Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Ecodriving Control in Electrified Connected and Autonomous Vehicles Using Approximate Dynamic Programing

Connected and automated vehicles (CAVs), particularly those with a hybrid electric powertrain, have the potential to significantly improve vehicle energy savings in real-world driving conditions. In particular, the ecodriving problem seeks to design optimal speed and power usage profiles based on available information from connectivity and advanced mapping features to minimize the fuel consumption over an itinerary. This paper presents a hierarchical multilayer model predictive control (MPC) approach for improving the fuel economy of a 48 V mild-hybrid powertrain in a connected vehicle environment. Approximate dynamic programing (DP) is used to solve the receding horizon optimal control problem, whose terminal cost is approximated with the base policy obtained from the long-term optimization. The controller was tested virtually (with deterministic and Monte Carlo simulation) across multiple real-world routes, demonstrating energy savings of more than 20%. The controller was then deployed on a test vehicle equipped with a rapid prototyping embedded controller. In-vehicle testing confirm the energy savings obtained in simulation and demonstrate the real-time ability of the controller.

Automation & Control Systems↗

Multi-Core Microcontroller Hardware In the Loop System for Electric Machine Control

Hardware in the Loop (HIL) is a simulation technique used to reduce the software development cycle and test control systems in a non-destructive environment. This work describes a cost effective HIL simulator on a dual core microcontroller in which one core acts as a controller and the other emulates the system under control. The emulator runs one step per Pulse Width Modulation (PWM) period in real time. To handle the computational burden and prioritize execution of simulation and control tasks, an interrupt-based software architecture with task prioritization has been developed. As a demonstration, the HIL has been implemented on a Texas Instruments TMS320F28379D dual core microcontroller, which emulates a Permanent Magnet Synchronous Machine (PMSM) with resolver feedback. Hardware peripherals are developed and tested concurrently with the control system, providing higher confidence in the software. By using the peripherals in the HIL development, the controller exercises either the HIL emulation or a pin compatible PMSM testbench. To quantify performance and validate the processor based emulator, the HIL results are compared to the preexisting testbench for accuracy benchmarking at no-load and under load for a range of operating points.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated control of individual plasma scalars with simultaneous neoclassical tearing-mode suppression

A novel integrated-control architecture has been tested in nonlinear, one-dimensional simulations using the control-oriented transport simulator (COTSIM©) and in DIII-D experiments. Integrated architectures that can perform continuous-mission control while also handling off-normal events will be vital in future reactor-grade tokamaks. Continuous-mission controllers for individual magnetic and kinetic scalars (thermal stored-energy (W), volume-average toroidal rotation (Ω Φ ), and safety factor profile (q) at different spatial locations) have been integrated in this work with event-triggered neoclassical tearing-mode (NTM) suppression controllers by combining them into an architecture augmented by a supervisory and exception handling (S&EH) system and an actuator management (AM) system. Here, the AM system, which enables the integration of competing controllers, solves in real time a nonlinear optimization problem that takes into account the high-level control priorities dictated by the S&EH system. The resulting architecture offers a high level of integration and some of the functionalities that will be required to fulfill the advanced-control requirements anticipated for ITER. Initial simulations using COTSIM suggest that the plasma performance and its MHD stability may be improved under integrated feedback control. In addition, the integrated-control architecture has been implemented in the DIII-D plasma control system and tested experimentally for the first time ever in DIII-D in a high-q min scenario, which is a candidate for steady-state operation in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BOPTest As a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

BOPTEST as a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The EGS Collab Project: Status and Accomplishments

The EGS Collab project, supported by the US Department of Energy, is addressing challenges in implementing enhanced geothermal systems (EGS). This includes improving understanding of the stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The project is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory. Data and observations from the field test are compared to simulations to understand processes and to build confidence in numerical modeling of the processes. In Experiment 1, we examined hydraulic fracturing an underground test bed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km. We drilled eight sub-horizontal boreholes in a well-characterized phyllite. Six of the boreholes were instrumented with many sensor types to allow careful monitoring of stimulation events and flow tests, and the other two boreholes were used for water injection and production. We performed a number of stimulations and flow tests in the testbed. Our monitoring systems allowed detailed observations and collection of numerous data sets of processes occurring during stimulation and during dynamic flow tests. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Data were rapidly analyzed, allowing adaptive control of the tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results. Many simulations were performed in near-real-time in conjunction with the field experiments, with more detailed process study simulations performed on a longer timeframe. Experiment 2 will examine hydraulic shearing in a test bed being built at the SURF at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1. Five sets of fracture orientations were considered in design, and three orientations seem to be consistently observed.

EGS Collab↗

Inverter Controls for Smooth Transition Operation and Voltage Balancing of Networked Microgrids

With increasing penetrations of distributed energy resources (DERs), researchers have extensively studied the formation and networking of microgrids to improve reliability during distribution system outages. However, these operations might require DERs in the microgrids to switch between grid-following (GFL) and grid-forming (GFM) modes of operation. A smooth transition between the operation modes should be ensured to have a stable system operation and to avoid nuisance tripping. Additionally, as we network microgrids, inverter control schemes with voltage-balancing controls are needed for unbalanced distribution networks. This paper presents the design of a GFM and GFL capable inverter control scheme for reliable operation in networked microgrids with mechanisms for 1) smooth transition between the GFL and GFM modes, and 2) negative sequence voltage control for voltage balancing. Using electromagnetic transient (EMT) simulations, the control scheme is first tested on a simple two-source power system using a digital real-time simulator. Next, a real-world distribution feeder with unbalanced loading and multiple DERs is used to demonstrate stable operation during the networking of microgrids with voltage balance support.

distributed energy resources↗

Practical factors of envelope model setup and their effects on the performance of model predictive control for building heating, ventilating, and air conditioning systems

Model predictive control (MPC) for buildings is attracting significant attention in research and industry due to its potential to address a number of challenges facing the building industry, including energy cost reduction, grid integration, and occupant connectivity. However, the strategy has not yet been implemented at any scale, largely due to the significant effort required to configure and calibrate the model used in the MPC controller. While many studies have focused on methods to expedite model configuration and improve model accuracy, few have studied the impact a wide range of factors have on the accuracy of the resulting model. In addition, few have continued on to analyze these factors’ impact on MPC controller performance in terms of final operating costs. Therefore, this study first identifies the practical factors affecting model setup, specifically focusing on the thermal envelope. The seven that are identified are building design, model structure, model order, data set, data quality, identification algorithm and initial guesses, and software tool-chain. Then, through a large number of trials, it analyzes each factor's influence on model accuracy, focusing on grey-box models for a single zone building envelope. Finally, this study implements a subset of the models identified with these factor variations in heating, ventilating, and air conditioning MPC controllers, and tests them in simulation of a representative case that aims to optimally cool a single-zone building with time-varying electricity prices. It is found that a difference of up to 20%25 in cooling cost for the cases studied can occur between the best performing model and the worst performing model. The primary factors attributing to this were model structure and initial parameter guesses during parameter estimation of the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simultaneous control of the electron temperature and safety factor profiles in DIII-D using model-based optimal control techniques

Future tokamak power plants will likely operate using a single, well-defined plasma scenario, either in steady state or for very long pulse lengths. In order to enhance the robustness of the scenario, feedback controllers for a variety of plasma properties will be necessary to counteract any disturbances and ensure safe operation. However, only a limited set of actuators will be available to control many different quantities. Because of this, it is necessary to develop controllers that are able to regulate multiple plasma properties using a limited set of actuators. To this end, a controller has been developed for the simultaneous regulation of both the electron temperature and safety factor profiles in DIII-D. This algorithm uses a linear quadratic integral control synthesis approach based on a linearized model of the dynamics of the two profiles. Two neural network surrogate models, NubeamNet and MMMnet, are included to improve the fidelity of the model. Furthermore, the controller has been tested in simulation using COTSIM, and has demonstrated the ability to simultaneously track changes in both the electron temperature and safety factor targets, including changes in both the magnitude and the shape of the profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Controls For Reactor Technologies (acorn)

ACORN (Autonomous Controls fOr Reactor techNologies) software utilizes data, obtained from an experimental test bed and/or simulation, to implement a control command for microreactor operation. Command examples include a change to the temperature profile, power profiles, heat fluxes, etc. The control command recommended by the code is derived based on future predicted states of a microreactor, allowing proactive optimal and autonomous microreactor operation. The software is written in Python languages. The current software supports autonomous temperature controls of heat pipe simulator and autonomous heat flux controls of a 37 heat pipe non-nuclear testbed simulator (or its surrogate models).

Lin, Linyu [Idaho National Laboratory (INL), Idaho↗

Dynamics and Control of Microgrids as a Resiliency Source

Microgrids can be operated in a utility-connected mode with the neighboring distribution system or in an islanded mode in separation with the distribution system. As the major disasters occur more and more often, islanded microgrid is proposed as a possible solution to serve essential loads until the utility service is restored. This paper evaluates the feasibility of using microgrids as a resiliency resource by a field test. A control scheme, integrating droop control and feedback control, is applied on a modified IEEE 13-node test feeders. The simulation results validate the proposed control scheme and the transient stability

Lee, Lung-An↗

Simulant Testing of a Co-Decontamination (CoDCon) Flowsheet for a Product with a Controlled Uranium-to-Plutonium Ratio

Multiple tests of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet are being performed to determine the uncertainties associated with maintaining a target U/Pu ratio in the Pu-containing product. The first two flowsheet tests used simple dissolved fuel simulants containing only U and Pu, but increasingly more complex simulants will but used in subsequent tests, with the ultimate goal of performing tests with irradiated fuel. The flowsheet is designed so as not to create a purified Pu stream, but rather a mixture of U and Pu with a U/Pu mass ratio of 7/3. Uranium and Pu are first co-extracted into the TBP solvent, and then U(IV) is used to strip the Pu from the loaded solvent. A fresh TBP solvent stream is introduced at the same stage the Pu-containing aqueous stream exits. The flowrate of the fresh TBP solvent stream is adjusted so that sufficient U bleeds over into the Pu product to produce the desired U/Pu ratio. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio through adjustment of the fresh TBP solvent flowrate. This paper will describe the results of the first two CoDCon flowsheet tests.

CoDCon, fuel recycle, fuel reprocessing, on-line m↗

Development of control quality factor for HVAC control loop performance assessment I—Methodology (ASHRAE RP-1587)

This article is the second paper from the ASHRAE research project RP-1587, focusing on the methodology of obtaining a control quality factor (CQF). This article presents a development of two CQFs for assessing the heating, ventilation, and air-conditioning (HVAC) control loop performance. Both CQFs are able to detect whether the control loop is able to maintain the setpoint and identify the loop's ability to handle disturbances. In addition, the reversal behaviors are assessed as well. The first CQF (CQF-Harris) is proposed based on the normalized Harris index using the recursive least squares method. This recursive least squares method is selected because of its computational efficiency compared with the maximum likelihood estimation method. The second CQF (CQF-EWMA) is based on the exponentially weighted moving average of the error ratio. The assessment scale of excellent, good, fair, bad, and failed, which indicates the quality of the HVAC control loops, is established as well. The sensitivity analysis for both CQFs is also conducted, and it provides insights on choosing the appropriate parameters to compute such CQFs. Such parameters include the sampling frequency, the length of the moving window, and the variance of the unmeasured disturbance. The field evaluations and tests of the proposed CQFs for simulated control loops and real control loops can be found in the companion paper with the title 'Development of Control Quality Factor for HVAC Control Loop Performance Assessment - III: Field Testing and Results (ASHRAE RP-1587).'

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiple Environmental Influences on the Lightning of Cold-Based Continental Convection. Part II: Sensitivity Tests for Its Charge Structure and Land–Ocean Contrast

In Part I, an electrification scheme was described and a simulation of an observed cold-based storm from the U.S. Great Plains was validated with electrical observations. Most charge in the storm was separated by rebounding collisions of secondary ice originating from prior graupel–snow collisions. In this Part II, sensitivity tests are performed with the control simulation (Part I) and influences from environmental factors (aerosols, temperature, moisture, and shear) on lightning are elucidated. Environmental factors [e.g., convective available potential energy (CAPE)] controlling updraft speed are salient. When ascent is reduced by 30% and 70%, flashes become 70% fewer and disappear, respectively; faster ascent promotes positive cloud-to-ground (+CGs) flashes. Since cloud base is too cold (1°C) for coalescence, cloud condensation nucleus aerosol concentrations do not influence the lightning appreciably. The electrical response to varying concentrations of active ice nuclei is limited by most ice particles being secondary and less sensitive—a natural “buffer.” Imposing a maritime sounding suggests that the land–sea contrast in lightning for such storms is due to the vertical structure of environmental temperature and humidity. Weak CAPE, and both entrainment and condensate weight from a low cloud base, suppress ascent and charging. Maritime thermodynamic conditions reduce simulated flash rates by two orders of magnitude. Reducing aerosol loadings from continental to maritime only slightly reinforces this suppression. Last, a conceptual model is provided for how any simulated storm is either normal because graupel/hail is mostly positively charged or else is inverted/anomalous because graupel/hail is mostly negatively charged, with environmental factors controlling the charging. Impacts from microphysical processes, including three processes of secondary ice production, on lightning are analyzed.

54 ENVIRONMENTAL SCIENCES↗