Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Measurements of low-mode asymmetries in the areal density of laser-direct-drive deuterium–tritium cryogenic implosions on OMEGA using neutron spectroscopy

Areal density is one of the key parameters that determines the confinement time in inertial confinement fusion experiments, and low-mode asymmetries in the compressed fuel are detrimental to the implosion performance. The energy spectra from the scattering of the primary deuterium–tritium (DT) neutrons off the compressed cold fuel assembly are used to investigate low-mode nonuniformities in direct-drive cryogenic DT implosions at the Omega Laser Facility. For spherically symmetric implosions, the shape of the energy spectrum is primarily determined by the elastic and inelastic scattering cross sections for both neutron-deuterium and neutron-tritium kinematic interactions. Two highly collimated lines of sight, which are positioned at nearly orthogonal locations around the OMEGA target chamber, record the neutron time-of-flight signal in the current mode. An evolutionary algorithm is being used to extract a model-independent energy spectrum of the scattered neutrons from the experimental neutron time-of-flight data and is used to infer the modal spatial variations (l = 1) in the areal density. Experimental observations of the low-mode variations of the cold-fuel assembly (ρL 0 + ρL 1 ) show good agreement with a recently developed model, indicating a departure from the spherical symmetry of the compressed DT fuel assembly. As a result, another key signature that has been observed in the presence of a low-mode variation is the broadening of the kinematic end-point due to the anisotropy of the dense fuel conditions.

47 OTHER INSTRUMENTATION↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Impact of Shifts in Vegetation Phenology on the Carbon Balance of a Semiarid Sagebrush Ecosystem

Dryland ecosystems are critical in regulating the interannual variability of the global terrestrial carbon cycle. The responses of such ecosystems to weather and environmental conditions remain important factors that limit the accurate projections of carbon balance under future climate change. Here, we investigated how shifts in vegetation phenology resulting from changes in weather and environmental conditions influenced ecosystem carbon cycling in one semiarid ecosystem in the Hanford area of central Washington, United States. We examined two years of measurements of the phenology camera, eddy covariance, and soil chamber from an upland semiarid sagebrush ecosystem. Both years had contrasting diel and seasonal patterns of CO 2 fluxes, primarily driven by differences in vegetation phenology. The net ecosystem exchange of CO 2 (NEE) and evapotranspiration (ET) in 2019 were enlarged by shifted vegetation phenology, as a cold and snow-covered winter and warm and dry winter in 2020 resulted in constrained magnitudes of NEE and ET during the summer months. The annual gross primary productivity (GPP) was much higher in 2019 than in 2020 (-211 vs. -112 gC m -2 ), whereas ecosystem respiration was comparable in these two years (164 vs. 144 gC m -2 ). Thus, the annual NEE in 2019 was negative (-47 gC m -2 ) with the sagebrush ecosystem functioning as a carbon sink, while the positive annual NEE in 2020 indicated that the sagebrush ecosystem functioned as a carbon source. Our results demonstrate that winter snowpack can be a critical driver of annual carbon uptake in semiarid sagebrush ecosystems.

59 BASIC BIOLOGICAL SCIENCES↗

Cyber-Physical Simulation of the Cold Startup of Solid Oxide Fuel Cell – Gas Turbine (SOFC-GT) Hybrid Systems

This work introduces experimental studies for the cold startup process (CPS) of the SOFC-GT hybrid system using the cyber-physical simulation approach. The physical gas turbine is coupled with a cyber-physical SOFC stack, which is represented using the integration of a real time dynamic SOFC model with physical components (e.g., pressure chamber, natural gas burner, etc.). Different ramp rates of the turbine speed were tested out during the startup processes. Bypass valves were also used to manipulate the airflow during SOFC-GT hybrid system start-up process. Different ramp rates enable the rapid start-up of the turbine to avoid surge and stall, meanwhile enable acceptable warm rate of the fuel cell stack without damaging the cell material. CPS can enable dynamic characterizations of highly integrated systems at lower cost.

Zhou, Nana↗

Thermal conductivity of RHIC superconducting magnet insulation materials at low temperatures

The Electron-Ion Collider (EIC) is planned to be built upon the Relativistic Heavy Ion Collider (RHIC), which vacuum chamber will need to be upgraded to host the EIC hadron beams. For the beam pipe section running through the RHIC superconducting (SC) magnets, the baseline is to insert a screen that will get cooled by thermal contact to the 4.55 K beam pipe of RHIC. Knowing the material properties of the cold mass is thus crucial to understand which is the final temperature that the screen and the superconducting coils in the magnets will reach during the passage of the EIC beams. The thermal conductivities of two insulation materials in the RHIC superconducting magnets and a reference material were measured at cryogenic temperatures at the Magnet Science and Technology division of the National High Magnetic Field Laboratory (NHMFL). The measurements were performed in a Quantum Design physical property measurement system. This report explains the motivation behind this work and summarizes the measurement method and results.

43 PARTICLE ACCELERATORS↗

Organisation of Diverse Mechanisms of Secondary Ice Production among Basic Convective and Stratiform Cloud-types

This 3-year DoE-funded joint project had the over-arching aim of understanding how ice is initiated in clouds of various types. Focus was given to processes of fragmentation of pre-existing ice, which can occur in positive feedback loops (‘ice multiplication’). A basic question to address was which fragmentation processes prevail in which basic cloud-types. The approach was to use cloud models and field observations, while pioneering our own lab observations of ice initiation to break the deadlock from the past lack of lab observations. Historically, the tendency of the cloud physics community to avoid doing lab observations has allowed a vast gap in knowledge about ice initiation to persist for decades. During the first part of the project, new formulations were created to treat two overlooked types of fragmentation of ice. First, sublimational breakup of ice was treated based on a theoretical formula that we fitted to a pooled dataset of lab observations published previously in the literature. Second, a new mode of fragmentation of freezing raindrops was treated, which involves a supercooled drop being hit by a more massive ice particle. Some of the secondary droplets from the impact freeze. This work was done at Manchester University by Co-I Connolly. Then during the second part, both formulations were implemented in our ‘aerosol-cloud model’ (AC). AC has a hybrid bin/bulk microphysics scheme, and now represents four processes of SIP. The accuracy of AC was evaluated for four cases typifying four basic cloud-types: slightly cold-based stratiform cloud and cold-, warm- and very warm-based convective clouds. We discovered that the warmth of cloud-base, especially in the tropics, promotes SIP processes of raindrop-freezing fragmentation and rime-splintering, and surprisingly, sublimational breakup too. It was found that breakup in ice-ice collisions is ubiquitous. Finally, a portable laboratory chamber was constructed at Lund and deployed in northern Sweden to observe breakup in graupel-snow collisions outdoors. This was seen to be even more prolific than treated in our 2018 formulation. Papers describing results are either published or soon to be published.

54 ENVIRONMENTAL SCIENCES↗

Warming and Increased Respiration Have Transformed an Alpine Steppe Ecosystem on the Tibetan Plateau From a Carbon Dioxide Sink Into a Source

Cold region ecosystems store vast amounts of soil organic carbon (C), which upon warming and decomposition can affect the C balance and potentially change these ecosystems from C sinks to carbon dioxide (CO 2 ) sources. We quantified the decadal year-round CO 2 flux from an alpine steppe-ecosystem on the Tibetan Plateau using eddy covariance and automatic chamber approaches during a period of significant warming (0.13°C per 10 years; and 0.18°C in the non-growing season alone: 1st October to next 30th April). The results showed that ongoing climate change, mainly warming within the topsoil layers, is the main reason for the site’s change from a sink for to a source of CO 2 in the atmosphere. Non-growing-season ecosystem respiration accounted for 51% of the annual ecosystem respiration and has increased significantly. The growing seasons (1st May to 30th September) were consistent CO 2 sink periods without significant changes over the study period. Observations revealed high-emission events from the end of the non-growing season to early in the growing season (1st March to fifteenth May), which significantly (p < 0.01) increased at a rate of 22.6 g C m -2 decade -1 , ranging from 14.6 ± 10.7 g C m -2 yr -1 in 2012 to 35.3 ± 12.1 g C m -2 yr -1 in 2017. Further, structural equation modeling suggested that active layer warming was the key factor in explaining changes in ecosystem respiration, leading to significant changes in net ecosystem exchange over the period 2011–2020 and indicated that these changes have already transformed the ecosystem from a CO 2 sink into a source. These results can be used to improve our understanding of the sensitivity of ecosystem respiration to increased warming during the non-growing period.

58 GEOSCIENCES↗

The ProtoDUNE-SP LArTPC electronics production, commissioning, and performance

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low electronic noise pre-amplifier and digitization ASICs integrated into Front End Motherboards (FEMBs) operating at cryogenic temperature within the cryostat. The large number of electronics channels and high performance specifications required a large-scale production electronics quality control effort, careful installation into Anode Plane Assemblies (APAs), and rigorous detector commissioning. This successful collaboration-wide effort achieved a working LArTPC electronics channel percentage of 99.7% (15,318 of 15,360 channels in total), whose operating performance exceeded expectations. We summarize the ProtoDUNE-SP cold electronics design and quality control, installation, and commissioning efforts that enabled this excellent electronics performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermoradiative energy conversion in infrared interband cascade InAs/GaSb/AlInSb/GaSb type-II superlattice diodes

Thermoradiative energy conversion presents a means for the direct conversion of thermal energy through radiative transfer to a cold scene. However, much of the study of thermoradiative principles has been based on theory and simulations, with only sparse reports on the experimental demonstration of the concept. This work studies thermoradiative energy conversion in InAs/GaSb/AlInSb/GaSb type-II superlattice cascade devices. The devices exhibit a cutoff wavelength of 3.2 μm at 300 K, corresponding to a bandgap of 0.39 eV. Testing under a temperature-controlled chamber and scene demonstrates a maximum power density of 2.9 mW/m2 at a cell temperature of 121 °C. It is consistent with expected values for device operation limited by Shockley–Read–Hall non-radiative recombination. This result is a significant step in providing an experimental demonstration of thermoradiative energy conversion and a means to characterize cell performance, providing a foundation for further development to achieve practical values for power generation.

Islam, Md Toriqul (ORCID:0000000249871320)↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Short-Pulse Laser-Based Diagnostics for Pulsed Power-Driven Warm Dense Matter

This report summarizes a research project conducted at the Physics Department’s Zebra Pulsed Power Laboratory (ZPPL) at the University of Nevada Reno, aimed at developing short-pulse laser-based diagnostics to probe pulsed-power-driven warm dense matter. ZPPL combines a MegaAmpere (MA) pulsed power generator, Zebra, and a relativistic intensity, short-pulse laser, Leopard, offering a unique university-scale platform for high energy density physics, laboratory astrophysics, and inertial fusion energy research. The project focused on establishing a hard X-ray radiographic capability using high-intensity, short-pulse laser-generated X-rays to probe warm dense matter created by the Zebra current. Initial experiments produced X-ray radiographs of a static (cold) aluminum wire using silver and gold foil and wire targets, but intense background radiation from Zebra shots overwhelmed the laser-produced X-rays. To mitigate this, a radiationhardened detector housing was designed and implemented. Additional diagnostic, including a filter stack bremsstrahlung spectrometer and an X-ray pinhole camera, were developed to characterize laser-produced hard X-ray spectra and locate hard X-ray sources in the vacuum chamber. These revealed that strong hard X-rays (> 20 keV) originated near the anode cap, bombarded by energetic electrons. Due to laser unavailability during some experiments, detector performance was successfully tested using hard X-ray sources from the Zebra current, demonstrating their readiness for coupled experiments. The project supported one Ph.D. student (Dr. Lei Chen), who conducted experimental and numerical research, and provided training opportunities and data for three undergraduate senior theses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory Investigations of Aerosol-Cloud Interactions in an Entraining, Turbulent Environment (Final Technical Report)

The effects that aerosol particles have on clouds in Earth’s atmosphere and the role that clouds play in determining the fate of aerosol particles play a crucial role in determining the human experience on this planet. These interwoven interactions can determine whether it rains or snows, is comfortable, hot or cold, or whether the cloud you gaze at in the sky looks like a tiger or a lump of porridge. How clouds mix with the air surrounding them, a process known as entrainment, further affects these processes. We conducted laboratory experiments of aerosol-cloud interactions in a setting in which we can measure the effects of entrainment – the first laboratory experiments since the pioneering work of Latham and Reed in 1977. We measured the effects of entrainment on aerosol-cloud interactions in the Pi Chamber and also used a state-of-the-art large eddy simulation (LES) to investigate processes in fine detail.

54 ENVIRONMENTAL SCIENCES↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

Effects of Pollen on Hydrometeors and Precipitation in a Convective System

Anemophilous (wind-driven) pollen is one type of primary biological aerosol particle, which can rupture under high humidity conditions and form smaller sub-pollen particles (SPPs). Both pollen and SPPs can reach the upper troposphere under convective conditions, acting as cloud condensation nuclei (CCN) and ice nucleating particles (INPs), thus influencing cloud formation and precipitation. However, the impacts of these biological aerosols on cold cloud formation and local climate remain unclear as there are large uncertainties on their emission flux and ice nucleating abilities. Here, we incorporate pollen emission and rupture processes in the Weather Research and Forecasting Model with Chemistry (WRF-Chem) simulations and update the Morrison microphysics scheme within WRF-Chem using aerosol-aware INP parameterizations to account for pollen in addition to other anthropogenic and biogenic aerosol. INP parameterizations for pollen and SPP are derived from laboratory experiments. When including pollen rupture rates as observed in a series of chamber studies, SPP concentrations increase, leading to an increase of cloud ice and water by up to 50% and potentially extending the duration of the convective system. Among all simulated hydrometeors, graupel and raindrops exhibit the largest enhancements from the inclusion of SPPs, with intensifying precipitation at the backside of the convective system and a greater spatial extent. Sensitivity simulations indicate that SPPs have a greater effect on cloud microphysical processes than whole pollen grains, and further observational evidence is needed to constrain these processes.

54 ENVIRONMENTAL SCIENCES↗

Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector

The Short-Baseline Neutrino (SBN) program at Fermilab will pursue neutrino properties searches, exploiting three Liquid Argon Time Projection Chamber (LArTPC) experiments to investigate neutrino oscillations with neutrinos from the Booster Neutrino Beam (BNB). SBND will be the near detector in the program, measuring the un-oscillated flux. It is anticipated to begin operating in 2023. Thanks to its peculiar proximity to the neutrino source of about 110 meters, SBND will collect extremely high statistics data of the flux in the GeV energy range, providing unprecedented precision measurements. SBND particular setting also allows to take measurements at different distances from BNB’s center maintaining statistics high enough at each range. LArTPC and the cold electronics technologies, as well as the argon-neutrino interaction studies, will play a key role in future neutrino physics. In this prospect, this work was focused on two SBND features: SBND PRISM tool, with the aim of investigating neutrino flux at different distances from the beam axis, and Purity Monitors, which provide a clever measurement of argon purity in the detector, whose value is fundamental in neutrino-argon interaction.

43 PARTICLE ACCELERATORS↗

Prediction of Climate-Specific Degradation Rate for Photovoltaic Encapsulant Discoloration

Encapsulant discoloration is a well-known field degradation mode of crystalline-silicon photovoltaic modules, particularly in the hot climate zones. The discoloration rate is influenced by several weathering factors, such as UV light, module temperature, and humidity, as well as the permeability of oxygen into the module. Here, a rate dependence model employing the modified Arrhenius equations to predict the degradation rate for encapsulant discoloration in different climates is presented. Two modeling approaches are introduced, which utilize the field and accelerated UV testing degradation data in conjunction with the field meteorological data to determine the acceleration factor for encapsulant browning. A novel method of accelerated UV stress testing at three simultaneous module temperatures in a single environmental chamber test run is implemented to estimate the activation energy for browning. The test was performed on three field-retrieved modules to capture the wear-out failure mechanism. The degradation in short-circuit current Isc rather than maximum power is used as a decisive parameter for the discoloration analysis. Furthermore, the developed model has been used to predict the Isc degradation rate for the Arizona field characterized by a hot and dry climate and is validated against the field-measured value. It has also been applied to other climate types, e.g., the cold and dry climate of New York.

14 SOLAR ENERGY↗

An energy model of droplet impingement on an inclined wall under isothermal and non-isothermal environments

The observation of spray-wall interaction is of great importance to understand the dynamics that occur during fuel impingement onto the chamber wall or piston surfaces in internal combustion engines. It is found that the maximum spreading length of an impinged droplet can provide a quantitative estimation of heat transfer and energy transformation for spray-wall interaction. Furthermore, it influences the air-fuel mixing and hydrocarbon and particle emissions at combusting conditions. In this paper, an analytical model of different droplet-wall impingement conditions is developed in terms of βm (dimensionless maximum spreading length, the ratio of maximum spreading length to initial droplet diameter) to understand the detailed impinging dynamic process. These conditions are grouped as: a single diesel droplet impinging on the wall with different inclined angles (α); cold wall - heated droplet and heated wall - cold droplet impingement when inclined angle of the wall is 0°, respectively. The analytical model is built up based on the energy conservation that considers kinetic energy, gravitation energy, and surface energy before impingement, as well as viscous dissipation, gravitation energy, adhesion energy, deformation energy, and heat energy after impingement. The experimental work of diesel droplet impinging on an inclined wall is performed at a certain range of the Weber number (We of 33 to 420) with various inclined angles (α of 0° to 45°), while for inclined angle is 0°, droplet and wall temperature are varied from 25°C to 150°C to study the effects of the inclined angle and temperature on the temporal evolution of the post-impingement characteristics (i.e. droplet spreading length, dynamic contact angle). The analytical model is validated and evaluated at the aforementioned experimental operating points. The validated model can be employed to predict maximum spreading length of the droplet impinged on the wall. It is further utilized to determine the transition from capillary regime to kinetic regime, then to viscous regime at different inclined angle of the wall.

42 ENGINEERING↗