Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Influence of injection-induced cooling on deviatoric stress and shear reactivation of preexisting fractures in Enhanced Geothermal Systems

Cold water injection into a hot, fractured, geothermal reservoir may trigger shear activation of pre-existing fractures that can help to enhance reservoir permeability, but may also result in unwanted seismicity. In this study, we investigate through numerical modeling of a hypothetical geothermal reservoir how injection-induced cooling may influence the potential for shear activation, paying special attention to the evolution of deviatoric stress under various stress regimes. In each case, we consider either a reservoir with homogeneous hydraulic properties or the presence of a more permeable fracture zone intersecting the injection well. This fracture zone is either oriented in the maximum (S Hmax ) or minimum (S hmin ) horizontal stress direction. Finally, our main finding is that depending on the configuration, injection-induced cooling stresses can favor or prevent shear reactivation of the preexisting fracture, and this effect can vary temporally and spatially.

58 GEOSCIENCES↗

Validation of Play Fairway Analysis of the geothermal potential of Camas Prairie, south-central Idaho, by an exploration well

Abstract Play Fairway Analysis (PFA) methodology was adapted for geothermal exploration at Camas Prairie, Idaho. Geophysical data, structural and geologic mapping, volcanic rock ages and vent locations, and the distribution of thermal springs and wells all indicated a relatively high geothermal potential along the southern margin of the Prairie. An exploration well (USU Camas-1) was drilled to a depth of 618.3 m to validate the PFA. A permeable zone was encountered at ~ 357.5 m with a maximum measured temperature of ~ 80 °C, which was suppressed following the injection of cold water. A moderate transmissivity of ~ 0.25–1 cm 2 /s estimated from an injection test as well a seasonal artesian flow at ~ 0.7 L/s corroborate the presence of a permeable zone. The existence of a lacustrine clay seal was confirmed near the bottom of the basin-fill sediment occupying the upper 314 m of the well. Geothermometers suggest the USU Camas-1 well water equilibrated at a reservoir temperature of ~ 120 °C. Based on the locations of both thermal and cold wells, geothermal fluids appear to be flowing upward along one or both of two fault systems. The presence of young basalts and elevated helium isotope ratios suggest that the heat source of Camas Prairie is magmatic. However, the faults may be acting as a conduit for geothermal fluids to rise from great depth without a shallow magmatic source being present. Camas Prairie is a promising area for geothermal development, but the relatively low reservoir temperatures indicate this resource may not be suitable for electric generation. Perhaps the best use would be for heating.

Lachmar, Thomas E. (ORCID:0000000249640119)↗

Increased Use of Natural Gas in Blast Furnace Ironmaking: Mass and Energy Balance Calculations

In blast furnace ironmaking, coke can be partially replaced by injected natural gas. Tuyère injection of cold natural gas is commonly practiced in North America. In this work, limits to the tuyère injection rate have been quantified with mass and energy balances. The fundamental origin of the limits is the endothermicity of methane injection. In principle, shaft injection of preheated and partially combusted methane would obviate the endothermic effect. However, the thermal and chemical energy parameter indicates that the energy requirement in the lower part of the furnace—to melt hot metal and slag—might not be met in the case of shaft injection. Tuyère injection of preheated methane might be a feasible alternative. Calculated combustion kinetics support the feasibility of partial combustion of preheated methane (with sub-stoichiometric oxygen) before injection.

36 MATERIALS SCIENCE↗

Perturbative transport modeling of cold-pulse dynamics in Alcator C-Mod Ohmic plasmas

Perturbative transport experiments in magnetically confined plasmas have shown, for more than 20 years, that the injection of cold pulses at the plasma edge can trigger the increase of core temperature. Predictive heat transport simulations with the trapped gyro Landau fluid (TGLF) quasilinear transport model demonstrate that the increase of core temperature in some regimes, and lack thereof in other regimes, can be explained by a change in dominant linear micro-instability in Alcator C-Mod. The effect of density and plasma current on the cold pulse are well captured by TGLF, including the relative change in position of the temperature flex point as current density changes. Linear stability analysis of simulated density and current scans reveals a competition between trapped electron and ion temperature gradient modes as the main driver of the core transient response. Here these results further demonstrate that cold-pulse propagation and associated phenomenology in the cases studied are well explained within the local transport paradigm, without resorting to non-local effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local transport dynamics of cold pulses in tokamak plasmas

Abstract For over two decades, our fundamental understanding of energy transport dynamics in the core of tokamak plasmas had been challenged by the striking observation of temperature perturbation reversals following the injection of cold pulses at the plasma edge. These phenomena were first discovered by Gentle et al. (Phys. Rev. Lett. 74(18):3620–3623, 1995) in 1995 and had long been suggested to be evidence of nonlocal transport effects. In recent years, a new explanation to these phenomena has emerged, fully consistent with the theory of turbulent transport in magnetized plasmas and in remarkable agreement with experiment. This article reviews the experimental observation of temperature reversals in tokamak plasmas and presents the explanation based on local transport physics.

Rodriguez-Fernandez, P. (ORCID:0000000273611131)↗

High-resolution time-resolved experiments on mixing and entrainment of buoyant jets in stratified environments

Fluid jets interacting with a stratified layer play an important role in the safety of several reactor designs. In the containment of nuclear power plants, fluid jets dominate the transport and mixing of gaseous species and consequent hydrogen distribution in case of a severe accident. The mixing phenomena in the containment are driven by buoyant high-momentum injections (jets) and low momentum injection plumes. Mixing near the postulated break is initially dominated by high flow velocities. Plumes with moderate flow velocities are instead relevant in the break compartment during the long-term pressurization phase, or in any of the apertures between two connected compartments if the mass flows are sufficiently high and the density differences between efflux and ambient are sufficiently low. Phenomena of interest include free plumes (as produced by the efflux from the break compartment in a larger room or directly from a break flow), wall plumes (such those produced by low mass flows through inter-compartment apertures), and propagating stratification fronts in the ambient (for any stably stratified conditions). These phenomena have been highly ranked about nuclear reactor design, especially regarding of safety protocols. During a Pressurized Thermal Shock (PTS) scenario, the interaction between the cold ECCS injection plume and the stratified fluid present in the cold (or hot) leg is important in order to determine the temperature at the time-dependent temperature at the inlet of the reactor pressure vessel (RPV) and the potential to cause a thermal shock on the RPV wall. In sodium-cooled fast reactors (SFRs), core channels are typically hydro-dynamically isolated so that there exists a considerable temperature variation at the exit of adjacent fuel assemblies. All the above phenomena are characterized by the interaction of buoyant jets with the stratified flow. In stratified layers baroclinic forces create significant redistribution of turbulent kinetic energy and scales, which leads to anisotropy. This important physical phenomenon is highly three dimensional and is challenging to capture even with high-fidelity CFD simulations, due in part to lack of sufficiently resolved validation data. Furthermore, the experimental data available in the open literature do not feature the level of fidelity needed for an extensive validation of turbulence models in lower order CFD. To shed new lights into the crucial phenomena object of the present research project, it was proposed to conduct coordinated experiments and simulations at the University of Michigan and the George Washington University. The project has resulted in an experimental database of high-resolution time-resolved measurements of jets in uniform and stratified environments. The novel experimental data will be used to validate computational fluid dynamic (CFD) codes, including both Large Eddy Simulations (LES) and unsteady Reynolds-averaged Navier-Stokes equations (URANS) methodologies. In the Experimental and Multiphase flow (ECMF) laboratory at Univerisity of Michigan, we built two experimental facilities to investigate also the effect of scaling. The first facility, DESTROJER (DEnsity Stratified Turbulent ROund free Jet ExpeRiment), featuring a contoured jet nozzle with a diameter of D=12.7mm and a 1m×1m×1m cubic tank, which is made of acrylic glass for optical access. The ratio between the tank width and the nozzle diameter is equal to 78, which ensures that there is no direct interaction between the jet and the side walls. A second, modular experimental facility, features three different tank sizes of size 10×10×30, 20×20×30, 30×30×30 cm3 respectively (all tanks have the same height of 30 cm), and a jet diameter of 2mm. For the modular facility, tank-to-nozzle ratio of 50, 100, and 150 are obtained respectively. Experiments with different-density jet impactions and sharp interface with a density difference of 3.16% In the Laboratory at George Washington University, complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A mechanism for a class of solar coronal disturbances

A new ideal magnetohydrodynamic (MHD) model is used to examine the dynamical response of the upper solar atmosphere to the injection of cold mass from the photosphere, a surge perturbation. Theoretical results show that mass ejections from the photosphere will form loop structures with internally-moving plasma blobs, which is due to the mass injections from both legs in active regions leading to a reflection of waves at the top of the loop. The mass-loaded loop will remain as long as ejection continues, and will excite MHD waves propagating outward to the upper atmosphere, which may trigger a class of coronal disturbances.

Wu, S. T.↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Using distributed temperature sensing to detect CO 2 leakage along the injection well casing

The objective of this study is to evaluate the sensitivity of Distributed Temperature Sensing (DTS) data to detect CO 2 leakage along an injection well casing. This paper describes the relationship between the CO 2 leakage rate and temperature response at DTS locations, and the method and numerical model used for understanding such a relationship. The uncertainties in the parameters are propagated to the interpretation of DTS measurements, which may lead to false positive and false negative identifications of CO 2 leakage. We propose to identify CO 2 leakage by analyzing both temperature history plots at selected vertical locations as well as the vertical temperature profiles at different times. The analysis should be combined with numerical simulations for the estimation of leakage rates. In addition, leakage needs to be confirmed by data from a warm-up test (temperature recovery after injection of cold CO 2 is stopped) to minimize the probability of false identifications.

42 ENGINEERING↗

Development of A High Performance Cold Climate Heat Pump

The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested compression technologies is a lower discharge temperature, which allows for continued operation at lower ambient temperatures. A bin analysis of the vapor injected prototype cold climate heat pump predicts a 6% improvement in HSPF for Minneapolis. This improvement is mainly a result of the increased capacity of the system for active vapor injection. For the oil flooded system, a slightly larger performance improvement is predicted, in this case mostly caused by an increase in heating COP. Based on an economic analysis of these results, the maximum additional cost of the system changes, for the Minneapolis location, are $\$430$ for the vapor injected system and $\$391$ for the oil flooded system. These estimates assume that a 3-year simple payback period is accepted by the customer. For the hybrid flow control of evaporators, a new type of balancing valve was developed together with Emerson Climate technologies to reduce the cost of the control scheme. In contrast to conventional stepper motor valves, this valve requires less cables and can be driven by a cheaper output circuit on the control board. The correct valve size was determined in a dedicated test stand in several design iterations. The performance benefits of the hybrid control of the evaporator coil were determined for clean coil conditions as well as with partial blockage of the air inlet grille and under frosting conditions. For clean coil conditions, the benefits in terms of COP and capacity are negligible. However, significant benefits were noted for severely air-maldistributed operating conditions. For the H2-test, the maximum COP improvement of 17% along with a capacity improvement of nearly 40% was observed. Overall, the hybrid control scheme leads to a significant amount of performance improvement, if the air inlet conditions to the evaporator are maldistributed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Fluid Dynamics Simulation of Dual Bell Nozzle Film Cooling

Marshall Space Flight Center (MSFC) and Armstrong Flight Research Center (AFRC) are working together to advance the technology readiness level (TRL) of the dual bell nozzle concept. Dual bell nozzles are a form of altitude compensating nozzle that consists of two connecting bell contours. At low altitude the nozzle flows fully in the first, relatively lower area ratio, nozzle. The nozzle flow separates from the wall at the inflection point which joins the two bell contours. This relatively low expansion results in higher nozzle efficiency during the low altitude portion of the launch. As ambient pressure decreases with increasing altitude, the nozzle flow will expand to fill the relatively large area ratio second nozzle. The larger area ratio of the second bell enables higher Isp during the high altitude and vacuum portions of the launch. Despite a long history of theoretical consideration and promise towards improving rocket performance, dual bell nozzles have yet to be developed for practical use and have seen only limited testing. One barrier to use of dual bell nozzles is the lack of control over the nozzle flow transition from the first bell to the second bell during operation. A method that this team is pursuing to enhance the controllability of the nozzle flow transition is manipulation of the film coolant that is injected near the inflection between the two bell contours. Computational fluid dynamics (CFD) analysis is being run to assess the degree of control over nozzle flow transition generated via manipulation of the film injection. A cold flow dual bell nozzle, without film coolant, was tested over a range of simulated altitudes in 2004 in MSFC's nozzle test facility. Both NASA centers have performed a series of simulations of that dual bell to validate their computational models. Those CFD results are compared to the experimental results within this paper. MSFC then proceeded to add film injection to the CFD grid of the dual bell nozzle. A series of nozzle pressure ratios and film coolant flow rates are investigated to determine the effect of the film injection on the nozzle flow transition behavior. The results of this CFD study of a dual bell with film injection are presented in this paper.

Braman, Kalen↗

1D Heat Loss Models Validation Experiment

Contains data from the model validation in the 1D Heat Loss Models to Predict the Aquifer Temperature Profile during Hot/Cold Water Injection Project. The data include two COMSOL models (2D axisymmetric benchmark model and 2D Vinsome model), one python code (1D Vinsome based FEM numerical simulation), one matlab main code (1D Newton analytical solution and all results comparison visualization), and output files generated from the above models.

1D↗

Magnetic Separatrix as the Source Region of the Plasma Supply for an Active-region Filament

Solar filaments can be formed via chromospheric evaporation followed by condensation in the corona or by the direct injection of cool plasma from the chromosphere to the corona. We here confirm with high-resolution H α data observed by the 1.6 m New Solar Telescope of the Big Bear Solar Observatory on 2015 August 21 that an active-region filament is maintained by the continuous injection of cold chromospheric plasma. We find that the filament is rooted along a bright ridge in H α , which corresponds to the intersection of a magnetic quasi-separatrix layer with the solar surface. This bright ridge consists of many small patches whose sizes are comparable to the width of the filament threads. It is found that upflows originate from the brighter patches of the ridge, whereas the downflows move toward the weaker patches of the ridge. The whole filament is composed of two opposite-direction streams, implying that longitudinal oscillations are not the only cause of the counterstreamings, and unidirectional siphon flows with alternative directions are another possibility.

79 ASTRONOMY AND ASTROPHYSICS↗

Next generation modeling of microbial souring – Parameterization through genomic information

Biogenesis of hydrogen sulfide (H 2 S) (microbial souring) has detrimental impacts on oil production operations and can cause health and safety problems. Understanding the processes that control the rates and patterns of sulfate reduction is crucial in developing a predictive understanding of reservoir souring and associated mitigation processes. This work demonstrates an approach to utilize genomic information to constrain the biological parameters needed for modeling souring, providing a pathway for using microbial data derived from oil reservoir studies. Minimum generation times were calculated based on codon usage bias and optimal growth temperatures based on the frequency of amino acids. We show how these derived parameters can be used in a simplified multiphase reactive transport model by simulating the injection of cold (30 °C) seawater into a 70 °C reservoir, modeling the shift in sulfate reducing microorganisms (SRM) community composition, sulfate and sulfide concentrations through time and space. Finally, we explore the question of necessary model complexity by comparing results using different numbers of SRM. Simulations showed that the kinetics of a SRM community consisting of twenty-five SRM could be adequately represented by a reduced community consisting of nine SRM with parameter values derived from the mean and standard deviations of the original SRM.

54 ENVIRONMENTAL SCIENCES↗

Biofilm Feedbacks Alter Hydrological Characteristics of Fractured Rock Impacting Sulfidogenesis and Treatment

Flow-through fractures dominate the movement of fluids in a variety of natural as well as engineered subsurface systems. Microbial activities in fractured rock impact subsurface energy recovery, storage, and waste disposal. It has been recognized that understanding how the contrasting permeability between fracture and matrix interacts with microbial metabolism under thermal and hydrological gradients is key to effective utilization of the subsurface, yet such studies are sparse. Microorganisms mediate the production of hydrogen sulfide (also known as souring) in oil-bearing geological formations. We conducted a comprehensive experimental study of a novel 2D fractured rock system to understand these complex interactions and demonstrated how biofilm development can impact fracture flow, which subsequently feedbacks to moderate sulfidogenesis. Elevated temperature relevant to reservoir conditions interacted with the injection of cold fluid and formed a thermal gradient away from fractures, creating thermal niches for microbial activities in the fractured rock. Finally, results showed that while fracture flows were dominant in the beginning, with time, growth of the biofilm in the fractures reduced permeability, effectively moderating the initial fracture-matrix contrast, and limited microbial accessibility to nutrients and subsequent reactions rates.

59 BASIC BIOLOGICAL SCIENCES↗

Scaling Behavior of Thermally Driven Fractures in Deep Low‐Permeability Formations: A Plane Strain Model With 1‐D Heat Conduction

Abstract Injection of cold fluids through/into deep formations may cause significant cooling, thermal stress, and possible thermal fracturing. In this study, the thermal fracturing of low‐permeability formations under one‐dimensional heat conduction was investigated using a plane strain model. Dimensionless governing equations, with dimensionless fracture length , aperture , spacing , time , and effective confining stress , were derived. Solution of single thermal fracture was derived analytically, while solution of multiple fractures with constant (or dynamic) spacing were obtained using the displacement discontinuity method (and stability analysis). For single fracture, increases nonlinearly with and then transitions to scaling law , indicating that late‐time fracture length increases linearly with the square root of cooling time. For constantly spaced fractures, deviates from the single‐fracture solution at a later for a larger , showing slower propagation under inter‐fracture stress interaction . For dynamically spaced fractures, fracture arrest induced by stress interaction was determined by the stability analysis; the fully transient solution provides evolution of dimensionless fracture length, spacing, aperture, and pattern; a similar scaling law, with , obtained shows the effect of both stress interaction and fracture arrest. The solution and scaling law provide fast predictions for all reservoir and cooling conditions using (single) model parameter . Application to a geothermal site with demonstrates that thermal fractures reach 0.67, 6.25, and 78.00 m in length, 0.49, 2.30, and 13.00 m in spacing, and 0.43, 2.09, and 12.19 mm in aperture at 1, 100, and 10,000 days.

Chen, Bin↗

Heliostat Aiming Strategies for Arbitrary Flux Profiles for High Temperature Gas-Based Receivers

High temperature gas-based receivers are seen as one potential path toward achieving the next generation of concentrated solar power tower systems. A key challenge associated with high temperature, high pressure heat transfer fluids is the lifetime of receiver containment materials. Achieving the desired lifetime while also designing an efficient receiver requires implementation of unique flux profiles, tailored to place high fluxes at cold fluid injection points. An aimpoint selection methodology was developed in the present study to allow user-defined flux profiles to be prescribed for a receiver. The methodology was implemented in NREL's open-source software SolarPILOT, modifying the existing “image size priority” aimpoint strategy. A case study for a tubular gas-based receiver is presented, examining the effect of various parameters on the ability to replicate the desired flux profile.

41 EE - Solar Energy Technologies Office (EE-4S)↗

On the correlation between ‘non-local’ effects and intrinsic rotation reversals in Alcator C-Mod

Contemporary predictive models for heat and particle transport in tokamak plasmas are based on the assumption that local fluxes can be described in terms of local plasma parameters, where electromagnetic drift-wave-type turbulence is driven by local gradients and results in cross-field transport. The question of whether or not transport could be dominated by non-local terms in certain circumstances is essential for our understanding of transport in magnetically confined plasmas, and critical for developing predictive models for future tokamaks, such as ITER. Perturbative transport experiments using cold-pulse injections at low density seem to challenge the local closure of anomalous transport: a rapid temperature increase in the core of the plasma following a sharp edge cooling is widely observed in tokamaks and helical devices. Past work in Ohmic plasmas in Alcator C-Mod and in ECH plasmas in KSTAR found that the temperature inversions disappear at higher densities, above the intrinsic toroidal rotation reversal density. These observations suggested that the so-called 'non-local' heat transport effects were related to the intrinsic rotation reversal, and therefore to changes in momentum transport. In this work, new experiments and analysis at Alcator C-Mod show that intrinsic rotation reversals and disappearance of temperature inversions are not concomitant in Ohmic plasmas at high plasma current and in ICRH L-modes. This new data set shows that the correlation between transient temperature inversions and intrinsic rotation reversals is not universal, suggesting that 'non-local' heat transport and momentum transport effects may be affected by different physical mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗