Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold weather”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during an NG shortage over one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73-bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dispatch is proposed to allow the representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

dual-fuel capable generator↗

Hygrothermal simulation of exterior retrofits in a cold climate

This work presents results from moisture modeling as part of a project undertaken by Pacific Northwest National Laboratory and its research partners, the University of Minnesota, and the Oak Ridge National Laboratory. The research goal is to identify exterior wall retrofit systems for cold climates that are low cost, energy efficient, and do not result in moisture durability problems. A base case wall was identified representing a typical wood frame construction, circa 1950. Retrofit options were selected based on input from industry, academia, and published work and seven options were constructed and installed at the University of Minnesota’s cold weather exposure facility in Cloquet, MN. Measurements were carried out during winter months and the data was used for model validation. Hygrothermal simulations were then carried out using WUFI (Version 6.4) in accordance with standard ANSI/ASRHAE 160-2016, Criteria for Moisture-Control Design Analysis in Buildings. Simulations were run out to three years and results show that the exterior retrofits improve thermal performance and do not negatively impact moisture durability of the existing wall.

Aldykiewicz Jr, Antonio↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Limited surface impacts of the January 2021 sudden stratospheric warming

Subseasonal weather prediction can reduce economic disruption and loss of life, especially during “windows of opportunity” when noteworthy events in the Earth system are followed by characteristic weather patterns. Sudden stratospheric warmings (SSWs), breakdowns of the winter stratospheric polar vortex, are one such event. They often precede warm temperatures in Northern Canada and cold, stormy weather throughout Europe and the United States - including the most recent SSW on January 5th, 2021. Here we assess the drivers of surface weather in the weeks following the SSW through initial condition “scrambling” experiments using the real-time CESM2(WACCM6) Earth system prediction framework. We find that the SSW itself had a limited impact, and that stratospheric polar vortex stretching and wave reflection had no discernible contribution to the record cold in North America in February. Instead, the tropospheric circulation and bidirectional coupling between the troposphere and stratosphere were dominant contributors to variability.

54 ENVIRONMENTAL SCIENCES↗

Multiphysics and Multiscale Modeling of Coupled Transport of Chloride Ions in Concrete

Chloride ions (Cl−)-induced corrosion is one of the main degradation mechanisms in reinforced concrete (RC) structures. In most situations, the degradation initiates with the transport of Cl− from the surface of the concrete towards the reinforcing steel. The accumulation of Cl− at the steel-concrete interface could initiate reinforcement corrosion once a threshold Cl− concentration is achieved. An accurate numerical model of the Cl− transport in concrete is required to predict the corrosion initiation in RC structures. However, existing numerical models lack a representation of the heterogenous concrete microstructure resulting from the varying environmental conditions and the indirect effect of time dependent temperature and relative humidity (RH) on the water adsorption and Cl− binding isotherms. In this study, a numerical model is developed to study the coupled transport of Cl− with heat, RH and oxygen (O2) into the concrete. The modeling of the concrete microstructure is performed using the Virtual Cement and Concrete Testing Laboratory (VCCTL) code developed by the U.S. National Institute of Standards and Technology (NIST). The concept of equivalent maturation time is utilized to eliminate the limitation of simulating concrete microstructure using VCCTL in specific environmental conditions such as adiabatic. Thus, a time-dependent concrete microstructure, which depends on the hydration reactions coupled with the temperature and RH of the environment, is achieved to study the Cl− transport. Additionally, Cl− binding isotherms, which are a function of the pH of the concrete pore solution, Cl− concentration, and weight fraction of mono-sulfate aluminate (AFm) and calcium-silicate-hydrate (C-S-H), obtained from an experimental study by the same authors are utilized to account for the Cl− binding of cement hydration products. The temperature dependent RH diffusion was considered to account for the transport of Cl− with moisture transport. The temperature and RH diffusion in the concrete domain, composite theory, and Cl− binding and water adsorption isotherms are used in combination, to estimate the ensuing Cl− diffusion field within the concrete. The coupled transport process of heat, RH, Cl−, and O2 is implemented in the Multiphysics Object-Oriented Simulation Environment (MOOSE) developed by the U.S. Idaho National Laboratory (INL). The model was verified and validated using data from multiple experimental studies with different concrete mixture proportions, curing durations, and environmental conditions. Additionally, a sensitivity analysis was performed to identify that the water-to-cement (w/c) ratio, the exposure duration, the boundary conditions: temperature, RH, surface Cl− concentration, Cl− diffusion coefficient in the capillary water, and the critical RH are the important parameters that govern the Cl− transport in RC structures. In a case study, the capabilities of the developed numerical model are demonstrated by studying the complex 2D diffusion of Cl− in a RC beam located in two different climatic regions: warm and humid weather in Galveston, Texas, and cold and dry weather in North Minnesota, Minnesota, subjected to time varying temperature, RH, and surface Cl− concentrations.

composite theory↗

Improved Prediction of Cold-Air Pools in the Weather Research and Forecasting Model Using a Truly Horizontal Diffusion Scheme for Potential Temperature

The terrain-following vertical coordinate system used by many atmospheric models, including the Weather Research and Forecasting (WRF) Model, is prone to errors in regions of complex terrain. These errors stem, in part, from the calculation of horizontal gradients within the diffusion term of the momentum or scalar evolution equations. In WRF, such gradients can be calculated along coordinate surfaces, or using metric terms that help account for grid skewness. However, neither of these options ensures a truly horizontal gradient calculation, especially if a grid cell is skewed enough that the heights of the neighboring grid points used in the calculation fall outside the vertical range of the cell. In this work, an improved scheme that uses Taylor series approximations to vertically interpolate variables to the level necessary for a truly horizontal gradient calculation is implemented in WRF for the diffusion of potential temperature. The scheme is validated using an atmosphere-at-rest configuration, in which spurious flows develop only as a result of numerical errors and can thus be used as a proxy for model performance. Following validation, the method is applied to the simulation of cold-air pools (CAPs), which occur in regions of complex terrain and are characterized by strong near-surface temperature gradients. Using the truly horizontal scheme, idealized simulations demonstrate reduced numerical mixing in a quiescent CAP, and a realistic case study in the Columbia River basin shows a reduction in positive wind speed bias by up to roughly 20% compared to observations from the Second Wind Forecast Improvement Project.

54 ENVIRONMENTAL SCIENCES↗

Modeling Spatial Asymmetries in Teleconnected Extreme Temperatures

Abstract Combining strengths from deep learning and extreme value theory can help describe complex relationships between variables where extreme events have significant impacts (e.g., environmental or financial applications). Neural networks learn complicated nonlinear relationships from large datasets under limited parametric assumptions. By definition, the number of occurrences of extreme events is small, which limits the ability of the data-hungry, nonparametric neural network to describe rare events. Inspired by recent extreme cold winter weather events in North America caused by atmospheric blocking, we examine several probabilistic generative models for the entire multivariate probability distribution of daily boreal winter surface air temperature. We propose metrics to measure spatial asymmetries, such as long-range anticorrelated patterns that commonly appear in temperature fields during blocking events. Compared to vine copulas, the statistical standard for multivariate copula modeling, deep learning methods show improved ability to reproduce complicated asymmetries in the spatial distribution of ERA5 temperature reanalysis, including the spatial extent of in-sample extreme events.

Krock, Mitchell L.↗

How Time Inefficient and Uncertain are Paratransit Trips Compared to Car Trips

The Americans with Disabilities Act (ADA) stipulates that paratransit mobility be comparable to public transit. However, with just under 5% of the population relying on public transportation, transit is not a representative benchmark. To highlight this inequality, we compare trip times by paratransit to counterfactual car-based travel. Using 2.5 years of demand data from the Denver Regional Transportation District's Access-a-Ride service, we compare paratransit trip times to counterfactual car-based trips for the same origin-destination pairs, controlling for various trip characteristics. Compared to car travel, the findings indicate high variability and uncertainty associated with paratransit trip times. For the same origin-destination pairs, the mean paratransit trip time is almost twice that of the mean car travel time, with a standard deviation for paratransit trip time fourfold that of the standard deviation for car trip time. For perspective, traveling an average of 10 mi during the 7-8 a.m. morning peak can take about 16 min by car with almost no variability, while that same trip can take an average of 25 min by paratransit, with 5% of trips being outside the 95% confidence interval and thus unpredictable. Paratransit trip time inefficiency tends to be particularly worse for females; older adults; those making trips between 9 and 11 a.m.; cash-paying customers; those making shorter trips; and those traveling during inclement weather, including cold temperatures. These findings suggest a need to re-assess using public transit as a benchmark for paratransit supply as regulated by the ADA.

accessible transportation and mobility↗

Expanding Solar Research and Generation for a Bright Energy Future (Final Technical Report)

This project supported the construction of an outdoor solar research facility for the primary purpose of characterizing panel and system lifetimes in the northern New England climate which features cold winters and warm, humid summers. The facility is designed to be integrated into future efforts to explore the impacts of the New England climate on energy storage and grid integration, as well as methods to mitigate factors like snow and dust coverage in the industrial and agricultural environment of the Intervale farming community and the McNeil wood-fired power generating station. It will provide year-round renewable energy research opportunities for faculty and students. As renewable energy generation and storage have become research priorities for UVM, for the state of Vermont, and for the United States as a whole, this facility will benefit the public on a broad range of scales.

14 SOLAR ENERGY↗

Form Follows Function (F3): A framework for community-based energy resilience planning in the Midwest

This is the final technical report for the Form Follows Function (F3) grant project led by the City of Duluth, MN. F3 was an innovative two-year initiative that created a replicable, human-centered energy resilience planning process specifically designed for smaller, cold-climate communities in the Midwest. F3 demonstrated both systems-level government planning and community-based research techniques to inform renewable investments and community preparedness strategies.

14 SOLAR ENERGY↗

Quick Start to Electrifying Your School Bus Fleet

Learn how electric school buses can work for your district by understanding the basics of electrification. Understand what is needed to electrify your fleet, how much it costs, and how the process will effect your greenhouse gas emission impacts.

ADVANCED PROPULSION SYSTEMS↗

Updated weather model captures subtleties of cold-air pool events

Imagine cold air building up inside a valley or other topographic basin, like a cold swimming pool in the atmosphere. Known in meteorology as cold-air pools, or simply cold pools, these events affect wind plant power production in two key ways. Because they are associated with stagnant air and low winds near the ground, cold pools can severely limit wind energy output over periods of hours to days. Then, when cold pools dissolve, known as cold pool “erosion,” increased wind speeds allow wind power production to recover.

Energy↗

Observational Study of the Thermodynamics and Morphological Characteristics of a Midlatitude Continental Cold Pool Event

Abstract Convectively generated cold pools are important to the Earth system as they exert strong controls on deep convective-storm initiation, intensity, and life cycle. Despite their importance, efforts to introduce such cold pool controls into weather and climate models lack guidance and/or physical constraints from cold pool observations. This work presents a detailed, purely observational analysis of a cold pool event that took place on 23–24 May 2011 in north-central Oklahoma. The characteristics of the cold pool, and the spatiotemporal evolution of the hydrometeors and dynamics in the proximity of the cold pool, are studied with high-resolution observations. The unprecedented dataset used in this work to study cold pool characteristics includes an enhanced network of surface weather stations, a high-temporal-frequency sounding array, and the NEXRAD and Atmospheric Radiation Measurement (ARM) Southern Great Plains radar networks. The potential use of NEXRAD surveillance scans to estimate height and propagation speed of the leading edge of the cold pool (LECP) is presented in this work. Manual identification and tracking of the LECP from NEXRAD imagery shows a spatial and temporal heterogeneity of the LECP properties. Surprisingly, over its detected life cycle, the LECP speed remains almost constant, even though the strength of the cold pool diminishes in time and its height varies. Radar analysis shows that pulses of graupel and hail within downdrafts in the convective system generating the cold pool appeared to be related to temporary increases in the LECP height.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulated wind speed and initial conditions over the WFIP2 region: Sea-breeze (D01)

The purpose of this work is to assess the sensitivity of the forecast for turbine height wind speed to initial condition (IC) uncertainties over the Columbia River Gorge and Columbia River Basin for two typical weather phenomena: a local thermal gradient induced by a marine air intrusion and passage of a cold front. The Weather Research and Forecasting (WRF) model data assimilation system (WRFDA) was used to generate ensemble ICs from the North American Regional Analysis (NARR) for the WRF model initialization. The simulated turbine-height wind speeds were categorized into four types using the self-organizing map (SOM) technique. This work advances understanding of IC uncertainties impacts on wind speed forecasts and locates the high-impact regions.

17 WIND ENERGY↗

Simulated wind speed and initial conditions over the WFIP2 region: Sea-breeze (D02)

The purpose of this work is to assess the sensitivity of the forecast for turbine height wind speed to initial condition (IC) uncertainties over the Columbia River Gorge and Columbia River Basin for two typical weather phenomena: a local thermal gradient induced by a marine air intrusion and passage of a cold front. The Weather Research and Forecasting (WRF) model data assimilation system (WRFDA) was used to generate ensemble ICs from the North American Regional Analysis (NARR) for the WRF model initialization. The simulated turbine-height wind speeds were categorized into four types using the self-organizing map (SOM) technique. This work advances understanding of IC uncertainties impacts on wind speed forecasts and locates the high-impact regions.

17 WIND ENERGY↗

Energy Data from Heat Pumps Installed in Juneau, AK

Heat pumps offer a great low carbon emission method to heat homes. Thermalize Juneau 2021 was a clean energy campaign that helped homeowners in Juneau, Alaska install heat pumps into their homes. Juneau is located near the climactic limit of many heat pumps, and we were interested in how well the heat pumps can function in cold climates. This was done by using Sense meters to remotely monitor the energy usage of 10 homes with heat pumps. The Sense meters are small devices that connect to the electrical panel and monitor the energy use of multiple appliances through machine learning. First, we recorded the energy usage of a heat pump in the lab using both the Sense meter and the existing lab datalogger. Both recorded very similar energy usage data which confirmed that the Sense meter can accurately measure the fluctuations in the heat pump energy use. Next, we looked at the energy data from the Sense meters in the homes with heat pumps and paired it with local weather data to see how well the heat pumps functioned in the cold weather.

Alaska↗

Oxygen stress mitigation for microalgal biomass productivity improvement in outdoor raceway ponds

Dissolved oxygen (DO) concentrations at supersaturated levels are commonly observed in outdoor microalgae cultures due to photosynthesis during periods of rapid growth. Paradoxically, the photosynthetically generated oxygen is inhibitory and lowers biomass productivity, therefore, increasing the cost of microalgal biofuels. In this study, photosynthetic rates of Monoraphidium minutum 26B-AM and Scenedesmus obliquus UTEX393, two of the top DISCOVR strains, were compared at three DO levels, 0, 8, and 30 mg L -1 . Increasing DO from 0 to 30 mg L -1 caused a 36.6% and 26.1% reduction in photosynthetic rate for M. minutum 26B-AM and S. obliquus UTEX393, respectively. To improve the outdoor pond biomass productivity of each strain, three oxygen stress mitigation methods were tested. The first method raised the dissolved bicarbonate concentration by an order of magnitude to favor bicarbonate transport into the cell, increasing the CO 2 :O 2 ratio near RuBisCO, thus reducing photorespiration. Although this method increased the observed photosynthesis rate of M. minutum 26B-AM by 26% and S. obliquus UTEX393 by 13% in laboratory testing, it failed to improve biomass productivity under outdoor pond conditions for both strains. The second method added sodium sulfite as an oxygen scavenger to chemically lower the DO concentration in the culture. Chemical reduction of dissolved molecular oxygen did not significantly improve the biomass productivity of M. minutum 26B-AM; however, a 10% improvement in biomass productivity for S. obliquus UTEX393 was observed. The final method sparged cultures with air to strip oxygen out of the liquid medium. This did not improve the biomass productivity of M. minutum 26B-AM, likely due to unfavorable weather conditions during cold season cultivation; however, an improvement of 36% in biomass productivity was achieved for S. obliquus UTEX393 during the warm season cultivation. Of the three tested methods, air-sparging was the most effective and practical for improving outdoor biomass production.

59 BASIC BIOLOGICAL SCIENCES↗