Search NASA⌕ Search

SEARCH · Search NASA

Results for “coaxial cables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

47 records · Page 3

(Paper) TRIPWIRE: Multi-modal Distributed Sensing For Repository Verification

Underground geological repositories for storing used nuclear fuel are being planned and developed around the world. Research is being performed to understand technical aspects of sealing entombed materials and underground repositories to ensure the radiological and nuclear materials remain contained. To support safeguards verification for these facilities research at Idaho National Laboratory (INL) is underway to develop and demonstrate a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. Tamper-indicating self-diagnostic assessments will be done using optical and electronic time domain reflectometry in the SFBs and PCCs, respectively. The result will be a long, kilometer-scale multi-modal SFB-PCC system. Simulation and modeling are being used to inform the work and a demonstration of the system's utility is planned at a nuclear storage facility in the future.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Progress of Tripwire: Multi-Modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Progress of Tripwire: Multi-modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago; Fermilab]↗

Miniature Crack or Damage Detection on Cable Insulation and Jacket Using Conformal Surface Wave Reflectometry

This letter introduces the study and application of a conformal surface wave launcher array to detect miniature insulation and/or jacket damage on unshielded cables. Here simulation and experimental results are presented that demonstrate that with the proposed concept very small instances of damage at various distances along power cables can be detected. Effects of damage detection feasibility in the presence of other cables in proximity and for cables containing semiconducting screen are also presented.

42 ENGINEERING↗

Active Reduction of Apparent Cable Capacitance

This paper presents a method for reducing apparent cable capacitance seen by sensors. The proposed method is designed for sensing in extreme environments including ultra-high temperatures, but can be applied in benign environments as well. By reducing the cable capacitance, high speed signals can be transmitted over longer distances, allowing the application of advanced control systems that require high bandwidth data for stable operation. A triaxial cable with an associated guard circuit is developed that actively reduces cable capacitance while also rejecting extraneous electric and magnetic interference on the signal. The active capacitance reduction method developed is tested experimentally and shown to reduce apparent cable capacitance to two percent of the static value.

47 OTHER INSTRUMENTATION↗

Modular Coaxial Power Converter for High-Density Integration into Medium-Voltage Cables

This work proposes to combine the functionality benefits of power electronics with the power density benefits of medium-voltage cables to create a streamlined, high-density power electronics solution that seamlessly integrates with medium-voltage cables. Located at the ends of a medium- or high-voltage line, the proposed converter uses a cascade of coaxial power conversion cells to gradually step down the voltage, and excels in high step-down applications. By mimicking the coaxial geometry of medium-voltage cables, the converter preserves the axisymmetric electric field of the cable which, when combined with a solid insulating dielectric, provides a voltage scaling advantage over conventional planar and PCB-based converter solutions. Similar to medium voltage cables, the converter is fully passively cooled. A passive cooling strategy allows for combined installation with existing medium voltage cable systems without the added cost, maintenance needs, infrastructure, and reliability concerns associated with active cooling systems. The scalability of the modular structure in combination with the integration benefits provide a flexible power electronics system that can adapt to the evolving demands of the grid.

coaxial power conversion cells↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 50 kA Superconducting Transformer for the Upcoming High-Field High-Current Testing Station at the BNL

Brookhaven national laboratory is upgrading its existing user facility to support R&D for High Energy Physics (HEP) and Fusion Energy Sciences (FES). The goal of this upgrade is to host the testing of the superconducting cables, conductors, joints and insert coils under high magnetic field (10 T), with currents up to 50 kA (present limit 20 kA) and at temperatures varying from 4 K to 40 K. To provide a current up to 50 kA to the sample, a superconducting core-less transformer is under construction. The superconducting transformer would additionally reduce the heat loss at the current leads at high currents. The SC transformer consists of two coaxial coils. The primary coil is inside the secondary coil. The primary coil consists of 3048 turns of rectangular wires (1.91 mm x 1.27 mm), wound in 24 layers. The secondary coil consists of 13 turns of the secondary cable (18.35 mm x 5.96 mm), wound in one layer. The parameters of the transformer are chosen to satisfy the space restrictions while using the available conductor. Here this paper presents the design of the 50-kA transformer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An SF 6 gas-insulated −500 kV DC conical insulator vacuum feedthrough

A test electrode was biased to −500 kV direct current (DC) by means of a novel SF 6 gas-insulated conical alumina insulator feedthrough. The design enables the extreme high vacuum conditions required by spin-polarized electron sources by reducing the photogun vacuum chamber volume compared to coaxial cylindrical insulators. In contrast to conventional inverted-insulator photogun designs that rely on solid dielectric interfaces for high-voltage terminations, the present design employs a pressurized SF 6 intervening volume between a conical alumina insulator and a modified commercial epoxy high-voltage cable receptacle. Here, this approach enables the use of commercially available cable hardware while extending the demonstrated operating voltage of solid feedthroughs. A maximum voltage of −500 kV was applied to a test electrode attached to the narrow end of the feedthrough inside a chamber filled with SF 6 at 170.3 kPa (10 psig) and later under vacuum to −259 kV, limited by field emission. The results demonstrate that a commercial high-voltage cable combined with a custom-designed SF 6 gas-insulated vacuum feedthrough can be used to bias photogun electrodes to −500 kV DC.

Palacios-Serrano, Gabriel [Thomas Jefferson Nation↗