Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparisons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimization and Comparison of Modern Offshore Wind Turbine Generators Using GeneratorSE 2.0

As the offshore wind industry keeps growing at a rapid pace, developers are bracing themselves for a huge demand in critical rare earth metals which will threaten an already vulnerable supply chain. The wind energy industry is addressing this problem by investing in modern generator technologies that employ magnets with reduced rare earth content and high-field magnets enabled by rare-earth-free superconductors. In this paper we introduce the National Renewable Energy Laboratory's newly advanced GeneratorSE 2.0, which is a design and optimization tool that was developed to investigate the feasibility of such modern generators. Two direct-drive generator topologies with different magnet materials and mounting arrangements are investigated: an outer-rotor, V-shaped interior permanent magnet generator, and an inner-rotor normally conducting armature, paired with a low-temperature superconducting field with race-track coils. These technologies were evaluated for a range of power ratings between 15 and 25 MW, which represent the next generation of offshore wind turbines for both fixed-bottom and floating applications. The analyses indicate a new trend favoring the low-temperature superconducting technology for the direct-drive system.

direct-drive generators↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

A Comparison of Radiation-Induced and High-Field Electrically Stress-Induced Interface Defects in Si/SiO 2 MOSFETs via Electrically Detected Magnetic Resonance

Here, we utilize electrically detected magnetic resonance (EDMR) measurements to compare high-field stressed, and gamma irradiated Si/SiO 2 metal–oxide–silicon (MOS) structures. We utilize spin-dependent recombination (SDR) EDMR detected using the Fitzgerald and Grove dc I-V approach to compare the effects of high-field electrical stressing and gamma irradiation on defect formation at and near the Si/SiO 2 interface. As anticipated, both greatly increase the concentration of P b centers (silicon dangling bonds at the interface) densities. The irradiation also generated a significant increase in the dc I-V EDMR response of E' centers (oxygen vacancies in the SiO 2 films), whereas the generation of an E' EDMR response in high-field stressing is much weaker than in the gamma irradiation case. These results likely suggest a difference in their physical distribution resulting from radiation damage and high electric field stressing.

42 ENGINEERING↗

Comparison of Real-Time Pressure Rail Selection Algorithms for the Hybrid Hydraulic Electric Architecture: Case Study on a Track Loader

Abstract The hybrid hydraulic electric architecture (HHEA) seeks to combine the high power/torque/force density of hydraulics with the efficiency of electric machines. A set of common pressure rails is used to provide a majority of the power and this power is modulated by small electric machines to provide precise control for the operator. The HHEA has been studied in previous work using off-line dynamic programming optimization to determine energy efficient pressure rail selections, but this approach requires drive cycle information apriori. A Lagrange multiplier method has also been investigated where a set of gains (Lagrange multipliers) are optimized off-line with the idea the these gains, once determined, could be used for real-time operation. In this work, three new real-time pressure rail selection algorithms that do not require future drive cycle information are investigated; greedy, torque minimizing, and thresholding. The greedy control is found to only use 1% more energy than the globally optimal dynamic programming solution; but a model of energy loss is required.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Entrainment–Mixing Characteristics through Direct Comparisons of Drop Size Distributions Using In Situ Observations from ACE-ENA

Abstract Constraining the impacts of entrainment and associated mixing (i.e., entrainment–mixing) on cloud properties continues to be difficult, partly due to observational uncertainties as well as a lacking consensus of which methodologies for diagnosing entrainment–mixing are most appropriate. This study introduces a novel method to evaluate the presence and degree of inhomogeneous and homogeneous mixing using ∼100 h of in situ observations from a research aircraft over the northeastern Atlantic. Specifically, drop size distributions are compared between regions containing negligible and significant entrainment for select flight legs, making a direct characterization of the degree of homogeneous and inhomogeneous mixing possible. A measure of drop concentration variance is used as a proxy variable to diagnose entrainment–mixing. Results correspond well with entrainment–mixing metrics, showing lower Damköhler numbers where drop size distributions shift toward smaller drop sizes (i.e., inhomogeneous mixing) and greater transition length scales where drop size distributions do not (i.e., homogeneous mixing). Inhomogeneous mixing occurs in most samples from Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA) (regardless of homogeneous mixing frequencies increasing with increasing spatial resolution from ∼100 to ∼10 m) and is associated with decreased drop size relative dispersion and both greater aerosol and drop concentrations compared with homogeneous mixing. Precipitating clouds have a greater frequency of homogeneous mixing compared with nonprecipitating clouds. The proposed methodology is similarly applied to in situ observations of southeast Pacific stratocumulus, shallow convective clouds over central Oklahoma and low-level clouds over the Southern Ocean. All four locations are primarily dominated by inhomogeneous mixing with minimal variability among each region.

Clouds↗

Comparison of CERES SYN1deg Radiative Fluxes with Those Derived from Observations at the ARM ENA Site

Profiles of radiative fluxes simulated from thermodynamic and cloud observations made at the Atmospheric Radiation Measurement (ARM) eastern North Atlantic (ENA) site for a 6-yr period are termed as ENARad. ENARad radiative fluxes are compared to those from the Clouds and the Earth’s Radiant Energy System (CERES) 1°-resolution synoptic product (SYN1deg)-simulated radiative flux profiles as well as the CERES instrument observed top-of-the-atmosphere (TOA) fluxes and ground site broadband radiometer measurements. Monthly average differences between ENARad and surface radiometer reported fluxes and differences between ENARad, SYN1deg, and observed fluxes at TOA were statistically insignificant. SYN1deg significantly overestimated surface downwelling shortwave flux by 12 ± 52 W m −2 and surface downwelling longwave flux by 5 ± 20 W m −2 on monthly time scales. Such overestimations were traced to a moister and warmer subcloud layer, a drier cloud layer, and a moister and colder above-cloud-free troposphere in the ancillary thermodynamic and cloud properties used by SYN1deg than observed. Similarly, low-cloud coverage, boundaries, and liquid water paths utilized by SYN1deg were also significantly higher than observed. Intramodel differences in the hourly values of shortwave fluxes exceeded 100 W m−2 at the TOA and the surface. These differences were also due to inaccuracies in the representation of low-cloud properties within the SYN1deg product relative to those determined by ENA ARM instrumentation and used as ENARad ancillary data. Results presented are relevant to investigations employing the CERES SYN1deg data product, studies that estimate radiative fluxes from surface-based or satellite-borne observations, and comparative analyses of radiative fluxes derived using different methodological approaches.

54 ENVIRONMENTAL SCIENCES↗

Computation and Comparison of the Stable Northeastern US Marine Boundary Layer

In this work we investigate the behavior of stable marine boundary layers located near the coast of the Northeastern United States. Using the ExaWind large eddy simulation (LES) codes, three stable atmospheric conditions were chosen to match the Cape Wind measurements of Archer et al. with wind speeds of 5 m/s, 10 m/s, and 15 m/s at the 20 m measurement height. The behavior of the stable boundary layers, including mean flow quantities and turbulent statistics, are examined and compared to previous computations of the neutral and unstable offshore boundary layer at the same location. This study also examines the domain and mesh requirements necessary to capture the turbulent scales for the stable offshore boundary layers. Finally, we compare solutions computed using both Nalu-Wind and AMR-Wind solvers, and compare their predicted solutions and performance in this study.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

TRT Compton Scattering Data: Comparisons between LLNL and LANL: Pointwise

This memo is one of a pair of reports comparing Compton scattering data in the context of thermal radiation transport (TRT). This document focuses on Pointwise (PW) data while the other report focuses on Multigroup (MG) data. These complementary analyses, via PW comparisons, show if the same physics are used and if fundamental bugs are present, and, via MG comparisons, quantify macroscopic Compton effects such as mean amplification factors. No averaging of Compton data over photon energy is done for the PW comparisons, while lab-dependent numerical resolution choices become relevant for the MG comparisons. This document plots and quantifies differences in PW Compton scattering data between LANL and LLNL for four disparate temperatures on a logarithmically-spaced energy grid. PW comparisons means we use the received LLNL data as-is, without any averaging or integration over energy. In addition to LANL-to-LLNL comparisons, we investigate the impact of numerical choices on LANL PW data. For the purposes of this comparison, we neglect induced scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Comparison of the Environmental Effects of Open-Loop and Closed-Loop Pumped Storage Hydropower

Pumped storage hydropower (PSH) capabilities are generally characterized as either open-loop or closed-loop. The U.S. Department of Energy (DOE) defines open-loop PSH as “continuously connected to a naturally flowing water feature,” and closed-loop PSH as “not continuously connected to a naturally flowing water feature.” All the PSH projects constructed in the United States to date are open-loop, so the potential environmental effects of closed-loop systems are not as well documented as the effects of open-loop systems. To address this knowledge gap, the DOE Water Power Technologies Office, under its HydroWIRES Initiative, has prepared this report to: (1) compare the potential environmental effects of open-loop PSH projects with those of closed-loop PSH projects; (2) describe how these effects are being avoided, minimized, or mitigated at existing projects in other countries and proposed projects in the United States; and (3) discuss the relative significance of the environmental issues. The report begins with a brief introduction on the current status of PSH development in the United States. Next, the report describes the current Federal Energy Regulatory Commission (FERC) hydropower licensing process, emphasizing some recent regulatory changes that affect closed-loop PSH development. The report then provides a summary comparison of the environmental effects of constructing and operating open-loop and closed-loop PSH systems and discusses the relative significance of those issues. This comparison and discussion are based on the results of a literature review and a review of FERC licensing records. The literature review includes journal articles, technical reports, and presentations on the environmental effects of PSH systems. It includes literature from the United States as well as countries where closed-loop PSH projects have been constructed. The FERC records review examines the FERC licensing record (e.g., National Environmental Policy Act documents and license orders) to identify the environmental effects anticipated and mitigation measures proposed for six of the closed-loop PSH projects currently licensed or permitted in the United States. For comparison, the FERC records review also discusses the environmental effects and mitigation measures for four open-loop PSH projects proposed or currently operating in the United States. The comparison of effects between open-loop and closed-loop projects is relative; that is, it characterizes the impacts of each project type as generally lower or higher than another project type. The comparison reflects general trends among project types because there are sometimes exceptions to the examples cited. The comparison is based on both spatial (location) and temporal (duration) factors and reflects both the severity and likelihood of effects. The report concludes that the environmental effects of closed-loop PSH projects are generally lower (i.e., more localized and of shorter duration) than those of open-loop PSH projects because they are located “off-stream,” minimizing aquatic and terrestrial impacts, and often have greater siting flexibility than open-loop PSH projects. For certain closed-loop project designs, however, impacts to groundwater may be higher relative to open-loop projects and should be considered in any environmental review.

13 HYDRO ENERGY↗

TRT Compton Scattering Data: Comparisons between LLNL and LANL: Multigroup

This memo is one of a pair of reports comparing Compton scattering data in the context of thermal radiation transport (TRT). This document focuses on Multigroup (MG) data while the other report focuses on Pointwise (PW) data. These complementary analyses, via PW comparisons, show if the same physics are used and if fundamental bugs are present, and, via MG comparisons, quantify macroscopic Compton effects such as mean amplification factors. No averaging of Compton data over photon energy is done for the PW comparisons, while lab-dependent numerical resolution choices become relevant for the MG comparisons. For this MG-comparison report, we make and document the numerical assumptions we use to convert LLNL PW data into MG data. This document plots and quantifies differences in Compton scattering data between MG LANL and LLNL for four disparate temperatures on a logarithmically-spaced photon-energy grid. In addition to LANL and LLNL data, we add a third and fourth independent vote from data generated by Brooks Kinch (LANL postdoc). For the purposes of these comparisons, we neglect induced scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A study of examiner accuracy in cartridge case comparisons. Part 1: Examiner error rates

This report describes a study undertaken to estimate examiner (not laboratory) error rates for false Identifications and false Eliminations when comparing an unknown to a collection of three known cartridge cases. Volunteer active examiners with Association of Firearm and Toolmark Examiners (AFTE) membership or working in laboratories that participate in the Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. In addition to determining whether the known and questioned cartridge cases were fired with the same handgun, examiners were also asked to assess how many of the three knowns in each set were suitable for comparison, providing an estimated rate of how often each firearm used in the study produces useable, quality marks. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false Eliminations was estimated as 0.367% from comparisons known to be from the same firearm but reported as Eliminations. The overall rate of false Identifications was estimated as 1.01% from comparisons known to be from different firearms but reported as Identifications. The rates are not uniform across the sample population with a few examiners providing most of the false Identification responses. Rates of poor-quality mark production varied across the 25 sample handguns; those rates were 2.3% (±1.4%). Both false Elimination and false Identification rates are comparable to or lower than the rate of production of poor-quality marks by the firearms used in this study.

99 GENERAL AND MISCELLANEOUS↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

Development of a Comparison Framework for Evaluating Environmental Contours of Extreme Sea States

Environmental contours of extreme sea states are often utilized for the purposes of reliability-based offshore design. Many methods have been proposed to estimate environmental contours of extreme sea states, including, but not limited to, the traditional inverse first-order reliability method (I-FORM) and subsequent modifications, copula methods, and Monte Carlo methods. These methods differ in terms of both the methodology selected for defining the joint distribution of sea state parameters and in the method used to construct the environmental contour from the joint distribution. It is often difficult to compare the results of proposed methods to determine which method should be used for a particular application or geographical region. The comparison of the predictions from various contour methods at a single site and across many sites is important to making environmental contours of extreme sea states useful in practice. The goal of this paper is to develop a comparison framework for evaluating methods for developing environmental contours of extreme sea states. This paper develops generalized metrics for comparing the performance of contour methods to one another across a collection of study sites, and applies these metrics and methods to develop conclusions about trends in the wave resource across geographic locations, as demonstrated for a pilot dataset. These proposed metrics and methods are intended to judge the environmental contours themselves relative to other contour methods, and are thus agnostic to a specific device, structure, or field of application. The metrics developed and applied in this paper include measures of predictive accuracy, physical validity, and aggregated temporal performance that can be used to both assess contour methods and provide recommendations for the use of certain methods in various geographical regions. The application and aggregation of the metrics proposed in this paper outline a comparison framework for environmental contour methods that can be applied to support design analysis workflows for offshore structures. This comparison framework could be extended in future work to include additional metrics of interest, potentially including those to address issues pertinent to a specific application area or analysis discipline, such as metrics related to structural response across contour methods or additional physics-based metrics based on wave dynamics.

54 ENVIRONMENTAL SCIENCES↗

Direct comparison between experiments and dislocation dynamics simulations of high rate deformation of single crystal copper

A long standing challenge in computational materials science is to establish a quantitative connection between the macroscopic properties of plastic deformation with the microscopic mechanisms of dislocations in crystalline materials. Although the discrete dislocation dynamics (DDD) simulation method has been developed for several decades with the goal of addressing this challenge, a one-to-one comparison between the DDD predictions on single crystal stress–strain curves and experimental measurements under identical conditions has not been possible to date. Such a comparison is an essential step towards establishing a dislocation-physics based theory of plasticity and a multiscale framework of the plastic behaviors of crystalline materials. Here we provide direct comparisons between the stress–strain curves of Cu single crystals under high strain rate loading in the [0 0 1] and [0 1 1] directions obtained from miniaturized desktop Kolsky bar experiments and those from DDD simulations under identical loading conditions. With an appropriate set of parameters, DDD simulations can produce stress–strain curves that are in reasonable agreement with the experimental results. However, the dislocation mobility values needed to achieve this agreement are an order of magnitude lower than expected based on previous measurements and atomistic simulations. We hypothesize that this discrepancy could be caused by drag forces from jogs and point defects produced during the plastic deformation. Cross-slip of screw dislocations is also found to be necessary to capture the experimental stress–strain behavior, especially for the [0 1 1] loading direction. Finally, this work provides an example of how direct comparisons between DDD simulations and experimental measurements can provide new insight into the fundamental mechanisms of plastic deformation.

36 MATERIALS SCIENCE↗

A study of examiner accuracy in cartridge case comparisons. Part 2: Examiner use of the AFTE range of conclusions

Here, this report describes an analysis of how examiners used the Association of Firearm and Toolmark Examiners (AFTE) Range of Conclusions in a controlled study undertaken to estimate examiner error rates in comparing cartridge cases. Results of the error rate analysis are reported in [1]; this paper focuses on a broader analysis of how the entire collection of classification categories, especially those in the Inconclusive range, were used by the participating examiners. Volunteer active examiners with AFTE membership or working in laboratories that participate in Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false-negatives was estimated as 0.367 % from comparisons known to be from the same firearm but reported as eliminations. The overall rate of false-positives was estimated as 1.01 % from comparisons known to be from different firearms but reported as identifications. In the case of true different-source examinations, it is clear that the three Inconclusive categories and the Elimination category are not used consistently by all examiners. We identify five different apparent patterns of use of the AFTE Range of Conclusions scale, and discuss possible reasons for and implications of these differences.

99 GENERAL AND MISCELLANEOUS↗

Improving magnitude and phase comparison metrics for frequency response functions using cross-correlation and log-frequency shifting

This paper provides a new method for matching dominant features of Frequency Response Functions (FRFs). In particular, this paper proposes a slicing and shifting method where the key features (in this case, resonant amplitudes) of a baseline FRF are compared with a similar FRF using cross-correlation and a Log-Frequency Shift (LFS). Here, the goal is to provide an alternative to classic point-to-point methods for FRF comparison and instead to match the dominant features of two FRFs in a way similar to visual inspection. This enables existing FRF comparison metrics to then be applied with greater fidelity. Additionally, this paper introduces the Phase Similarity Metric (PSM) for comparing phases of two FRFs and illustrates the improvement of using LFS for phase comparisons as well. This paper uses a cantilever beam experiment in multiple configurations to provide a benchmark case for FRF comparison improvements.

42 ENGINEERING↗

Legacy surface change analyses of the 1993 Rock Valley earthquake sequence for direct comparison to planned NA-22 underground conventional high-explosive experiments (Source Physics Experiment 3 (SPE3) - RV/DC Task 1.3 FY22 Final Report)

Recent work under two previous phases of the NNSA NA-22 Source Physics Experiment (SPE) have shown that underground chemical high-explosive experiments can produce detectable surface changes that differ in spatial extent and vertical magnitude depending on the geologic media at the site (Schultz-Fellenz et al., 2018; 2020; Crawford et al., 2021). Neither of these two prior phases of SPE identified natural earthquake-related surface effects in the same region that occurred at a similar depth as the explosive experiments for direct comparison. While earthquakes can also produce surface changes that are detectable using remote sensing data analyses, it is expected that the pattern and spatial extent of surface changes would vary between earthquakes and explosions. However, no direct-observed surface-change signature comparison between earthquakes and explosions has ever been performed. The SPE Phase 3 Rock Valley/Direct Comparison (RV/DC) program presents a unique opportunity to investigate and characterize co-occurrence of both earthquakes and explosions. In this project, we worked to address five tasks in a workflow, as follows: 1. Identify and obtain existing high-resolution legacy satellite and aerial imagery as close in time before and after the 1993 Rock Valley earthquake sequence to temporally constrain the analyses. 2. Transform these pre-earthquake and post-earthquake datasets into digital elevation models (DEMs) using geospatial analysis software packages (e.g., ArcGIS, Agisoft Metashape, and Google Earth Engine). 3. Perform DEM differencing analyses to assess and quantify earthquake-related changes from the 1993 sequence, and develop map products that visualize these analyses. 4. Use the analyses from (3) to: (a) assess spatial distribution and magnitude of surface changes due to the 1993 Rock Valley earthquake sequence, and (b) determine parameters of forthcoming, planned explosion-related surface change data collection from sensors mounted on unmanned aerial vehicles (UAVs) (e.g., spatial extent of collection, design and density of survey control, sensors to deploy, forward speed and line spacing of UAV flight lines, flight altitude). 5. Develop a summary report on the analyses, including how the analyses define parameters and identify focus areas for any future surface change analytical field campaigns related to the explosive experiment. Analyzing these legacy data and identifying whether they can detect any surface changes related to the earthquake sequence facilitates opportunities for direct signature comparison of surface change from explosions at one location, which has never previously been performed. Comparing the surface change signatures from a co-located and depth-equivalent earthquake and an explosion could help to advance remote sensing event discrimination techniques. This report summarizes the work completed toward this ambitious goal.

42 ENGINEERING↗