Search NASA⌕ Search

SEARCH · Search NASA

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

Optimal Renewable Resource Allocation and Load Scheduling of Resilient Communities

This paper presents a methodology for enhancing community resilience through optimal renewable resource allocation and load scheduling in order to minimize unserved load and thermal discomfort. The proposed control architecture distributes the computational effort and is easier to be scaled up than traditional centralized control. The decentralized control architecture consists of two layers: The community operator layer (COL) allocates the limited amount of renewable energy resource according to the power flexibility of each building. The building agent layer (BAL) addresses the optimal load scheduling problem for each building with the allowable load determined by the COL. Both layers are formulated as a model predictive control (MPC) based optimization. Simulation scenarios are designed to compare different combinations of building weighting methods and objective functions to provide guidance for real-world deployment by community and microgrid operators. The results indicate that the impact of power flexibility is more prominent than the weighting factor to the resource allocation process. Allocation based purely on occupancy status could lead to an increase of PV curtailment. Further, it is necessary for the building agent to have multi-objective optimization to minimize unserved load ratio and maximize comfort simultaneously.

model predictive control↗

Energy Options Analysis Project (Final Report)

This Bear River Band of Rohnerville Rancheria (BRB) Energy Options Analysis Project provides a rigorous and comprehensive near-term renewable energy implementation plan that aligns with the BRB’s long term strategic vision of “zero net annual utility energy consumption.” Final recommendations were arrived at by following four key project phases:A gas and electricity load assessment was conducted for all existing buildings using historic consumption data, and projected loads of new or anticipated buildings using building designs. A renewable energy resource assessment was conducted that estimated the gross generation potential of solar and wind, constrained to areas that could potentially be developed. Other renewable generation technologies were not considered feasible to meet the loads of the BRB. Demand-side efficiency and fuel switching opportunities were identified that can reduce electrical and gas consumption. These opportunities were not integrated into the load assessment in order to provide a conservative implementation plan, but are recommended to be pursued in order to cost-optimize projects during a feasibility assessment. A strategic vision advisory committee was organized and consulted when iterating on the viability of possible projects. These project phases resulted in finalizing the following three solar PV projects for the near term, which also lay the foundation for a future community-scale or multiple-facility microgrid for added resiliency. Additional solar PV on the hillside south of the Tish-Non Community Center. Solar plus battery storage microgrid at the Pump & Play fuel station. Solar PV at the Casino.

14 SOLAR ENERGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Probabilistic Assessment of Structural Integrity

A probability-based approach, combining deterministic and probabilistic methods, was developed for analyzing building and component failures, which are especially crucial for complex structures like nuclear power plants. This method links finite element and probabilistic software to assess structural integrity under static and dynamic loads. This study uses NEPTUNE software, which is validated, for a deterministic transient analysis and ProFES software for probabilistic models. In a case study, deterministic analyses with varied random variables were transferred to ProFES for probabilistic analyses of piping failure and wall damage. A Monte Carlo Simulation, First-Order Reliability Method, and combined methods were employed for probabilistic analyses under severe transient loading, focusing on a postulated accident at the Ignalina Nuclear Power Plant. The study considered uncertainties in material properties, component geometry, and loads. The results showed the Monte Carlo Simulation method to be conservative for high failure probabilities but less so for low probabilities. The Response Surface/Monte Carlo Simulation method explored the impact load–failure probability relationship. Given the uncertainties in material properties and loads in complex structures, a deterministic analysis alone is insufficient. Probabilistic analysis is imperative for extreme loading events and credible structural safety evaluations.

Mathematics↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

A Comparison of PV Resource Modeling for Sizing Microgrid Components

Microgrid systems are being deployed with increased frequency to meet critical building loads during unplanned power outages. Determining the appropriate type and size of components that make up a microgrid can greatly affect its ability to meet this need. This paper presents a new tool to appropriately size PV, battery, and generator capacities to meet all site loads, given a resilience goal. It uses a statistical model to simulate microgrid behavior under a large range of solar resource conditions, providing resilience planners with confidence that critical loads will be met even under extreme weather conditions. We compare this model with one that uses typical weather data for sizing microgrids, and quantify the resilience effects of using these different methods. Our method produces more conservative generator capacities and fuel requirements in an outage, predicting up to 30% more fuel required in the most extreme case. Microgrid systems that are designed using more conservative estimates are more likely to continue to serve load during emergency outages under a large range of conditions.

Newman, Sarah F.↗

Managing Army Plug Load Equipment Energy Use: Office Equipment

Office equipment covers a large and diverse group of plug load devices. Policies focused on equipment purchase, power management, and usage limitations can save the Army more than 10 million kWh and $620K per year within just four building categories. This represents a top opportunity for energy- and cost-savings identified by a recent Army plug load study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OPFLearnData: Dataset for Learning AC Optimal Power Flow

The datasets are resulting from OPFLearn.jl, a Julia package for creating AC OPF datasets. The package was developed to provide researchers with a standardized way to efficiently create AC OPF datasets that are representative of more of the AC OPF feasible load space compared to typical dataset creation methods. The OPFLearn dataset creation method uses a relaxed AC OPF formulation to reduce the volume of the unclassified input space throughout the dataset creation process. The dataset contains load profiles and their respective optimal primal and dual solutions. Load samples are processed using AC OPF formulations from PowerModels.jl. More information on the dataset creation method can be found in our publication, "OPF-Learn: An Open-Source Framework for Creating Representative AC Optimal Power Flow Datasets" and in the package website: https://github.com/NREL/OPFLearn.jl.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-driven Approach for Predicting Nepheline Crystallization in High-Level Waste Glasses

High-level waste (HLW) glasses with high aluminum content are prone to nepheline crystallization during the slow canister cooling that is experienced during large-scale production. Due to its detrimental effects on glass durability, nepheline precipitation must be avoided; however, developing robust, predictive models for nepheline crystallization behavior in HLW glasses is difficult due to their compositional complexity. Using overly conservative constraints to predict nepheline formation can limit the waste loading to lower than the achievable capacity. In this study, a robust data-driven model using five compositional features has been developed to predict nepheline formation. The analysis of the model and the data show that there is an overlap, instead of a distinct compositional boundary, between glasses that form and do not form nepheline. As a result, the model’s predictive accuracy is not the same throughout the feature space and instead is dependent on the location of the glass composition in the dimensionally reduced feature space.

Sargin, Irmak↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space-conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code (ICC 2009) while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space-conditioning loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MFVI Energy Efficiency Audit Training Module 2.1: Plug Loads [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing plug load systems. As such, it will assist its user in documenting the plug loads in the space and then identifying the most efficient means of delivering those plug loads.

21CPP↗

An Open-Source Decarbonization Analytics Framework: Designing for Low-Carbon Emission Districts and Communities: Preprint

This paper introduces an open-source analytics framework designed to assist in creating low or net-zero carbon buildings and urban districts. Integrated within URBANopt, an open-source platform for energy analysis in districts and communities, this framework equips researchers, architects, engineers, and other stakeholders with tools to evaluate the carbon footprint implications of their design choices. The framework enables the analysis of various scenarios, incorporating both historical and future emission factors, and can span across different climate zones, each with distinct grid and emissions characteristics. The results showcase the framework's capability to evaluate the impact of design upgrades and control strategies on carbon emissions in districts and communities. An illustrative analysis using a hypothetical district in Denver, Colorado, shows reduced emissions from energy efficiency upgrades and control strategies, highlighting the sensitivity in their effects on emissions and energy use.

buildings energy efficiency↗

Generating realistic building electrical load profiles through the Generative Adversarial Network (GAN)

Building electrical load profiles can improve understanding of building energy efficiency, demand flexibility, and building-grid interactions. Current approaches to generating load profiles are time-consuming and not capable of reflecting the dynamic and stochastic behaviors of real buildings; some approaches also trigger data privacy concerns. In this study, we proposed a novel approach for generating realistic electrical load profiles of buildings through the Generative Adversarial Network (GAN), a machine learning technique that is capable of revealing an unknown probability distribution purely from data. The proposed approach has three main steps: (1) normalizing the daily 24-hour load profiles, (2) clustering the daily load profiles with the k-means algorithm, and (3) using GAN to generate daily load profiles for each cluster. The approach was tested with an open-source database – the Building Data Genome Project. We validated the proposed method by comparing the mean, standard deviation, and distribution of key parameters of the generated load profiles with those of the real ones. The KL divergence of the generated and real load profiles are within 0.3 for majority of parameters and clusters. Additionally, results showed the load profiles generated by GAN can capture not only the general trend but also the random variations of the actual electrical loads in buildings. We report the proposed GAN approach can be used to generate building electrical load profiles, verify other load profile generation models, detect changes to load profiles, and more importantly, anonymize smart meter data for sharing, to support research and applications of grid-interactive efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extrapolation of the Rainflow-Counted Load Ranges for Fatigue Assessment of the Wind Turbine's Blades

Wind turbine design standards recommend the use of statistical modeling coupled with extrapolation of the short-term load data to long-term periods for fatigue reliability assessment. However, statistical error and computational expense can limit the accuracy of such approaches. In the case of wind turbine blades, the errors are more significant because of the high material fatigue exponent that makes the damage estimations more sensitive to variations. In addition, due to different excitation sources, the flapwise load range histogram is not unimodal, and thus its statistical modeling is complex. In the present work, we provide three methods for statistical modeling of the flapwise bending moment ranges including a novel approach based on frequency-based separation of the modes. The first two methods are simplified approaches for modeling the most crucial load ranges using unimodal distributions and the third method involves multimodal distribution fitting. The research is based on 3600 10-minute aeroelastic simulations of DTU 10MW case study wind turbine from which a benchmark damage equivalent load (DEL) is calculated. The DEL calculated by each of the three proposed methods is compared to this reference. The results show that the conventional approach based on using 6 seeds as well as using mixture models fitted on the limited data lead to under-conservative results with errors up to 23%. On the other hand, the simplified unimodal approaches provided in this work can provide conservative estimations of the fatigue damage with mean values 5% and 12% higher than the benchmark. However, the variability of the DEL estimates is higher when using unimodal extrapolation of the load ranges, and the data can be conservative by 17.5%. The proposed unimodal fits suggested for modeling and extrapolation of the blade's load ranges provide less errors relatively and most importantly conservative DEL estimations while maintaining computational efficiency.

blade fatigue↗

Biomass Production with Conservation Practices for Two Iowa Watersheds

Hydrologic modeling was used to estimate potential changes in nutrients, suspended sediment, and streamflow in various biomass production scenarios with conservation practices under different landscape designs. Two major corn and soybean croplands were selected for study: the South Fork of the Iowa River watershed and the headwater of the Raccoon River watershed. A physically based model, the Soil and Water Assessment Tool, was used to simulate hydrology and water quality under different scenarios with conservation practices and biomass production. Scenarios are based on conservation practices and biomass production; riparian buffer (RB), saturated buffer, and grassed waterways; various stover harvest rates of 30%, 45%, and 70% with and without winter cover crops; and conversion of marginal land to switchgrass. Conservation practices and landscape design with different biomass feedstocks were shown to significantly improve water quality while supporting sustainable biomass production. Model results for nitrogen, phosphorus, and suspended sediments were analyzed temporally at spatial scales that varied from hydrologic response units to the entire watershed. With conservation practices, water quality could potentially improve by reducing nitrogen loads by up to 20%–30% (stover harvest with cover crop), phosphorus loads by 20%–40% (RB), and sediment loads by 30%–70% (stover harvest with cover crop and RB).

54 ENVIRONMENTAL SCIENCES↗

Best Practices for Plug Load Management Using a Building Energy Management System

The University of California San Diego (UCSD) successfully integrated PLCs with their BEMS, which resulted in 66% energy savings over one week across 25 plug loads (K. Chia et al. 2023). UCSD documented each step of this effort, highlighting best practices along the way, in their 10-page brief, "Best Practices for Plug Load Management Using a Building Energy Management System" (also referred to as "brief" in this document). This fact sheet provides highlights and key takeaways from UCSD's brief. The reader is encouraged to read UCSD's full brief if they wish to move forward with implementing PLC integration with their BEMS.

Building Energy Management System Integration↗