Search NASA⌕ Search

SEARCH · Search NASA

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Real-Time Interactive 4D-STEM Phase-Contrast Imaging From Electron Event Representation Data: Less computation with the right representation

The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.

4D-STEM↗

Photoreversible Color-Switching Cu-Doped TiO2 Nanoparticles for High-Contrast Rewritable Printing

Light-printable rewritable paper that can be used multiple times has attracted extensive attention because of its potential benefits in reducing environmental pollution and energy consumption. Developing rewritable paper with high black-to-colorless contrast, lasting legibility, and a fast response is fascinating but challenging. Here, we integrate the redox chemistry of Cu2+ ions into photoreductive TiO2 nanoparticles to produce Cu-doped TiO2 nanoparticles capable of highly photoreversible switching between colorless and black with excellent contrast and color stability. Incorporating such nanoparticles into hydroxyethyl cellulose produces a rewritable paper with the same appearance as that of conventional paper. More importantly, it demonstrates great features promising for practical applications, including high black-to-colorless contrast, fast light-printing (<20 s), long legible time (>3 days), high reversibility (>50 cycles), high resolution (90 μm), and large scale (A4 size) applicability.

Wang, Wenshou↗

Vegetation Response to Rising CO 2 Amplifies Contrasts in Water Resources Between Global Wet and Dry Land Areas

Rising atmospheric CO 2 impacts on vegetation physiological processes can alter land feedbacks on precipitation and water resources, but understanding of regional differences in these changes is uncertain. We investigate the impact of rising CO 2 on land water resources for different wetness levels using four Earth system models. We find an overall tendency of runoff to increase across all wetness levels. However, runoff increases in wet regions are much larger than those in dry regions, especially in wet seasons. This substantial amplification of contrasts between wet and dry regions increases at 3% per 100 ppm increase in CO 2 relative to the historical period, reaching 18% for a quadrupling of CO 2 , quantified by a new wetting contrast index (WCI). Physiological effects suppress evapotranspiration more in wet than dry regions, which has a larger contribution than radiative forcing to the amplification of runoff contrast, reshaping the spatial distribution of future land water resources.

58 GEOSCIENCES↗

Single-shot x-ray phase-contrast and dark-field imaging based on coded binary phase mask

We introduce a coded-mask-based multi-contrast imaging method for high-resolution phase-contrast and dark-field imaging. The method uses a binary phase mask designed to provide an ultra-high-contrast pattern and reference-free single-shot measurement and an algorithm based on maximum-likelihood optimization and automatic differentiation to perform simultaneous reconstruction of absorption, phase, and dark-field object images. Further, we demonstrate that the method has great potential for real-time quantitative phase imaging and wavefront sensing when combined with deep learning.

Qiao, Zhi (ORCID:0000000286285320)↗

Graphic contrastive learning analyses of discontinuous molecular dynamics simulations: Study of protein folding upon adsorption

A comprehensive understanding of the interfacial behaviors of biomolecules holds great significance in the development of biomaterials and biosensing technologies. In this work, we used discontinuous molecular dynamics (DMD) simulations and graphic contrastive learning analysis to study the adsorption of ubiquitin protein on a graphene surface. Our high-throughput DMD simulations can explore the whole protein adsorption process including the protein structural evolution with sufficient accuracy. Contrastive learning was employed to train a protein contact map feature extractor aiming at generating contact map feature vectors. Subsequently, these features were grouped using the k-means clustering algorithm to identify the protein structural transition stages throughout the adsorption process. The machine learning analysis can illustrate the dynamics of protein structural changes, including the pathway and the rate-limiting step. Our study indicated that the protein–graphene surface hydrophobic interactions and the π–π stacking were crucial to the seven-stage adsorption process. Upon adsorption, the secondary structure and tertiary structure of ubiquitin disintegrated. The unfolding stages obtained by contrastive learning-based algorithm were not only consistent with the detailed analyses of protein structures but also provided more hidden information about the transition states and pathway of protein adsorption process and structural dynamics. Our combination of efficient DMD simulations and machine learning analysis could be a valuable approach to studying the interfacial behaviors of biomolecules.

97 MATHEMATICS AND COMPUTING↗

Coarsening dynamics of ternary polymer solutions with mobility and viscosity contrasts

Using phase-field simulations, we investigate the bulk coarsening dynamics of ternary polymer solutions undergoing a glass transition for two models of phase separation: diffusion only and with hydrodynamics. The glass transition is incorporated in both models by imposing mobility and viscosity contrasts between the polymer-rich and polymer-poor phases of the evolving microstructure. For microstructures composed of polymer-poor clusters in a polymer-rich matrix, the mobility and viscosity contrasts significantly hinder coarsening, effectively leading to structural arrest. For microstructures composed of polymer-rich clusters in a polymer-poor matrix, the mobility and viscosity contrasts do not impede domain growth; rather, they change the transient concentration of the polymer-rich phase, altering the shape of the discrete domains. This effect introduces several complexities to the coarsening process, including percolation inversion of the polymer-rich and polymer-poor phases—a phenomenon normally attributed to viscoelastic phase separation.

Chemistry↗

Comparison of Shadowgraphy and X-Ray Phase Contrast Methods for Characterizing a DT Ice Layer in an Inertial Confinement Fusion Target

Shadowgraphy and x-ray phase contrast (XPC) imaging are two techniques that are used for characterizing the deuterium-tritium ice layer in Inertial Confinement Fusion targets. Each technique has limitations that affect how accurately they can characterize small crystalline defects and measure the ice-thickness non-uniformities that may be only a few micrometers in height. The concern is that shadowgraphy may be overly sensitive to the shape and depth of defects in the surface and insufficiently sensitive to the shape of longer-wavelength roughness, while x-ray phase contrast may be too insensitive to defects in the ice surface. Multiple ice layers with different thicknesses (40 to 63 μm), thickness uniformities (peak-valley variations that range from <2- to 12 μm), and crystal defects were analyzed using shadowgraphy and x-ray phase contrast techniques. The results from each method agree when the ice layer is uniformly thick and the crystal lacks defects. That agreement worsens as the number of defects in the surface of the ice layer increases and the roughness that is determined from a shadowgram image of the target’s limb is greater than can be justified by the number of defects that are seen in the target’s front and rear surfaces. The XPC technique is considerably less sensitive to surface defects, in part due to the poorer dynamic range and image resolution compared to shadowgraphy. Localized regions of the ice layer that are thicker or thinner than the average thickness of the layer are reported by shadowgraphy to be smaller in height and footprint (by up to 30%) than by XPC. As a result, the two techniques report different ice layer thicknesses that can vary by up to 10%. Shadowgraphy results from two caustics that trace different paths through the target, and, in theory, image the same ice-vapor surface (but reflect from either the vapor or ice side of the interface) did not consistently characterize the size or shape of ice features to be the same magnitude. Here, the XPC technique provides the best assessment of low-mode (l < 7) roughness in the ice layer. Shadowgraphy results using the strongest caustic is best for detecting the presence of grooves in the ice, though not for quantifying the size of them. If multiple grooves are present it is best to discard and reform the ice layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-sensitivity in vivo contrast for ultra-low field magnetic resonance imaging using superparamagnetic iron oxide nanoparticles

Magnetic resonance imaging (MRI) scanners operating at ultra-low magnetic fields (ULF; <10 mT) are uniquely positioned to reduce the cost and expand the clinical accessibility of MRI. A fundamental challenge for ULF MRI is obtaining high-contrast images without compromising acquisition sensitivity to the point that scan times become clinically unacceptable. Here, we demonstrate that the high magnetization of superparamagnetic iron oxide nanoparticles (SPIONs) at ULF makes possible relaxivity- and susceptibility-based effects unachievable with conventional contrast agents (CAs). We leverage these effects to acquire high-contrast images of SPIONs in a rat model with ULF MRI using short scan times. This work overcomes a key limitation of ULF MRI by enabling in vivo imaging of biocompatible CAs. These results open a new clinical translation pathway for ULF MRI and have broader implications for disease detection with low-field portable MRI scanners.

42 ENGINEERING↗

Temporal prepulse contrast degradation in high-intensity CPA lasers from anisotropy of amplifier gain media

Here, we present a study of the temporal pre-pulse contrast degradation of high focused intensity pulses produced in CPA laser systems due to imperfections in amplifier design, alignment of amplifier components, and crystal inhomogeneity. Using an extended cross-polarized imaging technique, we demonstrate the presence of multiple crystal domains inside Ti:sapphire slabs with ≈10 cm diameter. Furthermore, the results of our numerical calculations show that crystalline c-axis orientation inhomogeneity caused by these crystal domains can lead to generation of pre-pulses with relative contrast >10 -10 within several picoseconds before the main pulse. In a multiple-slab amplifier head configuration sometimes used in high repetition rate systems, the misalignment of the amplifier slabs crystalline c-axes with respect to each other can lead to the generation of pre-pulses with relative contrast as high as 10 -6 , depending on the magnitude of misalignment.

47 OTHER INSTRUMENTATION↗

Temporal contrast degradation from mid-spatial-frequency surface error on stretcher mirrors

Temporal contrast degradation due to mid-spatial-frequency error in chirped-pulse amplification stretcher optics is studied. Third-order cross-correlation measurements reveal a temporal peak that appears when using two different mirrors processed by magnetorheological finishing, despite an improvement in rms roughness compared to a third unprocessed mirror. Simulations based on measured power spectral density show how the actual impact on contrast is different from measurements using a typical bandwidth-limited third-order cross correlator. Furthermore, strategies are proposed to avoid this type of contrast degradation while exploiting computer numerically controlled polishing techniques for enhancement of surface figure and roughness.

47 OTHER INSTRUMENTATION↗

Simultaneous contrast improvement and temporal compression using divided-pulse nonlinear compression

We experimentally demonstrate how divided-pulse nonlinear compression can be used to improve the temporal contrast of a laser pulse train while simultaneously temporally compressing the pulses. We measure a contrast improvement of almost four orders of magnitude on a nanosecond time scale and temporally compress the pulses from 1.2 ps to 187 fs. The efficiency of our method is also competitive with other contrast improvement methods, with 72% efficiency measured for the main pulse. We expect the method will be useful in the continuing development of high-power, Yb regenerative amplifiers, which suffer from both significant prepulses and relatively long pulse durations.

47 OTHER INSTRUMENTATION↗

Amorphous silicon carbide high contrast gratings as highly efficient spectrally selective visible reflectors

We report spectrally selective visible wavelength reflectors using hydrogenated amorphous silicon carbide (a-SiC:H) as a high index contrast material. Beyond 610nm and through the near infrared spectrum, a-SiC:H exhibits very low loss and exhibits an wavelength averaged index of refraction of n = 3.1. Here we design, fabricate, and characterize such visible reflectors using a hexagonal array of a-SiC:H nanopillars as wavelength-selective mirrors with a stop-band of approximately 40 nm full-width at half maximum. The fabricated high contrast grating exhibits reflectivity R >94% at a resonance wavelength of 642nm with a single layer of a-SiC:H nanopillars. The resonance wavelength is tunable by adjusting the geometrical parameters of the a-SiC:H nanopillar array, and we observe a stop-band spectral center shift from 635 nm up to 642 nm. High contrast gratings formed from a-SiC:H nanopillars are a promising platform for various visible wavelength nanophotonics applications.

Bauser, Haley C.↗

AlSb as a material for high index contrast nanophotonics

High contrast materials, i.e., materials with a high refractive index and low optical loss, are of wide interest for nanophotonics and metasurface designs at optical and near infrared wavelengths. We explore aluminum antimonide (AlSb) as a high contrast nanophotonic material, using the design of high contrast gratings (HCGs) for low loss dielectric mirrors as an example. The high index of refraction and low absorption coefficient of AlSb in the visible wavelength range enable designs of HCGs that can be effectively optimized to form mirrors with 93.5% reflectivity at red visible wavelengths. We detail a co-sputtering synthesis method for AlSb films, and achieve our target high index of refraction of 3.5 for 635 nm light. We also find that the high sensitivity of AlSb oxidation requires specific handling procedures in developing deposition processes to yield a near zero absorption coefficient.

Bauser, Haley C.↗

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases↗

Contrast Matching Biopolymers: A SANS-Based Approach to Structural Characterization of Chitosan

Immobilizing enzymes in polysaccharide-based matrices has been shown to improve both their stability and their catalytic efficiency. Among available materials, chitosan was selected for its abundance, biocompatibility, and versatility in a range of applications. While the broader aim of this work is to study chitosan as a matrix for immobilizing carbonic anhydrase (CA) for CO₂ capture, this study focused on determining the contrast match point (CMP) of hydrogenated and deuterated chitosan in D₂O:H₂O mixtures to enable future structural investigations using small-angle neutron scattering (SANS). Previous work successfully synthesized deuterated chitosan from Rhizopus oryzae mycelia and assessed the degree of deuteration using Fourier-transform infrared spectroscopy (FTIR) and nuclear magnetic resonance (NMR). Building on this foundation, the current study determined the CMPs of both H-chitosan and D-chitosan by performing SANS measurements across a range of D₂O:H₂O solvent contrasts. The extracted CMPs for both forms correlated well with their respective calculated scattering length densities (SLDs), validating the experimental approach. These results establish a critical reference for selective contrast matching in future SANS studies of carbonic anhydrase immobilized in chitosan matrices, enabling detailed structural analysis of enzyme–matrix interactions.

Kosgallana, Chathurika J [ORNL] (ORCID:00000002851↗

Contrast and Temperature Dependence of Multi-epoch High-resolution Cross-correlation Exoplanet Spectroscopy

While high-resolution cross-correlation spectroscopy (HRCCS) techniques have proven effective at characterizing the atmospheres of transiting and nontransiting hot Jupiters, the limitations of these techniques are not well understood. We present a series of simulations of one HRCCS technique, which combines the cross-correlation functions from multiple epochs, to place temperature and contrast limits on the accessible exoplanet population for the first time. We find that planets approximately Saturn-sized and larger within ∼0.2 au of a Sun-like star are likely to be detectable with current instrumentation in the L band, a significant expansion compared with the previously studied population. Cooler (T {sub eq} ≤ 1000 K) exoplanets are more detectable than suggested by their photometric contrast alone as a result of chemical changes that increase spectroscopic contrast. The L-band CH{sub 4} spectrum of cooler exoplanets enables robust constraints on the atmospheric C/O ratio at T {sub eq} ∼ 900 K, which have proven difficult to obtain for hot Jupiters. These results suggest that the multi-epoch approach to HRCCS can detect and characterize exoplanet atmospheres throughout the inner regions of Sun-like systems with existing high-resolution spectrographs. We find that many epochs of modest signal-to-noise ratio (S/N{sub epoch} ∼ 1500) yield the clearest detections and constraints on C/O, emphasizing the need for high-precision near-infrared telluric correction with short integration times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Analysis of TRGBs (CATs) from Unsupervised, Multi-halo-field Measurements: Contrast is Key

The tip of the red giant branch (TRGB) is an apparent discontinuity of the luminosity function (LF) due to the end of the red giant evolutionary phase and is used to measure distances in the local universe. In practice, tip localization via edge detection response (EDR) relies on several methods applied on a case-by-case basis. It is hard to evaluate how individual choices affect a distance estimation using only a single host field while also avoiding confirmation bias. To devise a standardized approach, we compare unsupervised, algorithmic analyses of the TRGB in multiple halo fields per galaxy. We first optimize methods for the lowest field-to-field dispersion, including spatial filtering, smoothing, and weighting of LF, color band selection, and tip selection based on the number of likely RGB stars and the ratio of stars below versus above the tip (R). We find R, which we call the tip contrast, to be the most important indicator of the quality of EDR measurements; higher R selection can decrease field-to-field dispersion. Further, since R is found to correlate with the age or metallicity of the stellar population based on theoretical modeling, it might result in a displacement of the detected tip magnitude. We find a tip-contrast relation with a slope of -0.023 ± 0.0046 mag/ratio, an ~5σ result that can be used to correct these variations in the detections. When using TRGB to establish a distance ladder, consistent TRGB standardization using tip-contrast relation across rungs is vital to make robust cosmological measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

High Contrast Pattern Projection To Enable Background Oriented Schlieren Based Air Leak Detection Through Any Interior Or Exterior Building Surface

Air leakage in buildings wastes an estimated 4 quads of energy per year in the United States. Finding and sealing leakage sites is critical in existing buildings. Previous work has shown that background oriented Schlieren (BOS) imaging can be used to visualize air leakage but requires the leak to exit through a high contrast surface like a brick wall. To remedy this, different techniques of projecting various high contrast patterns on low contrast building surfaces like interior gypsum walls or vinyl siding were investigated. For each technique, the background quality was measured and compared to an ideal printed random dot background. The background quality metrics were correlated with the measured visualization metrics to understand which metrics are most important for maximizing air leak visualization performance. In this work, leakage visualization performance is presented for these various projected backgrounds with an aim to expand the building surfaces suitable for the BOS leak detector.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)↗