At least 55 records · Page 3

Multi 'omics comparison reveals metabolome biochemistry, not microbiome composition or gene expression, corresponds to elevated biogeochemical function in the hyporheic zone

Biogeochemical hotspots are pervasive at terrestrial-aquatic interfaces, particularly within groundwater-surface water mixing zones (hyporheic zones), and they are critical to understanding spatiotemporal variation in biogeochemical cycling. Here, we use multi ‘omic comparisons of hotspots to low-activity sediments to gain mechanistic insight into hyporheic zone organic matter processing. We hypothesized that microbiome structure and function, as described by metagenomics and metaproteomics, would distinguish hotspots from low-activity sediments through a shift towards carbohydrate-utilizing metabolic pathways and elucidate discrete mechanisms governing organic matter processing in each location. We also expected these differences to be reflected in the metabolome, whereby hotspot carbon (C) pools and metabolite transformations therein would be enriched in sugar-associated compounds. In contrast to expectations, we found pronounced phenotypic plasticity in the hyporheic zone microbiome that was denoted by similar microbiome structure, functional potential, and expression across sediments with dissimilar metabolic rates. Instead, diverse nitrogenous metabolites and biochemical transformations characterized hotspots. Metabolomes also corresponded more strongly to aerobic metabolism than bulk C content only (explaining 67% vs. 42% of variation), and bulk C did not improve statistical models based on metabolome composition alone. These results point to organic nitrogen as a significant regulatory factor influencing hyporheic zone organic matter processing. Based on our findings, we propose incorporating knowledge of metabolic pathways associated with different chemical fractions of C pools into ecosystem models will enhance prediction accuracy.

Graham, Emily B. (ORCID:0000000246237076)↗

Comparison of equilibrium climate sensitivity estimates from slab ocean, 150-year, and longer simulations

We compare equilibrium climate sensitivity (ECS) estimates from pairs of long (= 800-year) control and abruptly quadrupled CO2 simulations with shorter (150, 300 year) coupled atmosphere-ocean simulations and Slab Ocean Models (SOM). Consistent with previous work, ECS estimates from shorter coupled simulations based on annual averages for years 1-150 underestimate those from SOM (-8% ± 13%) and long (-14% ± 8%) simulations. Analysis of only years 21-150 improved agreement with SOM (-2% ± 14%) and long (-8% ± 10%) estimates. Use of pentadal averages for years 51-150 results in improved agreement with long simulations (-4% ± 11%). While ECS estimates from current generation US models based on SOM and coupled annual averages of years 1-150 range from 2.6°C to 5.3°C, estimates based longer simulations of the same models range from 3.2°C to 7.0°C. Such variations between methods argues for caution in comparison and interpretation of ECS estimates across models.

Dunne, John P.↗

Bremsstrahlung versus Monoenergetic Photon Dose and Photonuclear Stimulation Comparisons at Long Standoff Distances

Energetic photon sources with energies greater than 6 MeV continue to be recognized as viable source for various types of inspection applications, especially those related to nuclear and/or explosive material detection. These energetic photons can be produced as a continuum of energies (i.e., bremsstrahlung) or as a set of one or more discrete photon energies (i.e., monoenergetic). This paper will provide a follow-on extension of the photon dose comparison presented at the 9th International Conference on Applications of Nuclear Techniques (June 2008). Our previous paper showed the comparative advantages and disadvantages of the photon doses provided by these two energetic interrogation sources and highlighted the higher energy advantage of the bremsstrahlung source, especially at long standoff distances (i.e., distance from source to the inspected object). This paper will pursue higher energy photon inspection advantage (up to 100 MeV) by providing dose and stimulated photonuclear interaction predictions in air and for an infinitely dilute interrogated material (used for comparative interaction rate assessments since it excludes material self-shielding) as the interrogation object positioned forward on the inspection beam axis at increasing standoff distances. In addition to the direct energetic photon-induced stimulation, the predictions will identify the importance of secondary downscattered/attenuated source-term effects arising from the photon transport in the intervening air environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct simulation of electron transfer using ring polymer molecular dynamics: Comparison with semiclassical instanton theory and exact quantum methods

The use of ring polymer molecular dynamics (RPMD) for the direct simulation of electron transfer (ET) reaction dynamics is analyzed in the context of Marcus theory, semiclassical instanton theory, and exact quantum dynamics approaches. For both fully atomistic and system-bath representations of condensed-phase ET, we demonstrate that RPMD accurately predicts both ET reaction rates and mechanisms throughout the normal and activationless regimes of the thermodynamic driving force. Analysis of the ensemble of reactive RPMD trajectories reveals the solvent reorganization mechanism for ET that is anticipated in the Marcus rate theory, and the accuracy of the RPMD rate calculation is understood in terms of its exact description of statistical fluctuations and its formal connection to semiclassical instanton theory for deep-tunneling processes. In the inverted regime of the thermodynamic driving force, neither RPMD nor a related formulation of semiclassical instanton theory capture the characteristic turnover in the reaction rate; comparison with exact quantum dynamics simulations reveals that these methods provide inadequate quantization of the real-time electronic-state dynamics in the inverted regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of several classical density functional theories for the adsorption of flexible chain molecules into cylindrical nanopores

Adsorption of flexible oligomers into narrow cylindrical pores has been studied by means of several versions of classical density functional theory (CDFT) and Monte Carlo simulation. The adsorption process is interesting to study due to the competition between the entropic depletion of oligomers from the pores and the wall–oligomer attraction. It is also challenging to describe using current CDFTs, which tend to overestimate the amount of the adsorbed fluid. From a comparison of several different CDFT approaches, we find that this is due to the assumption of ideal or freely jointed chain conformations. Moreover, it is demonstrated that it is impossible to obtain a reasonable description of the adsorption isotherms without taking into account accurate contact values in the distribution functions describing the structure of the reference monomer fluid. At low densities, more accurate result are obtained in comparison with Monte Carlo simulation data when accurate contact values are incorporated into the theory rather than the more commonly used hard-sphere contact value. However, even the CDFT with accurate contact values still overestimates the amount of the adsorbed fluid due to the ideal or freely jointed chain approximation, used for the description of chain conformations in most CDFT approaches. We find that significant improvement can achieved by employing self-consistent field theory, which samples self-avoiding chain conformations and decreases the number of possible chain conformations, and, consequently, the amount of the adsorbed fluid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear gyrokinetic simulations of the I-mode high confinement regime and comparisons with experiment

For the first time, nonlinear gyrokinetic simulations of I-mode plasmas are performed and compared with experiment. I-mode is a high confinement regime, featuring energy confinement similar to H-mode, but without enhanced particle and impurity particle confinement [D. G. Whyte et al., Nucl. Fusion 50, 105005 (2010)]. As a consequence of the separation between heat and particle transport, I-mode exhibits several favorable characteristics compared to H-mode. The nonlinear gyrokinetic code GYRO [J. Candy and R. E. Waltz, J Comput. Phys. 186, 545 (2003)] is used to explore the effects of E × B shear and profile stiffness in I-mode and compare with L-mode. The nonlinear GYRO simulations show that I-mode core ion temperature and electron temperature profiles are more stiff than L-mode core plasmas. Scans of the input E × B shear in GYRO simulations show that E × B shearing of turbulence is a stronger effect in the core of I-mode than L-mode. The nonlinear simulations match the observed reductions in long wavelength density fluctuation levels across the L-I transition but underestimate the reduction of long wavelength electron temperature fluctuation levels. The comparisons between experiment and gyrokinetic simulations for I-mode suggest that increased E × B shearing of turbulence combined with increased profile stiffness are responsible for the reductions in core turbulence observed in the experiment, and that I-mode resembles H-mode plasmas more than L-mode plasmas with regards to marginal stability and temperature profile stiffness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of different numerical treatments for x-ray phase tomography of soft tissue from differential phase projections

X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve the same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.

Pelliccia, Daniele↗

A Comparison of Forecast Error Generators for Modeling Wind and Load Uncertainty

This paper presents four algorithms to generate random forecast error time series, including a truncated-normal distribution model, a state-space based Markov model, a seasonal autoregressive moving average (ARMA) model, and a stochastic-optimization based model. The error time series are used to create real-time (RT), hour-ahead (HA), and day-ahead (DA) wind and load forecast time series that statistically match historically observed forecasting data sets, used for variable generation integration studies. A comparison is made using historical DA load forecast and actual load values to generate new sets of DA forecasts with similar stoical forecast error characteristics. This paper discusses and compares the capabilities of each algorithm to preserve the characteristics of the historical forecast data sets.

Lu, Ning↗

Soils' dirty little secret: Depth–based comparisons can be inadequate for quantifying changes in soil organic carbon and other mineral soil properties

Quantifying changes in soil organic carbon (SOC) stocks and other soil properties is essential for understanding how soils will respond to land management practices and global change. Although they are widely used, comparisons of SOC stocks at fixed depth (FD) intervals are subject to errors when changes in bulk density or soil organic matter occur. The equivalent soil mass (ESM) method has been recommended in lieu of FD for assessing changes in SOC stocks in mineral soils, but ESM remains underutilized for SOC stocks and has rarely been used for other soil properties. In this paper, we draw attention to the limitations of the FD method and demonstrate the advantages of the ESM approach. We provide illustrations to show that the FD approach is susceptible to errors not only for quantifying SOC stocks but also for soil mass-based properties such as SOC mass percent, C:N mass ratio, and δ 13 C. Here we describe the ESM approach and show how it mitigates the FD method limitations. Using bulk density change simulations applied to an empirical dataset from bioenergy cropping systems, we show that the ESM method provides consistently lower errors than FD when quantifying changes in SOC stocks and other soil properties. To simplify the use of ESM, we detail how the method can be integrated into sampling schemes, and we provide an example R computer script that can perform ESM calculations on large datasets. We encourage future studies, whether temporal or comparative, to utilize sampling methods that are amenable to the ESM approach. Overall, we agree with previous recommendations that ESM should be the standard method for evaluating SOC stock changes in mineral soils, but we further suggest that ESM may also be preferred for comparisons of other soil properties including mass percentages, elemental mass ratios, and stable isotope composition.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of the sputter rates of oxide films relative to the sputter rate of SiO{sub 2}

There is a growing interest in knowing the sputter rates for a wide variety of oxides because of their increasing technological importance in many different applications. To support the needs of users of the Environmental Molecular Sciences Laboratory, a national scientific user facility, as well as our research programs, the authors made a series of measurements of the sputter rates from oxide films that have been grown by oxygen plasma-assisted molecular beam epitaxy, pulsed laser deposition, atomic layer deposition, electrochemical oxidation, or sputter deposition. The sputter rates for these oxide films were determined in comparison with those from thermally grown SiO{sub 2}, a common reference material for sputter rate determination. The film thicknesses and densities for most of these oxide films were measured using x-ray reflectivity. These oxide films were mounted in an x-ray photoelectron or Auger electron spectrometer for sputter rate measurements using argon ion sputtering. Although the primary objective of this work was to determine relative sputter rates at a fixed angle, the measurements also examined (i) the angle dependence of the relative sputter rates, (ii) the energy dependence of the relative sputter rates, and (iii) the extent of ion beam induced reduction for some oxides. Oxide films examined include SiO{sub 2}, Al{sub 2}O{sub 3}, CeO{sub 2}, Cr{sub 2}O{sub 3}, Fe{sub 2}O{sub 3}, HfO{sub 2}, In-Sn oxide, Ta{sub 2}O{sub 5}, TiO{sub 2} (anatase, rutile, and amorphous), and ZnO. The authors found that the sputter rates for the oxides can vary up to a factor of 2 (usually lower) from that observed for SiO{sub 2}. The ratios of sputter rates relative to those of SiO{sub 2} appear to be relatively independent of ion beam energy in the range of 1-4 kV and for incident angles <50 deg. As expected, the extent of ion beam induced reduction of the oxides varies with the sputter angle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-211: Comparison of Seven New TrueBeam Linacs with Enhanced Beam Data Conformance Using a Beam Comparison Software Tool

Purpose: To develop an independent software tool to assist in commissioning linacs with enhanced beam conformance, as well as perform ongoing QA for dosimetrically equivalent linacs. Methods: Linac manufacturers offer enhanced beam conformance as an option to allow for clinics to complete commissioning efficiently, as well as implement dosimetrically equivalent linacs. The specification for enhanced conformance includes PDD as well as profiles within 80% FWHM. Recently, we commissioned seven Varian TrueBeam linacs with enhanced beam conformance. We developed a software tool in Visual Basic to allow us to load the reference beam data and compare our beam data during commissioning to evaluate enhanced beam conformance. This tool also allowed us to upload our beam data used for commissioning our dosimetrically equivalent beam models to compare and tweak each of our linac beams to match our modelled data in Varian’s Eclipse TPS. This tool will also be used during annual QA of the linacs to compare our beam data to our baseline data, as required by TG-142. Results: Our software tool was used to check beam conformance for seven TrueBeam linacs that we commissioned in the past six months. Using our tool we found that the factory conformed linacs showed up to 3.82% difference in their beam profile data upon installation. Using our beam comparison tool, we were able to adjust the energy and profiles of our beams to accomplish a better than 1.00% point by point data conformance. Conclusion: The availability of quantitative comparison tools is essential to accept and commission linacs with enhanced beam conformance, as well as to beam match multiple linacs. We further intend to use the same tool to ensure our beam data conforms to the commissioning beam data during our annual QA in keeping with the requirements of TG-142.

43 PARTICLE ACCELERATORS↗

A Comparison of Classical and Aggregation-Based Algebraic Multigrid Preconditioners for High-Fidelity Simulation of Wind Turbine Incompressible Flows

This paper presents a comparison of parallel strong scaling performance of classical and aggregation algebraic multigrid (AMG) preconditioners in the context of wind turbine simulations. Fluid motion is governed by the incompressible Navier--Stokes equations, discretized in space with control-volume finite elements and in time with an inexact projection scheme using an implicit integrator. A discontinuous-Galerkin sliding-mesh algorithm captures rotor motion. The momentum equations are solved with iterative Krylov methods, preconditioned by symmetric Gauss--Seidel (SGS) in Trilinos and $\ell_1$ SGS in hypre. The mass-continuity equation is solved with GMRES preconditioned by AMG and can account for the majority of simulation time. Reducing this continuity solve time is crucial. Wind turbine simulations present two unique challenges for AMG preconditioned solvers: the computational meshes include strongly anisotropic elements, and mesh motion requires matrix reinitialization and computation of preconditioners at each time step. Detailed timing profiles are presented and analyzed, and best practices are discussed for both classical and aggregation-based AMG. Results are presented for simulations of two different wind turbines with up to 6 billion grid points on two different computer architectures. For moving mesh problems that require linear-system reinitialization, the well-established strategy of amortizing preconditioner setup costs over a large number of time steps to reduce the solve time is no longer valid. Instead, results show that faster time to solution is achieved by reducing preconditioner setup costs at the expense of linear-system solve costs. Standard smoothed aggregation with Chebyshev relaxation was found to perform poorly when compared with classical AMG in terms of solve time and robustness. However, plain aggregation was comparable to classical AMG.

97 MATHEMATICS AND COMPUTING↗

Cross-Section Comparison for Pu-238 Production in the Advanced Test Reactor at Idaho National Laboratory

Qualification of Advanced Test Reactor (ATR) positions for Pu-238 production has been ongoing at Idaho National Laboratory (INL). The ATR qualifications have stretched over multiple years during which new techniques have been developed and made available for ATR experiment neutronic analysis. As part of the transition to newer codes, new cross-section libraries have been evaluated for use in the Pu-238 production experiment analysis. A comparative study was done using the MCNP ORGIEN Activation Analysis (MOAA) tool between ENDF/B-VII.0 and ENDF/B-VIII.0 cross sections to capture the impact of the change in cross-sections on the analysis needed to qualify Pu-238 production targets. All comparisons were done assuming the ATR GEN-I targets were located in the south flux trap of the ATR. Finally, an overview of how this qualification and potential irradiation fits into Pu-238 is discussed.