Computational study of tungsten and depleted uranium photoneutron targets for a 20 MeV electron linear accelerator

Neutron production can be realized with a high energy electron linear accelerator by using Bremsstrahlung and photoneutron converters. In this study, Monte Carlo N-Particle Code (MCNP) was used to evaluate potential photonuclear target designs for a high energy electron linear accelerator for applications such as neutron radiography and neutron resonance spectroscopy. A computational model was developed to inform a target design that would yield a high number of neutrons. It consists of a 20 MeV electron beam incident on a Bremsstrahlung target and a photonuclear target to generate neutrons. This computational model showed that a thickness of 0.75 inches for both tungsten and depleted uranium yields the most neutrons from photoneutron reactions. Saturation in the total number of generated neutrons was observed at over 0.75-inch thickness for both evaluated materials. Depleted uranium yielded approximately twice the number of neutrons overall compared to tungsten. The highest neutron surface flux for Depleted Uranium was 1.06 × 10-4 neutrons/cm2/source electron, and for Tungsten it was 5.12 × 10-5 neutrons/cm2/source electron. The optimal target design for this study’s application would consist of a 0.75 inch-thick block of depleted uranium with the length, width, and/or diameter varying dependent on application.

43 PARTICLE ACCELERATORS↗

Computed tomography for non-destructive evaluation of composites: Applications and correlations

The state-of-the-art fabrication techniques for composite materials are such that stringent species-specific acceptance criteria must be generated to insure product reliability. Non-destructive evaluation techniques including computed tomography (CT), X-ray radiography (RT), and ultrasonic scanning (UT) are investigated and compared to determine their applicability and limitations to graphite epoxy, carbon-carbon, and carbon-phenolic materials. While the techniques appear complementary, CT is shown to provide significant, heretofore unattainable data. Finally, a correlation of NDE techniques to destructive analysis is presented.

Goldberg, B.↗

Developing Open-Source Training Materials for AI/ML and Space Biological Sciences Using NASA Cloud-Based Data

Artificial Intelligence (AI) and Machine Learning (ML) has gained significant traction in the biological and biomedical research fields in the last two decades, in part thanks to an increasing culture of open data sharing and reuse. Due to its capability for identifying complex relationships and patterns, AI/ML methodology is particularly well suited to recognize and predict biological patterns from high-dimensional next-generation sequencing data (e.g. whole genome sequencing, transcriptomic sequencing), as well as from biological or medical imaging data (e.g. microscopy, computed tomography, ultrasound, magnetic resonance imaging, radiography). These methodologies hold particular promise for space biosciences research and automated space health monitoring systems. However, there are many key considerations for properly training, validating, and testing a machine learning model in biological research or clinical application. Even with the positive culture of Open Science and data sharing, inexperienced researchers working quickly without proper checks can produce models that perform poorly outside of the immediate training dataset. Lessons learned from biological AI/ML research indicate that Open Science principles such as data sharing and open-source code must go hand-in-hand with publicly available, high-quality training curricula in best practices, with modules centered on real-life scientific use cases and data so future AI/ML practitioners gain experience on real problems. Here we present the development of open-source training materials for AI/ML and space biosciences, as part of the NASA Transform to Open Science Training (TOPST) initiative. We develop 4 independent training programs, focused on the following topics: 1) Fundamentals of Machine Learning and Space Biosciences Domain, 2) Open Science, Artificial Intelligence, and Ethical Best Practices for Data Sharing and Analysis, 3) Using AI/ML Classification to Identify Gene Networks Affected By Space Exposure in Mouse Liver, and 4) Using Neural Networks to Find DNA Damage Patterns in Immune Cells after Radiation. All programs leverage cloud-based NASA biological datasets. The curriculum we present will enable worldwide access to training in AI/ML and scientific analysis.

James Andrew Casaletto↗

Developing Open-Source Training Materials for AI/ML and Space Biological Sciences Using NASA Cloud-Based Data

Artificial Intelligence (AI) and Machine Learning (ML) has gained significant traction in the biological and biomedical research fields, in part due to a culture of open data sharing and reuse. AI/ML methodology is well-suited to recognize and predict biological patterns from high-dimensional next-generation sequencing data (e.g. whole genome sequencing, transcriptomic sequencing), as well as from biological or medical imaging data (e.g. microscopy, computed tomography, ultrasound, magnetic resonance imaging, radiography). These methodologies hold particular promise for space biosciences research and automated space health monitoring systems. However, there are key considerations for properly training, validating, and testing a machine learning model in biological research or clinical application. Inexperienced researchers can produce models that perform poorly outside of the training dataset. Open Science principles such as data sharing and open-source code must go hand-in-hand with publicly available, high-quality training curricula in best practices, with modules centered on real-life scientific use cases and data so future AI/ML practitioners gain experience on real problems. Here we present the development of open-source training materials for AI/ML and space biosciences, as part of the NASA Transform to Open Science Training (TOPST) initiative. We develop 4 independent training programs, focused on the following topics: 1) Fundamentals of Machine Learning and Space Biosciences Domain, 2) Open Science, Artificial Intelligence, and Ethical Best Practices for Data Sharing and Analysis, 3) Using AI/ML Classification to Identify Gene Networks Affected By Space Exposure in Mouse Liver, and 4) Using Neural Networks to Find DNA Damage Patterns in Immune Cells after Radiation. All programs leverage cloud-based NASA biological datasets. The curriculum we present will enable worldwide access to training in AI/ML and scientific analysis.

James Casaletto↗

Nondestructive evaluation of advanced ceramics

A review is presented of Lewis Research Center efforts to develop nondestructive evaluation techniques for characterizing advanced ceramic materials. Various approaches involved the use of analytical ultrasonics to characterize monolythic ceramic microstructures, acousto-ultrasonics for characterizing ceramic matrix composites, damage monitoring in impact specimens by microfocus X-ray radiography and scanning ultrasonics, and high resolution computed X-ray tomography to identify structural features in fiber reinforced ceramics.

Klima, Stanley J.↗

X-ray Inspection Model Validation with Physical Dosimetry

A non-functional printed circuit board assembly was developed using ULTIboard and a simple computational transport model was created for use with the Monte Carlo software MCNP. EBT 3 film radiography was used to compare with Monte Carlo simulation to validate the board representation. The computational transport model was then revised to include connection pins, solder balls, highly attenuating internal structures, and copper trace distribution. Results from the revised model were compared to the EBT 3 films to observe improvements to dose profiles. It was found that this method was useful in verifying the placement of components, as the dose profiles were observed to follow the same trends. The experiment was then repeated using XRQA 2 films to achieve the same level of contrast with 1% the dose of EBT 3 films. It was found that high contrast may be achieved using these films to identify major issues with the model geometry, at a cost of dose profile accuracy. A second validation method was applied to the model using 37 CaF 2 thermoluminescent dosimeters (TLDs). TLD measurements were compared with the simplified and complex transport models to identify the features that have the greatest impact on simulation accuracy. The TLD calibration to CaF 2 was found to be accurate within 5.6%, while calibration to dose in Si was found to be accurate within 4.7%. Finally, it was observed that the accurate representation of solder balls and proper modeling of highly attenuating internal structures had the greatest impact on simulation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

A Computed Tomography Automation Architecture Developed from a Comprehensive Literature Review

This paper presents a literature review on techniques related to the computed tomography procedure that incorporate automation elements in their research investigations or industrial applications. Computed tomography (CT) is a non-destructive testing (NDT) technique in that the imaging and inspection are performed without damaging the sample, allowing for additional or repeated analysis if necessary. The reviewed literature is organized based on the steps associated with a general NDT task in order to define an end-to-end computed tomography automation architecture. The process steps include activities prior to image collection, during the scan, and after the data are collected. It further reviews efforts related to repeating this process based on a previous scan result. By analyzing the multiple existing but disparate efforts found in the literature, we present a framework for fully automating NDT procedures and discuss the remaining technical gaps in the developed framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A review of computer aided interpretation technology for the evaluation of radiographs of aluminum welds

Industrial radiography is a well established, reliable means of providing nondestructive structural integrity information. The majority of industrial radiographs are interpreted by trained human eyes using transmitted light and various visual aids. Hundreds of miles of radiographic information are evaluated, documented and archived annually. In many instances, there are serious considerations in terms of interpreter fatigue, subjectivity and limited archival space. Quite often it is difficult to quickly retrieve radiographic information for further analysis or investigation. Methods of improving the quality and efficiency of the radiographic process are being explored, developed and incorporated whenever feasible. High resolution cameras, digital image processing, and mass digital data storage offer interesting possibilities for improving the industrial radiographic process. A review is presented of computer aided radiographic interpretation technology in terms of how it could be used to enhance the radiographic interpretation process in evaluating radiographs of aluminum welds.

Lloyd, J. F., Sr.↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Livermore Computed Tomography Input/Output library

Read, write, and connect visualizers to data for LLNL radiography and CT tools (e.g. LTT: https://softwarelicensing.llnl.gov/product/livermore-tomography-tools-ltt).

Vardar-Irrgang, MichaelE [Lawrence Livermore Natio↗

Assessment of metabolic bone diseases by quantitative computed tomography

Advances in the radiologic sciences have permitted the development of numerous noninvasive techniques for measuring the mineral content of bone, with varying degrees of precision, accuracy, and sensitivity. The techniques of standard radiography, radiogrammetry, photodensitometry, Compton scattering, neutron activation analysis, single and dual photon absorptiometry, and quantitative computed tomography (QCT) are described and reviewed in depth. Results from previous cross-sectional and longitudinal QCT investigations are given. They then describe a current investigation in which they studied 269 subjects, including 173 normal women, 34 patients with hyperparathyroidism, 24 patients with steroid-induced osteoporosis, and 38 men with idiopathic osteoporosis. Spinal quantitative computed tomography, radiogrammetry, and single photon absorptiometry were performed, and a spinal fracture index was calculated on all patients. The authors found a disproportionate loss of spinal trabecular mineral compared to appendicular mineral in the men with idiopathic osteoporosis and the patients with steroid-induced osteoporosis. They observed roughly equivalent mineral loss in both the appendicular and axial regions in the hyperparathyroid patients. The appendicular cortical measurements correlated moderately well with each other but less well with spinal trabecular QCT. The spinal fracture index correlated well with QCT and less well with the appendicular measurements. Knowledge of appendicular cortical mineral status is important in its own right but is not a valid predictor of axial trabecular mineral status, which may be disproportionately decreased in certain diseases. Quantitative CT provides a reliable means of assessing the latter region of the skeleton, correlates well with the spinal fracture index (a semiquantitative measurement of end-organ failure), and offers the clinician a sensitive means of following the effects of therapy.

Minerals/analysis↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Engine materials characterization and damage monitoring by using x ray technologies

X ray attenuation measurement systems that are capable of characterizing density variations in monolithic ceramics and damage due to processing and/or mechanical testing in ceramic and intermetallic matrix composites are developed and applied. Noninvasive monitoring of damage accumulation and failure sequences in ceramic matrix composites is used during room-temperature tensile testing. This work resulted in the development of a point-scan digital radiography system and an in situ x ray material testing system. The former is used to characterize silicon carbide and silicon nitride specimens, and the latter is used to image the failure behavior of silicon-carbide-fiber-reinforced, reaction-bonded silicon nitride matrix composites. State-of-the-art x ray computed tomography is investigated to determine its capabilities and limitations in characterizing density variations of subscale engine components (e.g., a silicon carbide rotor, a silicon nitride blade, and a silicon-carbide-fiber-reinforced beta titanium matrix rod, rotor, and ring). Microfocus radiography, conventional radiography, scanning acoustic microscopy, and metallography are used to substantiate the x ray computed tomography findings. Point-scan digital radiography is a viable technique for characterizing density variations in monolithic ceramic specimens. But it is very limited and time consuming in characterizing ceramic matrix composites. Precise x ray attenuation measurements, reflecting minute density variations, are achieved by photon counting and by using microcollimators at the source and the detector. X ray computed tomography is found to be a unique x ray attenuation measurement technique capable of providing cross-sectional spatial density information in monolithic ceramics and metal matrix composites. X ray computed tomography is proven to accelerate generic composite component development. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results from one-, three-, five-, and eight-ply ceramic composite specimens show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber-matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. In situ film radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction-bonded silicon nitride matrix. It is concluded that pretest, in situ, and post-test x ray imaging can provide greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

Micro X-ray computed tomography examination of mini plate fuel with hot isostatic pressed aluminum cladding

In order to minimize proliferation risks and improve security of nuclear material, the United States high performance research and test reactors (USHPRR) program is tasked with converting nuclear reactors that are fueled with highly enriched uranium (HEU) fuels to operate with low-enriched uranium (LEU) nuclear fuels. One favorable LEU fuel configuration is plate fuel with a metallic uranium-molybdenum foil clad within an aluminum alloy (AA 6061). In this fuel, the aluminum cladding is bonded with a hot isostatic pressing (HIP) method to seal the cladding around the fuel meat. However, the HIP process parameters influence the cladding performance, as a defective or incomplete bond can cause a pathway for corrosion. Micro X-ray computed tomography (XCT), a nondestructive technique that provides volumetric imaging, can be applied to inspect fuel plate cladding at the engineering scale. In this work, XCT methodology was developed and successfully utilized to not only observe the bond line of unirradiated mini fuel plates, but to also identify subsurface abnormalities in the plates’ cladding. Importantly, in future work, this technique could be applied to fuel plates, pre- and post-irradiation, to quantify irradiation effects on cladding defects and bond line integrity.

36 MATERIALS SCIENCE↗

Bayes Inference Engine (BIE) Test Plan: TiltConeBeamComboDMGeometric

The Bayes Inference Engine (BIE) is a general software tool intended to be used primarily in the analysis of radiographic data for density. An analysis is set up in the BIE by representing the problem as a collection of modules called glyphs. All glyphs to be used in creating the forward model of the experiment will be tested separately for a range of inputs.

97 MATHEMATICS AND COMPUTING↗