Search NASA⌕ Search

SEARCH · Search NASA

Results for “charged particle scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Self-compensating light calorimetry with liquid argon time projection chamber for GeV neutrino physics

The Liquid Argon Time Projection Chamber (LArTPC) is a powerful dual calorimeter capable of estimating particle energy from both ionization charge and scintillation light. Here, our study shows that, due to the recombination luminescence, the LArTPC functions as a self-compensating light calorimeter: the missing energy in the hadronic component is compensated for by the increased luminescence relative to the electromagnetic component. Using 0.5-5 GeV electron neutrino charged current interactions as a case study, we show that good compensation of the electron-to-hadron response ratio (e/h) from 1-1.05 can be achieved across a broad range of drift electric fields (0.2-1.8 kV / cm), with better performance for neutrino energies above 2 GeV. This study highlights the potential of light calorimetry in LArTPCs for GeV neutrino energy reconstruction, complementing traditional charge calorimetry. Under ideal conditions of uniform light collection, we show that LArTPC light calorimetry can achieve an energy resolution comparable to the charge imaging calorimetry. Challenges arising from nonuniform light collection in large LArTPCs can be mitigated with a position-dependent light yield correction derived from 3D charge signal imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EGRET - The high energy gamma ray telescope for NASA's Gamma Ray Observatory

The EGRET high energy gamma-ray telescope under development for NASA's Gamma Ray Observatory will have an energy range of approximately 12 to 30,000 MeV, energy resolution of about 15 percent FWHM over most of that range, an effective area of about 2000 sq cm at high energies, and single photon angular accuracy of approximately 2 deg at 100 MeV, less than 0.1 deg above 5 GeV. This instrument can locate strong sources to an accuracy of about 5 arc min. The instrument utilizes a set of digital spark chambers interleaved with tantalum foils for detection and identification of gamma-ray events, and a large NaI(Tl) scintillator for energy determination. The system is triggered by a coincidence matrix using two arrays of plastic scintillation counters and a large plastic scintillator anticoincidence dome that rejects incident charged particles.

Fichtel, C. E.↗

Neutrino beam bunch structure reconstruction with precision timing in the ICARUS liquid argon time projection chamber

The ICARUS detector has been operating smoothly since 2021 as the far detector in the Short Baseline Neutrino (SBN) program at Fermilab, collecting neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Neutrinos at the Main Injector (NuMI) beam. Analysis of neutrino interactions in ICARUS requires mitigation of substantial cosmogenic backgrounds. This is achieved by using an external Cosmic Ray Tagger (CRT) and a Photomultiplier Tube (PMT) system embedded in the liquid argon. The intrinsic neutrino beam bunch structure, inherited time structure from the Radio Frequency (RF) system used to accelerate the protons, can be resolved at the ICARUS detector using precise timing information. Located at shallow depth, ICARUS is exposed to a high flux of cosmic rays that can be mistaken for neutrino interactions. To mitigate this background, the CRT and a 3-meter-thick concrete overburden were installed. To better model backgrounds, ICARUS makes use of an overlay technique where simulated neutrino events are superimposed on detector beam-off data. PMTs installed within a Time Projection Chamber detect argon scintillation light emitted by high energy charged particles passing through the chamber and provide the event timing of neutrino interactions. The nanosecond-level beam bunch structure is reconstructed with the PMT system and can be used to further understand backgrounds and enhance neutrino physics capabilities. In this thesis, I will discuss background mitigation techniques using precision timing and present a novel technique to select neutrino events from our unbiased data stream using the beam bunch structure.

Heggestuen, Anna [Colorado State U.] (ORCID:000000↗

Neutrino Hunting: Looking through a UV Lens Scintillation Photon Detection in a Large-Volume Liquid Argon Time Projection Chamber, Exposed to a Multi-GeV Charged Particle Beam

The Deep Underground Neutrino Experiment (DUNE) will be a world-class neutrino observatory and nucleon decay detector designed to answer fundamental questions about elementary particles and their role in the universe. The DUNE experiment will consist of a a Near Detector, located at Fermilab, and a Far Detector, approximately 1.5~km underground at the Sanford Underground Research Facility in South Dakota, located $\sim$1300~km away. The accelerator complex at Fermilab will host an intense beam of neutrinos directed toward the two detectors. My dissertation centers on the implementation of technologies used to detect scintillation photon signals in liquid argon in the context of the DUNE's Far Detector Single-Phase (SP) module design, and features direct contributions to the Photon Detection System (PDS) deployed in the ProtoDUNE-SP Large-Volume Liquid Argon Time Projection Chamber (LArTPC) prototype. The PDS is needed for non-beam event timing, such as atmospheric neutrinos, proton d ecay, and supernova detection. The PDS provides a prompt signal ($t_{0}$ information) for micro-second event time determination, which improves the TPC's spatial localization along drift direction, enables accurate ionization-signal-attenuation determination, and even provides calorimetry. My dissertation will discuss an overview of the DUNE and ProtoDUNE-SP experiment and how we detect neutrinos in LAr, via charge and scintillation light. It will discuss my core experimental and analysis work, in regards to the Photon Detection System; including my contributions in establishing procedures for the commissioning and integration for the Photon Detector System that will be valuable during the construction, installation, commissioning, and operations of the DUNE Far Detector. In addition, it will comprehensively discuss the capability of three different photon detection technologies, and their characteristics and responses to muon and electron beam particles over a range of beam momenta , from 0.3~GeV/$c$ - 7~GeV/$c$. Further, the overall progress detailed in this thesis will help pave the way toward understanding the physical properties of these detectors, which will contribute to the success of the sensitivity measurements required for determining the neutrino mass hierarchy and $\delta_{CP}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Jupiter's trapped radiation by pioneer

The experiments planned for Pioneers F and G during their Jupiter flybys are discussed. The complement includes four energetic charged particle experiments: University of Iowa package consisting of Geiger-Mueller tubes; University of California, San Diego, trapped radiation package consisting of solid state detectors, thin scintillators, and an alcohol water Cerenkov radiator; University of Chicago package containing charged particle detectors; and a Goddard Space Flight Center package containing solid state, cosmic ray detectors. Other experiments are the Jet Propulsion Laboratory magnetometer and the Ames Research Center plasma analyzer. Pitch angle distributions at Jupiter, and the capabilities for unambiguous identification of energetic protons at Jupiter are also discussed.

Mihalov, J. D.↗

A potential probe of Fundamental Interactions using Multi-Modal Cosmic Ray events

The Horizon-T experiment in Tien Shan is based on the idea of measuring the time at which EAS disc passes the observation level with nanosecond accuracy. The detector system consists of ten charged particles registration points located at distances of up to several hundred meters from each other. The points are equipped with detectors based on registration of Cherenkov radiation in glass and registration of scintillation light in polystyrene. The detectors register the arrival times of charged particles at the observation level with a resolution of ~2 ns, as required to study the spatial and temporal characteristics of the EAS and the structure of the multi-modal events specifically. Over the period of the Horizon-T data taking since 2017 to present, a large number of multi-modal events were detected. The data has presented numerous challenges that show the direction towards the further development of the detector system and of the analysis methods and techniques that could be applied to these multi-modal events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of $\text{BDX-MINI}$ veto systems

Here this paper describes the veto system of the BDX-MINI detector installed at Jefferson Lab (US). The BDX-MINI experiment is the first electron beam-dump experiment specifically designed to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. The core of the BDX-MINI detector is a lead-tungstate electromagnetic calorimeter, for a total volume of 4 dm 3 . The calorimeter is surrounded by a multi-layer veto aimed at rejecting cosmic background: the innermost layer of the veto is made by a passive tungsten shielding for low energy radiation, while plastic scintillators make the middle and outer layers for charged cosmic particles rejection. Being located about 20 m downstream, the dirt between the beam dump and the detector provides sufficient shielding from the beam-related background. In 2019–2020, BDX-MINI was exposed for about six months to weakly interacting particles (neutrinos and, if existing, DM) produced by a 2.176 GeV electron beam incident on the beam dump of experimental Hall-A at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques in balloon X-ray astronomy.

Since the first balloon observation of the Crab Nebula balloon data have provided much information on the positions, spectra, time variability and pulsed nature of localized sources, and on the spectrum and isotropy of diffuse galactic and universal components. Measurements are limited to energies above about 20 keV by atmospheric attenuation at 2 to 3 g/sq cm depth and to below several hundred keV by detector sensitivity. Detectors usually consist of large-area Na I or Cs I scintillation counters with anticoincidence collimators for rejection of charged particles and scattered X-rays. Proportional counters are occasionally used at lower energies and solid-state detectors are used where extreme energy resolution is important. The instruments require a pointing capability on the order of 1.0 to 0.1 deg, depending on the collimator aperture. Digital data is either recorded on board or telemetered using a PCM technique.

Peterson, L. E.↗

Further analysis of a recent cosmic-ray antiproton experiment

Reference is made to the measurements of a cosmic ray antiproton flux at a few hundred MeV reported by Buffington et al. (1981), noting that one of the final background processes to be removed by the data analysis in that study was helium-induced events which satisfied the criteria for topology and timing. The response in the third scintillator S3 was used to identify and remove these events. For the top two scintillators S1 and S2, pulse size information was lost during the data-taking. A method is reported here for the partial retrieval of pulse size information for the scintillator S2. This is possible because a portion of this signal was subtracted from the Cerenkov response before trigger discrimination and data recording to remove scintillation from the Cerenkov response. For separating protons from more highly charged particles, the method is considered sufficient. It is pointed out that the sample of events identified as antiprotons, for which the method can be applied, has the expected unit charge in scintillator S2.

Buffington, A.↗

Determination of particle-dependent light response for defining detector response functions

This study comprehensively characterizes two scintillation detectors, an organic deuterated liquid and a stilbene crystal, concerning their response to charged particles such as electrons, protons, alphas, and carbon nuclei. The Birks function was used to determine the detectors’ response to charged particles, enabling the determination of particle-dependent light responses. The particle-dependent light characterization was used to determine detector response functions (DRF) using Geant in combination with Gamma Detector Response and Analysis Software (GADRAS). These DRFs enhance GADRAS by enabling full spectral analysis functionality for previously underrepresented detector materials. Additionally, neutron-specific DRFs are determined for neutron energy spectrum unfolding applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

Hink, P. L.↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗