Search NASA⌕ Search

SEARCH · Search NASA

Results for “computer program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

APPLICATION OF THE FAVOR-OCI FRACTURE MECHANICS COMPUTER PROGRAM TO ASME CODE SECTION XI, IWB-3610 FLAW ACCEPTANCE CRITERIA EVALUATIONS

This paper presents an overview of added features in a new version of the FAVOR (Fracture Analysis of Vessels Oak Ridge) computer code called FAVOR-OCI. The original FAVOR code was developed at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) under the sponsorship of the US Nuclear Regulatory Commission (NRC). FAVOR is applied by US and international nuclear power industries to perform deterministic and probabilistic fracture mechanics analyses of commercial nuclear reactor pressure vessels (RPVs). Appli-cations of FAVOR are focused on insuring that the structural integrity of aging, and increasingly embrittled, RPVs is main-tained throughout their licensed service life. Based on the final ORNL release of FAVOR, v16.1, FAVOR-OCI extends existing deterministic features of FAVOR while preserving all prev-iously-existing probabilistic capabilities of FAVOR.The objective of this paper is to describe new deterministic features in FAVOR-OCI that can be applied to analytical evaluations of planar flaws. These evaluations are consistent with the acceptance criteria of ASME Code, Section XI, Article IWB-3610, including Subarticles IWB-3611 (acceptance based on flaw size) and IWB-3612 (acceptance based on applied stress intensity factor). The linear elastic fracture mechanics (LEFM) capabilities of FAVOR-OCI also incorporate the analytical procedures presented in the Nonmandatory Appendix A, Analysis of Flaws, Article A-3000, Method of KI Determination, for both surface and subsurface (embedded) flaws.The paper describes a computational methodology for determining critical values of fracture-related parameters that satisfy ASME Code Section XI acceptance criteria for flaws exposed to multiple thermal-hydraulic transients. These com-pute-intensive analyses can be carried out with a single execution of FAVOR-OCI. The new methodology determines critical values by solving for either the point of tangency or point of intersection between applied KI versus time histories and a user-selected fracture toughness material property (e.g., ASME KIc, FAVOR Weibull KIc, or Master Curve Weibull KJc) for surface or subsurface flaws. Situations where warm prestress conditions apply can also be addressed. The paper highlights a need for this new capability via applications to a recent independent review of safety cases for RPVs in two Belgian nuclear power plants (NPPs). That review required ASME Section XI assessments of several thousand embedded, quasi-laminar flaws in the wall of each RPV. Analysis results provided by the new capability contributed to the technical bases compiled from several sources by the Belgian nuclear regulatory agency (FANC) and eventually used by FANC to justify the restart of these NPPs.

Dickson, Terry L.↗

cBar: a computer program to distinguish plasmid-derived from chromosome-derived sequence fragments in metagenomics data

Huge amount of metagenomic sequence data have been produced as a result of the rapidly increasing efforts worldwide in studying microbial communities as a whole. Most, if not all, sequenced metagenomes are complex mixtures of chromosomal and plasmid sequence fragments from multiple organisms, possibly from different kingdoms. Computational methods for prediction of genomic elements such as genes are significantly different for chromosomes and plasmids, hence raising the need for separation of chromosomal from plasmid sequences in a metagenome. We present a program for classification of a metagenome set into chromosomal and plasmid sequences, based on their distinguishing pentamer frequencies. On a large training set consisting of all the sequenced prokaryotic chromosomes and plasmids, the program achieves ~92% in classification accuracy. On a large set of simulated metagenomes with sequence lengths ranging from 300 bp to 100 kbp, the program has classification accuracy from 64.45% to 88.75%. On a large independent test set, the program achieves 88.29% classification accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Systems, methods and computer program products for collaborative agent control

Systems, methods and unmanned agents for collaboratively controlling agents in a collaborative network by one or more agents continuously simulating numeric models of one or more other agents in the network to dramatically reduce the computational bandwidth required between agents, and improve the quality of shared estimates of the agent locations as well as the locations and characteristics of other objects of interest, e.g. targets. Bandwidth is reduced by using the models to intelligently filter data before communicating.

Buerger, Stephen↗

PABS: A Computer Program to Normalize Emission Probabilities and Calculate Realistic Uncertainties

The program PABS normalizes relative particle emission probabilities to an absolute scale and calculates the relevant uncertainties on this scale. The program is written in Java using the JDK 1.6 library. For additional information about system requirements, the code itself, and compiling from source, see the README file distributed with this program. The mathematical procedures used are given below.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method and system for knowledge discovery using non-linear statistical analysis and a 1st and 2nd tier computer program

The invention relates to a method and apparatus for simultaneously processing different sources of test data into informational data and then processing different categories of informational data into knowledge-based data. The knowledge-based data can then be communicated between nodes in a system of multiple computers according to rules for a type of complex, hierarchical computer system modeled on a human brain.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

WinPSSP : a revamp of the computer program PSSP and its performance solving the crystal structures of small organic compounds and solids of biological and pharmaceutical interest

The direct-space methods software Powder Structure Solution Program ( PSSP ) [Pagola & Stephens (2010). J. Appl. Cryst. 43 , 370–376] has been migrated to the Windows OS and the code has been optimized for fast runs. WinPSSP is a user-friendly graphical user interface that allows the input of preliminary crystal structure information, integrated intensities of the reflections and FWHM, the definition of structural parameters and a simulated annealing schedule, and the visualization of the calculated and experimental diffraction data overlaid for each individual solution. The solutions are reported as filename.cif files, which can be used to analyze packing motifs and chemical bonding, and to input the atomic coordinates into the Rietveld analysis software GSAS. WinPSSP performance in straightforward crystal structure determinations has been evaluated using 18 molecular solids with 6–20 degrees of freedom. The free-distribution program as well as multimedia tutorials can be accessed at http://users.uoi.gr/nkourkou/winpssp/.

60 APPLIED LIFE SCIENCES↗

The Computer Program LIAR for Beam Dynamics Calculations in Linear Accelerators

Linear accelerators are the central components of the proposed next generation of linear colliders. They need to provide acceleration of up to 750 GeV per beam while maintaining very small normalized emittances. Standard simulation programs, mainly developed for storage rings, do not meet the specific requirements for high energy linear accelerators. We present a new program LIAR ('LInear Accelerator Research code') that includes wakefield effects, a 6D coupled beam description, specific optimization algorithms and other advanced features. Its modular structure allows to use and to extend it easily for different purposes. The program is available for UNIX workstations and Windows PC's. It can be applied to a broad range of accelerators. We present examples of simulations for SLC and NLC.

43 PARTICLE ACCELERATORS↗

SNL Building - High Speed Computer: Program Requirements Document, Rev 1

This PRD is developed for multiple delivery options which have yet to be determined: The intent for the options is to allow for a risk analysis to be performed and determine the most appropriate location. Each location has benefits where others may not. These options will be vetted in a workshop December 7 and 8, 2016. Once an option is selected the requirements pertaining to options that are not selected will be removed from this PRD.

97 MATHEMATICS AND COMPUTING↗

Radiological Safety Analysis Computer Program V 7.2

Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences.

Jordan, RobertaA. [Idaho National Laboratory (INL)↗

Computer Programs For Analysis Of Thermally Reactive Tracer Tests In Geothermal Reservoirs

The Tracer Analysis Toolbox (TAT) is a stand-alone executable software package that focuses on reservoir monitoring, using changes in concentration of thermally degrading tracers between and injection well and a production well to reflect the temperature-time histories along flow paths through the reservoir. By conducting such tests periodically, the thermal evolution of the flow paths connecting injection wells to production wells can be monitored. Because this approach is sensitive to temperature along the whole path, it can detect changes well before they occur at the distal end of the path (i.e., the production well). Thus, the thermally degrading tracer method provides early detection of thermal decline before it impacts that well. The goal of TAT is to simplify planning of a reactive tracer monitoring campaign and interpretation of results by providing: (1) tracer test planning and analysis tools to define the necessary kinetic parameters, injection concentrations, and other tracer parameters that are suitable for the expected reservoir residence time and temperature, (2) identification of tracers with suitable characteristics (defined by (1)) and (3) a suite of analysis programs to analyze tracer test results.

Plummer, MitchellAaron [Idaho National Laboratory ↗

Method, system and computer program product for monitoring and optimizing fluid extraction from geologic strata

An arrangement which utilizes an inexpensive flap valve/flow transducer combination and a simple local supervisory control system to monitor and/or control the operation of a positive displacement pump used to extract petroleum from geologic strata. The local supervisory control system controls the operation of an electric motor which drives a reciprocating positive displacement pump so as to maximize the volume of petroleum extracted from the well per pump stroke while minimizing electricity usage and pump-off situations. By reducing the electrical demand and pump-off (i.e., "pounding" or "fluid pound") occurrences, operating and maintenance costs should be reduced sufficiently to allow petroleum recovery from marginally productive petroleum fields. The local supervisory control system includes one or more applications to at least collect flow signal data generated during operation of the positive displacement pump. No flow, low flow and flow duration are easily evaluated using the flap valve/flow transducer arrangement.

58 GEOSCIENCES↗