At least 55 records · Page 3

Powering DNA strand-displacement reactions with a continuous flow reactor

Living systems require a sustained supply of energy and nutrients to survive. These nutrients are ingested, transformed into low-energy waste products, and excreted. In contrast, synthetic DNA strand-displacement reactions typically run within closed systems provided with a finite initial supply of reactants. Once the reactants are consumed, all net reactions halt and the system ceases to function. In the study, we ran DNA strand-displacement reactions in a continuous flow reactor, infusing fresh reactants and withdrawing waste, enabling the system to dynamically update its outputs in response to changing inputs. Running DNA strand-displacement reactions inside of continuous flow reactors allows the system to be re-used for multiple rounds of computation, which could enable the execution of more elaborate information processing tasks, including single-rail negation and sequential logic circuits.

59 BASIC BIOLOGICAL SCIENCES↗

A clean air continuous flow propulsion facility

Consideration is given to a contaminant-free, high enthalpy, continuous flow facility designed to obtain detailed code validation measurements of high speed combustion. The facility encompasses uncontaminated air temperature control to within 5 K, fuel temperature control to 2 K, a ceramic flow straightener, drying of inlet air, and steady state continuous operation. The air heating method provides potential for independent control of contaminant level by injection, mixing, and heating upstream. Particular attention is given to extension of current capability of 1250 K total air temperature, which simulates Scramjet enthalpy at Mach 5.

Krauss, R. H.↗

Continuous Flow Photoelectrochemical Reactor with Gas Permeable Photocathode: Enhanced Photocurrent and Partial Current Density for CO 2 Reduction

Photoelectrochemical (PEC) CO 2 reduction using a photocathode is an attractive method for making valuable chemical products due to its simplicity and lower overpotential requirements. However, previous PEC processes have often been diffusion-limited leading to low production rates of the CO 2 reduction reaction, due to inefficient gas diffusion through the liquid electrolyte to the catalyst surface, particularly at high current densities. In this study, a gas-permeable photocathode in a continuous flow PEC reactor is incorporated, which facilitates the direct supply of CO 2 gas to the photocathode-electrolyte interface, unlike dark reaction-based flow reactors. This concept is demonstrated using Ag-TiO 2 on carbon paper, illuminated through a quartz window and flowing liquid electrolyte. CO 2 supply is managed via pressure and flow control on the non-illuminated side of the carbon paper. The photocurrent density is significantly influenced by the flow rates and pressure of CO 2 gas, and the electrolyte flow rates. Compared to the traditional H-cell, the continuous PEC flow reactor achieves ≈10-fold increase in CO faradaic efficiency, 30-fold increase in production rate and 16-fold increase in stability without catalyst modifications. This work provides essential insights into the design and application of continuous gas-liquid flow PEC reactor systems, highlighting their potential for other PEC reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High efficiency continuous-flow production of radioisotopes

Methods and systems are provided for continuous-flow production of radioisotopes with high specific activity. Radioisotopes with high specific activity produced according to the methods described are also provided. The methods can include causing a liquid capture matrix to contact a target containing a target nuclide; irradiating the target with radiation, ionizing radiation, particles, or a combination thereof to produce the radionuclides that are ejected from the target and into the capture matrix; and causing the liquid capture matrix containing the radionuclides to flow from the target to recover the capture matrix containing the radionuclides with high specific activity. The methods are suitable for the production of a variety of radionuclides. For example, in some aspects the target nuclide is 237Np, and the radionuclide is 238Np that decays to produce 238Pu. In other aspects, the target nuclide is 98Mo, and the radionuclide is Mo that decays to produce 99mTc.

07 ISOTOPE AND RADIATION SOURCES↗

Continuous-flow electrophoretic separator for biologicals

In the near absence of gravity, a continuous-flow type of electrophoretic separator can be operated with a much thicker separation chamber than is possible under 1 g conditions. This should permit either better resolution or shorter separation time per unit of sample. An apparatus to perform experiments on sounding rockets is under development and will be described. The electrophoresis cell is 5 mm thick by 5 cm wide with 10 cm long electrodes. It is supplied with buffer, sample, and coolant at about 4 C through the use of a passive refrigerant system. UV sample detection and provision for recovery and cold storage of up to 50 sample fractions are now being added to the basic unit. A wide range of operating conditions are electronically programmable into the unit, even up to a short time before flight, and a further range of some parameters can be achieved by exchanging power supplies and by changing gears in the motor drive units of the pump. The preliminary results of some separation studies on various biological products using a commercially available electrophoretic separator are also presented.

Mccreight, L. R.↗

Hydrogenolysis of n -eicosane over Ru-based catalysts in a continuous flow reactor

The hydrogenolysis of n-eicosane (C 20 H 42 ) was studied under differential conditions over Ru-based catalysts including Ru/SiO 2 , Ru/TiO 2 , and Ru/SBA-15, using a continuous flow reactor that was specially designed for large hydrocarbon reactants that are solids at room temperature. Similar rates and product distributions were obtained for Ru/SiO 2 and Ru/SBA-15 at 433 K, with the most abundant products being C 1 and C 19 hydrocarbons and smaller amounts of C 8 to C 18 also being produced. The higher yield of C 1 and C 19 indicates that cleavage of the terminal C-C bond is somewhat more facile than an internal C-C bond. At 473 K the product distribution shifted to mostly C 1 suggesting that, at this temperature, the adsorbed alkyl fragments undergo complete C-C bond scission prior to desorbing. Here, the conversion was also found to be inversely proportional to the H 2 pressure. Similar results were obtained for Ru/TiO 2 except this catalyst was found to be less active than both Ru/SiO 2 and Ru/SBA-15.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous flow electrophoretic separation of proteins and cells from mammalian tissues

This paper describes an apparatus for continuous flow electrophoresis (CFE), designed to separate macromolecules and cells at conditions of microgravity. In this CFE, buffer flows upward in a 120-cm long flow chamber, which is 16-cm wide x 3.0-mm thick in the microgravity version (and 6-cm wide x 1.5-mm thick in the unit-gravity laboratory version). Ovalbumin and rat serum albumin were separated in space (flight STS-4) with the same resolution of the two proteins achieved at 25 percent total w/v concentration that was obtained in the laboratory at 0.2 percent w/v concentration. Rat anterior pituitary cells, cultured human embryonic kidney cells, and canine Langerhans cells were separated into subpopulations (flight STS-8) more effectively than in unit gravity, with comparable resolution having been achieved at 100 times the concentration possible on earth.

Hymer, W. C.↗

Bioprocessing in Microgravity: Applications of Continuous Flow Electrophoresis to Rat Anterior Pituitary Particles

In this report we describe the results of a continuous flow electrophoresis (CFE) experiment done on STS-65 in which we tested the idea that intracellular growth hormone (GH) particles contained in a cell lysate prepared from cultured rat anterior pituitary cells in microgravity might have different electrophoretic mobilities from those in a synchronous ground control cell lysate. Collectively, the results suggested that CFE processing in microgravity was better than on earth; more samples could be processed at a time (6 x) and more variant forms of GH molecules could be resolved as well. We had also hoped to carry out a pituitary cell CFE experiment, but failure of the hardware required that the actual cell electrophoresis trials be done on earth shortly after Shuttle landing. Data from these experiments showed that space-flown cells possessed a higher electrophoretic mobility than ground control cells, thereby offering evidence for the idea that exposure of cultured cells to microgravity can change their net surface charge-density especially when the cells are fed. Collectively, the results from this pituitary cell experiment document the advantage of using coupled cell culture and CFE techniques in the microgravity environment.

Hymer, W. C.↗

Modification of the continuous flow diffusion chamber for use in zero-gravity

The design philosophy and performance characteristics of the continuous flow diffusion chamber developed for use in ground-based simulation of some of the experiments planned for the atmospheric cloud physics laboratory during the first Spacelab flight are discussed. Topics covered include principle of operation, thermal control, temperature measurement, tem-powered heat exchangers, wettable metal surfaces, sample injection system, and control electronics.

Keyser, G.↗

Pre-flight report on cultured human embryonic kidney cell handling and cell electrophoresis. Prepared prior to continuous-flow electrophoretic separation experiments aboard space shuttle flight STS-8

Studies of the physical properties of continuous-flow zero-G electrophoretic separator (CFES) buffer, the electrokinetic properties of human erythrocytes in the CFES buffer, the electrokinetic properties of human embryonic kidney cells in the CFES buffer, and the viability and yield of human embryonc kidney cells subjected to flight handling procedures are discussed. In general, the procedure for cell handling and electrophoresis of HEK-8514 cells in 1st or 2nd passage on STS-8 is acceptable if executed properly. The CFES buffer has ionic strength that is barely compatible with cell viability and membrane stability, as seen in experiments with human erythrocytes and trypan-blue staining of human kidney cells. Cells suspended in 10% dialysed horse serum for 3 days in the cold appear to be more stable than freshly trypsinized cells. 10% horse serum appears to be superior to 5% horse serum for this purpose. The mean absolute raw mobility of HEK-8514 cells in CFES buffer at 6 degrees, conductivity 0.055 mmho/cm, is 1.1 to 1.4 um-cm/V-sec, with a range of nearly a whole mobility unit.

Todd, P. W.↗

Separation of rat pituitary secretory granules by continuous flow electrophoresis

The separation of growth hormone-containing cytoplasmic secretory granules from the rat pituitary gland by continuous flow electrophoresis is described. The results are consistent with the hypothesis that granule subpopulations can be separated due to differences in surface charge; these, in turn, may be related to the oligomeric state of the hormone.

Hayes, Daniel↗

Fluid mechanics of continuous flow electrophoresis

The reported investigation has the objective to provide a basis for understanding the hydrodynamic characteristics of the continuous flow electrophoresis chamber and their effects on the separation process. Particular emphasis is placed on the role buoyancy plays in establishing the basic flow and affecting its stability. The flow and temperature field is discussed, taking into account mathematical models for the structure of the temperature field, models for the structure of the axial velocity field, a two-dimensional constant thermal conductivity model, the axial velocity field, a two-dimensional constant transport properties model, and one-dimensional velocity fields. Questions of hydrodynamic stability are considered, giving attention to the stability of a fully developed flow with an axial temperature gradient.

Saville, D. A.↗

Hydrothermal catalysis of waste greases into green gasoline, jet, and diesel biofuels in continuous flow supercritical water

Production of green gasoline, jet, and diesel biofuels from waste greases was achieved using a novel hydrothermal, continuous-flow catalytic process operating under supercritical water conditions, with recycled water the only added chemical. Thermally and chemically stable catalysts were explored to optimize yields of liquid biofuels and to minimize production of gases and acidic compounds. A 50:50 mixture of brown and yellow waste greases converted into 76.6 wt% liquid biocrude (BC); the remainder converted to water and gases. Less than 0.2% of the FS formed carbon char (mainly amongst catalyst particles). Various tubular reactors (Inconel, ® Hastelloy®, titanium, stainless) showed no interior defects, erosion, or mass loss after runs. Here, the titanium catalyst was fully recovered and regenerated back to its original potency. The BC was further refined into 28%, 48%, 20%, and 4 wt%, respectively for green gasoline, jet, diesel, and bunker. Biofuels were analyzed for compound class compositions and reaction mechanisms were proposed. The hundreds of identified fuel products (C3-C35) from processing oleic acid as a pure model compound were identified. The neat green gasoline and diesel biofuels along with a 50% green jet blend (with petroleum Jet A) were tested in appropriate spark ignition, turbine, and diesel engines at University of MN Engine Labs. Biofuels achieved 107.7%, 97.2%, and 101.3% engine power performance levels relative to petroleum fuels (91-Octane, Jet A, #2 Diesel) along with lower CO and pollutant emissions. Biofuels passed ASTM fuel specifications (D4814, D7566, D975) including mandated corrosion and low sulfur limits of all three biofuels.

09 BIOMASS FUELS↗

High-resolution, continuous-flow electrophoresis in microgravity

Approximate expressions which will allow estimation of performance enhancement in reduced gravity and will direct optimization of the various design parameters for a continuous flow electrophoresis system was devised. Other topics discussed include: (1) temperature and velocity distribution; (2) input power limitations in reduced gravity; and (3) effect of band distortion on resolution. A comparision of resolution for terrestrial and reduced gravity operations was also discussed.

Rhodes, P. H.↗

Decoding α-MoC 1− x Nanoparticle Formation in Continuous Flow via Machine Learning

Molybdenum carbide nanoparticles (α-MoC 1−x NPs) are promising catalysts that offer noble-metal-like performance at lower cost. We report a mild continuous-flow synthesis of α-MoC 1−x NPs from Mo(CO) 6 , coupled with in-line spectroscopic monitoring and machine learning (ML)-based analysis to quantify precursor conversion and product formation in real time. A multilayer perceptron ML model was found to accurately deconvolute complex, nonlinear spectral patterns, enabling identification of a two-step reaction pathway, involving precursor conversion to an amorphous intermediate followed by intraparticle crystallization to α-MoC 1−x NPs, with the first step being rate limiting. Ex situ small angle X-ray scattering (SAXS) and X-ray diffraction (XRD) validation confirm the predicted concentration profiles and crystallization behavior. This integrated approach showcases how ML can empower insights into NP nucleation and growth, paving the way for self-driving, flow-based platforms for NP synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and testing of a unique randomized gravity, continuous flow bioreactor

A rotating, null gravity simulator, or Couette bioreactor was successfully used for the culture of mammalian cells in a simulated microgravity environment. Two limited studies using Lipomyces starkeyi and Streptomyces clavuligerus were also conducted under conditions of simulated weightlessness. Although these studies with microorganisms showed promising preliminary results, oxygen limitations presented significant limitations in studying the biochemical and cultural characteristics of these cell types. Microbial cell systems such as bacteria and yeast promise significant potential as investigative models to study the effects of microgravity on membrane transport, as well as substrate induction of inactive enzyme systems. Additionally, the smaller size of the microorganisms should further reduce the gravity induced oscillatory particle motion and thereby improve the microgravity simulation on earth. Focus is on the unique conceptual design, and subsequent development of a rotating bioreactor that is compatible with the culture and investigation of microgravity effects on microbial systems. The new reactor design will allow testing of highly aerobic cell types under simulated microgravity conditions. The described reactor affords a mechanism for investigating the long term effects of reduced gravity on cellular respiration, membrane transfer, ion exchange, and substrate conversions. It offers the capability of dynamically altering nutrients, oxygenation, pH, carbon dioxide, and substrate concentration without disturbing the microgravity simulation, or Couette flow, of the reactor. All progeny of the original cell inoculum may be acclimated to the simulated microgravity in the absence of a substrate or nutrient. The reactor has the promise of allowing scientists to probe the long term effects of weightlessness on cell interactions in plants, bacteria, yeast, and fungi. The reactor is designed to have a flow field growth chamber with uniform shear stress, yet transfer high concentrations of oxygen into the culture medium. The system described allows for continuous, on line sampling for production of product without disturbing fluid and particle dynamics in the reaction chamber. It provides for the introduction of substrate, or control substances after cell adaptation to simulated microgravity has been accomplished. The reactor system provides for the nondisruptive, continuous flow replacement of nutrient and removal of product. On line monitoring and control of growth conditions such as pH and nutrient status are provided. A rotating distribution valve allows cessation of growth chamber rotation, thereby preserving the simulated microgravity conditions over longer periods of time.

Lassiter, Carroll B.↗