Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multi-Model Assessment of the Factors Driving Stratospheric Ozone Evolution Over the 21st Century

The evolution of stratospheric ozone from 1960 to 2100 is examined in simulations from fourteen chemistry-climate models. There is general agreement among the models at the broadest levels, showing column ozone decreasing at all latitudes from 1960 to around 2000, then increasing at all latitudes over the first half of the 21st century, and latitudinal variations in the rate of increase and date of return to historical values. In the second half of the century, ozone is projected to continue increasing, level off or even decrease depending on the latitude, resulting in variable dates of return to historical values at latitudes where column ozone has declined below those levels. Separation into partial column above and below 20 hPa reveals that these latitudinal differences are almost completely due to differences in the lower stratosphere. At all latitudes, upper stratospheric ozone increases throughout the 21st century and returns to 1960 levels before the end of the century, although there is a spread among the models in dates that ozone returns to historical values. Using multiple linear regression, we find decreasing halogens and increasing greenhouse gases contribute almost equally to increases in the upper stratospheric ozone. In the tropical lower stratosphere an increase in tropical upwelling causes a steady decrease in ozone through the 21st century, and total column ozone does not return to 1960 levels in all models. In contrast, lower stratospheric and total column ozone in middle and high latitudes increases during the 21st century and returns to 1960 levels.

Oman, L. D.↗

Multi-Model Assessment of the Factors Driving the Ozone Evolution Over the 21st Century

The evolution of ozone from 1960 to 2100 is examined in simulations from fourteen chemistry-climate models. There is general agreement among the models at the broadest levels, with all showing column ozone decreasing at all latitudes from 1960 to around 2000, then increasing at all latitudes over the first half of the 21 st century (21 C), and latitudinal variations in the rate of increase and date of return to historical values. In the second half of the century, ozone is projected to carry on increasing, level off or even decrease depending on the latitude, resulting in variable dates of return to historical values at latitudes where column ozone has declined below those levels. Separation into partial column above and below 20 hPa reveals that these latitudinal differences are almost completely due to differences in the lower stratosphere. At all latitudes, upper stratospheric ozone increases throughout the 21 C and returns to 1960 levels before the end of the century, although there is a spread among the models in dates that ozone returns to historical values. Using multiple linear regression the upper stratospheric ozone increase comes from almost equal contributions due to decrease in halogens and cooling from increased greenhouse gas concentrations. The evolution of lower stratospheric ozone differs with latitude. In the tropical lower stratosphere an increase in tropical upwelling causes a steady decrease in ozone through the 21C, and total column ozone does not return to 1960 levels in all models. In contrast, lower stratospheric and total column ozone in middle and high latitudes increases during the 21 C and returns to 1960 levels. For all models there is an earlier return for ozone to historical levels in the northern hemisphere. This is thought to be due to interhemispheric differences in transport.

Oman, L.↗

Ion-exchange chromatography separation applied to mineral recycle in closed systems

As part of the controlled ecological life support system (CELSS) program, a study is being made of mineral separation on ion-exchange columns. The purpose of the mineral separation step is to allow minerals to be recycled from the oxidized waste products of plants, man, and animals for hydroponic food production. In the CELSS application, relatively large quantities of minerals in a broad concentration range must be recovered by the desired system, rather than the trace quantities and very low concentrations treated in analytical applications of ion-exchange chromatography. Experiments have been carried out to assess the parameters pertinent to the scale-up of ion-exchange chromatography and to determine feasibility. Preliminary conclusions are that the column scale-up is in a reasonable size range for the CELSS application. The recycling of a suitable eluent, however, remains a major challenge to the suitability of using ion exchange chromatography in closed systems.

Ballou, E.↗

RACORO Continental Boundary Layer Cloud Investigations: 3. Separation of Parameterization Biases in Single-Column Model CAM5 Simulations of Shallow Cumulus

Climatically important low-level clouds are commonly misrepresented in climate models. The FAst-physics System TEstbed and Research (FASTER) Project has constructed case studies from the Atmospheric Radiation Measurement Climate Research Facility's Southern Great Plain site during the RACORO aircraft campaign to facilitate research on model representation of boundary-layer clouds. This paper focuses on using the single-column Community Atmosphere Model version 5 (SCAM5) simulations of a multi-day continental shallow cumulus case to identify specific parameterization causes of low-cloud biases. Consistent model biases among the simulations driven by a set of alternative forcings suggest that uncertainty in the forcing plays only a relatively minor role. In-depth analysis reveals that the model's shallow cumulus convection scheme tends to significantly under-produce clouds during the times when shallow cumuli exist in the observations, while the deep convective and stratiform cloud schemes significantly over-produce low-level clouds throughout the day. The links between model biases and the underlying assumptions of the shallow cumulus scheme are further diagnosed with the aid of large-eddy simulations and aircraft measurements, and by suppressing the triggering of the deep convection scheme. It is found that the weak boundary layer turbulence simulated is directly responsible for the weak cumulus activity and the simulated boundary layer stratiform clouds. Increased vertical and temporal resolutions are shown to lead to stronger boundary layer turbulence and reduction of low-cloud biases.

parameterization↗

Multimodel Assessment of the Factors Driving Stratospheric Ozone Evolution over the 21st Century

The evolution of stratospheric ozone from 1960 to 2100 is examined in simulations from 14 chemistry-climate models, driven by prescribed levels of halogens and greenhouse gases. There is general agreement among the models that total column ozone reached a minimum around year 2000 at all latitudes, projected to be followed by an increase over the first half of the 21st century. In the second half of the 21st century, ozone is projected to continue increasing, level off, or even decrease depending on the latitude. Separation into partial columns above and below 20 hPa reveals that these latitudinal differences are almost completely caused by differences in the model projections of ozone in the lower stratosphere. At all latitudes, upper stratospheric ozone increases throughout the 21st century and is projected to return to 1960 levels well before the end of the century, although there is a spread among models in the dates that ozone returns to specific historical values. We find decreasing halogens and declining upper atmospheric temperatures, driven by increasing greenhouse gases, contribute almost equally to increases in upper stratospheric ozone. In the tropical lower stratosphere, an increase in upwelling causes a steady decrease in ozone through the 21st century, and total column ozone does not return to 1960 levels in most of the models. In contrast, lower stratospheric and total column ozone in middle and high latitudes increases during the 21st century, returning to 1960 levels well before the end of the century in most models.

Oman, L. D.↗

OMI Measurements of Bromine Monoxide and Implications for Missing Sources of Polar Bromine in GEOS-Chem

The OMI satellite instrument provides total column measurements of bromine monoxide (BrO) with daily global coverage. Reactive bromine compounds (Br and BrO) catalytically destroy ozone in both the stratosphere and troposphere. The current emission scheme of brominated source gases in the GEOS-Chem chemical transport model well represents the stratospheric burden of bromine. However, halogen research in GEOS-Chem has largely focused on the influence of halogens on the tropospheric oxidative capacity. In the troposphere, the distribution of brominated compounds is more variable and significant uncertainties remain in the chemical processes governing the sources and sinks of reactive bromine compounds. In this study, we use GEOS-Chem simulated stratospheric columns of BrO to separate the tropospheric signal of BrO from the OMI total column measurements. The resulting tropospheric BrO columns are used to identify seasonal and regional anomalies in tropospheric BrO not currently represented in GEOS-Chem. In particular, periods of elevated tropospheric BrO during polar spring are observable by OMI, and past studies have connected these so-called "bromine explosion" events to near complete removal of surface ozone. Due to significant uncertainties in the springtime polar source of reactive bromine, many global models, including GEOS-Chem, do not simulate these tropospheric ozone depletion events. Consequently, OMI-based tropospheric columns of BrO are useful tool for investigating the impact of bromine explosion events on tropospheric ozone depletion episodes as well as background air quality.

Wales, Pamela↗

Coulometer battery state-of-charge indicator

Mercury-column electrochemical coulometer is a linear ampere-hour integrating device consisting of a sealed glass tube containing two columns of mercury separated by a gap containing an electrolyte. The drive circuit uses operational amplifier techniques to match nonlinear charge-discharge characteristics of an alkaline battery.

Birchenough, A. G.↗

Modified polymers for gas chromatography

Polymeric materials are modified to serve as stationary phase in chromatographic columns used for separation of atmospheric gases. Materials simplify and improve separation of atmospheric gases in terms of time, quantity of material needed, and sharpness of separation.

Woeller, F. H.↗

Hybrid polymer microspheres

Techniques have been successfully tested for bonding polymeric spheres, typically 0.1 micron in diameter, to spheres with diameter up to 100 microns. Hybrids are being developed as improved packing material for ion-exchange columns, filters, and separators.

Rembaum, A.↗

Analysis of volatile metabolites in biological fluids as indicators of prodromal disease condition

The volatile profile cannot be defined as a single class of substances, rather it is a broad spectrum of materials of different polarities characterized by having a boiling-point in the low to medium range (up to approximately 300 C) and the fact that the compounds are suitable for gas chromatography without derivatization. The organic volatile profiles are very complex mixtures of metabolic byproducts, intermediates, and terminal products of enzymatic degradations composed mainly of alcohols, ketones, aldehydes, pyrazines, sulfides, isothiocyanates, pyrroles, and furans. The concentration of organic volatiles in biological fluids covers a wide range with many important components present at trace levels. The complexity of the organic volatile fraction requires the use of capillary columns for their separation.

Zlatkis, A.↗

Measuring Trace Hydrocarbons in Silanes

Technique rapid and uses standard analytical equipment. Silane gas containing traces of hydrocarbons injected into carrier gas of moist nitrogen having about 0.2 percent water vapor. Carrier, water and silane pass through short column packed with powdered sodium hydroxide which combines moisture and silane to form nonvolatile sodium silicate. Carrier gas free of silane but containing nonreactive hydrocarbons, pass to silica-gel column where chromatographic separation takes place. Hydrocarbons measured by FID.

Lesser, L. A.↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Columnar growth of CoSi2 on Si(111), Si(100) and Si(110) by molecular beam epitaxy

Codeposition of silicon and cobalt on heated silicon substrates in ratios several times the silicide stoichiometry is found to result in epitaxial columns of CoSi2 surrounded by a matrix of epitaxial silicon. For (111)-oriented wafers, nearly cylindrical columns are formed, where both columns and surrounding silicon are defect free, as deduced from transmission electron microscopy. Independent control of the column diameter and separation is possible, and diameters of 27-135 nm have been demonstrated.

Fathauer, R. W.↗

OASIS: Organics Analyzer for Sampling Icy Surfaces

Liquid chromatography mass spectrometry (LC-MS) is a well established laboratory technique for detecting and analyzing organic molecules. This approach has been especially fruitful in the analysis of nucleobases, amino acids, and establishing chirol ratios [1 -3]. We are developing OASIS, Organics Analyzer for Sampling Icy Surfaces, for future in situ landed missions to astrochemically important icy bodies, such as asteroids, comets, and icy moons. The OASIS design employs a microfabricated, on-chip analytical column to chromatographically separate liquid ana1ytes using known LC stationary phase chemistries. The elution products are then interfaced through electrospray ionization (ESI) and analyzed by a time-of-flight mass spectrometer (TOF-MS). A particular advantage of this design is its suitability for microgravity environments, such as for a primitive small body.

Getty, S. A.↗

Multi-Pass Quadrupole Mass Analyzer

Analysis of the composition of planetary atmospheres is one of the most important and fundamental measurements in planetary robotic exploration. Quadrupole mass analyzers (QMAs) are the primary tool used to execute these investigations, but reductions in size of these instruments has sacrificed mass resolving power so that the best present-day QMA devices are still large, expensive, and do not deliver performance of laboratory instruments. An ultra-high-resolution QMA was developed to resolve N2 +/CO+ by trapping ions in a linear trap quadrupole filter. Because N2 and CO are resolved, gas chromatography columns used to separate species before analysis are eliminated, greatly simplifying gas analysis instrumentation. For highest performance, the ion trap mode is used. High-resolution (or narrow-band) mass selection is carried out in the central region, but near the DC electrodes at each end, RF/DC field settings are adjusted to allow broadband ion passage. This is to prevent ion loss during ion reflection at each end. Ions are created inside the trap so that low-energy particles are selected by low-voltage settings on the end electrodes. This is beneficial to good mass resolution since low-energy particles traverse many cycles of the RF filtering fields. Through Monte Carlo simulations, it is shown that ions are reflected at each end many tens of times, each time being sent back through the central section of the quadrupole where ultrahigh mass filtering is carried out. An analyzer was produced with electrical length orders of magnitude longer than its physical length. Since the selector fields are sized as in conventional devices, the loss of sensitivity inherent in miniaturizing quadrupole instruments is avoided. The no-loss, multi-pass QMA architecture will improve mass resolution of planetary QMA instruments while reducing demands on the RF electronics for high-voltage/high-frequency production since ion transit time is no longer limited to a single pass. The QMA-based instrument will thus give way to substantial reductions of the mass of flight instruments.

Prestage, John D.↗

Mineral Separation in a CELSS by Ion-exchange Chromatography

Operational parameters pertinent to ion exchange chromatography separation were identified. The experiments were performed with 9 mm diameter ion exchange columns and conventional column accessories. The cation separation beds were packed with AG 50W-X2 strong acid cation exchange resin in H(+) form and 200-400 dry mesh particle size. The stripper beds used in some experiments were packed with AG 1-XB strong base cation exchange resin in OH(-) form and 200-400 dry mesh particle size.

Ballou, E. V.↗

Evaluation of Relative Sensitivity of SAW and Flexural Plate Wave Devices for Atmospheric Sensing

The objective of this project is to evaluate the suitability of the ultrasonic flexural plate wave (FPW) device as the detector in a gas chromatograph (GC). Of particular interest is the detection of nitrous oxide (N2O). From experimental results we conclude analyte detection is achieved through two mechanisms: changes in gas density, and mass loading of the device membrane due to the sorption of gas molecules. Reducing the dead volume of the FPW chamber increased the FPW response. A comparison of the FPW response to that of the surface acoustic wave (SAW) detector provided with the GC (made by MSI, Microsensor Technologies, Inc.), shows that for unseparated N2O in N2, the FPW exhibits a sensitivity that is at least 550 times greater than that of the SAW device. A Porapak Q column was found to separate N2O from its carrier gas, N2 or He. With the Porapak Q column, a coated FPW detected 1 ppm N2O in N2 or He, with a response magnitude of 7 Hz. A coated SAW exhibited a response of 25 Hz to pure N2O. The minimal detectable N2O concentrations of the sensors were not evaluated.

White, Richard M.↗

"Dry-column" chromatography of plant pigments

Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

Woeller, F. H.↗