Search NASA⌕ Search

SEARCH · Search NASA

Results for “condensation nuclei counter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Counting Particles Emitted by Stratospheric Aircraft and Measuring Size of Particles Emitted by Stratospheric Aircraft

There were two principal objectives of the cooperative agreement between NASA and the University of Denver. The first goal was to modify the design of the ER-2 condensation nuclei counter (CNC) so that the effective lower detection limit would be improved at high altitudes. This improvement was sought because, in the instrument used prior to 1993, diffusion losses prevented the smallest detectable particles from reaching the detection volume of the instrument during operation at low pressure. Therefore, in spite of the sensor's ability to detect particles as small as 0.008 microns in diameter, many of these particles were lost in transport to the sensing region and were not counted. Most of the particles emitted by aircraft are smaller than 0.1 micron in diameter. At the start date of this work, May 1990, continuous sizing techniques available on the ER-2 were only capable of detecting particles larger than 0.17 micron. Thus, the second objective of this work was to evaluate candidate sizing techniques in an effort to gain additional information concerning the size of particles emitted by aircraft.

Wilson, James Charles↗

Cloud-Aerosol Interactions in Tropical Storms

During the Coupled Ocean-Atmosphere Response Experiment (COARE) of the Tropical Ocean and the Global Atmosphere (TOGA) program we measured cloud and aerosol particles aboard the NASA DC-8 over the warm pool of the western Pacific. Instruments on the aircraft included a condensation nuclei counter, optical particle counters, two-dimensional shadow probes and an ice crystal replicator. The size range covered by these instruments was from =0.01 micron to 6.4 mm diameter; particle shapes were determined for particles of sizes D greater than 1 micron.

Puesschel, R. F.↗

62°S Witnesses the Transition of Boundary Layer Marine Aerosol Pattern Over the Southern Ocean (50°S–68°S, 63°E– 150°E) During the Spring and Summer: Results From MARCUS (I)

The Atmospheric Radiation Measurement Mobile Facility-2 was installed onboard the research vessel Aurora Australis to measure aerosol properties during the 2017-2018 Measurement of Aerosols, Radiation, and CloUds over the pristine Southern ocean (MARCUS) Experiment, providing unique data on aerosols latitudinal and seasonal variation, including south of 60 degrees S where previous observations are scarce. Data from a Cloud Condensation Nuclei (CCN) counter and Ultra-High-Sensitivity Aerosol Spectrometer show that both the number concentration (N-CCN) and size distribution of CCN-active aerosols, with diameters (D) between 60 nm < D < 1,000 nm are different over the North Southern Ocean (NSO) (50 degrees S-60 degrees S) and the South Southern Ocean (SSO) (62 degrees S-68 degrees S). The average NSO N-CCN at 0.2% and 0.5% supersaturation were 28% and 49% less than that over the SSO. This increase of CCN over the SSO is caused by the increase of aerosols with 60 nm < D < 200 nm, consistent with calculations of Aerosol Scattering Angstrom Exponents derived from a nephelometer. Aerosol hygroscopicity growth factor measured by the Hygroscopic Tandem Differential Mobility Analyzer stayed close to 1.41 for aerosols with 50 nm < D < 250 nm over the SSO, but increased from 1.30 to 1.67 over the NSO, indicating different chemical compositions. Both CCN and Ice Nucleating Particles (INPs) showed a stronger variation with season than with latitude. The variation of heat-labile and presumably proteinacous INPs suggests an increase of ice nucleating-active microbes in summer.

Niu, Qing↗

Can disposable masks be worn more than once?

Disposable facemasks are a primary tool to prevent the transmission of SARS-COV-2 during the COVID-19 pandemic. However, plastic waste generated from their disposal represents a significant environmental problem that can be reduced by maximizing the service life of disposable masks. We evaluated the effect of repeated wearing on the fitted filtration efficiency (FFE) of N95, KF94, KN95, and procedure/surgical masks. The FFEs of masks were compared following extended wearing with and without washing. Results reveal that most disposable facemasks can retain a high level of their baseline FFE after extended wearing, even after 40 h of wearing. Laundering disposable masks degraded FFE in some instances. We conclude that the durability of disposable facemask performance is considerably longer than their intended single use indication, suggesting that reusing disposable masks is a safe means of reducing plastic waste in the environment.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

42 ENGINEERING↗

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

CCN PI sample dataset from two BNF facilities

This dataset contains CCN instrument data files showing the sample time series of CCN concentrations in #/cm^3. The file also shows the instrument records and CCN data. The CCN_S20_data_250605000000.csv data file contains information from the S20 facility at Courteland, and the CCN_S30_data_250605000000.csv data file contains information from the S30 facility at Falkville. See the attached CCN-200 Manual for information about the variables and units with the data files.

ccn↗

Vertical profiles of condensation nuclei

Condensation nuclei measurements using a low supersaturation (about 10%) thermal gradient diffusion cloud chamber (TGDCC) and a high supersaturation (about 200%) expansion type instrument were compared on a series of three balloon flights over Laramie, Wyoming. In general, the two instruments produced similar vertical profiles but some discrepancies remain unexplained. Agreement between the two would indicate that the low supersaturations used in the TGDCC were still large enough to cause the instrument to count essentially all of the particles present. The TGDCC condensation nuclei (CN) counter was flown at several sites in both the Northern and Southern Hemispheres. The results indicate the existence of a relative maximum in the CN mixing ratio associated with the upper equatorial troposphere and what appears to be a worldwide constant mixing ratio of CN above 20-25 km.

Rosen, J. M.↗

Unusual behavior in the condensation nuclei concentration at 30 km

The result obtained with an improved balloon-borne condensation nuclei (CN) counter that is capable of operating to altitudes of at least 30 km are presented. Of major interest is the appearance of a quasiannual variation near 30 km which could be described by a sudden concentration increase of unusually small particles occurring in the winter or spring followed by a 1- to 3-month decay period to background levels. The magnitude of the variation has increased dramatically following the recent generally high levels of volcanic activity affecting the lower stratosphere. Several potential explanations for the event are considered, but none appear entirely satisfactory or complete at the present time. The explanation with the fewest drawbacks would attribute the production of growth of the new cn to a highly supersaturated H2SO4 vapor layer generated by any one of several proposed processes in the upper high latitude stratosphere.

Rosen, J. M.↗

Test results from a comparative evaluation of a condensation nuclei fire detector

The fire/smoke alarm response of a condensation nuclei fire detector (CNFD) was compared with photoelectric and ionization detectors. Tests were conducted in a former control room 8.5 m by 8.9 with a 2.7 m ceiling. The room had air supplied from above the ceiling and under the floor with return air exiting from ceiling grills. The environment was varied from 278 to 305 K and relative humidities from 8 to 65%. Four detection zones were located in the room. Each zone contained a sampling head for the CNDF, a photodetector, and an ionization detector so that each detector system had four opportunities to alarm during tests. The particle level in the test room was also monitored during tests with a condensation nuclei particle counter. The CNFD responded to 90% of exposures to smoldering plastic and 84% of exposures to visible fire. The photoelectric response was 43 and 12.5% respectively for the same conditions. The ionization response was 9 and 48 respectively.

Bricker, R. W.↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗

Particle size distributions from TRACER-MAP

Particle size distributions measured using a custom scanning mobility analyzer (SMPS) and a TSI, Inc. aerodynamic particle sizer (APS). The size distributions measured with the two instruments were merged during data inversion to produce a single distribution spanning a diameter range from approximately 19 nanometers to 15 micrometers. Size-dependent cloud condensation nuclei (CCN) activity measured with a CCN counter operated in parallel to the condensation particle counter in the SMPS are reported separately. The measurements were made from the Baylor University/University of Houston Mobile Air Quality Laboratory (MAQL) between July 5 and August 30, 2022 during the TRACER-MAP project. The trailer moved between five sites in the Houston regions as follows: Aldine: 7/5-7/8, 7/21-7/26, 8/15-8/24 University of Houston: 7/8-7/16, 8/8-8/15 San Jacinto monument: 7/16-7/21 Jones State Forest: 7/26-8/1; 8/24-8/30 AMF site in La Porte: 8/1-8/8

54 ENVIRONMENTAL SCIENCES↗

Particle size distributions from TRACER-MAP

Particle size distributions measured using a custom scanning mobility analyzer (SMPS) and a TSI, Inc. aerodynamic particle sizer (APS). The size distributions measured with the two instruments were merged during data inversion to produce a single distribution spanning a diameter range from approximately 19 nanometers to 15 micrometers. Size-dependent cloud condensation nuclei (CCN) activity measured with a CCN counter operated in parallel to the condensation particle counter in the SMPS are reported separately. The measurements were made from the Baylor University/University of Houston Mobile Air Quality Laboratory (MAQL) between July 5 and August 30, 2022 during the TRACER-MAP project. The trailer moved between five sites in the Houston regions as follows: Aldine: 7/5-7/8, 7/21-7/26, 8/15-8/24 University of Houston: 7/8-7/16, 8/8-8/15 San Jacinto monument: 7/16-7/21 Jones State Forest: 7/26-8/1; 8/24-8/30 AMF site in La Porte: 8/1-8/8

54 ENVIRONMENTAL SCIENCES↗

Concentrations of condensation nuclei in the vicinity of jetstream maxima

Ozone and condensation nuclei were measured on March 29, 1977 (and March 30, GMT) from a Sabreliner in a frontal zone south of Denver, Colo. The ozone served as a tracer for stratospheric air and the condensation nuclei as a tracer for tropospheric air. Both the Langer condensation nucleus counter and the Rich-100 counter can be used to measure condensation nucleus concentrations in the vicinity of the tropopause. However, the former counter is more sensitive to low concentrations. The nuclei measured were found to be almost entirely larger than 0.005 micron in radius, consisting of thousands of molecules. The mesostructure of the ozone and condensation nucleus concentrations agreed well with a double structure of the frontal zone that became apparent from a detailed analysis of radiosonde data.

Cadle, R. D.↗

Investigating Spatial Variability of Aerosol, Cloud Condensation Nuclei, and Ice Nucleating Particles in Mountainous Terrain Field Campaign Report

The U.S. Department of Energy Atmospheric System Research (ASR)-supported Surface Atmosphere Integrated Field Laboratory (SAIL) campaign in the East River Watershed (ERW) of the Upper Colorado River Basin in southwestern Colorado ran from fall 2021 to spring 2023. Two monitoring sites were deployed in the ERW as part of SAIL. The two sites were the Aerosol Observation System (AOS) located on Crested Butte Ski Mountain, and the second ARM Mobile Facility (AMF2), located at the Rocky Mountain Biological Laboratory in Gothic, Colorado. To gain a more comprehensive understanding of aerosols in complex, mountainous terrain, Handix Scientific deployed SAIL-Net, a distributed network of six measurement nodes spanning the domain of the SAIL research area from October 2021 to July 2023. Each node measured aerosol particles between 140 nm and 3.4 μm in diameter using a small portable optical particle spectrometer (POPS; Gao et al. 2016), cloud condensation nuclei (CNN) using a miniature CCN counter (CloudPuck), and ice nucleating particles (INP) using the time-resolved aerosol filter sampler (TRAPS; Creamean et al. 2018). Our approach was similar to other studies that aimed to better characterize and understand aerosols and gas-phase pollutants using networks of lower-cost sensors (Caubel et al. 2019, Kelly et al. 2021, Asher et al. 2022). Such studies have identified neighborhood-level variations in pollutant concentrations (Schneider et al. 2017, Popoola et al. 2018, Caubel et al. 2019). Small-scale variations such as this are poorly represented in models and poorly measured by a single monitoring system (Caubel et al. 2019). Previous work has shown the representation error (the ability of measurements to represent a larger area) increases with complex orography, leading to decreases in model accuracy (Schutgens et al. 2017). The overall goal of SAIL-Net was to improve our understanding of the variability of aerosol in the ERW, thus increasing our knowledge of aerosol-cloud interactions in this region and informing the usefulness of distributed networks of measurements for future studies. We met this goal by answering the following science questions: 1. What is the aerosol temporal variability, and how does aerosol inhomogeneity vary seasonally? Is there significant seasonal variability in sources, or are short-term meteorological conditions the most important determining factor in sources for cloud nuclei? 2. What is the aerosol spatial variability? What are the aerosol characteristics at cloud base, presumably the particles most representative of those acting as cloud nuclei? 3. How should measurement networks be designed to capture aerosol-cloud interactions, and what do they need to measure? Can a single measurement site accurately represent aerosol properties in regions of complex terrain? SAIL-Net consisted of six measurement nodes spread across the ERW near Crested Butte, Colorado. The primary objective in site placement was to select locations that captured the vertical variation in aerosol properties while also spanning the domain of the SAIL campaign. The elevation of the sites ranged from roughly 2750 m along the valley floor of the ERW to approximately 3500 m near the top of Crested Butte Mountain, which is one of the taller peaks in the ERW. The farthest distance between sites was 14 km, while the closest two sites were approximately 1 km apart. Two of the sites were collocated with the ARM SAIL sites; our instruments sat on top of one of the trailers at AOS and another one of our sites was located in a meadow just above AMF2.

54 ENVIRONMENTAL SCIENCES↗

Observations of condensation nuclei in the 1987 airborne Antarctic ozone experiment

The condensation nucleus counter (CNC) flown of the NASA ER-2 in the Airborne Antarctic Ozone Experiment provides a measurement of the number mixing ratio of particles which can be grown by exposure to supersaturated n-butyl alcohol vapor to diameters of a few microns. Such particles are referred to as condensation nuclei (CN). The ER-2 CNC was calibrated with aerosols of known size and concentration and was found to provide an accurate measure of the number concentration of particles larger than about 0.02 micron. Since the number distribution of stratospheric aerosols is usually dominated by particles less than a few tenths of micron in diameter, the upper cutoff of the ER-2 CNC has not been determined experimentally. However, theory suggests that the sampling and counting efficiency should remain near one for particles as large as 1 micron in diameter. Thus, the CN mixing ratio is usually a good measure of the mixing ratio of submicron particles.

Wilson, J. C.↗

The Third International Cloud Condensation Nuclei Workshop

Twenty-five instruments were tested, including size characterization devices and two Aitken counters. The test aerosols were supplied to the instruments by an on-line generation system, thereby eliminating the need for storage bags. Cloud condensation chambers and haze chambers are highlighted.

Kocmond, W. C.↗

Cloud Condensation Nuclei Hygroscopicity Value-Added Product Report

The purpose of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Cloud Condensation Nuclei Hygroscopicity Parameter (AOSCCNSMPSKAPPA and AOSCCNUHSASKAPPA) Value-Added Product (VAP) is to calculate the hygroscopicity parameter, kappa, to quantify the ability of aerosols to activate into cloud water droplets. The hygroscopicity parameter is often used to model the cloud condensation nuclei (CCN) activity of atmospheric aerosols of different sizes and compositions, providing additional insight on the influence of aerosols on climate. The AOSCCNUHSASKAPPA VAP was recently developed to provides kappa data for ARM sites where AOSCCNSMPSKAPPA was missing. Laboratory experiments show that the kappa values for highly hygroscopic aerosols vary from 0.5 to 1.4 (Petters and Kreidenweis 2007). For organic compounds they are observed to vary between 0.01 and 0.5. For non-hygroscopic aerosols, such as soot, kappa values are very close to zero. Ambient aerosols are complex mixtures of organic and inorganic compounds and previous observations indicate that kappa values for these aerosols typically vary from 0.05 to 0.9 (Petters and Kreidenweis 2007).

54 ENVIRONMENTAL SCIENCES↗