Search NASA⌕ Search

SEARCH · Search NASA

Results for “charging load profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Underlying Data for the EVI-RoadTrip Web Tool

The dataset contains simulation-based charging infrastructure outputs that are visualized on the EVI-RoadTrip webtool. The outputs are aggregated to lower spatial resolution (e.g., state-level, corridor-level).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Dataset of EV Charging Stations With Estimates of Load and Vehicle Throughput

Current data from the AFDC provide locations and many details about EV charging stations, but not estimates of their peak loads or the number of vehicles they can accommodate. This dataset will augment the AFDC charging station locations with estimates of transmission load and vehicle throughput based on engineering specifications of the chargers, charging patterns based on vehicle types, battery capacities, and user behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charger Requirements for GSE at Each Airport

This dataset contains the required number of chargers for GSE at each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

National parks in the Western United States draw over 80 million visitors every year, and most visitors rely on personal cars for their road trips (or long-distance travels). Travel to national parks represents distinct travel demand, as they are typically located in remote areas necessitating long-distance trips. This study investigates the quantity and locations of on-route fast charging infrastructure needed by 2030 to enable seamless travel to/from national parks using electric vehicles in seven target states in the region, employing unprecedented high-resolution spatial and temporal analysis. We find that the required number of fast charging ports for on-route charging infrastructure ranges from 1,200 to 22,000, depending on different assumptions of key input parameters - vehicle electrification rate, charging behavior, average gap between charging stations, port utilization rate, and towing trailers. Our analysis also indicates that electrical load for on-route fast charging infrastructure would peak in the afternoon, in the range of 70-400 MW, varying with the key input parameters. This study illustrates how different input parameters result in different degrees of impact on various aspects of charging infrastructure. We also examine the characteristics of projected charging infrastructure in terms of land use type, relationship with traffic volume, size of stations, and other variables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Weather Sensitive High Spatio-Temporal Resolution Transportation Electric Load Profiles For Multiple Decarbonization Pathways

Electrification of transport compounded with climate change will transform hourly load profiles and their response to weather. We present a novel approach to generating hourly electric load profiles that considers charging strategies and evolving sensitivity to temperature. The approach consists of downscaling annual state-scale sectoral load projections from the multisectoral Global Change Analysis Model (GCAM) into hourly electric load profiles leveraging high resolution climate and population datasets. Profiles are developed and evaluated at the Balancing Authority scale, with a 5-year increment until 2050 over the Western U.S. Interconnect for multiple decarbonization pathways and climate scenarios. The datasets are readily available for production cost model analysis. Our open source approach is transferable to other regions.

Decarbonization, tranportation, Electric vehicle c↗

Integrating Electric Vehicle Charging Infrastructure into Commercial Buildings and Mixed-Use Communities: Design, Modeling, and Control Optimization Opportunities: Preprint

This paper discusses modeling and field studies of controlled EV charging that have been performed with the goal of minimizing requirements for infrastructure upgrades, minimizing building peak demand charges, and maximizing the use of on-site generation. We present a large-scale workplace charging pilot of a demand-controlled scheduled EV charging system with over 250 active daily commuters, successfully demonstrating management of aggregate charging power to avoid new infrastructure investments, mitigate peak demand charges, and provide cost-effective workplace charging to users. In addition to understanding opportunities for demand management, integrating these controllable loads into the energy modeling process for new buildings will also be necessary. This paper then presents an example energy modeling process that evaluates the potential effects of EV charging on building load profiles and infrastructure requirements for a mixed-use community. Finally, we discuss an illustration of how EV charging can be controlled to be synergistic with other building loads and distributed generation.

buildings↗

Large-scale scenarios of electric vehicle charging with a data-driven model of control

Transportation electrification is forecast to bring millions of new electric vehicles to roads worldwide this decade. Planning to support those vehicles depends on detailed scenarios of their electricity demand in both uncontrolled and controlled or smart charging scenarios. In this work, we present a novel modeling approach to enable rapid generation of demand estimates that represent the impact of controlled charging for large-scale scenarios with millions of individual drivers. To model the effect of load modulation control on aggregate charging profiles, we propose a novel machine learning approach that replaces traditional optimization approaches. We demonstrate its performance modeling workplace charging control under a range of electricity rate schedules, achieving small errors (2.5%–4.5%) while accelerating computations by more than 4000 times. To generate the uncontrolled charging demand for scenarios with residential, workplace, and public charging we use statistical representations of a large data set of real charging sessions. We demonstrate the methodology by generating diverse sets of scenarios for California's charging demand in 2030 which consider multiple charging segments and controls, each run locally in under 50 s. We further demonstrate support for rate design by modeling the large-scale impact of a new, custom rate schedule for workplace charging.

33 ADVANCED PROPULSION SYSTEMS↗

Forecasting Solar-Thermal Systems Performance under Transient Operation Using a Data-Driven Machine Learning Approach Based on the Deep Operator Network Architecture

Modeling and prediction of the dynamic behavior of thermal systems operating under intermittent energy input and variable load requirements represent one of the greatest challenges in the development of efficient and reliable renewable-based power generation technologies. In this work, a data-driven machine learning modeling framework was developed based on a modified version of the Deep Operator Network architecture where the time coordinate in the trunk net is replaced with historical data of the predicting quantity. The modeling framework can be used to accurately predict the performance of renewable-based energy conversion technologies including wind- and solar-based power plants. This novel framework was applied on a solar-thermal system that consists of a solar collection loop using a flat plate collector, a power generation loop comprising an Organic Rankine Cycle, and a thermal energy storage tank connecting both loops. Variable solar irradiance, air temperature, and power load profiles were used by the Deep Operator Network to predict the State-of-Charge and the efficiency of the thermal system for several days. The results were compared with the State-of-Charge and efficiency functions calculated using a physics-based model. For a simple operation scenario, characterized by a clear sky solar irradiance profile and constant load, the standard deviation in the State-of-Charge prediction by Deep Operator Network is below 0.9% during a seven-day prediction time horizon. For the most realistic operation scenario that considers real solar irradiance and a rough load profile, the maximum standard deviation in the predictions for the State-of-Charge and efficiency are below 6.8% and 2.5%, respectively. A comparison between Deep Operator Network and Long Short Term Memory network was also performed. In general, both networks predict very well the State-of-Charge for different data density conditions; however, a higher accuracy, with a standard deviation below 2.0%, is obtained by the Deep Operator Network during three and half days using sparser training data of 20-minute points. The same accuracy for the State-of-Charge prediction with the Long Short Term Memory network is achieved only for 14 h. Average standard deviations for the State-of-Charge prediction of 1.1% with the Deep Operator Network and 1.5% with the Long Short Term Memory network are obtained for a four-day prediction time using a denser training data of 5-minute points.

DeepONet↗

GridPIQ Reference Data

GridPIQ uses dozens of publicly available datasets to provide context for a user's grid project, as well as defaults for users to choose from. Users can choose to import their own data to better customize their analysis or use GridPIQ-supplied defaults. This allows users to get up and running with an analysis very quickly without having to spend significant time pulling together input data. To run an electric vehicle (EV) smart charging project, a user will need to provide or select from prepopulated values for the regional load profile shape and peak load, region of interest and closest weather station, EV charging profile, number of EVs to add for the analysis, maximum EV charging power, location of chargers relative to grid infrastructure, and allowable charging times (for coordinated charging mode). The outputs of the analysis are changes in air quality, EV energy consumption, EV peak demand, and EV hourly consumption profile—before and after project implementation." For a detailed description of the tool methodology, including all the publicly available datasets used by the tool, see the [GridPIQ documentation](https://gridpiq.pnnl.gov/v2-beta/doc/).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-driven method for electric vehicle charging demand analysis: Case study in Virginia

Electric vehicle (EV) adoption in the U.S. will be accelerated by the historic $7.5 billion public investments in EV charging infrastructure. Careful analysis of EV charging demands plays a vital role in understanding the energy requirements, power grid impact, and smart charging management opportunities of EVs. To this end, this paper develops a data-driven trip-chaining-based modeling framework including five steps: Trip data acquisition and preprocessing, EV adoption modeling, travel itinerary synthesis, EV charging demand simulation and EV load profile generation. The developed analysis framework was demonstrated using real-world data for one region in Virginia, U.S. The results show that the proposed modeling framework can work effectively. For the study region in 2040, the predicted number of plug-in EVs is 470,114, resulting in a weekly charging demand of 38,078,127 kWh (55% home, 9% work, and 36% public) in September and 45,920,358 kWh (61% home, 9% work, and 30% public) in February.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗