Search NASA⌕ Search

SEARCH · Search NASA

Results for “checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Results of the Analyses of SMECT Mercury Sample Collected During Mercury Pump (MB1) Functional Check

A pump added to remove mercury from the sump of the Slurry Mix Evaporator Condensate Tank (SMECT) in DWPF was successfully tested in 2020, resulting in a sample of contaminated mercury obtained from the Mercury Purification Process (MPP) cell. The mercury in the sump of the SMECT was present as a result of steam stripping of sludge slurry in the Sludge Receipt and Adjustment Tank (SRAT) at DWPF. A schematic of the MPP system provided by DWPF personnel is shown in Appendix A. DWPF personnel supplied the following detailed description of the Hg sampling: “The sample provided is the result of DWPF extraction of mercury by means of the Mercury Pump-Water Cart. The Mercury Pump extracted the sample from the SMECT mercury sump. The pump uses pressurized water to transfer a small amount of mercury to a leachate bucket located at the Lab Mercury cell. The mercury and water were allowed to be self separated, and mercury was gravity decanted from the leachate bucket.” DWPF personnel indicate that the leachate bucket is equipped with both a top stopcock/drain and a lower/bottom stopcock/drain from which the mercury was decanted or drained out, while the separated water layer remained above the mercury during draining. The DWPF customer requested SRNL to analyze the sample for the following: gross alpha/nonvolatile beta analysis and perform a Toxicity Characteristic Leaching Procedure (TCLP) per the Environmental Protection Agency's Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, SW-846. While the TCLP was preferred, a Total Metals analysis of the eight Resource Conservation and Recovery Act (RCRA) metals was deemed acceptable.2 The analytical data collected on this mercury sample will be used in planning for sample disposition as well to start a profile for future Hg disposition of Hg collected from steam stripping.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EQ-SANS Detector Distance Check with Laser Alignment Method

In Small-Angle Scattering experiments, accurate distance information between sample and the detector is important. During the winter outage, January 2021, positions of detector, especially along the beam direction, were measured with the laser alignment tool to confirm values regularly deduced from silver behenate measurements. The results show that the current detector-z position of the EQ-SANS is accurate at all typically used detector positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secure System Composition and Type Checking using Cryptographic Proofs [Slides]

By using zkSNARKs to prove that values have specific dependent types, it is possible to provably assure compatibility and correctness without revealing sensitive information and extend our trusted computing base well beyond our own system. The approach we developed expands the scope of what non-interactive zero-knowledge proofs can capture to include properties about both the execution and correctness of programs.

97 MATHEMATICS AND COMPUTING↗

Check the Storage Stack: Comparing Behind-the-Meter Energy Storage State Policy Stacks in the United States

A variety of studies and disparate datasets track state energy storage polices, but these datasets do not cover all BTM-related storage policy. Moreover, these databases do not align these policies with the policy stacking framework. Thus, it is unclear what BTM storage policies are adopted across the country, what should comprise a complete storage policy framework or stack, and how states policies compare against that stack. This report addresses this gap in the literature by developing a state policy stack for BTM battery storage that we compare across all fifty states. This first-of-its-kind BTM storage policy stack includes 11 parent policy categories, and 31 associated policies divided across the market preparation, creation, and expansion policy components.

25 ENERGY STORAGE↗

Technical Track on Biomass Carbon Removal and Storage (BiCRS): Mapping bioresources, phase 1 - Consistency check comparing Mission Innovation’s Data Visualization Tool for Bioresources and the Clean Energy Ministerial Biofuture Initiative Global Biomass data accessible via the US Department of Energy’s Bioenergy Knowledge Discovery Framework (KDF)

The Mission Innovation (MI) Carbon Dioxide Removal (CDR) Mission, Technical Track on Biomass Carbon Dioxide Removal and Storage (BiCRS), has produced a biomass resource database for its members. In parallel, Oak Ridge National Laboratory (ORNL) developed the International Feedstock Reporting data portal—herein referred to as the CEM Biofuture-KDF data—on behalf of the Clean Energy Ministerial Biofuture Initiative (CEM Biofuture), as a specific task under Biofuture’s 2024–25 Action Plan. This work was conducted at the request of CEM Biofuture and funded by the U.S. Department of Energy in support of that initiative, and it is hosted within DOE’s Knowledge Discovery Framework (KDF).

09 BIOMASS FUELS↗

Checking It Twice: Using [C/N] Masses and Asteroseismic Masses as a Diagnostic of Mass Loss and Transfer on the Red Giant Branch

Red giants experience significant mass loss, but the mechanism is poorly understood. The surface [C/N] of red giants is correlated with birth mass but not directly impacted by mass loss. Exploiting this, we compare asteroseismic masses of red giants with the same [C/N] but different evolutionary states. We find bulk differences between stars at the beginning of the red giant branch (RGB) and in the subsequent evolutionary phase, the red clump, providing a direct constraint on the strength of net RGB mass loss in field stars. We find that net mass loss decreases with metallicity and mass, matching recent studies for field giants but contradicting expectations from the widely used Reimers’s mass-loss formula. We propose a mass- and metallicity-dependent Reimers’s η calibration that reproduces the empirical trends that we see. In addition, we identify 200 stars (3.12% of our sample) that are clear outliers from their population in these birth mass bins, which we believe are likely candidates for mass transfer events. These stars do not show any obvious discrepancies in abundances or binary properties from their counterparts. This population should be accounted for in Galactic archeological studies. Further follow-up is required to quantify their occurrence rate and origin.

Roberts, John D. [The Ohio State Univ., Columbus, ↗

Speculative instruction wakeup to tolerate draining delay of memory ordering violation check buffers

A technique for speculatively executing load-dependent instructions includes detecting that a memory ordering consistency queue is full for a completed load instruction. The technique also includes storing data loaded by the completed load instruction into a storage location for storing data when the memory ordering consistency queue is full. The technique further includes speculatively executing instructions that are dependent on the completed load instruction. The technique also includes in response to a slot becoming available in the memory ordering consistency queue, replaying the load instruction. The technique further includes in response to receiving loaded data for the replayed load instruction, testing for a data mis-speculation by comparing the loaded data for the replayed load instruction with the data loaded by the completed load instruction that is stored in the storage location.

Kalamatianos, John↗

Emulation automation and model checking

A method of automating emulations is provided. The method comprising collecting publicly available network data over a predefined time interval, wherein the collected network data might comprise structured and unstructured data. Any unstructured data is converted into structured data. The original and converted structured data is stored in a database and compared to known network vulnerabilities. An emulated network is created according to the collected network data and the comparison of the structured data with known vulnerabilities. Virtual machines are created to run on the emulated network. Director programs and guest actor programs are run on the virtual machines, wherein the actor programs imitate real user behavior on the emulated network. The director programs deliver task commands to the guest actor programs to imitate real user behavior. The imitated behavior is presented to a user via an interface.

Urias, Vincent↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗