Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Initial conditional effect on pressure waves in an axisymmetric jet

A pair of microphones (separated axially by 5.08 cm and laterally by 1.3 cm) are placed on either side of the jet centerline to investigate coherent pressure fluctuations in an axisymmetric jet at Strouhal numbers less than unity. Auto-spectra, transfer-function, and coherence measurements are made for a tripped and untripped boundary layer initial condition. It was found that coherent acoustic pressure waves originating in the upstream plenum chamber propagate a greater distance downstream for the tripped initial condition than for the untripped initial condition. In addition, for the untripped initial condition the developmet of the coherent hydrodynamic pressure waves shifts downstream.

Miles, Jeffrey H.↗

Investigation of Acoustic Fields for the Cassini Spacecraft: Reverberant Versus Launch Environments

The characterization and understanding of the acoustic field within a launch vehicle's payload fairing (PLF) is critical to the qualification of a spacecraft and ultimately to the success of its mission. Acoustic measurements taken recently for the Cassini mission have allowed unique opportunities to advance the aerospace industry's knowledge in this field. Prior to its launch, the expected liftoff acoustic environment of the spacecraft was investigated in a full-scale acoustic test of a Titan IV PLF and Cassini simulator in a reverberant test chamber. A major goal of this acoustic ground test was to quantify and verify the noise reduction performance of special barrier blankets that were designed especially to reduce the Cassirii acoustic environment. This paper will describe both the ground test and flight measurements, and compare the Cassini acoustic environment measured during launch with that measured earlier in the ground test. Special emphasis will be given to the noise reduction performance of the barrier blankets and to the acoustic coherence measured within the PLF.

Hughes, William O.↗

Core noise measurements from a small, general aviation turbofan engine

As part of a program to investigate combustor and other core noises, simultaneous measurements of internal fluctuating pressure and far field noise were made with a JT15D turbofan engine. Acoustic waveguide probes, located in the engine at the combustor, at the turbine exit and in the core nozzle wall, were used to measure internal fluctuating pressures. Low frequency acoustic power determined at the core nozzle exit corresponds in level to the far field acoustic power at engine speeds below 65% of maximum, the approach condition. At engine speeds above 65% of maximum, the jet noise dominates in the far field, greatly exceeding that of the core. From coherence measurements, it is shown that the combustor is the dominant source of the low frequency core noise. The results obtained from the JT15D engine were compared with those obtained previously from a YF102 engine, both engines having reverse flow annular combustors and being in the same size class.

Reshotko, M.↗

Core noise measurements from a small, general aviation turbofan engine

As part of a program to investigate combustor and other core noises, simultaneous measurements of internal fluctuating pressure and far field noise were made with a JT15D turbofan engine. Acoustic waveguide probes, located in the engine at the combustor, at the turbine exit and in the core nozzle wall, were used to measure internal fluctuating pressures. Low frequency acoustic power determined at the core nozzle exit corresponds in level to the far-field acoustic power at engine speeds below 65% of maximum, the approach condition. At engine speeds above 65% of maximum, the jet noise dominates in the far-field, greatly exceeding that of the core. From coherence measurements, it is shown that the combustor is the dominant source of the low frequency core noise. The results obtained from the JT15D engine were compared with those obtained previously from a YF102 engine, both engines having reverse flow annular combustors and being in the same size class.

Reshotko, M.↗

Requirements and Technology Advances for Global Wind Measurement with a Coherent Lidar: A Shrinking Gap

Early concepts to globally measure vertical profiles of vector horizontal wind from space planned on an orbit height of 525 km, a single pulsed coherent Doppler lidar system to cover the full troposphere, and a continuously rotating telescope/scanner that mandated a vertical line of sight wind profile from each laser shot. Under these conditions system studies found that laser pulse energies of approximately 20 J at 10 Hz pulse repetition rate with a rotating telescope diameter of approximately 1.5 m was required. Further requirements to use solid state laser technology and an eyesafe wavelength led to the relatively new 2-micron solid state laser. With demonstrated pulse energies near 20 mJ at 5 Hz, and no demonstration of a rotating telescope maintaining diffraction limited performance in space, the technology gap between requirements and demonstration was formidable. Fortunately the involved scientists and engineers set out to reduce the gap, and through a combination of clever ideas and technology advances over the last 15 years, they have succeeded. This paper will detail the gap reducing factors and will present the current status.

Kavaya, Michael J.↗

Design of a near-IR coherent lidar for high spatial and velocity resolution wind measurement

A coherent Doppler lidar based on a CW diode-pumped, injection seeded, Th:YAG laser operating at approx. 2.02 microns is currently under development. This system is optimized for measurements of boundary layer winds with high spatial, temporal, and velocity resolution. Initially, the system will run alongside a new high repetition rate (5-10 kHz) CO2 mini-Master Oscillator Power Amplifier (mini-MOPA) Doppler lidar, which will provide simultaneous range-resolved Differential Absorption Lidar (DIAL) water vapor measurements. Water vapor DIAL operation of the 2 micron system is being considered as a future option. The anticipated specifications and the preliminary design are discussed.

Grund, Christian J.↗

High-speed holocinematographic velocimeter for studying turbulent flow control physics

Use of a dual view, high speed, holographic movie technique is examined for studying turbulent flow control physics. This approach, which eliminates some of the limitations of previous holographic techniques, is termed a holocinematographic velocimeter (HCV). The data from this system can be used to check theoretical turbulence modeling and numerical simulations, visualize and measure coherent structures in 'non-simple' turbulent flows, and examine the mechanisms operative in various turbulent control/drag reduction concepts. This system shows promise for giving the most complete experimental characterization of turbulent flows yet available.

Weinstein, L. M.↗

Rotational branch analysis of the excitation of the fundamental vibrational modes of CO2 by slow electron collisions

At 2 eV, the simultaneous rotational-vibrational cross sections for the fundamental modes are found to be well described by the Born formula with just long-range interactions. However, this result is not obtained for pure vibrational excitation (Q branch) in the Raman-active Fermi diads. At 3.8 eV, the infrared-active v2 and v3 cross sections agree with a previous theory incorporating resonant and direct scattering coherently. Measurements on the Raman-active v1 mode indicate that theories need to account for the Fermi resonance.

Antoni, TH.↗

Holocinematographic Velocimeter

Holographic movies used to study turbulent flows. High-speed movie composed of single-exposure holograms of tracer particles in each of two simultaneous orthogonal views of flow. Time resolution set by movie frame rate, and total time limited by length of movie. Data from system used to verify results of theoretical models and numerical simulations of turbulence, visualize and measure coherent structures in "non-simple" turbulent flows, to examine mechanisms operative in various turbulence-control/drag-reduction concepts.

Weinstein, Leonard M.↗

Development of rotorcraft interior noise control concepts. Phase 2: Full scale testing, revision 1

The phase 2 effort consisted of a series of ground and flight test measurements to obtain data for validation of the Statistical Energy Analysis (SEA) model. Included in the gound tests were various transfer function measurements between vibratory and acoustic subsystems, vibration and acoustic decay rate measurements, and coherent source measurements. The bulk of these, the vibration transfer functions, were used for SEA model validation, while the others provided information for characterization of damping and reverberation time of the subsystems. The flight test program included measurements of cabin and cockpit sound pressure level, frame and panel vibration level, and vibration levels at the main transmission attachment locations. Comparisons between measured and predicted subsystem excitation levels from both ground and flight testing were evaluated. The ground test data show good correlation with predictions of vibration levels throughout the cabin overhead for all excitations. The flight test results also indicate excellent correlation of inflight sound pressure measurements to sound pressure levels predicted by the SEA model, where the average aircraft speech interference level is predicted within 0.2 dB.

Yoerkie, C. A.↗

Development of a coded 16-ary CPFSK coherent demodulator

Theory and hardware are described for a proof-of-concept 16-ary continuous phase frequency shift keying (16-CPFSK) digital modem. The 16 frequencies are spaced every 1/16th baud rate for 2 bits/sec/Hz operation. Overall rate 3/4 convolutional coding is incorporated. The demodulator differs significantly from typical quadrature phase detector approaches in that phase is coherently measured by processing the baseband output of a frequency discriminator. Baud rate phase samples from the baseband processor are decoded to yield the original data stream. The method of encoding onto the 16-ary phase nodes, together with convolutional coding gain, results in near quad PSK (QPSK) performance. The modulated signal is of constant envelope; thus the power amplifier can be saturated for peak performance. The spectrum is inherently bandlimited and requires no RF filter.

Clarke, Ken↗

Optical synchronization of millimeter-wave oscillators for distributed architecture

A review of various methods of phase and frequency synchronization of active MMIC based transmit/receive modules is presented, and particular emphasis is placed on the synchronization of oscillators through the use of an indirect subharmonic optical injection locking technique. In this approach, the nonlinear behavior of large-signal modulated laser diodes and solid-state oscillators is exploited to extend the bandwidth of the synchronizing link to the millimeter-wave frequency range. Experimental results of the phase and frequency coherency of two 21.5 GHz FET oscillators are reported. Optimum performance is achieved at a subharmonic factor of 1/4, with a locking range of 84 MHz and a phase noise degradation of only 14 dB. The phase coherency measurement of two injection-locked oscillators points to a phase shift, which is introduced as a result of the frequency detuning between the slave and master oscillator signals. A scheme to correct for this phase error is presented.

Daryoush, Afshin S.↗

Measurement of the Correlation and Coherence Lengths in Boundary Layer Flight Data

Wall pressure data acquired during flight tests at several flight conditions are analyzed and the correlation and coherence lengths of the data reported. It is shown how the frequency bandwidth of the analysis biases the correlation length and how the convection of the flow acts to reduce the coherence length. Coherence lengths measured in the streamwise direction appear much longer than would be expected based on classical results for flow over a flat plat.

Palumbo, Daniel L.↗

Phase average measurements of the coherent structure in a Mach number 0.6 jet

Phase averaged measurements of the axial mass velocity, radial velocity, and the product of the two have been made in an artificially excited cold air jet. The radial velocity fluctuations had a lower amplitude for both the full wave and phase averaged fluctuations compared to the axial mass velocity fluctuations. The Reynolds stress tended to decay faster in amplitude than the axial mass velocity and radial velocity fluctuations for both the full wave and phase averaged components. The radial velocity fluctuations possessed higher levels of coherence than the axial mass velocity fluctuation and the Reynolds stress. When the jet was excited at the frequency of St = 0.474, a high amplitude component at that frequency dominated the entire phase averaged flowfield from X/D = 1 to 10. This fundamental frequency was accompanied by several relatively high amplitude harmonics. These harmonics were more pronounced in the radial velocity fluctuations than for the axial fluctuations or the Reynolds stress.

Emami, S.↗

Parameter Trade Studies For Coherent Lidar Wind Measurements of Wind from Space

The design of an orbiting wind profiling lidar requires selection of dozens of lidar, measurement scenario, and mission geometry parameters; in addition to prediction of atmospheric parameters. Typical mission designs do not include a thorough trade optimization of all of these parameters. We report here the integration of a recently published parameterization of coherent lidar wind velocity measurement performance with an orbiting coherent wind lidar computer simulation; and the use of these combined tools to perform some preliminary parameter trades. We use the 2006 NASA Global Wind Observing Sounder mission design as the starting point for the trades.

Kavaya, Michael J.↗

Coherent Lidar Turbulence Measurement for Gust Load Alleviation

Atmospheric turbulence adversely affects operation of commercial and military aircraft and is a design constraint. The airplane structure must be designed to survive the loads imposed by turbulence. Reducing these loads allows the airplane structure to be lighter, a substantial advantage for a commercial airplane. Gust alleviation systems based on accelerometers mounted in the airplane can reduce the maximum gust loads by a small fraction. These systems still represent an economic advantage. The ability to reduce the gust load increases tremendously if the turbulent gust can be measured before the airplane encounters it. A lidar system can make measurements of turbulent gusts ahead of the airplane, and the NASA Airborne Coherent Lidar for Advanced In-Flight Measurements (ACLAIM) program is developing such a lidar. The ACLAIM program is intended to develop a prototype lidar system for use in feasibility testing of gust load alleviation systems and other airborne lidar applications, to define applications of lidar with the potential for improving airplane performance, and to determine the feasibility and benefits of these applications. This paper gives an overview of the ACLAIM program, describes the lidar architecture for a gust alleviation system, and describes the prototype ACLAIM lidar system.

Bogue, Rodney K.↗

High Repetition Rate Pulsed 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed at NASA Langley Research Center. Such a laser transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of approximately 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. The measured standard deviation of the laser frequency jitter is about 3 MHz.

Singh, Uprendra N.↗

2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

Carbon dioxide (CO2) has been recognized as one of the most important greenhouse gases. It is essential for the study of global warming to accurately measure the CO2 concentration in the atmosphere and continuously record its variation. A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed in NASA Langley Research Center. This laser system is capable of making a vertical profiling of CO2 from ground and column measurement of CO2 from air and space-borne platform. The transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of ~50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. A Ho:YLF laser operating in the range of 2.05 micrometers can be tuned over several characteristic lines of CO2 absorption. Experimentally, a diode pumped Ho:Tm:YLF laser has been successfully used as the transmitter of coherent differential absorption lidar for the measurement of CO2 with a repetition rate of 5 Hz and pulse energy of 75 mJ. For coherent detection, high repetition rate is required for speckle averaging to obtain highly precise measurements. However, a diode pumped Ho:Tm:YLF laser can not operate in high repetition rate due to the large heat loading and up-conversion. A Tm:fiber laser pumped Ho:YLF laser with low heat loading can operate in high repetition rate. A theoretical model has been established to simulate the performance of Tm:fiber laser pumped Ho:YLF lasers. For continuous wave (CW) operation, high pump intensity with small beam size is suitable for high efficiency. For Q-switched operation, the optimal energy extraction relies on the pump intensity, pump volume, and pump duration which is inversely proportion to the repetition rate. CW and Q-switched Ho:YLF lasers with different linear cavity configurations have been designed and demonstrated for a 30 W Tm:fiber pump laser. The CW Ho laser slope efficiency and optical-to-optical efficiencies reach 65% and 55%, respectively. The pulsed laser efficiency depends on the repetition rate. For 1 kHz operation, the optical-to-optical efficiency is 39% when the pump power is 14.5W. Currently, the injection seeding success rate is between 99.4% and 99.95%. After a ten thousand pulses, the standard deviation of the laser frequency jitter is about 3 MHz. It meets the requirements of highly precise CO2 concentration measurement. In conclusion, an injection seeded, high repetition rate, Q-switched Ho:YLF laser has been developed for a coherent CO2 differential absorption lidar. This master-slave laser system has high optical-to-optical efficiency and seeding success rate. It can potentially meet the requirements of the coherent detection of CO2 concentration by a differential absorption lidar technique.

Singh, Upendra N.↗