Search NASA⌕ Search

SEARCH · Search NASA

Results for “charging stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Upwelling Radiance at 976 nm Measured from Space Using a CCD Camera

The Optical Payload for Lasercomm Science (OPALS) Flight System on-board the International Space Station uses a charge coupled device (CCD) camera for receiving a beacon laser from Earth. Relative measurements of the background contributed by upwelling radiance under diverse illumination conditions and varying terrain is presented. In some cases clouds in the field-of-view allowed a comparison of terrestrial and cloud-top upwelling radiance. In this paper we will report these measurements and examine the extent of agreement with atmospheric model predictions.

Biswas, Abhijit↗

Hypervelocity Impact Testing of International Space Station Meteoroid/Orbital Debris Shielding Using an Inhibited Shaped Charge Launcher

Engineers at the NASA Johnson Space Center have conducted hypervelocity impact (HVI) performance evaluations of spacecraft meteoroid and orbital debris (M/OD) shields at velocities in excess of 7 km/s. The inhibited shaped charge launcher (ISCL), developed by the Southwest Research Institute, launches hollow, circular, cylindrical jet tips to approximately 11 km/s. Since traditional M/OD shield ballistic limit performance is defined as the diameter of sphere required to just perforate or spall a spacecraft pressure wall, engineers must decide how to compare ISCL derived data with those of the spherical impactor data set. Knowing the mass of the ISCL impactor, an equivalent sphere diameter may be calculated. This approach is conservative since ISCL jet tips are more damaging than equal mass spheres. A total of 12 tests were recently conducted at the Southwest Research Institute (SWRI) on International Space Station M/OD shields. Results of these tests are presented and compared to existing ballistic limit equations. Modification of these equations is suggested based on the results.

Kerr, Justin H.↗

Simulation of the Interaction Between Flywheel Energy Storage and Battery Energy Storage on the International Space Station

Replacement of one module of the battery charge discharge unit (BCDU) of the International Space Station (ISS) by a flywheel energy storage unit (FESU) is under consideration. Integration of these two dissimilar systems is likely to surface difficulties in areas of system stability and fault protection. Other issues that need to be addressed include flywheel charge and discharge profiles and their effect on the ISS power system as well as filter sizing for power Ability purposes. This paper describes a SABER based simulation to study these issues.

Trouong, Long V.↗

Observed Coupling Between the International Space Station PCU Plasma and a FPMU Langmuir Probe Facilitated by the Geomagnetic Field

Electrical charging of the International Space Station (ISS) is a matter of serious concern resulting from the possibility of vehicle arcing and electrical shock hazard to crew during extravehicular activity (EVA). A Plasma Contactor Unit (PCU) was developed and integrated into ISS in order to control the ISS floating potential, thereby, minimize vehicle charging and associated hazards. One of the principle factors affecting ISS electrical charging is the ionosphere plasma state (i.e., electron temperature and density). To support ISS electrical charging studies a Floating Potential Monitoring Unit (FPMU) is also integrated into ISS in order to measure the ionosphere properties using Langmuir probes (LP). The FPMU was located on the Starboard side of ISS. The PCU is located near the center of ISS with its plasma exhaust pointed to port. From its integration on ISS in 2006 through November of 2009, the FPMU data exhibited nominal characteristics during PCU operation. On November 21, 2009 the FPMU was relocated from the Starboard location to a new Port location. After relocation significant enhanced noise was observed in both the LP current-voltage sweeps and the derived electron temperature data. The enhanced noise only occurred when the PCU was in discharge and at unique and repeatable locations of the ISS orbit. The cause of this enhanced noise was investigated. It was found that there is coupling occurring between the PCU plasma and the FPMU LP. In this paper we shall 1) present the on-orbit data and the presence of enhanced noise, 2) demonstrate that the coupling of the PCU plasma and the FPMU measurements is geomagnetically organized, 3) show that coupling of the PCU plasma and the FPMU is primarily due to and driven by particle-wave interaction and 4) show that the ionosphere conditions are adequate for Alfven waves to be generated by the PCU plasma.

Hartman, William↗

Charged body-plasma interaction research laboratory for the International Space Station

An experiment is proposed for the provision of a fundamental plasma physics facility onboard the International Space Station (ISS) for the investigation of the plasma processes governing the electron current collection processes on a charged electrode. The facility will allow the pre-sheath and sheath physics of a positively biased body to be investigated. These processes are important to the consideration of the use of electrodynamic tether lines for practical applications such as for electrical power generation and to the understanding of the physics of space plasma. A deployment mechanism is required to deploy the charged body to a distance of several 100 m from the space station. The possible solutions are a flexible boom or a short tether line.

Lebreton, Jean-Pierre↗

Calibration and Readiness of the ISS-RAD Charged Particle Detector

The International Space Station (ISS) Radiation Assessment Detector (RAD) is an intravehicular energetic particle detector designed to measure a broad spectrum of charged particle and neutron radiation unique to the ISS radiation environment. In this presentation, a summary of calibration and readiness of the RAD Sensor Head (RSH) - also referred to as the Charged Particle Detector (CPD) - for ISS will be presented. Calibration for the RSH consists of p, He, C, O, Si, and Fe ion data collected at the NASA Space Radiation Laboratory (NSRL) and Indiana University Cyclotron Facility (IUCF). The RSH consists of four detectors used in measuring the spectroscopy of charged particles - A, B, C, and D; high-energy neutral particles and charged particles are measured in E; and the last detector - F - is an anti-coincidence detector. A, B, and C are made from Si; D is made from BGO; E and F are made from EJ260XL plastic scintillator.

Rios, R.↗

A Review of Testing of Hollow Cathodes for the International Space Station Plasma Contactor

Since October 2000, two plasma contactors have been providing charge control on the International Space Station (ISS). At the heart of each of the two plasma contactors is a hollow cathode assembly (HCA) that produces the contacting xenon plasma. The HCA is the result of 9 years of design and testing at the NASA Glenn Research Center. This paper summarizes HCA testing that has been performed to date. As of this time, one cathode has demonstrated approximately 28,000 hr of lifetime during constant, high current use. Another cathode, HCA.014. has demonstrated 42,000 ignitions before cathode heater failure. In addition to these cathodes, four cathodes. HCA.006, HCA.003, HCA.010, and HCA.013 have undergone cyclic testing to simulate the variable current demand expected on the ISS. HCA.006 accumulated 8,000 hr of life test operation prior to being voluntarily stopped for analysis before the flight units were fabricated. HCA.010 has accumulated 15,876 hr of life testing, and 4,424 ignitions during ignition testing. HCA.003 and HCA.0 13 have accumulated 12,415 and 18,823 hr of life testing respectively.

Kovaleski, S. D.↗

Comparison of On-Orbit and Ground Based Hollow Cathode Operation

The Plasma Contactor Unit (PCU) was developed by the Rocketdyne division of Boeing to control charging of the International Space Station (ISS). Each PCU contains a Hollow Cathode Assembly (HCA), which emits the charge control electrons. The HCAs were designed and fabricated at NASA's Glenn Research Center (GRC). GRC's HCA development program included manufacture of engineering, qualification, and flight model HCAs as well as wear tests and qualification tests. GRC is currently tracking the on-orbit data for the flight HCAs. This data will be discussed with comparison to operating parameters verified by ground based HCA tests. The flight HCAs continue to operate flawlessly. The first unit has accumulated more than 3650 hours of on-orbit operation and the second unit has accumulated over 5550 hours.

Burke, Tom↗

On the Operational Status of the ISS Plasma Contactor Hollow Cathodes

The Plasma Contactor Unit (PCU) was developed by the Rocketdyne division of The Boeing Company to control charging of the International Space Station (ISS). Each PCU contains a Hollow Cathode Assembly (HCA), which emits the charge control electrons. The HCAs were designed and fabricated at NASA s Glenn Research Center (GRC). GRC's HCA development program included manufacture of engineering, qualification, and flight model HCAs as well as qualification and wear tests. GRC tracks the on-orbit data for the flight HCAs in order to ascertain their overall health. As of April 5, 2004, 43 ignitions and over 6000 hours have been accumulated on a single unit. The flight HCAs continue to operate flawlessly. This paper will discuss the operation of the HCAs during ground tests and on-orbit operation from initial startup to April 30, 2004.

Burke, Thomas P.↗

Development of a Power Electronics Unit for the Space Station Plasma Contactor

A hollow cathode plasma contactor has been baselined as a charge control device for the Space Station (SS) to prevent deleterious interactions of coated structural components with the ambient plasma. NASA LeRC Work Package 4 initiated the development of a plasma contactor system comprised of a Power Electronics Unit (PEU), an Expellant Management Unit (EMU), a command and data interface, and a Plasma Contactor Unit (PCU). A breadboard PEU was designed and fabricated. The breadboard PEU contains a cathode heater and discharge power supply, which were required to operate the PCU, a control and auxiliary power converter, an EMU interface, a command and telemetry interface, and a controller. The cathode heater and discharge supplies utilized a push-pull topology with a switching frequency of 20 kHz and pulse-width-modulated (PWM) control. A pulse ignition circuit derived from that used in arcjet power processors was incorporated in the discharge supply for discharge ignition. An 8088 based microcontroller was utilized in the breadboard model to provide a flexible platform for controller development with a simple command/data interface incorporating a direct connection to SS Mulitplexer/Demultiplexer (MDM) analog and digital I/O cards. Incorporating this in the flight model would eliminate the hardware and software overhead associated with a 1553 serial interface. The PEU autonomously operated the plasma contactor based on command inputs and was successfully integrated with a prototype plasma contactor unit demonstrating reliable ignition of the discharge and steady-state operation.

Hamley, John A.↗

Space station - The next logical step

NASA has been charged with the development, over the next decade, of a permanently manned space station in low earth orbit. The space station system will comprise a manned base and associated unmanned platforms; while one of the platforms will be in polar orbit, another (or several) platforms will, like the manned base, have an orbital inclination of 28.5 deg. Because it is permanent, the space station will have to be semiautonomous from its mission control center. NASA will take a number of steps to foster the commercial utilization of the space station, and one of the design goals of the project is the definition of astronaut facilities that are very 'customer friendly'. Reliance on a single, program-wide contractor has been deemed undesirable; several major aerospace manufacturers will instead distribute responsibility among themselves for the various modules constituting the craft.

Beggs, J. M.↗

Adaptive microwave reflector

As an interim step in going to the 100-meter reflector that was evaluated, a 5-meter reflector is proposed to test the electrostatic concept under space conditions. Some of the issues which require the space environment for evaluation are the following questions: Can deployment of a box ring structure with a thin film reflector attached be manually deployed? In the absence of humidity, can a 0.3-mil aluminized Kapton film reflector be formed by the electrostatic process suitable for antenna applications? Can the photogrammetric process be used to evaluate the reflector surface with pictures taken from the payload handling station? Can the space charging effect be evaluated with the 5-meter reflector attached to the Shuttle? Does the outgassing of moisture from 0.3-mil Kapton film affect its reflector capability? A box ring truss support structure and an automatic sequence deployment system are discussed.

Goslee, J. W.↗

Analysis of a rotating advanced-technology space station for the year 2025

An analysis is made of several aspects of an advanced-technology rotating space station configuration generated under a previous study. The analysis includes examination of several modifications of the configuration, interface with proposed launch systems, effects of low-gravity environment on human subjects, and the space station assembly sequence. Consideration was given also to some aspects of space station rotational dynamics, surface charging, and the possible application of tethers.

Queijo, M. J.↗

The Electrostatic Levitation Facility at NASA's Marshall Space Flight Center

Containerless processing is an important area of research in materials science. Electrostatic levitation (ESL) represents an emerging technology which permits containerless processing in a vacuum environment. NASA's Marshall Space Flight Center (MSFC) established a levitation facility to provide a critical resource to the microgravity materials science research community to continue and enhance ground-based research in the support of the development of flight experiments during the transition to Space Station. During ESL processing, charged specimens are levitated in the electrostatic field produced by the system's electrodes. Three sets of positioning electrodes represent the heart of the MSFC system. Two dual-axis position sensitive detectors provide input for the PID control-loop computer. Sample position is maintained by adjusting the control voltages for the power supplies of the positioning electrodes. A UV source refreshes the charge on specimens during processing via the photoelectric effect. Lasers permit sample heating independent of positioning. The processing chamber typically operates under vacuum condition approximately = 10(exp -7) Torr. Electrostatic levitation provides a materials science research tool for investigations of refractory solids and melts. Topics of investigation include thermophysical properties, phase equilibria, metastable phase formation, undercooling and nucleation, time-temperature-transformation diagrams and other aspects of materials processing. Current capabilities and recent results of processing studies for metals, alloys and oxides will be reviewed.

Rogers, Jan R.↗

Experimental Tests of UltraFlex Array Designs in Low Earth Orbital and Geosynchronous Charging Environments

The present ground based investigations give the first definitive look describing the expected on-orbit charging behavior of Orion UltraFlex array coupons in the Low Earth Orbital and Geosynchronous Environments. Furthermore, it is important to note that the LEO charging environment also applies to the International Space Station as well as to the lunar mission charging environments. The GEO charging environment includes the bounding case for all lunar orbital and lunar surface mission environments. The UltraFlex thin film photovoltaic array technology has been targeted to become the sole power system for life support and on-orbit power for the manned Aires Crew Exploration Vehicle. It is therefore, crucial to gain an understanding of the complex charging behavior to answer some of the basic performance and survivability issues in an attempt to ascertain that a single UltraFlex array design will be able to cope with the projected worst case LEO and GEO charging environments. Testing was limited to four array coupons, two coupons each from two different array manufactures, Emcore and Spectrolab. The layout of each array design is identical and varies only in the actual cell technology used. The individual array cells from each manufacturer have an antireflection layered coating and come in two different varieties either uncoated (only AR coating) or coated with a thin conducting ITO layer. The LEO Plasma tests revealed that all four coupons passed the arc threshold -120 V bias tests. GEO electron gun charging tests revealed that only front side area of ITO coated coupons passed tests. Only the Emcore AR array passed backside Stage 2 GEO Tests.

Galofaro, Joel T.↗

Detection of DNA Damage by Space Radiation in Human Fibroblasts Flown on the International Space Station

Space radiation consists of energetic charged particles of varying charges and energies. Exposure of astronauts to space radiation on future long duration missions to Mars, or missions back to the Moon, is expected to result in deleterious consequences such as cancer and comprised central nervous system (CNS) functions. Space radiation can also cause mutation in microorganisms, and potentially influence the evolution of life in space. Measurement of the space radiation environment has been conducted since the very beginning of the space program. Compared to the quantification of the space radiation environment using physical detectors, reports on the direct measurement of biological consequences of space radiation exposure have been limited, due primarily to the low dose and low dose rate nature of the environment. Most of the biological assays fail to detect the radiation effects at acute doses that are lower than 5 centiSieverts. In a recent study, we flew cultured confluent human fibroblasts in mostly G1 phase of the cell cycle to the International Space Station (ISS). The cells were fixed in space after arriving on the ISS for 3 and 14 days, respectively. The fixed cells were later returned to the ground and subsequently stained with the gamma-H2AX (Histone family, member X) antibody that are commonly used as a marker for DNA damage, particularly DNA double strand breaks, induced by both low-and high-linear energy transfer radiation. In our present study, the gamma-H2AX (Histone family, member X) foci were captured with a laser confocal microscope. To confirm that some large track-like foci were from space radiation exposure, we also exposed, on the ground, the same type of cells to both low-and high-linear energy transfer protons, and high-linear energy transfer Fe ions. In addition, we exposed the cells to low dose rate gamma rays, in order to rule out the possibility that the large track-like foci can be induced by chronic low-linear energy transfer radiation.

Lu, Tao↗

Mid-Latitude Ionospheric Disturbances Due to Geomagnetic Storms at ISS Altitudes

Spacecraft charging of the International Space Station (ISS) is dominated by interaction of the US high voltage solar arrays with the F2-region ionosphere plasma environment. ISS solar array charging is enhanced in a high electron density environment due to the increased thermal electron currents to the edges of the solar cells. High electron temperature environments suppress charging due to formation of barrier potentials on the charged solar cell cover glass that restrict the charging currents to the cell edge [Mandell et al., 2003]. Environments responsible for strong solar array charging are therefore characterized by high electron densities and low electron temperatures. In support of the ISS space environmental effects engineering community, we are working to understand a number of features of solar array charging and to determine how well future charging behavior can be predicted from in-situ plasma density and temperature measurements. One aspect of this work is a need to characterize the magnitude of electron density and temperature variations that occur at ISS orbital altitudes (approximately 400 km) over time scales of days, the latitudes over which significant variations occur, and the time periods over which the disturbances persist once they start. This presentation provides examples of mid-latitude electron density and temperature disturbances at altitudes relevant to ISS using data sets and tools developed for our ISS plasma environment study. "Mid-latitude" is defined as the extra-tropical region between approx. 30 degrees to approx. 60 degrees magnetic latitude sampled by ISS over its 51.6 degree inclination orbit. We focus on geomagnetic storm periods because storms are well known drivers for disturbances in the ionospheric plasma environment.

Minow, Joseph I.↗

The International Space Station Space Radiation Environment: Avionics Systems Performance in Low-Earth Orbit Single Event Effects (SEE) Environments

Single event effects (SEE) are those errors, anomalies, or failures in microelectronic devices caused by the passage of a single energetic charged particle through the device. Spacecraft SEE environments consist primarily of energetic charged particles; both primary particles originating in the natural environment and secondary particles (including secondary neutrons) produced by nuclear reactions of primary particles with spacecraft materials. The energetic charged particle components (electrons, protons, and atomic nuclei) of the spacecraft SEE environment include galactic cosmic rays (GCR), and planetary radiation belt charged particles, as well as solar energetic particle event (SPE) charged particles. The International Space Station (ISS) orbital altitude and inclination (~350 km to ~420 km at 51.6o inclination) results in a spacecraft SEE environment that varies dramatically with the location in Earth?s geomagnetic field. Geomagnetic GCR shielding diminishes with distance from the geomagnetic equator. Near + 51.6o latitude the ISS GCR environment has a high degree of similarity to the interplanetary GCR environment in cis-Lunar space.SEE environments supporting ISS avionics systems design, development, test, and verification are documented in SSP-30512, Space Station Ionizing Radiation Design Environment. Comparisons of overall ISS avionics systems in-flight performance with pre-flight verification report predictions have been previously reported and meet or exceed expectations in all cases.In this paper we report the results of more detailed investigations of the effects of geographic location, altitude, solar cycle, and shielding mass effects on the in-flight SEE performance of the ISS command and data handling system during the past 17 years. In addition, we report on the preflight testing and in-flight performance of the commercial-off-the-shelf lap top computers used on ISS. Finally, we present an assessment of ISS as an avionics SEE test and flight demonstration platform for exploration hardware destined for the cis-lunar or other inner solar system environments.

International Space Station↗