational spectroscopy, and near-edge x-ray absorption fine structure (NEXAFS) spectroscopy. First, the orientation of Protein G B1, a rigid 6 kDa domain covalently attached to a maleimide-functionalized self-assembled monolayer, was examined using ToF-SIMS. Although the thickness of the Protein G layer was similar to the ToF-SIMS sampling depth, orientation of Protein G was successfully determined by analyzing the C{sub 2}H{sub 5}S{sup +} intensity, a secondary-ion derived from a methionine residue located at one end of the protein. Next, the secondary structure of a 13-mer leucine-lysine peptide (LK{sub 310}) adsorbed onto hydrophilic quartz and hydrophobic fluorocarbon surfaces was examined. SFG spectra indicated that the peptide's lysine side chains were ordered on the quartz surface, while the peptide's leucine side chains were ordered on the fluorocarbon surface. NEXAFS results provided complementary information about the structure of the LK{sub 310} film and the orientations of amide bonds within the LK{sub 310} peptide.

59 BASIC BIOLOGICAL SCIENCES↗

Development of non-invasive acoustic characterization techniques for the oil and gas industry [Slides]

The production of crude oil and other liquid fuels in the US has been steadily rising since 2007 and according the International Energy Agency, the US will be entirely self-sufficient by 2030. This forecast is based on advancing new extraction methods and also developing smaller and more marginal reservoirs in a cost effective way. This requires highly efficient monitoring technology that can provide an accurate and realtime estimate of oil production from each and every well. The technologies currently used in oil-fields are either decades old, not very accurate, expensive to maintain and operate, and often incapable of delivering real-time information. Therefore, the oil and gas industry is looking for technology that can monitor multiphase (oil/water/gas) production fluids to address all these challenges and ensure energy security for the future. In this talk, I will discuss the development of an ultrasound-based noninvasive technique for the simultaneous and real-time measurement of both the composition (“water-cut”) and flow rate of crude oil and process water as these are pumped out from the ground. This technique relies on the accurate ultrasound propagation characterization of a flowing multiphase fluid through a thick-walled pipe. Time-dependent ultrasound transmission and its spatial coherence were used to determine several important physical parameters of the fluid mixture, such as sound speed, sound attenuation, and flow velocity. Different algorithms were developed to derive appropriate composition values from this data. The composition algorithm originates from the fundamental behavior of sound propagation in composite materials. A remotely-controllable portable instrument was built and tested extensively on location at various oil fields in the US. The technology developed has been licensed to industry and the final product is currently being manufactured. Upon deployment, the instrument is expected to positively impact reservoir management schemes and be applicable to various process control industries. I will conclude with brief descriptions of additional ultrasonic techniques currently being developed by the Acoustics and Sensors Team to address future challenges in the oil industry.

02 PETROLEUM↗

Advanced Characterization Techniques for Sodium-Ion Battery Studies

Sodium (Na)-ion batteries (NIBs) are considered promising alternative candidates to the well-commercialized lithium-ion batteries, especially for applications in large-scale energy storage systems. The electrochemical performance of NIBs such as the cyclability, rate capability, and voltage profiles are strongly dependent on the structural and morphological evolution, phase transformation, sodium-ion diffusion, and electrode/electrolyte interface reconstruction during charge–discharge cycling. Therefore, in-depth understanding of the structure and kinetics of electrode materials and the electrode/electrolyte interfaces is essential for optimizing current NIB systems and exploring new materials for NIBs. Recently, rapid progress and development in spectroscopic, microscopic, and scattering techniques have provided extensive insight into the nature of structural evolution, morphological changes of electrode materials, and electrode/electrolyte interface in NIBs. Here in this review, a comprehensive overview of both static (ex situ) and real-time (in situ or in operando) techniques for studying the NIBs is provided. Lastly, special focus is placed on how these techniques are applied to the fundamental investigation of NIB systems and what important results are obtained.

25 ENERGY STORAGE↗

Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610

Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Marine Algae Polysaccharides: An Overview of Characterization Techniques for Structural and Molecular Elucidation

Polysaccharides make up a large portion of the organic material from and in marine organisms. However, their structural characterization is often overlooked due to their complexity. With many high-value applications and unique bioactivities resulting from the polysaccharides’ complex and heterogeneous structures, dedicated analytical efforts become important to achieve structural elucidation. Because algae represent the largest marine resource of polysaccharides, the majority of the discussion is focused on well-known algae-based hydrocolloid polymers. The native environment of marine polysaccharides presents challenges to many conventional analytical techniques necessitating novel methodologies. We aim to deliver a review of the current state of the art in polysaccharide characterization, focused on capabilities as well as limitations in the context of marine environments. This review covers the extraction and isolation of marine polysaccharides, in addition to characterizations from monosaccharides to secondary and tertiary structures, highlighting a suite of analytical techniques.

09 BIOMASS FUELS↗

A review of chromatographic characterization techniques for biodiesel and biodiesel blends.

This review surveys chromatographic technology that has been applied to the characterization of biodiesel and its blends. Typically, biodiesel consists of fatty acid methyl esters produced by transesterification of plant or animal derived triacylglycerols. Primary attention is given to the determination of trace impurities in biodiesel, such as methanol, glycerol, mono-, di-, and triacylglycerols, and sterol glucosides. The determination of the fatty acid methyl esters, trace impurities in biodiesel, and the determination of the biodiesel content of commercial blends of biodiesel in conventional diesel are also addressed.

10 SYNTHETIC FUELS↗

Standard Characterization Techniques for Inorganic Phase Change Materials

Salt hydrates are promising candidates for phase change materials (PCMs) because of their low cost and high energy storage capacity. However, practical applications of salt hydrate based PCMs are limited due to their poor thermal cycling performance caused by phase separation and supercooling. Various techniques, including differential scanning calorimetry (DSC) and transient plane source (TPS) have been used to characterize salt hydrate based PCMs but may not provide full understanding of the degradation mechanism. In this manuscript, salt hydrate and graphite composites are prepared. Temperature history (T-History) method and X-ray diffraction (XRD) are utilized for measuring melting temperature, energy storage, and latent heat degradation of the PCM composites. Highlighting the importance of each technique and how each technique plays an important role in analyzing salt hydrates performance accurately. Temperature history, and X-ray diffraction are also used in conjunction to precisely predict the cause of degradation in salt hydrate PCMs with thermal cycling, as in most literatures the cause of degradation in salt hydrate are attributed to phase segregation, supercooling, and change in stichometry water concentration without any scientific validation.

Kumar, Navin↗

Advanced Characterization Techniques for Overcoming Challenges of Perovskite Solar Cell Materials

Abstract In the last 10 years, organic–inorganic hybrid perovskite solar cells have achieved unprecedented advances, to the point where they now exhibit extremely high efficiency. However, long‐term stability and areal scalability limitations impede the commercial application of perovskite materials, and appropriate diagnosistic tools have become necessary to evaluate perovskite materials. Characterization of perovskite materials is regularly misinterpretated, due to unique intrinsic and extrinsic factors: degradation from the measurement source, ion migration, phase transition, and separation. Herein, studies on perovskites are reviewed that have used advanced characterization tools to overcome characterization challenges. Cryogenic temperature assisted measurements mitigate degradation or phase transitions induced by the measurement source. In situ measurements can track the variation of perovskite materials depending on external stimuli. Spatial material properties are able to be evaluated by the use of multidimensional mapping techniques. An overview of these advanced characterization tools that can overcome the challenges associated with established tools provides the opportunity for further understanding perovskite materials and solving the remaining challenges on the road to commercialization.

Kim, Min‐cheol↗

Expanded Use of ISOCS Characterization Techniques for WIPP Certification at the Idaho Clean-up Project - 19623

The Advanced Mixed Waste Treatment Project (AMWTP) has been retrieving, treating, characterizing, and shipping legacy Transuranic (TRU) waste for disposal since 2003 as part of the overall Idaho Cleanup Project (ICP) in support of the US Department of Energy. As the ICP has progressed, over 700 containers have been identified that cannot be successfully assayed using the current suite of non-destructive assay (NDA) instruments. To meet this challenge, Fluor Idaho, LLC, and Mirion Technologies (formerly Canberra Industries) have teamed to deploy the In-Situ Object Counting System (ISOCS) to supplement the current NDA capabilities. ISOCS has long been used in various radioactive waste management applications, but never has the ISOCS ability to perform intrinsic efficiency modeling of discrete waste containers been employed to characterize and certify TRU waste for disposal at the Waste Isolation Pilot Plant (WIPP), near Carlsbad, New Mexico. Since the primary disposal facility for this waste is the WIPP, the characterization processes for determining the quantity of radioactive material entrained in the waste are subject to WIPP Waste Acceptance Criteria (WAC) quality requirements and associated performance criteria. Until now, the Carlsbad Field Office (CBFO) WIPP-certified NDA equipment has utilized pre-defined efficiency calibrations for fixed geometries. However, due to the radioactive material content, activity levels, waste stream matrix, and/or the geometries of various size drums, boxes and other-odd-shaped containers or container integrity issues, it may not be suitable to characterize these containers with any of the existing WIPP-certified NDA equipment located at the AMWTP. Therefore, advanced technologies are needed to complete characterization of these problematic waste containers. The July 5, 2016 release of the WIPP WAC, DOE/WIPP-02-3122, Revision 8.0, Appendix A, 'Radioassay Requirements for Transuranic Waste,' was expanded to include several newer concepts such as American Society for Testing and Materials (ASTM) approved methods for efficiency-based calibrations and the use of mathematical computer modeling techniques for calibration. This change prompted AMWTP to pursue obtaining WIPP certification authority for expanded ISOCS techniques to deal with the remaining challenging waste containers and the development and implementation of Mirion's Figures of Merit (FOM) evaluations. These vital FOM evaluations enhance the ISOCS's modeling capabilities by optimizing the dynamic efficiency calibration for each object and reducing the assay's Total Measurement Uncertainty (TMU) budget. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗