Search NASA⌕ Search

SEARCH · Search NASA

Results for “compositional analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rice ROSE Compositional Analysis and Transformation Framework (R2CAT)

he Rice ROSE Compositional Analysis and Transformation Framework (R2CAT) synthesizes a series of program analysis and transformation components into a unified framework, and provides an interface to facilitate exchanging information among those components.

97 MATHEMATICS AND COMPUTING↗

Household waste compositional analysis variation from insular communities in the framework of waste prevention strategy plans

Highlights: • Waste framework directive has set clear waste prevention procedures. • Household Compositional analysis. • Waste management plans. • Zero waste approach. • Waste generation. - Abstract: Waste management planning requires reliable data regarding waste generation, affecting factors on waste generation and forecasts of waste quantities based on facts. In order to decrease the environmental impacts of waste management the choice of prevention plan as well as the treatment method must be based on the features of the waste that are produced in a specific area. Factors such as culture, economic development, climate, and energy sources have an impact on waste composition; composition influences the need of collecting waste more or less frequently of waste collection and disposition. The research question was to discover the main barriers concerning the compositional analysis in Insular Communities under warm climate conditions and the findings from this study enabled the main contents of a waste management plan to be established. These included advice to residents on waste minimisation, liaison with stakeholders and the expansion of kerbside recycling schemes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Base Case

In order to meet the requirements of U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, a composite analysis (CA) must be completed for the Central Plateau at the Hanford Site. The updated Hanford Site CA requires estimates of fate and transport of radionuclides in the groundwater from multiple sources within and downgradient of the Central Plateau. Numerical simulations using the MT3D-MST computer code were conducted to evaluate the fate and transport of existing distributions of 16 radionuclides as identified in CP-62184, Hanford Site Composite Analysis: Radionuclide Selection for Groundwater Pathway Evaluation: tritium (H-3), carbon-14 (C-14), chloride- 36 (Cl-36), strontium-90 (Sr-90), technetium-99 (Tc-99), rhenium-187 (Re-187), radium-226 (Ra-226), thorium-230 (Th-230), uranium-232 (U-232), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), neptunium-237 (Np-237), and uranium-238 (U- 238). This document details the application of the P2R Model version 8.3 to predict the fate and transport of contaminants in groundwater on the Central Plateau for the 10,052 year simulation to support the CA. The simulation of fate and transport of contaminants reported in this environmental calculation file (ECF) will support dose predictions as part of the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis Special Analysis: P2R Model Predictive Contaminant Transport Simulations - Sensitivity Case

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of predictive fate and transport simulations using the Plateau-to-River (P2R) model. This ECF supports the reevaluation of the representativeness of solid-waste radionuclide inventory and release rate from three solid waste sites included in the recently completed Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020)). Specifically, this ECF supports the reevaluation of the representativeness of the base case inventory and radionuclide waste release rates from three solid waste sites (i.e., 218-E-12B, 218-W-3A and 218-W-3AE) and two radionuclides (carbon-14 [C-14] and technetium [Tc-99]). These three waste sites and two radionuclides were identified as being the most significant contributors to groundwater contamination and dose in the CA at time periods after the compliance period. The release rates and footprints of the releases from the vadose zone are implemented in the fate and transport modeling utilizing the HSS package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Null-Space Model Carlo Flow Model Set

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater pathway based on the null space Monte Carlo (NSMC) groundwater concentrations as a part an uncertainty analysis for the updated Hanford Site Composite Analysis (CA). The Plateau-to River (P2R) Groundwater Model (CP-57037, Model Package Report: Plateau to River Groundwater Model Version 8.3) is the CA base case that simulates the fate and transport of radiological contaminants within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. An NSMC analysis was performed to identify and quantify the potential uncertainties associated with the P2R Model. The result of the NSMC analysis is a set of flow and transport simulations that provide an estimated range of possible outcomes that are used to quantify the uncertainty associated with the simulated base case concentrations.

54 ENVIRONMENTAL SCIENCES↗

Quantitative compositional analysis and strain study of InAs quantum wires with InGaAlAs barrier layers

Quantitative compositional analysis of InAs quantum wires deposited between In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layers grown on InP substrates was performed by electron energy loss spectrometry and energy dispersive x-ray spectrometry. An indium-rich region in the center of the wire, with decreasing indium concentration toward the interface with the barrier layers, was observed from indium concentration maps for individual quantum wires. 'Stripelike' contrast modulation was observed in diffraction contrast transmission electron microscope images of the In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layer immediately above the quantum wires. The contrast originated from indium compositional modulations in the upper barrier layer as confirmed by electron energy loss spectrometry and the modulation is attributed to the presence of an inhomogeneous elastic strain field generated by the buried quantum wires. These results suggest that quantitative analysis of the composition and strain distributions at very high spatial resolution provides insights necessary to further model the physical properties and to understand the growth of these nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Annual Performance Assessment and Composite Analysis Review for the ICDF Landfill FY 2008

This report addresses low-level waste disposal operations at the Idaho Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Disposal Facility (ICDF) landfill from the start of operations in Fiscal Year 2003 through Fiscal Year 2008. The ICDF was authorized in the Operable Unit 3-13 Record of Decision for disposal of waste from the Idaho National Laboratory Site CERCLA environmental restoration activities. The ICDF has been operating since 2003 in compliance with the CERCLA requirements and the waste acceptance criteria developed in the CERCLA process. In developing the Operable Unit 3-13 Record of Decision, U.S. Department of Energy Order (DOE) 435.1, 'Radioactive Waste Management', was identified as a 'to be considered' requirement for the ICDF. The annual review requirement under DOE Order 435.1 was determined to be an administrative requirement and, therefore, annual reviews were not prepared on an annual basis. However, the landfill has been operating for 5 years and, since the waste forms and inventories disposed of have changed from what was originally envisioned for the ICDF landfill, the ICDF project team has decided that this annual review is necessary to document the changes and provide a basis for any updates in analyses that may be necessary to continue to meet the substantive requirements of DOE Order 435.1. For facilities regulated under DOE Order 435.1-1, U.S. DOE Manual 435.1-1, 'Radioactive Waste Management', IV.P.(4)(c) stipulates that annual summaries of low-level waste disposal operations shall be prepared with respect to the conclusions and recommendations of the performance assessment and composite analysis. Important factors considered in this review include facility operations, waste receipts, and results from monitoring and research and development programs. There have been no significant changes in operations at the landfill in respect to the disposal geometry, the verification of waste characteristics, and the tracking of inventories against total limits that would affect the results and conclusions of the performance assessment. Waste receipts to date and projected waste receipts through Fiscal Year 2012 are both greater than the inventory assessed in the performance assessment and composite analysis. The waste forms disposed of to the landfill are different from the waste form (compacted soil) assessed in the performance assessment. The leak detection system and groundwater monitoring results indicate the landfill has not leaked. The results of the performance assessment/composite analysis are valid (i.e., there is still a reasonable expectation of meeting performance objectives) but the new information indicates less conservatism in the results than previously believed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of heat input on dissimilar welds of ultra high strength steel and duplex stainless steel: Microstructural and compositional analysis

The effect of heat input on the microstructure and compositional heterogeneity of welds of direct-quenched ultra high strength steel (Optim 960 QC) and duplex stainless steel (UNS S32205) was studied. The dissimilar welds were made using GMAW with a fully austenitic filler wire. In addition to grain coarsening in the heat affected zone (HAZ) of the ferritic side, it was found that an increase in heat input correlatively increased the proportional volume of bainitic to martensitic phases. Coarse ferritic grains were observed in the duplex HAZ. Higher heat input, however, had a beneficial effect on the nucleation of austenite in the HAZ. Heat input had a regulatory effect on grain growth within the austenitic weld and more favorable equiaxed austenite was obtained with higher heat input. On the ferritic side of the welds, macrosegregation in the form of a martensitic intermediate zone was observed for all the cooling rates studied. However, on the duplex side, macrosegregation in the fusion boundary was only noticed with higher cooling rates. Microstructural observations and compositional analysis suggest that higher heat input could be beneficial for the structural integrity of the weld despite higher heat input increasing the extent of adverse coarse grains in the HAZ, especially on the ferritic side. - Highlights: •The effect of heat input on dissimilar welds of UHSS and DSS was studied. •Transmutation of the microstructure was discussed in detail. •The influence of heat input on compositional heterogeneity of welds was described. •Higher heat input enhanced bainitic transformation on the ferritic side. •Macrosegregation was affected by the amount of heat input on the DSS side.

36 MATERIALS SCIENCE↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau-to-River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. Figure 1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the composite analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3 documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau to River Groundwater Model (P2R Model) is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by CH2M HILL Plateau Remediation Company at the Hanford Site in Washington State. Figure 1-1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the Composite Analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3, documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation is to describe the application of the hydraulic property fields and recharge parameters documented in ECF-HANFORD-20-0027, Null Space Monte Carlo Evaluation of the Plateau to River Model, to the CA flow and fate and transport simulation results to quantify the uncertainty in the simulated results due to input parameter selection. Use of numerical groundwater models is always accompanied with uncertainty in the results produced by a model because models are approximations of reality. Thus, by definition, models lack the detail to fully represent observed behavior. Use of numerical techniques, such as a NSMC analysis, can help in identifying and quantifying the potential uncertainties associated with a numerical model such as the P2R Model. The result of NSCM analysis is a set of F&T simulations that provide an estimate of the range of possible outcomes that are used to quantify the uncertainty in simulated concentrations produced using the base case simulations. The simulated concentrations from all simulations will support calculation of the uncertainty of the total dose calculated in a separate calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis Data Package: Exposure Scenarios and Radionuclide Specific Dose Conversion Factors

This data package summarizes the exposure assumptions, equations, and methods used to calculate radionuclide-specific unit dose factors and the radiological doses for both groundwater and atmospheric pathways as a part of the updated Hanford Site Composite Analysis (CA). An All Pathways Representative Person exposure scenario is considered to evaluate exposure via both groundwater and atmospheric transport pathways. The radiological dose assessments for both groundwater and atmospheric pathways are included in the performance assessments (PAs) for various Waste Management Areas at the Hanford Site. This data package calculates exposure route-specific and total unit dose factors for CA-specific radionuclides of concern based on the exposure assumptions used in the CA and PAs. This data package also presents the results and comparison of the radionuclide-specific unit dose factors based on the exposure assumptions used in the revised Hanford Site Composite Analysis and Hanford Site performance assessments for low-level waste disposal facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Composite Analysis for Low Level Waste Disposal in the Central Plateau of the Hanford Site (FY2019 Annual Status Report)

In accordance with DOE M 435.1-1 requirements and as implemented by DOE/RL-2000-29, the U.S. Department of Energy (DOE), Richland Operations Office has prepared this annual summary for fiscal year (FY) 2019. Originally reported in PNNL-11800 and PNNL-11800, Addendum 1, the Hanford Site Composite Analysis was approved through issuance of a 2002 memorandum. As required by DOE/RL-2000-29, an annual evaluation of new information and data developed by a number of onsite programs was completed. The reporting period for this annual evaluation is FY 2019 (October 1, 2018, through September 30, 2019). The information provided in this evaluation includes activities performed in FY 2019 that are considered pertinent to the Hanford Site Composite Analysis - information that could change source terms considered, and monitoring, research, and development results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis: Radionuclide Selection for Groundwater Pathway Evaluation.

The updated Hanford Site Composite Analysis (CA) will provide an all-pathways dose projection to a hypothetical future member of the public from all planned low-level radioactive waste disposal facilities and potential contributions from all other projected end-state sources of radioactive material left at the Hanford Site following site closure. Its primary purpose is to support the decision-making process of the U.S. Department of Energy (DOE) under DOE O 435.1-1, Radioactive Waste Management, related to managing low-level waste disposal facilities at the Hanford Site. A key aspect of conducting a CA is selecting the radionuclides to be included in the quantitative analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SRS Composite Analysis Monitoring Plan (FY2019 Model Validation)

Using a projected end-state date of 2065 (SRNS 2015b), the Savannah River Site (SRS) Composite Analysis (CA) modeling for each facility and waste site began on the inventory year assigned to it so that source depletion and radionuclide transport out of the system could be appropriately captured. Some SRS waste sites that have already achieved their end states (i.e. end-state inventories and end-state configuration) are currently contributing to the potential off-site public dose through source release, groundwater transport, discharge to on-site surface streams, and stream transport to the CA point of assessments (POAs). The inventory year assigned to these waste sites is 2002 or before. This means that SRS CA results from 2002 and beyond are a reasonable representation for these waste sites that have already achieved their end states and are currently contributing to the potential off-site public dose. The SRS Annual Environmental Report (AER) monitoring can differentiate and separate liquid pathway data allowing the data representing only waste sites at their end state to be produced. Because the SRS CA has projected reasonable end-state impacts from 2002 and beyond, and the AER monitoring can differentiate and separate operating and end-state contributions to annual liquid pathway release, an opportunity exists to use the AER monitoring data to validate the SRS CA model. The CA model validation program uses a graded and systematic approach for taking corrective action, starting with an SRS established administrative dose limit of 15 mrem/yr, below which no action is required. Based on the location of the 2010 SRS CA POAs, the only potential exposure pathway for the public is through surface water. The completion of the FY2019 CA model validation indicates that the SRS CA projected dose, while generally conservative, provides a reasonable representation of the maximum annual doses. These doses are well below the administrative limit; therefore, no additional action is required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for B-63 Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for REDOX Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for U Plant Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for LLBG-200W B for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗